• 제목/요약/키워드: Fire Proof

검색결과 104건 처리시간 0.019초

3시간 내화도료의 개발을 위한 내화성능 및 부착특성 평가에 관한 실험적 연구 (The experimental study on the Evaluation of fire-proof performance and bond characteristics for development of 3hours Fire-Proof paint)

  • 김수영;김성길;이한승
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2012년도 추계 학술논문 발표대회
    • /
    • pp.63-64
    • /
    • 2012
  • Recently, Fire-proof performance of buildings becomes important to ensure safety. As a result, fire-proof paint is required for 3 hours. However, Experiments are only performed by standard KS F 2271 for estimation of fire-proof paint. Because there is no domestic estimation standard for performance of fire-proof paint as well. So estimation standard of fire-proof paint is needed to guarantee their performance for establishing quality system and to assure same performance for safety of people in the building from unpredicted fire accident. Owing to these reasons, we studied comparative estimation for quality performance of two kinds of fire-proof paint and bond performance.

  • PDF

MICROWAVE 가열 건조에 의한 내화 점토의 열에너지 분포 특성 연구 (A Study on the Characteristics of Heat Energy Distribution of Fire-Proof Clay with Microwave Heating Drying)

  • 이승준;김윤제
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집B
    • /
    • pp.752-757
    • /
    • 2001
  • The characteristics of heat energy distribution on the fire-proof clay with microwave heating drying are numerically investigated using finite element method. The modelled regular hexahedron chamber$(50cm\times50cm\times50cm)$ filled with air consists of vertical heat source and sink walls, a fire-proof clay model, and adiabatic plates on the top and bottom walls. With different geometrical aspect ratios of the fire-proof clay model, the heat energy distribution is throughly investigated. The model gave a good prediction of the microwave heating characteristics of fire-proof clay. The optimal shape of the fire-proof clay for given chamber geometry and microwave power is analyzed.

  • PDF

고강도 콘크리트의 섬유 혼입에 따른 크리프 특성 분석에 관한 연구 (An Analytic Study on the Creep Properties for Fibers Mixed of High Strength Concrete)

  • 박희곤;권해원;이보형;배연기;이재삼;정상진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2009년도 추계 학술논문 발표대회
    • /
    • pp.81-85
    • /
    • 2009
  • In the recent years, the high strength concrete has increasingly been used according to extending market of tall buildings. However, Ministry of Land, transport and Maritime Affairs was established by law with an alternative plan after June 2008 because of the weakness of high strength concrete accompanied spalling phenomena in fire. The mix design of concrete has to properly meet standards which are the spalling resistance of concrete and limited temperature of steel reinforcement. The fire proof concrete mixed fiber has widely been used to meet spalling safety on the many construction sites, the most researches about the fire proof concrete mixed fiber had being carried out focused on fire resistance, compressive strength and cast in place of concrete. But the most important thing is column shortening used the fire proof concrete within the vertical members. In this paper, the fire proof concrete filled spalling safety standards was experimented by required material when the column shortening is revised between normal concrete and fire proof concrete mixed fiber and then the results have done a comparative analysis. Also, The paper aimed to indicate a basic data for revision of column shortening of fire proof concrete.

  • PDF

한국 소방복의 착용만족도 및 착용자 의견에 관한 조사연구 (A Survey on the Actual Wearing Conditions of Fire Fighter's Uniform)

  • 정정숙;이연순
    • 대한가정학회지
    • /
    • 제37권11호
    • /
    • pp.75-83
    • /
    • 1999
  • To develope an efficient fire fighter’s uniform for the fire fighting work and body protection, this study examined the regulations of fire lighter’s uniform and surveyed the actual wearing conditions, satisfaction degree, preferred color and design others. The results are as follows; 1. As for the satisfaction degree, the degree was normal in ordinary, low in working uniform and heat-proof uniform and very low in water-proof uniform about its design, size, color and materials. 2. As for the color, red was preferred for the working uniform and water-proof uniform. Blue, yellow and green was preferred next for corking uniform and yellow and blue for water-proof uniform. 3. As for the design, fire fighters wanted partial revision of the present uniform. They preferred stretchy training wear style and overact style in order. For the water-proof uniform, they preferred hip-length suit and pants and next to it they liked flee-length suit, waist belt and overact in order. 4. As for the regulations of the uniform, they wanted some addition in casual uniform, water-proof pants and water-proof gloves, and some deletion in the thermal barrier of water-proof uniform and ordinary uniform. 5. As for the distribution of the uniforms, the use of coupons was highly preferred.

