• Title/Summary/Keyword: Fire Monitoring System

Search Result 264, Processing Time 0.03 seconds

ICT Medical Service Provider's Knowledge and level of recognizing how to cope with fire fighting safety (ICT 의료시설 기반에서 종사자의 소방안전 지식과 대처방법 인식수준)

  • Kim, Ja-Sook;Kim, Ja-Ok;Ahn, Young-Joon
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.9 no.1
    • /
    • pp.51-60
    • /
    • 2014
  • In this study, ICT medical service provider's level of knowledge fire fighting safety and methods on coping with fires in the regions of Gwangju and Jeonam Province of Korea were investigated to determine the elements affecting such levels and provide basic information on the manuals for educating how to cope with the fire fighting safety in medical facilities. The data were analyzed using SPSS Win 14.0. The scores of level of knowledge fire fighting safety of ICT medical service provider's were 7.06(10 point scale), and the scores of level of recognizing how to cope with fire fighting safety were 6.61(11 point scale). level of recognizing how to cope with fire fighting safety were significantly different according to gender(t=4.12, p<.001), age(${\chi}^2$=17.24, p<.001), length of career(${\chi}^2$=22.76, p<.001), experience with fire fighting safety education(t=6.10, p<.001), level of subjective knowledge on fire fighting safety(${\chi}^2$=53.83, p<.001). In order to enhance the level of understanding of fire fighting safety and methods of coping by the ICT medical service providers it is found that: self-directed learning through avoiding the education just conveying knowledge by lecture tailored learning for individuals fire fighting education focused on experiencing actual work by developing various contents emphasizing cooperative learning deploying patients by classification systems using simulations and a study on the implementation of digital anti-fire monitoring system with multipoint communication protocol, a design and development of the smoke detection system using infra-red laser for fire detection in the wide space, video based fire detection algorithm using gaussian mixture mode developing an education manual for coping with fire fighting safety through multi learning approach at the medical facilities are required.

A Study on the Control System of Plant Growth Using IT Convergence Technology (IT 융합기술을 이용한 식물생장 제어시스템 연구)

  • Kim, Min-Soo;Jee, Seung-Wook;Kim, Min-Kyu;Cho, Young-Chang
    • Journal of IKEEE
    • /
    • v.22 no.4
    • /
    • pp.959-964
    • /
    • 2018
  • In this study, a study is conducted on a monitoring system that can control the environment of plants using sensors in conjunction with the LED light system and the plant growth control system. To verify the performance of the developed plant growth system, an experiment was conducted on the characteristics of energy efficiency, data transmission rate, and light volume control. The experiment resulted in a satisfactory result by controlling more than 80% energy efficiency, 1Mb/sec wireless communication speed, and 5 levels of optical control. The proposed system can be applied to LED plant facilities and will contribute to the automation of agriculture by organizing an automated system for production efficiency and labor cost reduction for future commercialization.

A Study on the Application of RTLS Technology for the Automation of Spray-Applied Fire Resistive Covering Work (뿜칠내화피복 작업 자동화시스템을 위한 RTLS 기술 적용에 관한 연구)

  • Kim, Kyoon-Tai
    • Journal of the Korea Institute of Building Construction
    • /
    • v.9 no.5
    • /
    • pp.79-86
    • /
    • 2009
  • In a steel structure, spray-applied fire resistive materials are crucial in preventing structural strength from being weakened in the event of a fire. The quality control of such materials, however, is difficult for manual workers, who can frequently be in short supply. These skilled workers are also very likely to be exposed to environmental hazards. Problems with construction work such as this, which are specifically the difficulty of achieving quality control and the dangerous nature of the work itself, can be solved to some degree by the introduction of automated equipment. It is, however, very difficult to automate the work process, from operation to the selection of a location for the equipment, as the environment of a construction site has not yet been structured to accommodate automation. This is a fundamental study on the possibility of the automation of spray-applied fire resistive coating work. In this study, the linkability of the cutting-edge RTLS to an automation system is reviewed, and a scenario for the automation of spray-applied fire resistive coating work and system composition is presented. The system suggested in this study is still in a conceptual stage, and as such, there are many restrictions still to be resolved. Despite this fact, automation is expected to have good effectiveness in terms of preventing fire from spreading by maintaining a certain level of strength at a high temperature when a fire occurs, as it maintains the thickness of the fire-resistive coating at a specified level, and secures the integrity of the coating with the steel structure, thereby enhancing the fire-resistive performance. It also expected that if future research is conducted in this area in relation to a cutting-edge monitoring TRS, such as the ubiquitous sensor network (USN) and/or building information model (BIM), it will contribute to raising the level of construction automation in Korea, reducing costs through the systematic and efficient management of construction resources, shortening construction periods, and implementing more precise construction

