• Title/Summary/Keyword: Fire Hazard

Search Result 553, Processing Time 0.032 seconds

A Study on the Fire Safety Design Methods of Opening in High-rise Building (초고층고층 건축물의 개구부에 대한 화재안전 설계방법 조사)

  • Kwon, Young-Jin;Jin, Seung-Hyeon;Lee, Byeong-Heun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.8-9
    • /
    • 2018
  • In recent years, the fire risk in the aged housing facilities in high-rise building has been closing up due to the fire in the Grenfell Tower. In the case of these high-rise residential facilities, fire cases of residential facilities such as Uijeongbu Apartment Fire The fire hazard has been reexamined mainly. Especially, the fire of these residential facilities is very closely related to the window, so measures are needed. On the other hand, in Korea, there is almost no fire safety measures against these openings. Therefore, this study suggests improvement measures by comparison with advanced countries based on fire safety measures for domestic windows.

  • PDF

Study on building room fire development stages (건축물 실내화재의 단계에 대한 연구)

  • Cha, Jong-Ho
    • 한국방재학회:학술대회논문집
    • /
    • 2008.02a
    • /
    • pp.169-172
    • /
    • 2008
  • The purpose of this paper is to summarize characteristics of fire growth stages, combustion proceeding, human behavior factors against fire, fire active protections, fire alarms in order to perform public safety and protection, personnel property protection, with identification of economic analysis aspects based on respective stages classified as fire generation- fire growth- flashover- fire extinction, which is differ from previous studies that based on distinct concepts such as fire stages, escapes, building construction, fire sensing.

  • PDF

A study on Fire Hazard of Electric Radiant Heating Systems with Thermal Storage Using Off-peak Electricity (심야용 축열식 전기온풍기의 화재 위험성에 관한 연구)

  • Park, Min-Yeong;Mun, Yong-Su
    • Journal of Korean Institute of Fire Investigation
    • /
    • v.8 no.1
    • /
    • pp.41-48
    • /
    • 2006
  • The purpose of this study is to identify the fire danger of the electric radiant heating system and check the way how to use it and the problems that could be possible through a actual case. We carry out an experiment to identify the possibility of the fire in the similar condition of the actual fire case. The results of this study are as follows. It is a possible condition to fire if the air blast of the electric radiant heating system is blocked by some combustible materials such as plastic bags continuously. A temperature sensor and a residual current device are necessary to disconnect the power source. It is also necessary to attach a notice in front of the electric radiant hearing system that shows users the fire danger to forbid the possible fire. Fires could be happened by internal defects of the electronic products. However, we can also find many external reasons to happen fires. Therefore, we need to check all reasons to make fires in the scene of a fire.

  • PDF

Fire Risk Assessment of Temple Components in Young-dong Areas using Fire Loads (영동지역 사찰의 구성요소별 화재하중을 통한 화재위험성 평가)

  • Lee, Hae-Pyeong;Kim, Su-Young
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.10 no.3
    • /
    • pp.71-75
    • /
    • 2010
  • In this study, we have assessed the fire risk of Buddhist temples located in Youngdong area by means of fire loads of components. First, we categorized the components into Buddhist temples (Dae-Ung-Jeon, Pal-Sang-Jeon), Sam-Seong-Gak (Chil-Seong-Gak, San-Sin-Gak), a Buddhist temple dormitory (Sim-Geom-Dang, Seol-Seon-Dang), Lu, Il-Ju-Mun and then carried out a field survey. Then, we examined the area of each room, types as well as quantity and dimension of combustibles. The fire loads calculated in this way were 446.96 $kg/m^2$ for Buddhist temples, 331.71 $kg/m^2$ for Sam-Seong-Gak, 164.14 $kg/m^2$ for the Buddhist temple dormitory, 463.91 $kg/m^2$ for Lu and 1042.14 $kg/m^2$ for Il-Ju-Mun, thus showing Il-Ju-Mun with the biggest fire load. We speculate that this is because construction materials were similar in size and quantity to others albeit the area of Il-Ju-Mun is smallest.

