• Title/Summary/Keyword: Fire Proof

Search Result 104, Processing Time 0.026 seconds

The experimental study on the Evaluation of fire-proof performance and bond characteristics for development of 3hours Fire-Proof paint (3시간 내화도료의 개발을 위한 내화성능 및 부착특성 평가에 관한 실험적 연구)

  • Kim, Soo-Young;Kim, sung-kil;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2012.11a
    • /
    • pp.63-64
    • /
    • 2012
  • Recently, Fire-proof performance of buildings becomes important to ensure safety. As a result, fire-proof paint is required for 3 hours. However, Experiments are only performed by standard KS F 2271 for estimation of fire-proof paint. Because there is no domestic estimation standard for performance of fire-proof paint as well. So estimation standard of fire-proof paint is needed to guarantee their performance for establishing quality system and to assure same performance for safety of people in the building from unpredicted fire accident. Owing to these reasons, we studied comparative estimation for quality performance of two kinds of fire-proof paint and bond performance.

  • PDF

A Study on the Characteristics of Heat Energy Distribution of Fire-Proof Clay with Microwave Heating Drying (MICROWAVE 가열 건조에 의한 내화 점토의 열에너지 분포 특성 연구)

  • Lee, S.J.;Kim, Y.J.
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.752-757
    • /
    • 2001
  • The characteristics of heat energy distribution on the fire-proof clay with microwave heating drying are numerically investigated using finite element method. The modelled regular hexahedron chamber$(50cm\times50cm\times50cm)$ filled with air consists of vertical heat source and sink walls, a fire-proof clay model, and adiabatic plates on the top and bottom walls. With different geometrical aspect ratios of the fire-proof clay model, the heat energy distribution is throughly investigated. The model gave a good prediction of the microwave heating characteristics of fire-proof clay. The optimal shape of the fire-proof clay for given chamber geometry and microwave power is analyzed.

  • PDF

An Analytic Study on the Creep Properties for Fibers Mixed of High Strength Concrete (고강도 콘크리트의 섬유 혼입에 따른 크리프 특성 분석에 관한 연구)

  • Park, Hee-Gon;Kwon, Hae-Won;Lee, Bo-Hyeong;Bae, Yeoun-Ki;Lee, Jae-Sam;Jung, Sang-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2009.11a
    • /
    • pp.81-85
    • /
    • 2009
  • In the recent years, the high strength concrete has increasingly been used according to extending market of tall buildings. However, Ministry of Land, transport and Maritime Affairs was established by law with an alternative plan after June 2008 because of the weakness of high strength concrete accompanied spalling phenomena in fire. The mix design of concrete has to properly meet standards which are the spalling resistance of concrete and limited temperature of steel reinforcement. The fire proof concrete mixed fiber has widely been used to meet spalling safety on the many construction sites, the most researches about the fire proof concrete mixed fiber had being carried out focused on fire resistance, compressive strength and cast in place of concrete. But the most important thing is column shortening used the fire proof concrete within the vertical members. In this paper, the fire proof concrete filled spalling safety standards was experimented by required material when the column shortening is revised between normal concrete and fire proof concrete mixed fiber and then the results have done a comparative analysis. Also, The paper aimed to indicate a basic data for revision of column shortening of fire proof concrete.

  • PDF

A Survey on the Actual Wearing Conditions of Fire Fighter's Uniform (한국 소방복의 착용만족도 및 착용자 의견에 관한 조사연구)

  • 정정숙;이연순
    • Journal of the Korean Home Economics Association
    • /
    • v.37 no.11
    • /
    • pp.75-83
    • /
    • 1999
  • To develope an efficient fire fighter’s uniform for the fire fighting work and body protection, this study examined the regulations of fire lighter’s uniform and surveyed the actual wearing conditions, satisfaction degree, preferred color and design others. The results are as follows; 1. As for the satisfaction degree, the degree was normal in ordinary, low in working uniform and heat-proof uniform and very low in water-proof uniform about its design, size, color and materials. 2. As for the color, red was preferred for the working uniform and water-proof uniform. Blue, yellow and green was preferred next for corking uniform and yellow and blue for water-proof uniform. 3. As for the design, fire fighters wanted partial revision of the present uniform. They preferred stretchy training wear style and overact style in order. For the water-proof uniform, they preferred hip-length suit and pants and next to it they liked flee-length suit, waist belt and overact in order. 4. As for the regulations of the uniform, they wanted some addition in casual uniform, water-proof pants and water-proof gloves, and some deletion in the thermal barrier of water-proof uniform and ordinary uniform. 5. As for the distribution of the uniforms, the use of coupons was highly preferred.

  • PDF

The Experimental Study of Inorganic Performanent내s of Fire Resistance Evaluation (무기질계 영구거푸집의 내화성능에 관한 실험적 연구)

  • 김영진;백민수;정근호;김우재;정상진
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.10a
    • /
    • pp.495-500
    • /
    • 2002
  • The purpose of this study is to develop and to apply this permanent cement mortar form as one of those system forms to improve existing form's problems. (1) In the fire proof test with combined specimen, the fire proof covering including form section thickness is satisfied with the fire proof criterion. It is considered that form section thickness has no problem (2) The suitable method of normal pressure steam curing for the form's mass production is 4 hours in 65℃ considering production cost, the silica fume admixture is economic.

