• Title/Summary/Keyword: Fire Proof

Search Result 104, Processing Time 0.02 seconds

A Study on Cable Functional Failure Temperature by Exposed Fire in Nuclear Power Plants (원전 노출 화재시 케이블 기능상실 온도에 관한 연구)

  • Kim, Doo-Hyun;Lim, Hyuk-Soon
    • Journal of the Korean Society of Safety
    • /
    • v.26 no.5
    • /
    • pp.41-45
    • /
    • 2011
  • The fire event occurred in fire proof zone often causes serious electrical problems such as shorts, ground faults, or open circuits in nuclear power plants. These would be directed to the loss of safe shutdown capabilities performed by safety related systems and equipments The fire event can treat the basic design principle that safety systems should keep their functions with redundancy and independency. In case of a cable fire, operators can not perform their mission properly and can misjudge the situation because of spurious operation, wrong indication or instrument. These would deteriorate the plant capabilities of safety shutdown and make disastrous conditions. In this paper, the cables of the representative nuclear power plant in korea is selected and the cable functional failure temperature by exposed fire using Cable Response to Live Fire(CAROLFIRE) is studied. It is expected that the results are very useful to know the cable failure temperature by exposed fire. We confirmed the safety and integrity of the cable by exposed fire and those results will use the based data of cable exposed fire characteristics.

A Study on Fire Profection and Egress Countermeasure of the High Buildings in the Large City (대도시 고층건물의 방재 및 피난대책에 관한 연구)

  • 김동준
    • Journal of the Korean Society of Safety
    • /
    • v.5 no.1
    • /
    • pp.77-81
    • /
    • 1990
  • In the event of fire, the tendency of over­buildings and high­building resulted from the concentration in population in cities causes great losses of human lives and property. Man is able to prevent fire itself from taking place on his own efforts. One of fire preventions at high­buildings is to Survey the environmental situations around the constructions from the beginning, and when the construction is going on, it is indispensable to install appropriate water­proof dampers with all sorts of equipments. Hence, lots of the owner's investment of the buildings in fire prevention facilities is necessary and, so is constructions in agreement with every regulations.

  • PDF

A REPORT ON TEST RESULTS OF MANUALLY ACTUATED SIGNALING BOXES AND AUDIBLE SIGNAL APPLIANCES (발신기.음향장치 성능시험 보고)

  • Jang, Yang-Heon
    • Fire Protection Technology
    • /
    • s.13
    • /
    • pp.12-17
    • /
    • 1992
  • This report is announced about test results of manually actuated signaling boxes(manual call points) and audible signal appliances (alarm bell), so as to occupants, inhabitants or persons di-rectly concerned with the implementation and direction of emergency action initialation is the area protected. The testing plan was progressed devided by three testing items, external appearance inspec-tion, performance test and environment proof test. The purpose of this report is to analyze the characteristics of products.

  • PDF

Experimental Study on Making Databases for Fire Resistant Steel at High Temperature (내화강재의 고온특성 데이터베이스 구축 연구)

  • Kwon, In-Kyu
    • Fire Science and Engineering
    • /
    • v.27 no.5
    • /
    • pp.1-7
    • /
    • 2013
  • Fire at building can occur enormous damages to life, properties, and environment and the risk of fire breakout is going up higher because of application of combustible materials than before. Therefore, the steel industries are trying to develop fire resistant steel in order to sustain the load bearing capacity of steel structures during fire situation. In this paper, to give the basis data-bases for evaluation of structural stability of steel structures applied fire resistant steel, FR 490, the tests of mechanical and thermal properties at high temperature were conducted and the comparisons are done with the SM 490 that has the same mechanical one.

A RESEARCH ON EFFECTIVE FIRE/DISASTER PROTECTION OF UTILITY TUNNEL IN KOREA

  • Park, Hung-joo;Son, Bong-sei;Jee, Nam-yong
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1997.11a
    • /
    • pp.404-412
    • /
    • 1997
  • The pipes and cables buried below ground, which may have helped to improve city landscape, is becoming direct and indirect causes for various kinds of disaster in Korea. Every advantage from the use of utility tunnel can not be converted in a dollar since there is associated huge contribution to safe urban environment. The Korean government has a certain role to play in helping promote utility tunnels for the past years. Most recently, many utility tunnels have been being checked to find out safety level, especially fire safety level, and main problems and shortcomings are checked out as a result of this survey. Because the fire safety level of existing tunnel is low, possible approaches and solutions are presented according to the analysis of fire safety level. In order for these approaches to be effective, existing tunnel should be supplemented appropriately and extra equipment must be installed according to the solutions. Hopefully, by performing both improvement of existing utility tunnel that provide a fire/disaster proof and introducing new types of tunnel which influence utility management and maintenance, the recent disaster rate in Korea can be diminished up to a desirable rate in a near future.

  • PDF

A Study on the Smoke Proof Measure of High Rise Buildings. (건축화재시 피난대책에 관한 연구 -고층건물의 제연을 중심으로-)

  • 이영재;이근영
    • Fire Science and Engineering
    • /
    • v.4 no.1
    • /
    • pp.3-12
    • /
    • 1990
  • This study is to Present the air Pressurization system of staircase as a way to decrease the injury of human life which is suffocated by smoke when the fire break out in building. 1) The best among an air pressurization system of stairshaft Is multiple air Injection system established to be situated an air injection point in each layer. 2) If the air pressurization system is also applied to the elevator accessory room to use commonly, it can prevent from the smoke spreading and pollution inside building caused by stack effect of elevator shaft. 3) For the reasonable and safe escape and air pressurization system must be carried out from the project of basic shape of building under the close cooperation with architect and fire protection expert.

