• Title/Summary/Keyword: Fire Monitoring System

Search Result 266, Processing Time 0.031 seconds

Design and Implementation of a Wireless Sensor Network Protocol for a Smart Power Outlet System (스마트 아웃렛 시스템을 위한 무선 센서네트워크 프로토콜 설계 및 구현)

  • Chung, Han-Su;Moon, Jung-Ho;Park, Sung-Wook;Lee, Hyung-Bong;Park, Lae-Jeong;Chung, Tae-Yun
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.7 no.6
    • /
    • pp.291-300
    • /
    • 2012
  • This paper deals with the design and implementation of wireless sensor network protocol for smart power outlet system capable of fire detection, power monitoring, standby power cutoff, and home automation. The proposed protocol integrates both the CSMA and the TDMA protocols for low power consumption and good scalability. A prototype smart power outlet system employing the proposed protocol and a simple home automation network including the power outlet system have been implemented for evaluating the feasibility of the proposed protocol The result shows that the proposed protocol allows the power outlet system to be scalable with high power efficiency.

A Study on Egress Algorithm for High-rise Buildings Using Egress Simulation (피난시뮬레이션을 이용한 초고층건물의 피난 알고리즘 연구)

  • Kim, Won Kook;Seo, Dong Hyun
    • Fire Science and Engineering
    • /
    • v.32 no.1
    • /
    • pp.33-39
    • /
    • 2018
  • When the fire in the high-rise building was not extinguished in its early stage and propagated over its origin, safe egress becomes one of the most important factor to minimize the casualties. Recently fire protection for high-rise building has been reinforced after experiencing the series of disastrous fires. But, we still find many high-rise buildings do not comply with those reinforcement. And also there is a possibility of failure of reinforced fire protection system. Under these situation safe egress guide would be the final layer of protection. In this study existing egress methods were identified and evaluated. According the result of study, priority in egress should be given to the tenants on the floor of fire origin and floors exposed to the risk of fire. Then, the rest of the tenants can be evacuated simultaneously. Floors exposed in fire risk shall be determined by fire tests and/or fire simulations. But, the result of fire monitoring shall override preliminary estimations. Egress time for each algorithm was estimated by egress simulation and the result was compared. There was a little difference in egress time between total egress and phased egress, and a big difference between using stairs only and using elevators and stairs together. to a constant thickness between layers constituting a firefighter's protective clothing should be considered in the future.

Development of Wireless Base Station Re4mote Monitoring System Using IoT Based on Cloud Server (클라우드 서버 기반 IoT를 이용한 무선기지국 원격 감시시스템 개발)

  • Lee, Yang-Weon;Kim, Chul-Won
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2018.05a
    • /
    • pp.491-494
    • /
    • 2018
  • Radio base stations, which are widely distributed across large areas, have many difficulties in managing them. Unmanned radio base stations in remote mountains are having a hard time accessing them in case of emergencies. Major telephone service providers only remotely control incoming and outgoing information and local small business partners responsible for maintaining actual facilities do not possess such technologies, so they are each checked during field visits. In this study, in order to monitor temperature, humidity, fire condition, and power operation at a wide range of radio base stations, real-time monitoring is carried out at the office of Klaus server through real-time monitoring.

  • PDF

Oxygen contents monitoring in the building for launch and test facilities (발사대 및 시험장 건물 내의 산소농도 관리)

  • Kim, Ji-Hoon;Yoo, Byung-Il;Cho, Sang-Yeon;Kang, Sun-Il;Oh, Seung-Hyub
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.246-249
    • /
    • 2009
  • Test and launch facilities which use oxygen as the propellant of a launch vehicle have hazards of fire and explosion by the leakage of oxygen. Also, the personnel operating the facilities, which use the high-pressured gases like nitrogen and helium in the closed room, is exposed to the hazard of death from suffocation. Consequently, we should keep out of the hazards and the accidents by monitoring the contents of oxygen in the air. The method and the system construction for monitoring oxygen contents in the air and the results from its application to Naro space center are described on this paper.

  • PDF

Monitoring of Carbon Monoxide using MOPITT: Data Processing and Applications (인공위성 센서 MOPITT를 이용한 일산화탄소 모니터링: 자료처리 및 응용)

  • Choi, Sung-Deuk;Chang, Yoon-Seok
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.22 no.6
    • /
    • pp.940-953
    • /
    • 2006
  • The major source of carbon monoxide (CO) at the Earth's surface is the incomplete combustion of biomass and fossil fuels. Because the global lifetime of CO is about two months, it can be used as a tracer for pollution from anthropogenic activities and biomass hurtling. In this paper, we introduced the principle and algorithm of the Measurement of Pollution in the Troposphere (MOPITT) instrument for global CO monitoring. The MOPITT instrument, which was launched on the Satellite Terra in 1999, measures CO column and mixing ratio based on gas correlation radiometry. CO levels can be determined by a retrieval algorithm based on the maximum likelihood method minimizing the difference between observed and modeled radiances. MOPITT level 2 data (HDF format) can be downloaded through the Earth Observing System (EOS) data gateway of NASA. ASCII files of CO parameters can be extracted from HDF files, and then temporal and spatial distributions can be obtained. Finally, we showed an example of CO monitoring in April 2000. The locations of forest fires and distribution of MOPITT CO clearly indicated that not only anthropogenic emissions but also forest fires play an important role in CO levels and global CO distribution. Our introduction to MOPITT and the example of MOPITT data interpretation would be helpful for scientists who want to use the EOS data.

