• 제목/요약/키워드: Fire Door

검색결과 217건 처리시간 0.031초

방화문의 내화성능 향상을 위한 3단 문 결속기 연구개발 (Research and development of a three-stage door binder to improve the fire resistance of fire doors)

  • 임보혁;이주원;조동환;이해열
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2023년도 가을학술발표대회논문집
    • /
    • pp.157-158
    • /
    • 2023
  • Doors that are opened and closed when entering or exiting a general building are connected to the door frame and open and close. They are equipped with door locking devices of various structures, and are either locked to the door frame for the closing operation or released from the door frame for the opening and closing operation. Here, a single-stage door binding device having a door latch that is independently disposed at the center of one axis of the door is commonly used. On the other hand, if the size of the door is over a certain size or if the door is medium to large, the opening and closing operation may not be performed smoothly with only a single stage binder, or the closing state may not be achieved stably during the closing operation. In particular, in the case of the single-stage binding device provided in medium to large fire doors, the door is fixed to the door frame unstable, causing fatal errors in the fire prevention function of the fire door. Accordingly, in order to fundamentally solve these problems, we researched and developed a three-stage door binding machine that combines a top and bottom fastening structure with a single-stage fastening structure. This 3-stage door binder not only has the fire resistance performance of a fire door, but also has a T-shaped terminal in its fastening method, so if you eliminate the upper and lower fastening, it is a 1-stage binder like a regular product, but if you remove the door latch of the 1st-stage binder, it functions as an upper and lower 2-stage binder and forms a single mold. We researched and developed a three-stage door binder that can manufacture and produce three products at the same time, satisfying both product performance and price.

  • PDF

방화문의 현장품질관리 개선방안에 관한 연구 (A Study on Improvement of the Quality Management for Fire Doors)

  • 최동호
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2019년도 춘계 학술논문 발표대회
    • /
    • pp.93-94
    • /
    • 2019
  • When the fire door is recently installed in the field, there are frequent cases where the fire door is manufactured with fire door having low quality or different structure compared to the performance that the fire door producer has confirmed in the performance test or the construction specification. In order to improve the on-site quality management of the fire door, we comprehensively classify the quality management items of the fire door according to the management subject and the step by stage and set the field quality management procedure, the field quality management inspection item, regulations and standardized checklists were presented.

  • PDF

다중이용시설의 피난방화문에 관한 연구 (Study of evacuation fire doors in multiple facilities)

  • 차종호
    • 한국산학기술학회논문지
    • /
    • 제15권12호
    • /
    • pp.7380-7384
    • /
    • 2014
  • 피난방화문이란 기존에 성능을 인정받은 방화문의 전면에 축광도료를 바르고 손잡이 부근에는 시온도료를 발라 제작한 방화문으로 기존에 방화설비로만 사용되었던 방화문에 피난 및 안전 기능을 추가, 방화문 자체가 피난설비로서의 기능을 겸용하는 설비이다. 피난안전방화문의 휘도는 기존의 유도표지 휘도(60분후 7mcd)이상의 성능으로 한국소방산업기술원의 휘도시험을 통과한 설비로, 화재 시 가시성의 면적이 피난구유도등에 비해 크며 연기의 하강에도 방화문 아랫부분의 방광상태가 관찰되어 피난자들의 피난유효 시간을 연장시켜 줄 것으로 사료된다. 손잡이 부근에 발라져 있는 시온도료는 일정온도에 도달하면($70^{\circ}C$) 색상이 변화 위험경고가 방화문 바탕에 나타나게 되어 화재 시 피난자들이 방화문 손잡이에 입을 수 있는 1차 재해를 예방할 수 있으며, 화재공간에 진입을 하여야 하는 소방관들에게는 역화 가능성을 사전에 인지 안전 사고를 예방하는데 도움을 줄 것으로 판단된다.

방화문 시공시 현장품질관리지침 적용에 관한 연구 (A Study on the Application of Quality Management to Fire Door Construction)

  • 최동호
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2019년도 추계 학술논문 발표대회
    • /
    • pp.90-91
    • /
    • 2019
  • When the fire door is recently installed in the field, there are frequent cases where the fire door is manufactured with fire door having low quality or different structure compared to the performance that the fire door producer has confirmed in the performance test or the construction specification. Accordingly, on-site quality management and maintenance guideline for fire doors were presented. In this paper, we tried to explain the requirements for the construction of fire doors during the on-site quality management and maintenance guideline for fire doors presented in the study.

