• Title/Summary/Keyword: Fire Monitoring System

Search Result 266, Processing Time 0.023 seconds

PID Controled UAV Monitoring System for Fire-Event Detection (PID 제어 UAV를 이용한 발화 감지 시스템의 구현)

  • Choi, Jeong-Wook;Kim, Bo-Seong;Yu, Je-Min;Choi, Ji-Hoon;Lee, Seung-Dae
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.15 no.1
    • /
    • pp.1-8
    • /
    • 2020
  • If a dangerous situation arises in a place where out of reach from the human, UAVs can be used to determine the size and location of the situation to reduce the further damage. With this in mind, this paper sets the minimum value of the roll, pitch, and yaw using beta flight to detect the UAV's smooth hovering, integration, and derivative (PID) values to ensure that the UAV stays horizontal, minimizing errors for safe hovering, and the camera uses Open CV to install the Raspberry Pi program and then HSV (color, saturation, Brightness) using the color palette, the filter is black and white except for the red color, which is the closest to the fire we want, so that the UAV detects the image in the air in real time. Finally, it was confirmed that hovering was possible at a height of 0.5 to 5m, and red color recognition was possible at a distance of 5cm and at a distance of 5m.

Computer modelling of fire consequences on road critical infrastructure - tunnels

  • Pribyl, Pavel;Pribyl, Ondrej;Michek, Jan
    • Structural Monitoring and Maintenance
    • /
    • v.5 no.3
    • /
    • pp.363-377
    • /
    • 2018
  • The proper functioning of critical points on transport infrastructure is decisive for the entire network. Tunnels and bridges certainly belong to the critical points of the surface transport network, both road and rail. Risk management should be a holistic and dynamic process throughout the entire life cycle. However, the level of risk is usually determined only during the design stage mainly due to the fact that it is a time-consuming and costly process. This paper presents a simplified quantitative risk analysis method that can be used any time during the decades of a tunnel's lifetime and can estimate the changing risks on a continuous basis and thus uncover hidden safety threats. The presented method is a decision support system for tunnel managers designed to preserve or even increase tunnel safety. The CAPITA method is a deterministic scenario-oriented risk analysis approach for assessment of mortality risks in road tunnels in case of the most dangerous situation - a fire. It is implemented through an advanced risk analysis CAPITA SW. Both, the method as well as the resulting software were developed by the authors' team. Unlike existing analyzes requiring specialized microsimulation tools for traffic flow, smoke propagation and evacuation modeling, the CAPITA contains comprehensive database with the results of thousands of simulations performed in advance for various combinations of variables. This approach significantly simplifies the overall complexity and thus enhances the usability of the resulting risk analysis. Additionally, it provides the decision makers with holistic view by providing not only on the expected risk but also on the risk's sensitivity to different variables. This allows the tunnel manager or another decision maker to estimate the primary change of risk whenever traffic conditions in the tunnel change and to see the dependencies to particular input variables.

Quantitative Analysis of CO2 Reduction by Door-opening in the Subway Cabin (출입문 개폐에 의한 전동차 객실 CO2 저감효과 분석)

  • Kwon, Soon-Bark;Cho, Young-Min;Park, Duck-Shin;Park, Eun-Young
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.24 no.2
    • /
    • pp.153-161
    • /
    • 2008
  • The guidelines for indoor air quality of public transportations such as subway, train and bus was presented by Korean Ministry of Environment last end of year 2006 based on the great consequence of indoor air quality in daily life. Two main parameters, carbon dioxide($CO_2$) and particulate matters smaller than $10\;{\mu}m(PM_{10})$, were selected as index pollutants for the management of indoor air quality. The former pollutant, $CO_2$, is regarded as index of ventilation status and the major source of $CO_2$ in the train or subway is the exhalation of passengers. It is publically perceived that the high $CO_2$ concentration in a crowded subway will be reduced and ventilated with outdoor air by door-opening taken every 2 or 3 minutes when the train stops each station. However, there has not been any scientific proof and quantitative information on the effect of door-opening on the $CO_2$ reduction by ventilation with outdoor air. In this study, $CO_2$ concentration and number of passengers were measured at each station on the 3 lines of Korail metropolitan subway. In order to evaluate the effect of $CO_2$ reduction by door opening, the theoretical approach using the $CO_2$ balance equation was performed. By comparing the predicted data with monitoring one, the optimum $CO_2$ dilution factor was determined. For the first time, it was quantified that about 35% of $CO_2$ concentration in the subway indoor was removed by the door-opening at each station.