  • PDF

Study on Suggestion of Smoke-proof System Using a Restroom for a Refuge Space (화장실 이용 피난공간의 방연시스템 제안 및 실규모 실험)

  • Kim, Jung-Yup;Shin, Hyun-Joon
    • Fire Science and Engineering
    • /
    • v.26 no.5
    • /
    • pp.61-66
    • /
    • 2012
  • In restroom on high-rise building, exhaust system comprising the blower and duct is installed to discharge the odor and the water is suppled. Thus the restroom with fire and flame protection system may be used as refuge area in a fire situation. The study presents the smoke-proof system which operates such that the exhaust system to discharge the odor is converted to air supply system and appropriate pressure difference between the restroom and the accommodation is maintained. Also real-scale test facilities of smoke-proof system for refuge space using a restroom are installed on 5-story smoke control test building and experiments for evaluating the operational performance of smoke-proof system are carried out.

A Study on Characteristics of Roof 'Jucsim' Structure Combustion Real Scale Fire Test on Wooden Structure Heritage Building (목조 건축 문화재 적심부 실물화재 실험을 통한 연소 특성 연구)

  • Roh, Sam-Kew;Ham, Eun-Gu
    • Fire Science and Engineering
    • /
    • v.24 no.1
    • /
    • pp.95-102
    • /
    • 2010
  • The combustion characteristics of roof 'Jucsim' structure was analysed using real scale fire test on wooden structure heritage building. the fire test model was made to consider roof timberling internal structure for a Sunglemun. Structure of test body layed lime, soil, 'Jucsin' and ceiling board excepting roof tile to find heat propagation process by setting thermocouples. The first test to find fire growth and heat propagation process in the part of ceiling. The second test organized to find the efficiency of fire proof paint between ceiling board and inside of Jucsim structure. The third test try to get the performance level of fire proof fabric with the same manner. The result showed from the test proof the heavy smoke exposure with limited effect of fire proof paint however, reliable fire resistance effect showed in case of fire proof fabric.

Properties of Fire Resistance in Tunnel Concrete According to the Changes of Heating Curve (온도가열곡선 변화에 따른 콘크리트의 내화특성)

  • Pei, Chang-Chun;Noh, Sang-Kyun;Lee, Chan-Young;Lee, Jong-Suk;Lee, Jang-Hwa;Han, Cheon-Goo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.705-708
    • /
    • 2008
  • To obtain tunnel concrete safety in case of fire, this study analyzed fire proof characteristics by fire proof method change, and the results are as follows. As a fire proof characteristics by RABT temperature heating curve, plain concrete experienced severe spalling by initial extremely high temperature. In view of fire proof method, in the cases of organic fiber mixing method and board method, spalling was prevented, and in the case of spray method, severe spalling of over 100mm depth occurred along with exposure of structural concrete including spray coat by heat stress, etc while metal lath, the stiffener, falls off. As for fire proof characteristics by RWS temperature heating curve, in case of organic fiber inclusion, concrete surface experienced fusion of within 5mm, while in the case of spray method, spray coat was severely spalled to a depth of over 100mm causing structural body concrete to expose its reinforcement, and also in the case of board method, board was fused by high temperature, causing structural body concrete be directly exposed to high temperature, which triggered overall fall-off phenomenon, so in such extraordinary high temperature heating condition, establishment of special fire proof measures is needed.

  • PDF

Tests of Fire and Flame Retardant Performance for Membrane Materials (막재료의 난연 및 방염성능 실험에 대한 연구)

  • Kim, Gee-Cheol;Choi, Kwang-Ho
    • Journal of Korean Association for Spatial Structures
    • /
    • v.16 no.2
    • /
    • pp.55-60
    • /
    • 2016
  • The Membrane structure has a number of problems in the application of a fireproof code based on general buildings codes. Thus, the fireproof code of membrane structure is necessary to activate the construction of the membrane structure. Because it requires a systematic classification of fire retardant and flame proof performance of membrane material. Fire retardant and flame proof tests are conducted on membrane materials mostly used in current construction to propose the fire and flame retardant performance criteria of membrane materials. Fire and flame retardant tests results, PTFE membrane material with the glass fiber fabric have a limit-combustible performance. PVDF membrane material with the polyester fabric does not ensure the fire retardant performance, but this membrane material has the flame retardant performance of a thick fabric. Also, ETFE does not ensure the fire retardant performance, but this membrane material has the flame retardant of a thin fabric.

An Experimental Study on the Capability of Arresting the Spread of a Fire of Fireproof Fabric Equipped over Ceiling Board of Wooden Cultural Properties (목조문화재 개판 상부에 설치하는 방염천의 화재전파 차단기능에 대한 실험연구)

  • Kim, Hyunju;Roh, Sam-Kew;Kim, Dong Cheol;Ham, Eun-Gu
    • Journal of the Society of Disaster Information
    • /
    • v.8 no.3
    • /
    • pp.297-303
    • /
    • 2012
  • This study examines the isolation-heat performance of fire proof fabric that is equipped over ceiling board in order to secure the capability of arresting the spread of a fire at roof 'Jucsim' structure of Wooden Cultural Properties. For this examination, I conduct experiments with the model and compare two construction methods of fire proof fabric, or flat-type, folding-type. The experiments show the following results. In case of installing the fire proof fabric in flat-type, when the temperature under the ceiling board is $750^{\circ}C$, the temperatures over the ceiling board is $50^{\circ}C$; the difference is $700^{\circ}C$. Compared with the case of removing fire proof fabric, the temperature over the ceiling board is lower by approximately $580^{\circ}C{\sim}600^{\circ}C$. Therefore it can be said that the construction of fire proof fabric enhances the isolation-heat performance. In case of installing the fire proof fabric in folding-type, when the temperature under the ceiling board is $600^{\circ}C$, the temperatures over the ceiling board is $65^{\circ}C$; the difference is approximately $530^{\circ}C$. Thus its isolation-heat performance is a little inferior to the flat-type equipment.