• Title/Summary/Keyword: Fire Hazard

Search Result 553, Processing Time 0.022 seconds

Survival Analysis of Forest Fire-Damaged Korean Red Pine (Pinus densiflora) using the Cox's Proportional Hazard Model (콕스 비례위험모형을 이용한 산불피해 소나무의 생존분석)

  • Jeong Hyeon Bae;Yu Gyeong Jung;Su Jung Ahn;Won Seok Kang;Young Geun Lee
    • Journal of Korean Society of Forest Science
    • /
    • v.113 no.2
    • /
    • pp.187-197
    • /
    • 2024
  • In this study, we aimed to identify the factors influencing post-fire mortality in Korean red pine (Pinus densiflora) using Cox's proportional hazards model and analyze the impact of these factors. We monitored the mortality rate of fire-damaged pine trees for seven years after a forest fire. Our survival analysis revealed that the risk of mortality increased with higher values of the delta normalized difference vegetation index (dNDVI), delat normalized burn ratio (dNBR), bark scorch index (BSI), bark scorch height (BSH) and slope. Conversely, the risk of mortality decreased with higher elevation, greater diameter at breast height (DBH), and higher value of delta moisture stress index (dMSI) (p < 0.01). Verification of the proportional hazards assumption for each variable showed that all factors, except slope aspect, were suitable for the model and significantly influenced fire occurrence. Among the variables, BSI caused the greatest change in the survival curves (p < 0.0001). The environmental change factors determined through remote sensing also significantly influenced the survival rates (p < 0.0001). These results will be useful in establishing restoration plans considering the potential mortality risk of Korean red pine after a forest fire.

Analysis of Characteristics of Electrical Arc Spark Detector (전기화재 아크.스파크검출기 특성평가에 관한 연구)

  • 정용기;신효섭;지철근;김영수
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.375-378
    • /
    • 2002
  • An arc/spark detector (ASD) was developed is to early detect wire failures and insecure connections that may lead to fire in residents and commercial and industrial facilities. A detailed circuit design for ASD implementation along with prototype product is reported. The tests of ASD, which were successful in phase identification, in many different arc/spark locations under different loadings, and in false alarm probability, showed the ability and capability of the state-of-the-art detector in the electric fire hazard prevention.

  • PDF

Ignition Hazard of Flammable Atmospheres by Optical Radiation (광 방사로부터 점화 위험성)

  • Choe, Sang-Won
    • Journal of Korean Institute of Fire Investigation
    • /
    • v.5 no.1
    • /
    • pp.25-28
    • /
    • 2004
  • Since the very first use of optical systems in the process industries there has been a tacit assumption that, because they are not electrical, they do not present an ignition risk when used in flammable atmospheres. This paper describes about an optical ignition mechanism from experimental work carnied out by Sira Safety Services Limited(UK) and whether there is sufficient of an ignition risk for precautions to be advisable when optical systems are used in flammable atmospheres.

  • PDF

Electric Fire Hazard in Low Voltage Distribution Circuits Protected by Electric Leakage Circuit Breaker(ELB) (누전차단기로 보호되는 저압선로에서의 발화위험성)

  • 홍성호;김두현
    • Journal of the Korean Society of Safety
    • /
    • v.15 no.1
    • /
    • pp.93-99
    • /
    • 2000
  • This paper presents a study on the assessment of electrical fire hazards by electric circuits with leakage. The hazards are evaluated with the energy supplied by earth-leakage currents which flow in the circuits simulating the actual circuit of domestic premises. Also, operating time and current of ELB are measured by an experimental approach. A common specification of ELB used in this paper has a sensitivity of 30[mA] for leakage current working on the current-balance principle. Total charges and energy of leakage currents are calculated quantitatively by a theoretical approach and compared with the results obtained from experiments.

  • PDF

Planning Controls for Land Use Safety (토지이용의 위험성 제어계획 -사용 밀도에 따른 기준치 설정의 접근방법-)

  • 노삼규
    • Fire Science and Engineering
    • /
    • v.10 no.2
    • /
    • pp.20-27
    • /
    • 1996
  • This paper discussed the limit of existing safety controls where the use of land around hazardous industry. There is a gap between engineering evaluation of acceptable criteria for loss reduction and risk exposure to the areas of high risk outside plants from the aspects of risk perception. The paper performed how land use safety could be designed between the density of uses with the duration of risk exposure by type of land use. It concluded the needs of multi-dimensional presentation for an appropriate risk controls on existing and future land use safety.

