• 제목/요약/키워드: Fire Event

검색결과 339건 처리시간 0.022초

Assessment of Post-Earthquake Fire Behavior of a Steel MRF Building in a Low Seismic Region

  • Chicchi, Rachel;Varma, Amit
    • 국제강구조저널
    • /
    • 제18권4호
    • /
    • pp.1470-1481
    • /
    • 2018
  • Building-level response to post-earthquake fire hazards in steel buildings has been assessed using primarily two-dimensional analyses of the lateral force resisting system. This approach may not adequately consider potential vulnerabilities in the gravity framing system. For this reason, three-dimensional (3D) finite element models of a 10-story case study building with perimeter moment resisting frames were developed to analyze post-earthquake fire events and better understand building response. Earthquakes are simulated using ground motion time histories, while Eurocode parametric time-temperature curves are used to represent compartment fires. Incremental dynamic analysis and incremental fire analysis procedures capture a range of hazard intensities. Findings show that the structural response due to earthquake and fire hazards are somewhat decoupled from one another. Regardless of the level of plastic hinging present in the moment framing system due to a seismic event, gravity column failure is the initiating failure mode in a fire event.

거실 제연설비 성능 개선을 위한 국내·외 기준 비교 분석에 관한 연구 (A Comparative Analysis of Domestic and Foreign Standards to Improve the Performance of Zone Smoke Control System)

  • 허예림;김윤성;김혜원;진승현;권영진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2022년도 봄 학술논문 발표대회
    • /
    • pp.83-84
    • /
    • 2022
  • In Korea, smoke control measures through NFSC 501 are proposed to reduce human casualties caused by smoke in the event of a fire. However, as a result of investigating and analyzing domestic and foreign standards, it was found that domestic regulations do not set fire source, but simply set smoke emissions by floor area or height of smoke boundary. Foreign regulations set fire source. Therefore, it is judged that it is necessary to review whether the current domestic regulations can be applied in the event of an actual building fire. So, this paper aims to identify the differences in domestic and foreign standards through investigation and analysis of related standards for fire zone smoke control system in each country and use them as basic data to improve the performance of zone smoke control system.

  • PDF

주유소 내 부대시설 화재발생시 복사열에 따른 주유설비 안전거리에 관한 연구 (A Study on the Safety Distance of the Fuelling Facilities by the Radiation Heat in the Fire at the Gas Station)

  • 김기성;이상원;송동우
    • 한국가스학회지
    • /
    • 제25권6호
    • /
    • pp.7-13
    • /
    • 2021
  • 최근 주유취급소 내의 건축물에 편의점, 자동차 수리점 등의 부대시설이 증가하고 있다. 이에 따라 부대시설에서 화재 발생 시 고정주유기에 미치는 화재의 영향을 알아보고 현행 규정의 타당성을 검증할 필요성이 있다. 본 논문에서는 부대시설에서의 화재 시 고정주유기까지의 이격거리에 따라 미치는 복사열의 영향을 알아보는 연구를 진행하였다. FDS 5.5.3을 사용하여 화재모델링을 하였고, 화원의 크기는 실규모 화재평가 장치를 이용한 사무실의 연소실험을 통한 단위면적당 열방출율을 입력하였다. 화원과 고정주유기의 이격 거리는 '위험물안전관리법 시행규칙 별표13 주유취급소의 위치·구조 및 설비의 기준'에서 명시하는 2 m 부터 이격거리를 1 m 간격으로 늘여가며 10 m까지 화원의 크기를 Case A의 경우 512.41 kW/m2, Case B의 경우 250 kW/m2로 설정하여 총 13개의 시나리오를 구성하여 연구를 진행하였다. 시뮬레이션을 통해 2 m의 이격거리는 부대시설의 화재 시에 주유기의 안전성을 확보하지 못하는 것으로 나타났으며 최소 4m 이상의 이격거리에서 복사열이 피해를 미치지 않는 것으로 나타났다. 이에 따라 부대시설의 화재 발생시 복사열을 차단할 수 있는 설비가 필요하며 부대시설의 용도를 제한하거나 건축물과 고정주유기의 이격거리를 다시 제고하는 방안이 필요할 것이다.

Overview of the Benefits of Structural Fire Engineering

  • Jowsey, Allan;Scott, Peter;Torero, Jose
    • 국제초고층학회논문집
    • /
    • 제2권2호
    • /
    • pp.131-139
    • /
    • 2013
  • The field of structural fire engineering has evolved within the construction industry, driven largely by the acceptance of performance-based or goal-based design. This evolution has brought two disciplines very close together - that of structural engineering and fire engineering. This paper presents an overview of structural systems that are frequently adopted in tall building design; typical beams and columns, concrete filled steel tube columns and long span beams with web openings. It is shown that these structural members require a structural analysis in relation to their temperature evolution and failure modes to determine adequate thermal protection for a given fire resistance period. When this is accounted for, a more explicit understanding of the behaviour of the structure and significant cost savings can be achieved. This paper demonstrates the importance of structural fire assessments in the context of tall building design. It is shown that structural engineers are more than capable of assessing structural capacity in the event of fire using published methodologies. Rather than assumed performance, this approach can result in a safe and quantified design in the event of a fire.