  • PDF

무기질계 영구거푸집의 내화성능에 관한 실험적 연구 (The Experimental Study of Inorganic Performanent내s of Fire Resistance Evaluation)

  • 김영진;백민수;정근호;김우재;정상진
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 가을 학술발표회 논문집
    • /
    • pp.495-500
    • /
    • 2002
  • The purpose of this study is to develop and to apply this permanent cement mortar form as one of those system forms to improve existing form's problems. (1) In the fire proof test with combined specimen, the fire proof covering including form section thickness is satisfied with the fire proof criterion. It is considered that form section thickness has no problem (2) The suitable method of normal pressure steam curing for the form's mass production is 4 hours in 65℃ considering production cost, the silica fume admixture is economic.

  • PDF

화장실 이용 피난공간의 방연시스템 제안 및 실규모 실험 (Study on Suggestion of Smoke-proof System Using a Restroom for a Refuge Space)

  • 김정엽;신현준
    • 한국화재소방학회논문지
    • /
    • 제26권5호
    • /
    • pp.61-66
    • /
    • 2012
  • 고층 건축물의 화장실은 평상시 악취 등의 배출을 위하여 송풍기와 풍도로 구성된 배기시스템이 설치되어 있으며 용수의 공급이 이루어지고 있어서 화염과 연기에 대한 방호기능만 추가되면 화재발생시 긴급한 피난공간으로 활용될 수 있다. 평상시 화장실의 배기용으로 사용하는 송풍시스템을 화재시 급기시스템으로 전환함으로써 기존 화장실의 연기에 대한 방호성능을 확보하는 화장실 방연시스템을 제안하였다. 또한 지상 5층 규모의 연기제어 실험동에 기존 화장실을 이용한 피난공간의 방연시스템에 대한 실규모 실험 시설을 설치하고, 화재발생 조건에 따른 작동성능 평가 실험을 수행하였으며 그 결과를 제시하였다.

목조 건축 문화재 적심부 실물화재 실험을 통한 연소 특성 연구 (A Study on Characteristics of Roof 'Jucsim' Structure Combustion Real Scale Fire Test on Wooden Structure Heritage Building)

  • 노삼규;함은규
    • 한국화재소방학회논문지
    • /
    • 제24권1호
    • /
    • pp.95-102
    • /
    • 2010
  • 본 연구에서는 목조한옥구조 적심부 실물화재 실험을 통하여 목조건축문화재 지붕 상부구조 내부의 연소특성을 분석하였다. 실험체는 숭례문 지붕 내부 구조의 특성을 고려하여 제작하였으며, 기와를 제외한 강회, 보토, 적심, 개판 순으로 구성하고 위치별로 열 측정 장치를 설치하였다. 첫 번째 실험은 목조건축 문화재의 적심 지붕구조를 가지는 경우 연소 및 화재 성상을 알아보았다. 두 번째 실험은 화염이 직접 접촉하는 서까래와 천정 개판 상 하부에 방염도료를 도색하여 방염도료 내화 성능을 알아보았다. 세 번째 실험은 적심부와 개판 사이에 방염천을 넣어 적심부 및 강회층에 화염 전파에 어떤 영향을 미치는지 알아보았다. 그 결과 목조 한옥구조 지붕의 적심부 화재 전파는 외부 화염의 제거 후에도 내부에 장시간에 걸쳐 연기와 화염이 계속 진행함을 보였다. 또한, 방염도료의 경우 내열효과를 보였으며, 방염천의 경우 화염전파온도를 $100^{\circ}C$ 이하로 유지할 때 적심부로부터 화염전파차단 효과를 보였다.