IEEE 802.15.4 MAC-based Location-ID Exchange Protocol for Realizing Micro-Cell Connectionless Location- Awareness Services

  • Kim, Baek-Gyu;Kang, Soon-Ju
    • Journal of Computing Science and Engineering
    • /
    • v.2 no.4
    • /
    • pp.412-427
    • /
    • 2008
  • We propose ID-exchange protocol for Connectionless Location-Awareness Service (CLAS) to locate mobile nodes in indoor sensor network. When adapting location-awareness service to sensor network, the target system must be designed in accordance with various metrics which reflect the system requirement. We especially consider sustainability of the existing service which has been provided for its original purpose, such as environmental monitoring. The detailed meaning of sustainability here is that, even if location-awareness service is newly added to the existing service, the system must be assured to retain a stable network condition, and to deal with newly caused traffic properly. The CLAS ID-exchange protocol is especially designed for fixture and mobile nodes communication to achieve these properties. The protocol operates on 802.15.4 MAC layer to make mobile node work independently of the procedure to build routing table of fixture node, so a stable routing condition can be achieved even if there are many mobile nodes. Moreover, the dedicated frequency channel is assigned only for this protocol, so that traffic caused by location-awareness service can be distributed to another channel. A real system adapting the protocol was implemented to monitor fire and authorities' positions. We verified the overhead and elapsed time for location-awareness. The result shows the proposed protocol has a high performance in detecting speed, traffic distribution, and stability of overall network.

Implementation of Leakage Monitoring System Using ZigBee (ZigBee를 적용한 누전상태 모니터링시스템 구현)

  • Ju, Jae-han;Na, Seung-kwon
    • Journal of Advanced Navigation Technology
    • /
    • v.21 no.1
    • /
    • pp.107-112
    • /
    • 2017
  • In recent years, electric shock accidents due to electric leakage currents of household appliances such as computers, TVs, refrigerators, and LED lights are continuously occurring in homes and industrial buildings. And it is not easy to check the leakage current of each household appliances connected in parallel at the rear end of the module. In addition, the leakage current flowing through the path of the normal current other than the existing current leakage circuit breakers are installed in the distribution box, only the function to cut off the power when the leakage. Therefore, there are various disasters such as electric shock and fire caused by short circuit of household appliances, and the risk of such leakage current is seriously presented. In this paper, we propose a method to implement a leakage monitoring system that can be monitored at all times using Zigbee communication based on IEEE 80215.4, which has advantages in low power and low cost among short range wireless communication systems.

A Monitoring System for Working Environments Using Wireless Sensor Networks (무선 센서 네트워크를 이용한 작업환경 모니터링 시스템)

  • Jung, Sang-Joon;Chung, Youn-Ky
    • Journal of Korea Multimedia Society
    • /
    • v.12 no.10
    • /
    • pp.1478-1485
    • /
    • 2009
  • A sensor network which is composed of a large number of sensors that perform various sensing is applied in a variety of fields. The sensor networks can be widely used for various application area like as home automation, fire detection and security area. Development of new sensor to have appropriate functions and deployment of networks for suitable application are served actively. In this paper, we design and implement a system that monitors various factory facilities by deploying sensor network at a working place which threatens the worker's safety. A sensor node reports its sensing data like as temperature and humidity to monitor facilities to a sink node. And the server which is connect to the sink node gathers and provides information by user interface. In addition, digital data which are generated at a work place can be transferred via the sensor network to increase the efficiency of works. The proposed sensor network provides the convenience of working, since it is deployed at a garbage collection company to monitor a temperature and humidity of garbage and to transmit data about the weight of trucks which enters the company.

