• Title/Summary/Keyword: Fire Fighting Law

Search Result 44, Processing Time 0.024 seconds

A Study to Prevent the Fire in Residential Buildings (주거용 건축물의 화재 예방에 관한 고찰)

  • Park, Kyong-Jin;Kim, Hye-ree;Lee, Bong-Woo;Park, Shin-young
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.23 no.2_2
    • /
    • pp.307-312
    • /
    • 2020
  • This study presents problems and improvement measures for the supply rate of single-alarm detector and fire extinguisher installed in households. Statistics from the NFDS show that 18 percent of all fires and 45 percent of deaths occurred in residential buildings over the past eight years. It was less than 60% that households be equipped rate of basic fire-fighting systems by 2019. In this study, I analyzed the law and statistics of fire to devise a method for fire safety. I proposed that the basic fire-fighting systems is be equipped in households. Like this : First, a free distribution policy for the over 60 years of age and Areas where is fire engine difficult to enter. Second, the policy of adopting safety pay in disaster. Third, the policy of expanding supply through the revision of the Licensed Real Estate Agents Act. Fourth, the policy of self-regulating installation by safety education and set up a data base system. Fifth make a law of household's National Fire Safety Standards.

The Special Plan of the Traffic Accident Treatment in the Emergency Car Concerning Fire Fighting (소방관련 긴급자동차의 교통사고처리 특례방안)

  • Jeng, Gi-Sung
    • Fire Science and Engineering
    • /
    • v.22 no.2
    • /
    • pp.20-29
    • /
    • 2008
  • The traffic accident of Fire engine takes place very much, compared with that of the past. The reason is that there is a lot of the increase of the demand in the fire, rescue, first aid, and the public request. Also, because the Fire engine should go out at the place of the accident very quickly, it should inevitably violate the traffic regulations. Therefore, this is due to the traffic accident. Despite the urgent situation in the infringement motive of traffic regulations, the outbreak of the traffic accident does not vary largely from the degree of the disadvantage. Accordingly, a fire officer should take charge of his social and economic disadvantage by himself. In this situation, a fire officer has no choice but to start moving passively not to be afflicted with his own disadvantage. Most of the situations concerning the fire fighting are the ones to be controlled urgently. Nevertheless, because of the disadvantage of the traffic accident, passive mobilization of the fire fighting equipment is the heavy burden of all the people of the nation. Therefore, Special institutional safety device should be ready for the protection of the life and property of all people. The special law concerning the processing in the accident of the emergency car needs to be revised. By establishing this special law, the government should not provide the officer who drives the fire engine with the disadvantage caused by traffic accident.

A Study on Development of Assessment Criteria for Safety City of Fire Fighting Area (소방방재분야의 안전도시 평가기준 개발에 관한 연구)

  • Choi, Kyu-Chool
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2009.04a
    • /
    • pp.218-228
    • /
    • 2009
  • The basic law about disaster and safety management and the fire fighting law state that the central government and the local governments are responsible for protecting the life and assets of the people. The well-fare developed nations have developed and are implementing diverse safety programs with making safe cities as their prime objective. Our nation has not yet practiced such actions. However, it is in demand to evaluate what safety policies are practiced by local governments for the people and to inform the people of those. Therefore, this research developed and suggests the assessment criteria and the assessment method to evaluate the safety level of a city by assessing the safety of buildings and facilities.

  • PDF

The Study About the Installation of Fire-fighting Office by the Local Government (기초지방자치단체의 소방기관설치에 관한 연구)

  • 전경배
    • Fire Science and Engineering
    • /
    • v.17 no.3
    • /
    • pp.31-44
    • /
    • 2003
  • In the Local Autonomy Law, we regard the fire-fighting service as inherent service for the local government. However, if we look into the course of the charge of fire-fighting service, after the transfer of this from the police service, or the state, to the local service in 1991, this is now taking a firm hold as service of the local government. what we call the local services includes the business about the welfare of the residents and that of taking in charge of the resident properties, proclaimed in the Constitution. That is to say, the basic purpose of the local autonomy is to make the residents feel the most convenient and safe, and this is the mission of the present-day local autonomy. Looking from this point of view, if we consider that the ultimate purpose of fire-fighting is promoting the welfare of the residents by preventing and putting out fires and, in the time of emergency, carrying out rescue and relief operations, and furthermore, maintaining the safety and order of a society, until present time the benefits of fire-fighting business were mainly available to the residents of the cities. In order to break from these thoughts, according to the result of comparing and analyzing the metropolitan city, surrounding rural areas, middle and small cities and typical rural areas, the rural areas are urgently demanding fire-fighting service, so it is being proved that it is necessary to install the offices in these areas. Therefore, the installation of the fire-fighting offices in the counties that are the basic units of the primary local autonomy and are rural areas should be expanded as part of the welfare administration.