원전 노출 화재시 케이블 기능상실 온도에 관한 연구 (A Study on Cable Functional Failure Temperature by Exposed Fire in Nuclear Power Plants)

  • 김두현;임혁순
    • 한국안전학회지
    • /
    • 제26권5호
    • /
    • pp.41-45
    • /
    • 2011
  • The fire event occurred in fire proof zone often causes serious electrical problems such as shorts, ground faults, or open circuits in nuclear power plants. These would be directed to the loss of safe shutdown capabilities performed by safety related systems and equipments The fire event can treat the basic design principle that safety systems should keep their functions with redundancy and independency. In case of a cable fire, operators can not perform their mission properly and can misjudge the situation because of spurious operation, wrong indication or instrument. These would deteriorate the plant capabilities of safety shutdown and make disastrous conditions. In this paper, the cables of the representative nuclear power plant in korea is selected and the cable functional failure temperature by exposed fire using Cable Response to Live Fire(CAROLFIRE) is studied. It is expected that the results are very useful to know the cable failure temperature by exposed fire. We confirmed the safety and integrity of the cable by exposed fire and those results will use the based data of cable exposed fire characteristics.

초기 화재 진압을 위한 자율주행 소방 로봇 시스템 설계 (Design of an Autonomous Firefighting Robot System for Early Fire Suppression)

  • 김효민;김정용;문성준;이아현;이창수
    • 로봇학회논문지
    • /
    • 제19권3호
    • /
    • pp.287-292
    • /
    • 2024
  • The initial suppression of fires is critical to protecting human and material resources. In response to this, fire prevention and suppression systems using artificial intelligence and robot technology have recently been studied. In particular, an autonomous driving system that detects a fire using CNN is attracting attention. These systems respond quickly in the event of a fire, enabling initial fire suppression. However, since the conventional system is not equipped with a fire suppression function, direct intervention of firefighters is required. (1) To overcome these limitations, we propose an autonomous fire detection robot system equipped with a fire suppression function ROS-based firefighting system called 'ADEFS' (Autonomous-Detect & Extinguish-Fire Service). (2) The system performs three tasks to detect and extinguish. Tasks are to run the Ros-based SLAM Navigation, YOLO-CNN, and Four-degree freedom manipulator connected to the fire extinguishing pump. (3) Through this, early response in the event of a fire can minimize damage to life and property and can reduce labor costs, which can also be expected to reduce costs for companies.

국내 원자력발전소의 화재사건 확률론적안전성평가에서 다중오동작 분석 연구 (A Study on the Multiple Spurious Operation Analysis in Fire Events Probabilistic Safety Assessment of Domestic Nuclear Power Plant)

  • 강대일;정용훈;최선영;황미정
    • 한국안전학회지
    • /
    • 제33권6호
    • /
    • pp.136-143
    • /
    • 2018
  • In this study, we conducted a pilot study on the multiple spurious operations (MSO) analysis in the fire probabilistic safety assessment (PSA) of domestic nuclear power plant (NPP) to identify the degree of influence of the operator actions used in the MSO mitigation strategies. The MSO scenario of the domestic reference NPP selected for this study is refueling water tank (RWT) drain down event. It could be caused by spurious operations of the containment spray system (CSS) of the reference NPP. The RWT drain down event can be stopped by the main control room (MCR) operator actions for stopping the operation of CSS pump or closing the CSS motor operated valve if the containment spray actuation signal (CSAS) is spuriously actuated. Outside the MCR, it can be stopped by operator actions for closing the CSS manual valves or motor operated valve or stopping the operation of CSS pump. The quantification result of a fire PSA model that takes into account all recovery actions for the RWT drain down event lead to risk reduction by about 95%, compared with quantification result of fire PSA model without considering them. Among the various operator actions, the recovery action for the spurious CSAS operations and the operator action for the manual valve are identified as the most important operator actions. This study quantitatively showed the extent to which the operator actions used as MSO countermeasures have affected the fire PSA quantification results. In addition, we can see the rank of importance among the operator recovery actions in quantitative terms.

