The Evaluation of Fire Safety Performance on Interior Finish Materials (Gypsum Board, Plywood)

건물내장재(석고보드, 합판)의 화재성능평가

  • 김충환 (경민대학 소방안전관리과) ;
  • 김종훈 (경민대학 소방안전관리과) ;
  • 김운형 (경민대학 소방안전관리과) ;
  • 하동명 (세명대학교 산업안전공학과) ;
  • 이수경 (서울산업대학교 안전공학과)
  • Published : 2001.09.01

Abstract

The fire performance evaluation methods in Korea and overseas for interior finish materials were analysed and tested with gypsum board and Plywood by using room corner test not adopted by domestic code until now. The results of gypsum board (thickness:8 mm) and Plywood (thickness:4 mm) applying NFPA 265 and ISO 9705 test respectively are satisfied the assessment criteria. To assess a actual fire performance and classify fire hazard levels for interior finish materials, room-corner test and flame spread models should be adopted in building code and fire code to overcome limitations of current bench-scale test method.

본 연구는 국내와 외국의 건물 내장재 화재성능평가방법을 고찰하고 국내에는 도입되지 않은 실대 화재실험인 Room Corner Test를 국내 내장재중 석고보드와 합판을 대상으로 그 적용성을 위한 실험을 진행하였다. 현재 국내 내장재의 평가규정은 Bench-Scale Test에 의존하고 있으나, 미국, 일본 유럽등에서는 Room Corner Test를 적용한 실질적인 재료의 화재성능평가를 시행하고 있다. 실험 결과, NFPA 265에 의한 석고보드 및 ISO 9705에 의한 합판의 성능은 양호한 것으로 판단되었다. 현재 국내 내장재에 적용되는 등급분류의 평가방법은 재료의 실제 화재성능 평가에 한계가 있으므로 향후 Room Corner Test의 적용과 더불어 Bench-Scale Test 결과를 토대로 화재성능을 예측하는 화재모델을 이용하는 평가 방법의 도입이 필요하다.

Keywords