  • PDF

Qualitative Hazard Analysis for LNG Gas Stations Using K-PSR Method (K-PSR을 이용한 LNG 충진소에 대한 정성적 위험성평가)

  • Ko, Jae-Wook;Lee, Jae-Min;Yoo, Jin-Hwan
    • Journal of the Korean Institute of Gas
    • /
    • v.10 no.4 s.33
    • /
    • pp.63-69
    • /
    • 2006
  • With the increased interest in reducing air pollution, supply of natural gas for gas vehicles is increasing. Thus, the number of establishments of LNG and CNG stations is increasing as well. However, due to major gas accidents such as the fire and explosion accident of a Bucheon LPG station in 1998, it is difficult to establish a new station. In this research, we conducted qualitative hazard analysis fer LCNG/LNG multi-station by using the K-PSR method and proposed recommendations for hazard mitigation.

  • PDF

The Evaluation of Fire Safety Performance on Interior Finish Materials (Gypsum Board, Plywood) (건물내장재(석고보드, 합판)의 화재성능평가)

  • 김충환;김종훈;김운형;하동명;이수경
    • Fire Science and Engineering
    • /
    • v.15 no.3
    • /
    • pp.55-62
    • /
    • 2001
  • The fire performance evaluation methods in Korea and overseas for interior finish materials were analysed and tested with gypsum board and Plywood by using room corner test not adopted by domestic code until now. The results of gypsum board (thickness:8 mm) and Plywood (thickness:4 mm) applying NFPA 265 and ISO 9705 test respectively are satisfied the assessment criteria. To assess a actual fire performance and classify fire hazard levels for interior finish materials, room-corner test and flame spread models should be adopted in building code and fire code to overcome limitations of current bench-scale test method.

  • PDF

Numerical study of the Effect of Ventilation Condition on Rolling Stock Fire Growth through the FDS Simulation (환기량 조건이 열차 화재 성장에 미치는 영향성에 대한 FDS 화재 시뮬레이션)

  • Yang, Sungl-Jin;Lee, Chang-Deok;Oh, Ji-Eun;Kang, Chan-Yong
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.124-132
    • /
    • 2010
  • To predict and analyze the rolling stock's fire growth is considered not only important factor in estimating hazard analysis of rolling stock, but also a primary factor in aspect of a rail load facility. Because it's could be regarded as a ignition source in risk assesment for the facility i.e. tunnel and station. However, currently, standardized method to predict and analyze the fire growth has not been completed yet. it is due to the fact that fire growth is not only depended on thermal property of interior materials, but also is affected dominantly by various factors such as ignition source (characterized by location, duration, and intensity), train running condition and in/exterior ventilation condition. Especially, ventilation condition is one of the most effective factor to affect fire growth in compartment space as noticed by under-ventilation fire condition. In this study, the effect of each ventilation condition on fire growth and load were examined through the numerical method through FDS (Fire Dynamics Simulator).

  • PDF

A Study on Characteristics of Fire Temperature and Concentration of Toxic Gases while the Door Opening or Closed on Multi-layered Construction (복층건물의 출입문 개방여부에 따른 화재온도분포 및 독성가스 농도 변화특성에 관한 연구)

  • Lee, Jungyun;Kim, Jeonghun;Kim, Eungsik;Kim, Hong
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.2
    • /
    • pp.72-77
    • /
    • 2017
  • In S. Korea, recently, building fire accidents of residential accommodations or recreational facilities have taken place more frequently than before. Among various building constructions, Multi-layered structure, such as office-residential complex, are mostly made in S. korea. $O_2$, $CO_2$, CO, $NO_x$, $SO_x$, and HCl, these gases has toxic hazard and harmful for human body. And it is predicted that different concentration of released gases from diesel pool fire with upper and lower layer. Therefore, this study reports the fire characteristics of Multi-layered structure by analyzing the fire behavior and concentration of combustion gases of a experimental compartment via real scale fire experiment, in order to predict risks and secure safety for similar fire accidents.