DFT-based Power System Frequency Estimation using Two Digital Filters for Noise Effect Reduction (잡음영향의 저감을 위한 두 디지털 필터들의 사용에 의한 DFT 기반의 계통주파수 추정)

  • Hwang, Jin Kwon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.7
    • /
    • pp.891-897
    • /
    • 2013
  • The power system frequency plays an important role in monitoring and controlling the power system. The frequency can be measured through discrete Fourier transform (DFT) coefficients of its positive fundamental frequency. The accuracy of the frequency estimate is severely affected by noise in the power system signal and the leakage effect of the negative fundamental frequency in DFT. This paper proposes a DFT-based frequency estimation algorithm to cope with the noise as well as the leakage effect. In this algorithm, two suitable digital filters are introduced to reduce efficiently frequency estimate error due to the noise. These filters are designed to use a digital bandpass filter and a second-degree integrator. The effectiveness of the proposed algorithm in reduction of frequency estimate error is verified through simulations on noise, harmonics and frequency deviation.

Application of Supervisory System in Extra High Voltage Cable (초고압 케이블의 송전 감시 시스템 소개 및 기술동향)

  • Kwon, Byung-Il;Nam, Jeong-Se;Kang, Deok-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 1997.07e
    • /
    • pp.1791-1793
    • /
    • 1997
  • Since Korea was initiated a industrialization, many transmission lines have been installed to meet the increasing demand for the electric power. In large city, underground transmission lines were widely installed because of the environmental issue. But there have been appeared many failures on the lines, such as the external scar of cable, a fire in the culvert, overheating of cable, and so on. There have been many studies to monitor them and improve the reliability of the power supply. As a method monitoring the lines, a DTS(Distributed Temperature Sensor) system is developed and applied. This system monitors the lines and predicts the failures, using a optical fiber sensor. This paper describes this DTS system and its application for the underground transmission lines.

  • PDF

Study on Subway Emergency System Based on Wireless Sensor Network (무선 센서 네트워크 기반의 지하철 응급 상황 조치 시스템에 관한 연구)

  • Choi, Ho-Jin;Park, Jong-An;Pyun, Jae-Young
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.7 no.5
    • /
    • pp.139-146
    • /
    • 2008
  • Wireless sensor network-related application system can perform functions such as environmental pollution monitoring, building control, home automation in future. In this paper, we present wireless sensor network based system for subway station in order to reduce the damage of the people and the subway station due to fire. Sensor nodes in this system can sense temperature, illumination, smoke, and human body in real time and detect the accident in the subway station. These real-time sensing and wireless networking minimize casualties and damage to property.

  • PDF

Design and Implementation of U-city Infrared Image Surveillance System (U-city 적외선 영상 감시 시스템의 설계 및 구현)

  • Kim, Won-Ho;Jang, Bok-Kyu
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.10a
    • /
    • pp.561-564
    • /
    • 2009
  • This paper present design and implementation of U-city infrared image surveillance system based on the digital media processor. The hardware is designed and implemented by using commercial chips such as DM642 processor and video encoder, video decoder and the functions of software are to analyze temperature distribution of a monitoring image and to monitor disaster situation such as fire. The required functions and performances are confirmed by testing of the prototype and we verified practicality of the system.

  • PDF

Real-time measurement management system UI development linked the Water treatment facilities Broadband Convergence Network (수처리시설용 광대역 통합망 연계형 실시간 계측 관리 시스템 UI개발)

  • Yang, Seungyoun;Kim, Jintae;Oh, Hwanjin;Lee, Minwoo
    • Journal of Satellite, Information and Communications
    • /
    • v.10 no.4
    • /
    • pp.83-86
    • /
    • 2015
  • In this paper, we propose a real-tim measurement management system UI development linked the Water treatment facilities broadband Convergence Network. The sensor and the image data received by the server develop a program to interact with Web through water treatment facilities broadband convergence network. So, Separately develop UI capable of independently operating. Building a web server for remote monitoring of the transmission sensor and the image data. And Monitoring and control is possible the sensor data and image data through the Web-based UI. We can grasp the current state such as measurement time, concentration and depth of interface through the proposed real-time measurement management system UI development liked the water treatment facilities broadband convergence network. So, we can check in whether the normal operation of water treatment facilities and whether the casualties such as fire and security. As well as real time to see the information at a glance due to UI development can be raal-time monitoring of real-time measurement management system.