CNG 버스 및 충전소의 화재 위험도 평가 (The Eire Risk Assessment in Compressed Natural Gas Buses & Gas Station)

  • 고재선;김효
    • 한국화재소방학회논문지
    • /
    • 제18권2호
    • /
    • pp.57-67
    • /
    • 2004
  • Diesel 버스가 대체적으로 주류를 이루는 일반버스들에 대한 위험도 평가결과 첫째, 순간적인 누출이 일어날 빈도는 1.4E-3/bus/year이었으며, 이로 인한 하부사상으로 Fireball의 결과를 초래할 확률은 1.7E-4이었다. 또한 그 중 CNG 버스에서 순간적인 누출이 일어날 수치는 0.002 event/year로 나타났다. 둘째, 균열에 기인되어 점차적인 누설이 일어날 빈도는 3.7E-s/year로 평가되었으며, 이에 대한 하부사상으로서 jet flame의 결과를 초래할 확률은 1.2E-3으로 나타났다. 또한 CNG 버스에서 점차적인 누출이 일어날 수치는 0.04 event/year이었다. 아울러 피해 예측 면에서 CNG버스와 디젤버스의 운송거리에 대해 화재 사상자들을 비교하였을 때, 디젤버스는 0.091 Fire fatalities/100-million miles이었으며, CNG버스는 대략 0.17 Fire fatalities/100-million miles이었다. 이 의미는 화재로 인한 치명적인 사상자수를 비교했을 때 CNG버스는 디젤버스에 비해 평균 두 배가 위험하다는 것을 보여 주는 것이고, 결국 CNG버스들이 디젤버스들에 비해 주요 화재에 대해 민감하다는 것을 말해 주는 것이다. 본 연구에서 CNG버스들의 위험도를 평가하기 위해 사용된 총칭적인 모델들과 고장 데이터들은 적정하다. 그러나 CNG버스와 관련된 연구에 있어서 더욱 더 정확한 결과를 제공하기 위해서는 향후 더 정확한 물리적인 면에 기초한 모델들과 CNG버스에 대한 자료 확충 및 데이터베이스화가 요구된다.

원자력 발전소에 있어서 방화의 최적화를 위한 확률론적 방법

  • 김화중
    • 한국화재소방학회논문지
    • /
    • 제8권2호
    • /
    • pp.58-63
    • /
    • 1994
  • 독일 원자력 발전소에서는 포괄적인 방화 연구의 한 부분으로써 방화에 관한 분석과 그것을 최적화 할 수 있는 확률론적 방법을 개발하였다. 그 일반적인 흐름을 살펴보면, 미국의 화재 위험성 분석의 방법을 따랐으며, 세밀한 부분에서는 약간의 수정을 한 것이다. 먼저, 선정된 공장지역에서의 화재 사건 경로(fire event tree)는 화재가 발생했을 때, 방화 조치와 안전시스템을 능 수동적으로 고려해서 설정된다. 방화 조치와 안전 시스템에 있어서의 실패 모델(failure model)은 발화 후 시간과 화재 영향과 같은 일상적인 변수와 관련해서 생긴다. 이러한 관련성은 일차(first-order) 시스템의 신뢰성 이론을 적절히 이용해서 화재 사건 경로를 분석할 때 알 수 있다. 더불어 화재가 발생했을 떠 방화 시스템의 실패 빈도, event paths의 상대적인 비중, 이러한 path내에서의 방화 조치 그리고 실패모델의 변수 등은 모두 시간 함수로 계산된다. 이러한 자료에 근거를 두고, 방화의 최적화는 주로 event path, 방화조치와 비중이 가장 큰 변수를 수정함으로써 가능하게 된다. 이것은 독일의 1300 MW PWR reference plant를 예를 들어서 증명될 것이다. 또한 충고를 받아들여서 수정을 하는 것은 발전소 직원과 화재 피해의 위험성을 줄일 수 있다는 것을 보여주고 있다.

  • PDF

Combustible Gas and Visible Distance by Sprinkler Head for Safety of Gymnasium Workers

  • Ahn, Jae-Cheon;Kong, Ha-Sung
    • International journal of advanced smart convergence
    • /
    • 제10권3호
    • /
    • pp.232-244
    • /
    • 2021
  • This study analyzed the changes in carbon monoxide, carbon dioxide, oxygen and visual distance by presence of sprinkler heads and their types in the event of a fire in an indoor gymnasium. Based on carbon monoxide and visual distance that affects human bodies enormously, first, if there is no sprinkler head, carbon monoxide will reach 0.4% within five seconds and visual distance rapidly shrank within five seconds. Seconds, in the event of standard sprinkler heads, carbon monoxide gradually increased from 30 seconds onwards and visual distance rapidly shrank after five seconds. Second, Third, if there are special sprinkler heads, carbon monoxide fluctuated after opening the head and visual distance became 5m or below from 15 seconds. Finally, in the event of early response sprinkler heads, carbon monoxide fluctuated up and down at 3 seconds due to falling water drops. Visual distance shrank up to 5m or below at 6 seconds. In the future, time for operation of each sprinkler head shall be analyzed.