Modeling of the T.C.M.S. using Power Line Carrier in Railway

  • Song, Y.S.;Lee, S.G.;Shin, S.K.;Han, S.H.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.2147-2150
    • /
    • 2003
  • Recently, many technologies of the P.L.C (Power Line Carrier) are introduced for an efficient communication. P.L.C communication sends information in the carrier signals by conduction over the power wire. An arc detector is proposed in this paper for the effective transmission. The Power Line Carrier has an advantage in low cost because it uses existent power line. It can be easily applied anywhere that a power line socket is available. But the P.L.C. is very noisy, because many electronic devices in generate electronic noise in modulated signals. This problem should be considered carefully in the design of the arc detector system using P.L.C in railway. The proposed system can be applied for monitoring the arc detector system and the arc locator system in railway. Hence the system will be able to exchange the arc information to be T.C.M.S. (Train Control Management System), bogies and even between a station and trains in railway and use to suspicion fire in train.

  • PDF

A Sensor Data Management System for USN based Fire Detection Application (USN 기반의 화재감시 응용을 위한 센서 데이터 처리 시스템)

  • Park, Won-Ik;Kim, Young-Kuk
    • Journal of the Korea Society of Computer and Information
    • /
    • v.16 no.5
    • /
    • pp.135-145
    • /
    • 2011
  • These days, the research of a sensor data management system for USN based real-time monitoring application is active thanks to the development and diffusion of sensor technology. The sensor data is rapidly changeable, continuous and massive row level data. However, end user is only interested in high level data. So, it is essential to effectively process the row level data which is changeable, continuous and massive. In this paper, we propose a sensor data management system with multi-analytical query function using OLAP and anomaly detection function using learning based classifier. In the experimental section, we show that our system is valid through the some experimental scenarios. For the this, we use a sensor data generator implemented by ourselves.

The study of quantitative analysis for noxious gases of plastic materials by remote sensing open path FT-IR spectrometer (원격 측정용 개방 경로형 FT-IR spectrometer를 사용하여 플라스틱 재료의 유해 가스 정량 분석에 관한 연구)

  • Cho, Nam-Wook;Cho, Won-Bo;Kim, Hyo-Jin
    • Analytical Science and Technology
    • /
    • v.25 no.4
    • /
    • pp.230-235
    • /
    • 2012
  • It is to use many plastic materials as living essential goods. But when the fire is happened, owing to noxious gases, many men should be injured. Therefore as the noxious gases are measured by open path FT-IR spectrometer as remote monitoring, the demage of men could be minimized. Such this system consists of a Fourier transform spectrometer and infrared lamp fitted to long length. The study was to do the quantitative analysis on CO, $NO_2$, HCl, HF gas by remote monitoring open path FT-IR spectrometer. And the method of it should use MLR (multiple linearity regression) method. As result, It was confirmed to be more than 0.95 as $R^2$ of MLR. And then Urethane and PVC of plastic materials selected was burned, the concentration of polluted gases were measured by remote monitoring method.