The Study for the Optimal Location of Fire Stations in Seoul (서울시의 소방서 최적입지에 관한 연구)

  • Kim, Geun-Young;Kang, Sung-Il
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.2 no.1 s.4
    • /
    • pp.153-159
    • /
    • 2002
  • Disasters are the phenomena that we have to prevent the occurrence in order to keep the safety to human lives and properties, and if occurred, we have to minimize the economic, social, and mental costs of the occurred disasters or incidents. This research analyzes the optimal location of fire stations in terms of served population maximization in Seoul. This research introduces "the maximal covering location problem(MCLP)," one of the optimization techniques, as the primary research method. This research also applies a geographic information system into spatial distribution analyses of existing fire stations and observed fire incidents. Results from the analyses show that the existing location of fire stations and branches need to be improved. The dispatch location of fire engines should be reconsidered for rapid services of fire fighting.

Experimental Study on the Fire Resistance of Concrete Filled Steel Tubes according to Concrete Compressive Strengths (콘크리트 압축강도에 따른 강관기둥부재의 내화성능에 관한 실험적 연구)

  • Kwon, In-Kyu
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.11 no.2
    • /
    • pp.1-8
    • /
    • 2011
  • Concrete filled steel tubes(CFST) is considered as a column having better structural stability and better performance of fire resistance than that made with H-section and hollow section in itself. To get the fire resistance of the CFST, two kinds of concrete strength were used, 21 MPa, 40 MPa and 4 sorts of the applied loads were calculated and used to the specimens such as 3.5 m long, round and rectangular section. After various fire tests under 4 sorts of load ratios, the fire resistance of the CFST is not possible to get over 1 hour because of the rapid decrease of concrete strength. The below 50% of the applied load is recommended to obtain over 1 hour fire resistance of the CFST.

An Investigation of Hazard Distance in a Series of Hydrogen Jet Fire with the Hyram Tools (수소 누출 시 제트화재 피해 범위에 대한 분석)

  • KANG, BYOUNG WOO;LEE, TAECK HONG
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.28 no.2
    • /
    • pp.166-173
    • /
    • 2017
  • For commercialization of hydrogen refuelling station (HRS), we need to reduce the clearance distance for jet fire in the real entities in the HRS. Thus, we revisited the current regulations of clearance distance for jet fire in the law. The law in korea has been set up by replica of japan, not by our own scientific basis. Recently, sandia lab developed Hydrogen Risk Assessment Model (HyRAM) tools and we simulated a series of circumstances such as 10 to 850 bar with several leak hole sizes. In 850 bar with 10 mm diameter hole leak cases, it shows $4,981kW/m^2$ at 12 m separation from leak source and $1,774kW/m^2$ at 17 m separation from leak source. In 850 bar with 1 mm diameter leak hole, it shows $0.102kW/m^2$ at 12 m separation and $0.044kW/m^2$ at 17 m separation. Current law may be acceptable with 1 mm hole size with 850 bar.

A Study on the Design of Evacuation Route at Subway Station Using Simulation Analysis (Simulation 분석을 통한 지하철 역사 피난동선 설계 방안에 관한 연구)

  • Ham, Eun-Gu;Roh, Sam-Kew
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.10 no.5
    • /
    • pp.1-7
    • /
    • 2010
  • Since subway fire disaster at Daegu, Korea smoke control system and passengers evacuation distance has been focused to reform. Existing smoke control facilities need to expand volume of ventilation capacity however, the complicate subway station structure can hardly react dispersion of smokes from massive subway cabin fire. Smoke flow at platform level move upward thought vertical stairway and passengers evacuation goes with same direction. The victims of evacuees from subway station fire mainly due to exposure of heat radiation and smoke. The study demonstration the effect of downward evacuates stairway system by separating evacuation route to smoke movement pass way including saving times of evacuation.

The Hazard of Ignition on the Bimetal Type Thermostat Molded by Phenol Resin (페놀수지로 몰딩된 바이메탈식 서모스탯의 발화위험성)

  • Park, Y.G.;Lee, S.H.
    • Journal of Korean Institute of Fire Investigation
    • /
    • v.11 no.1
    • /
    • pp.63-73
    • /
    • 2007
  • In this paper, we discussed the hazard of ignition on the bimetal type thermostat molded by phenol resin with case study and accelerated aging test. We experimented three type thermostats molded by phenol resin which are used on hot/cold water dispenser. On the case study, the thermostat was origin of 6re and dry tracking occurred around it's moveable contactor. On the accelerated aging test, the more thermostat was switched, the more damaged it become. One of the A-type thermostats that is similar type on the case study fired around moveable contactor. We therefore confirmed that the tracking around the moveable contactor of bimetal type thermostat molded by phenol resin could be origin of fire and it is available to reduce of fire that using noncombustible material for molding of bimetal type thermostat.

  • PDF