A Study on the Application of Simple Sprinkler Facility at Single Housing (단독주택의 간이스프링클러설비 적용에 관한 연구)

  • Hong, Sung-Woo;Lee, Young-Jae
    • Fire Science and Engineering
    • /
    • v.22 no.4
    • /
    • pp.33-41
    • /
    • 2008
  • Presently, there is no legal regulation pertaining to the installation, maintenance, management and operation of fire-fighting facilities in single housing in Korea, relying instead on the awareness of the residents which hopefully will prevent fire. Likewise, accident prevention effort is very limiting and weak. Accordingly, this research examines current situation in which fire results, identifies root causes and studies application of regulations and develop design measures centered on the single housing that is most afflicted with fire. As part of the measure to prevent fire that afflict housing, it is necessary to classify single housing as specific target for fire fighting just like the joint housing among the types of the building structures that are classified according to the usage on the "Appendix Chart I of the Enforcement Ordinance of the Construction Law" for management purpose. Moreover, it is necessary to make the installation of fire-fighting facilities such as simple sprinkler facility for residential area, fire extinguisher, warning system and others for the sake of the senior citizens and disabled people who reside in single housing, mandatory.

A study Fire Protection and Evacuation System for Buildings (건축물의 방화 및 피난계획에 관한 연구)

  • 이경수;임만택
    • Fire Science and Engineering
    • /
    • v.2 no.2
    • /
    • pp.9-16
    • /
    • 1988
  • This study is intended to suggest some ideal measures available in the course of construction from the viewpoint of an architect to reduce damage of human lives and Properties caused by fire accidents in buildings. For this study, 7 buildings burnt by conflaguration in Seoul during the years of 1985 and 1987 are picked up, and 105 withnesses, who were present in one of them at them at fire, are traced for personal interview and respones to the written questionaire about 5 main issues; their perceptional behaviour, their emotional state at that time, their reactions to avoid danger, their escape routes, and their usual awareness to prevent fire. Some desirable measures suggested here are ;making Provisions to install fire centers in large buildings and underground structures in the fire fighting law, and requlating to compose fire units appropriate to the quantity of combustibles inside, limit the length of a blind corridor, furnish balustrade, and limit the width of the landing of the stairs in building code and regulations. Such measures should be considered from the time of planning to construct a building, and some drill and education in fire prevention is demanded for the occupants of the buildings too.

  • PDF

A Study on the Administration System for Disaster Relief in Korea (한국 재난관리체계의 문제점과 개선방향)

  • Kang, Byung-Woo
    • The Korean Journal of Emergency Medical Services
    • /
    • v.5 no.1
    • /
    • pp.133-145
    • /
    • 2001
  • The scale of disasters is very large, also the influence of disasters is irreversible. Korean people has continuously learned how to deal with disaster management law. However, as time goes by after the many disaster, the concern with the disaster management by the people seems to become old and banal topic which nobody has interest in. If so, can it be said that our society is safe from the disaster? This study start from critical mind of asking this question. This study puts an emphasis on the problems such as following; To realize whole concept of disaster management provided in the basic civil defense law, the combined disaster management should be required to be established, the combined law should play a integral part for prevention for the disaster and should be a concrete basis of various laws for disaster management. Establishing a consolidated organization for disaster managing and united response organization is necessary. This consolidated organization is not temporary one such as civil disaster control headquarter but permanent one such as Disaster Management Office which controls an over all aspects of disaster management. Temporary organization should not be divided into natural calamity and man-made calamity but integrated one as a single control tower for all sorts of disasters. The police and army under fire fighting system should be reconsidered. It is necessary to make leadership system on the disaster place more substantial centered around present fire fighting system. To do so, more clear division of duty is required. The working condition should be improved so that all public servants in this agency can play their roles with pride and worth. The resource owned the existing administrative organization must be used by an appointment system. And to manage a large scale of disaster, it is necessary to have interorganizational network system which many specialized organization including volunteer group are integrated. And the natural disaster happen, many professionals and volunteers are distributed to the spots of disaster in the right man in the right place. Finally, citizen's consciousness about safety supervision needs to be recover.