On-off controllable RNA hybrid expression vector for yeast three-hybrid system

  • Bak, Geunu;Hwang, Se-Won;Ko, Ye-Rim;Lee, Jung-Min;Kim, Young-Mi;Kim, Kyung-Hwan;Hong, Soon-Kang;Lee, Young-Hoon
    • BMB Reports
    • /
    • v.43 no.2
    • /
    • pp.110-114
    • /
    • 2010
  • The yeast three-hybrid system (Y3H), a powerful method for identifying RNA-binding proteins, still suffers from many false positives, due mostly to RNA-independent interactions. In this study, we attempted to efficiently identify false positives by introducing a tetracycline operator (tetO) motif into the RPR1 promoter of an RNA hybrid expression vector. We successfully developed a tight tetracycline-regulatable RPR1 promoter variant containing a single tetO motif between the transcription start site and the A-box sequence of the RPR1 promoter. Expression from this tetracycline-regulatable RPR1 promoter in the presence of tetracycline-response transcription activator (tTA) was positively controlled by doxycycline (Dox), a derivative of tetracycline. This on-off control runs opposite to the general knowledge that Dox negatively regulates tTA. This positively controlled RPR1 promoter system can therefore efficiently eliminate RNA-independent false positives commonly observed in the Y3H system by directly monitoring RNA hybrid expression.

Implementation of the Smart Emergency Medical System (스마트 응급의료 시스템 구현)

  • Park, Hong-Jin
    • Journal of Advanced Navigation Technology
    • /
    • v.15 no.4
    • /
    • pp.646-654
    • /
    • 2011
  • Recently, the task in which the number of people of the emergency medical technician whom it boards the ambulance is unreasonably insufficient and in which the fire fighter one person gets in the ambulance and which transfers the patient comes into question often. When the emergency patient is generated, it has to transfer to the special hospital in which above anything else, the measure which is quick and exact is needed and where there is the medical device which is suitable for particularly, the patient. This paper implementations the emergency medical system by the smart phone. The implemented system monitors the heart beat of the patient the monitoring among the patient transport with the real-time type. It can grasp the medical history information of the patient, and etc. in the past. And the system provides the emergency hospital which the patient requires and the pre-hospital phase provides the environment in which the disposition which is quick and efficient is possible to the emergency patient.

A Study on the Development of ICT-based Disaster Prevention Monitoring System for Shipbuilding Safety (선박 안전 건조를 위한 ICT 기반 재해방지 감시시스템 개발에 관한 연구)

  • Kim, Gi-Back;Kim, Nam-Ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2014.10a
    • /
    • pp.785-788
    • /
    • 2014
  • Even though Korea is No.1 shipbuilding country around the world, there have been a lot of accident and man-made calamity incurring in shipyards these days. Therefore most of Korea major shipyard and mid-small size shipyard deeply agonize about safety management countermeasure. As a result of it, many shipyards pour their effort on developing man watching system, PF wireless communication system, portable measuring system to prevent from accident such as fire, suffocation incurring. In this paper, analyze conventional accident & man-made calamity preventing system adopted by most of shipyard and enable the user to watch accident for 24 hours and notify it to user when it is incurring through state of the art ICT technology. And as a result of it the user can prevent the accident and man-made calamity at the beginning.

  • PDF

PID Controled UAV Monitoring System for Fire-Event Detection (PID 제어 UAV를 이용한 발화 감지 시스템의 구현)

  • Choi, Jeong-Wook;Kim, Bo-Seong;Yu, Je-Min;Choi, Ji-Hoon;Lee, Seung-Dae
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.15 no.1
    • /
    • pp.1-8
    • /
    • 2020
  • If a dangerous situation arises in a place where out of reach from the human, UAVs can be used to determine the size and location of the situation to reduce the further damage. With this in mind, this paper sets the minimum value of the roll, pitch, and yaw using beta flight to detect the UAV's smooth hovering, integration, and derivative (PID) values to ensure that the UAV stays horizontal, minimizing errors for safe hovering, and the camera uses Open CV to install the Raspberry Pi program and then HSV (color, saturation, Brightness) using the color palette, the filter is black and white except for the red color, which is the closest to the fire we want, so that the UAV detects the image in the air in real time. Finally, it was confirmed that hovering was possible at a height of 0.5 to 5m, and red color recognition was possible at a distance of 5cm and at a distance of 5m.