온도가열곡선 변화에 따른 콘크리트의 내화특성 (Properties of Fire Resistance in Tunnel Concrete According to the Changes of Heating Curve)

  • 배장춘;노상균;이찬영;이종석;이장화;한천구
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 춘계 학술발표회 제20권1호
    • /
    • pp.705-708
    • /
    • 2008
  • 본 연구에서는 화재시 터널 콘크리트의 안전성 확보를 목적으로, 내화공법 변화에 따른 내화특성을 분석한 것으로서, 그 결과를 요약하면 다음과 같다. RABT온도가열곡선에 따른 내화특성으로, 플레인 콘크리트는 초기의 극심한 고온에 의해 심한 폭렬현상이 발생하였고, 내화공법변화에 따라서는, 유기섬유를 혼입하는 방식과 보드방식의 경우는 폭렬이 방지되는 것으로 나타났으며, 스프레이 방식의 경우는 보강재인 메탈라스가 뿜칠재와 같이 탈락되면서 열응력 등에 의해 구조체 콘크리트가 철근이 노출되는 등 100mm이상 깊이의 심한 폭렬이 발생하였다. RWS 온도가열곡선에 따른 내화특성으로, 유기섬유를 혼입한 경우는 콘크리트 표면이 약 5mm이내 깊이의 융해현상이 발생하였고, 스프레이 방식의 경우는 뿜칠재가 박리되어 구조체 콘크리트가 철근이 노출되는 등 100mm이상 깊이의 심한 폭렬이 발생하였으며, 보드방식의 경우도 보드가 고온에 융해되면서 구조체 콘크리트가 고온에 직접 노출되어 전면적으로 탈락현상이 발생하였는데, 이와같은 특고온 가열조건에서는 특별한 내화대책수립이 필요한 것으로 사료된다.

  • PDF

막재료의 난연 및 방염성능 실험에 대한 연구 (Tests of Fire and Flame Retardant Performance for Membrane Materials)

  • 김기철;최광호
    • 한국공간구조학회논문집
    • /
    • 제16권2호
    • /
    • pp.55-60
    • /
    • 2016
  • The Membrane structure has a number of problems in the application of a fireproof code based on general buildings codes. Thus, the fireproof code of membrane structure is necessary to activate the construction of the membrane structure. Because it requires a systematic classification of fire retardant and flame proof performance of membrane material. Fire retardant and flame proof tests are conducted on membrane materials mostly used in current construction to propose the fire and flame retardant performance criteria of membrane materials. Fire and flame retardant tests results, PTFE membrane material with the glass fiber fabric have a limit-combustible performance. PVDF membrane material with the polyester fabric does not ensure the fire retardant performance, but this membrane material has the flame retardant performance of a thick fabric. Also, ETFE does not ensure the fire retardant performance, but this membrane material has the flame retardant of a thin fabric.

목조문화재 개판 상부에 설치하는 방염천의 화재전파 차단기능에 대한 실험연구 (An Experimental Study on the Capability of Arresting the Spread of a Fire of Fireproof Fabric Equipped over Ceiling Board of Wooden Cultural Properties)

  • 김현주;노삼규;김동철;함은구
    • 한국재난정보학회 논문집
    • /
    • 제8권3호
    • /
    • pp.297-303
    • /
    • 2012
  • 본 연구는 목조문화재 지붕 적심부의 화재전파 차단기능을 확보하기 위해 개판 상부에 설치하는 방염천의 차열성능을 알아보기 위한 실물모형 실험을 실시하여 방염천의 차열성능을 검증하고, 그 밖에 방염천의 설치방식에 따른(평형식과 접이식) 방화성능을 비교 분석하였다. 실험 결과, 방염천을 개판 상부에 평형식으로 설치한 경우 개판 하부온도가 $750^{\circ}C$일때 개판 상부온도가 $50^{\circ}C$$700^{\circ}C$ 정도의 온도차를 나타냈고 이는 방염천 미설치 시와 비교했을 때 개판 상부온도가 $580^{\circ}C{\sim}600^{\circ}C$ 정도 낮은 것으로, 방염천 설치로 인한 차열성능이 우수한 것으로 평가되었다. 방염천을 개판 상부에 접이식으로 설치한 경우 개판 하부온도가 $600^{\circ}C$일 때 개판 상부온도는 $65^{\circ}C$로 약 $530^{\circ}C$ 정도의 온도차를 보여 평형식으로 설치한 경우보다는 차열성능이 약간 떨어지는 것으로 나타났다.