  • PDF

The Control System of Wood Pellet Boiler Based on Home Networks (홈 네트워크 기반의 펠릿 활용 난방 보일러 제어시스템)

  • Lee, Sang-Hoon
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.15 no.1
    • /
    • pp.15-22
    • /
    • 2014
  • This paper presents the implementation of a control system of pellet boiler using wood pellet as carbon neutral material. The system also has the additional features to provide remote controlling and monitoring based on home networking technology through either public switched telephone networks or mobile communication networks. It consists of three kinds of sub-modules; a main controller provides basic and additional features such as a setting of temperature, a supplying of wood pellet, a controlling of ignition and fire-power, and a removing of soot. The second is temperature controller of individual rooms which is connected to the main controller through RS-485 links. And interface modules with PSTN and mobile networks can support remote controlling and monitoring the functions. The test results under the heating area of $172m^2$ show a thermal efficiency of 93.6%, a heating power of 20,640kcal/hr, and a fuel consumption of 5.54kg/hr. These results are superior to those of the conventional pellet boilers. In order to obtain the such high performance, we newly applied a 3-step ignition flow, a flame detection by $C_dS$ sensor, and a fire-power control by fine controlling of shutter to our pellet boiler.

Comparison of Classification Rate for PD Sources using Different Classification Schemes

  • Park Seong-Hee;Lim Kee-Joe;Kang Seong-Hwa
    • Journal of Electrical Engineering and Technology
    • /
    • v.1 no.2
    • /
    • pp.257-262
    • /
    • 2006
  • Insulation failure in an electrical utility depends on the continuous stress imposed upon it. Monitoring of the insulation condition is a significant issue for safe operation of the electrical power system. In this paper, comparison of recognition rate variable classification scheme of PD (partial discharge) sources that occur within an electrical utility are studied. To acquire PD data, five defective models are made, that is, air discharge, void discharge and three types of treeinging discharge. Furthermore, these statistical distributions are applied to classify PD sources as the input data for the classification tools. ANFIS shows the highest rate, the value of which is 99% and PCA-LDA and ANFIS are superior to BP in regards to other matters.

Development of the Circuit Breaker with Data Processing Function and Wireless-communication Function (데이터 처리 및 무선통신기능을 갖는 회로차단기 개발 연구)

  • Kim, Gi-Hyun;Lee, Sang-Ick;Shin, Seong-Su;Bae, Seok-Myung;Joo, Nam-Kyu
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.8
    • /
    • pp.1617-1621
    • /
    • 2011
  • In this paper, in order to reduce the electrical disaster such as electrical fire at traditional markets, we need to develop the circuit breaker which is able to monitor the power status of electrical equipments. Therefore, for solving the those problems, we developed the detection censor(ZCT, CT) and equipment of data analysis and transmission. The detection censor and equipment is able to monitor the electrical equipments condition(over current, leakage current, arc, etc.). We constructed Test-Bed for testing reliability of the circuit breaker and obtained certification. And we tested the over current, leakage current and arc under the normal condition. This paper will be used to the data for development an cabinet panel which is able to monitor the actual loads.

Study on Disaster Prevention and Monitoring System for Forest Fire Using Multi-Source GSIS Data (GSIS 다중자료를 이용한 산불피해 분석에 관한 연구)

  • Lee Kang-Won;Gang Jun-Muk
    • Proceedings of the Korean Association of Geographic Inforamtion Studies Conference
    • /
    • 2006.05a
    • /
    • pp.193-198
    • /
    • 2006
  • 최근의 동남아시아 발생한 지진해일(쓰나미)과 미국 뉴올리언즈 지역의 허리케인으로 등의 재난으로 인해 막대한 인명과 경제적 피해가 전 세계적으로 빈번히 발생하고 있다. 우리나라도 폭설과 태풍, 산불로 인한 피해가 해마다 증가하고 있는 실정이다. 본 연구에서는 '05년 양양지역의 대규모 산불재해지역을 중심으로 항공레이저측량, GPS/INS항공사진측량 등의 다중센서를 이용하여 GSIS자료를 취득하였다 이를 통해 수치지형도, 수치고도모형, 수치외관모형, 디지털 영상, 근적외선 영상을 처리하였으며, 과거 항공사진자료와의 비교 분석을 통해 정확한 피해면적과 피해량, 향후 산사태가 발생할 수 있는 지역 예측 및 식생에 대한 피해정도와 회생가능성을 분석하였다.

  • PDF