  • PDF

A Study about False Alarm of Automatic Fire Detection System (자동화재 탐지설비의 비화재보 감소방안)

  • Lee, Jong-Hwa;Lee, Chun-Ha;Kim, Shi-Kuk;Kong, Ha-Sung
    • Journal of the Korea Safety Management & Science
    • /
    • v.13 no.1
    • /
    • pp.41-49
    • /
    • 2011
  • The automatic fire detection system is an important facility installed with focusing on minimizing the damage from a fire. This paper presents in the followings as the methods to reduce the false alarm of the automatic fire detection system; first, to prepare for legal standard so that revised legal standard can be applied to the fire fighting property prior to revision; second, to introduce the performance based fire detection protection design in the law based fire protection design; third, to maintain the wiring of worn-out detector; forth, to introduce an evaluation system to the education for the fire warden; fifth, to extend the standard of MTBF(meantime between failure) of the detector; sixth, to extend of installing the analog type detector; seventh, to improve the structure of reset switch.

A Study on the Improvement Method of the Fire Department Connection for Fire Fighting at the Shopping Center Building (상가건물 소방용 연결송수관설비 송수구의 개선방안에 관한 연구)

  • Lee, Young-Sam
    • Journal of the Korea Safety Management & Science
    • /
    • v.18 no.4
    • /
    • pp.11-17
    • /
    • 2016
  • Currently, the number of a shopping center building is increasing because most people want to go a shopping center building easily for buying many things and eating some foods. That are a normal trend these days. However, the increasing number of shopping center buildings has been increasing the number of shopping center building fires which also have been making social problems. Therefore, this study was conducted for the fire department connection among other fire facilities because it is important for fire suppression. The research subject is on the fire department connections that are on 70 shopping center buildings of more than 5 years old constructed. Survey and analysis were conducted for 70 fire department connections. The result of this study is that all installed fire department connections have a type that includes one or two holes each at 65mm wide, and the average distance between fire department connections and access roads is 4.85m. The total average percentage of insufficiency conditions such as drive ways for fire trucks, visibility, accessibility, pressure range sign, installed height, cover of the hole, etc. is 45.3%. So improvement of law and systems, that are fire facility construction and maintenance implementations, will be needed in my opinion.

A Study on Fire Hazard Analysis and Smoke Flowing for the Semiconductor Manufacturing Process (반도체 제조공정의 연기유동에 관한 연구)

  • Han, Soo-Jin;Kang, Kyung-Sik
    • Journal of the Korea Safety Management & Science
    • /
    • v.9 no.1
    • /
    • pp.197-211
    • /
    • 2007
  • The power of semiconductor, Korea is continuously constructing semiconductor production line for keeping a front-runner status. however, studies and data about potential risks in semiconductor factory are still short. If fire does not initially suppressed, the fire causes a great damage. To decrease fire risk factors, in addition to fire fighting safety equipment, more important thing is how to design and construct fire protection system. The current fire protection codes about semiconductor factory come under functional law, and this law is short of consideration about particularity of factory. The existing prescriptive fire codes depending on experience compose without evident engineering verifications, thus equipments which is created by the current prescriptive fire code may bring about a variety of problems. For example, the design under the current regulation can not cope with the excessive investments, low efficiencies, and the diversifying construction designs and be applied to the quick changes of new technologies. Ergo, an optimal design for fire protection is to equip fire protection arrangements with condition and environment of production field. Manufacturing factory of semiconductors is a windowless airtight space. And for cleanliness, there exists strong flow of cooperation. Therefore, there is a need for fire safety design that meets the characteristic of a clean room. Accordingly, we are to derive smoke flow according to cooperation process within a clean room and construction plan of an optimal sensor system. In this study, in order to confirm the performance of proposed smoke-exhaust equipment and suggest efficient smoke exhaust device when there is a fire of 1MW of methane in the clean room of company H, we have implemented fire simulation using fluid dynamics computation.