  • PDF

Fundamental Study of Fire-Proof Characteristics of High Strength Concrete Using Meta-Kaolin and Waste Tire Chip (메타카올린과 폐타이어 잔입자를 사용한 고강도콘크리트의 내화성능에 관한 기초적 연구)

  • Lee, Mun-Hwan;Lee, Sea-Hyun
    • Journal of the Korea Concrete Institute
    • /
    • v.20 no.1
    • /
    • pp.89-97
    • /
    • 2008
  • By replacing the meta-kaolin with cement and the waste tire chip with fine aggregate separately, the high strength concrete is protected from the spalling in fire and the method to constrain the temperature increase of steel bar within the concrete and the basic properties of the high strength concrete mixed with the material are reviewed. As the result, meta-kaolin increases the self fire proof characteristics of the concrete, the waste tire chip can share the internal expanding pressure so it can be deleted. In detail, using the meta-kaolin about the cement in 4$\sim$8% of weight ratio about the cement and the waste tire chip under the grade scope of 0.6$\sim$3 mm in 5$\sim$10% of weight ratio about the sand is very effective to prevent the spalling.

The Liquid Flame Proofing Agent's Permeating Effect of Wood Using Microwave (마이크로파를 이용한 목재의 액상방염약제 침투효과 연구)

  • Park, Cheul-Woo;Her, Jae-Won;Lim, Nam-Gi
    • Journal of the Korea Institute of Building Construction
    • /
    • v.11 no.3
    • /
    • pp.256-264
    • /
    • 2011
  • By implementing an analysis on the liquid flame proof agent infiltration of microwave-heated wood under soaking conditions (room temperature soaking, heat soaking), its correlation with wood temperature, and the structure of wood and permeating components after soaking in flame proof agent, which was carried out as basic research in order to improve the fire resistance performance of the wood itself, it is found that the infiltration increases as the microwave heating time increases, while for heat soaking, it is found that high infiltration as well as the stable permeability of flame proof agent is achievable. Also, when the wood temperature is more than $80^{\circ}C$, the infiltration by the flame proof agent increased, and a very even infiltration of flame proof agent was observed, which implies that the liquid flame proof agent has a dependency on temperature change of the wood as a condition to penetrate into the wood. As a result of fine structure analysis, the flame proof agent transfer between cells through pits was considered as a cause to increase the infiltration of flame proof agent, and it is also shown that for heat soaking among the permeating component analysis, as the crystallized flame proof agent around the heartwood and sapwood inner pits increases, the flame proof agent can penetrate into the the heartwood part.

A Study on the Performance Evaluation of Fitting for Light-gauge Stainless Steel Pipe (경량 스테인리스 강관용 이음쇠의 성능평가에 관한 연구)

  • Nam, Jun-Seok;Park, Joo-Hwan;Min, Kyung-Tak;Kim, Yeob-Rae;Song, Chul-Gang
    • Fire Science and Engineering
    • /
    • v.24 no.6
    • /
    • pp.89-97
    • /
    • 2010
  • In recent fire protection system, the pipings should be light weighted, seismic proof and wrought with non-welding method. The light weighted stainless steel pipes and fittings, satisfying these requirements, are already used as a fire protection system in Germany, Netherland, Taiwan, Australia, United States and Japan. Accordingly, performance evaluation tests were carried out to determine whether or not the fittings can be used in the pipings. As the performance evaluation tests, we conducted vibration test, water hammering test, bending test and fire test. With the results of the tests, we concluded that the fittings can be used in the fire protection system, and that the life expectancy of the fittings exceeds that of buildings.

Analysis on Field Professionals' Assessment of Alternative Fire Escape Methods in Apartment Building (공동주택 대안적 화재 피난방식에 대한 건설전문가 평가조사)

  • Lee, Myung Sik;Lee, So Young
    • KIEAE Journal
    • /
    • v.9 no.5
    • /
    • pp.21-28
    • /
    • 2009
  • In apartment buildings, casualties, especially fatalities have occurred in balcony areas in fires if residents fail to escape to the main entrance. Potential consequences of a particular infrequent event should be considered. In attempting to design apartment buildings for fire safety, alternative escape methods such as vertical penetration could be considered. The purpose of this study is to investigate present building regulations regarding apartment buildings and examine pros and cons of the current escape method and alternative escape methods. Focus group interview was conducted to discuss problems of fire escape methods. In addition, questionnaires were distributed to field professionals working in architecture, construction and related industries. Among 500 questionnaires distributed, 192 questionnaires were collected. Usable 162 questionnaires were analyzed using SPSS 15. Regarding alternative fire escape methods, several concerns were mentioned. Safety, privacy, security, effectiveness of escape, water proof problems were raised. Based on the opinions, vertical penetration between apartment unit appeared more safe, secure, effective than horizontal penetration. However, both methods have its own pros and cons under specific contexts. Alternative escape methods need be considered for a selective options for residents in case of fire.