  • PDF

공동주택 세대 현관 방화문 구조에 관한 통계적 분석 (Statistical Analysis on the Structure of the Front Door in Apartment House)

  • 심한영;박원준
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2021년도 가을 학술논문 발표대회
    • /
    • pp.23-24
    • /
    • 2021
  • Since 2011, apartment houses account for about 41% of the fires in residential facilities for the past 10 years. Fire-resistant performance of fire doors is becoming more important to prevent the spread of fire in apartment houses. This research analyzed the structure of fire door through each 10 DB based on the quality inspection report of Continuous Acquisition & Life-cycle Support(CALS) from 2016 to 2020, which passed the fire performance test based on the laws and notices of domestic fire door. Therefore, based on the results of the analysis of DB in the future, we will conduct a study on structural improvement and addition for fireproof performance improvement of fire door.

  • PDF

공동주택 방화문의 내구성능 및 내용연수 제안에 관한 연구 (A Study on the Proposal of Durability and Service Life of Fire Door in apartment house)

  • 권영진;김윤성;진승현
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2022년도 가을 학술논문 발표대회
    • /
    • pp.49-50
    • /
    • 2022
  • There are continuous cases of fire expansion due to fire door problems around the world, including the 2010 Shanghai Apartment Fire, the 2017 Grenfell Tower Fire in England, and the 2020 Ul-san Residential and Commercial Complex Fire. In order to prevent such fire damage, the country has strengthened the performance standards of fire doors, and recently, efforts have been made to ensure the best performance of fire doors by introducing a quality recognition system. Securing the performance of fire doors is a very important aspect. However, there is a concern that old fire doors may not function normally in the event of fire due to natural deterioration, corrosion, and damage during the use process, but countermeasures are insufficient. Therefore, from a management perspective, it is very important to maintain fire doors and secure an appropriate replacement time. Therefore, the purpose of this study is to determine whether the fire door has durability to prevent fire spread in the process of use through operation probability analysis and expert surveys, and to propose an appropriate useful life of the fire door.

  • PDF

스크린도어가 설치된 지하철 승강장의 화재유동 전산 수치 모사를 이용한 스크린도어의 화재 영향 연구 (Effect of Platform Screen Door on fire in the subway station)

  • 장용준;정우성;박원희;김학범
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 추계학술대회 논문집
    • /
    • pp.1337-1345
    • /
    • 2007
  • 본 연구는 플랫폼 스크린도어가 설치된 역사에서 화재시 스크린도어에 의한 효과와 화재에 대한 방재연구를 체계적으로 진행하기 위한 기초연구이다. 본문에는 스크린 도어의 종류와 특징에 대하여 기술하였다. 본 연구의 대상이 되는 스크린 도어에는 완전밀폐형이 설치된 역사를 대상으로 하였으며 승강장 종류는 섬식 승강장이다. 스크린 도어가 설치된 역사의 화재유동 전산수치모사에 화재전용 CFD code를 이용하여 수행하였다. 플랫폼 스크린도어의 영향을 분석하기 위하여 스크린도어가 설치된 경우와 설치되지 않은 경우를 해석 하였다. 또한 화원의 위치는 승강장과 선로부에 있는 경우로 나누었다. 화원의 성장시나리오는 Ultrafast model로 하였으며, 화원크기는 10MW로 하였다. 해석결과 플랫폼 스크린도어가 설치된 경우는 화원의 위치가 승강장에 있을 때 온도 및 연기의 전파가 주 탈출구인 계단에까지 4분 이내로 전파된다. 선로부에 있을 때는 스크린 도어에 의해 열, 연기 전파의 차단 효과가 있었다.

  • PDF

지하상가 출입구 방풍문 설치에 따른 피난안전해석 (Evacuation Simulation for the Exit with a Windbreak Door in Underground Arcade)

  • 최영상;전흥균;추홍록
    • 한국화재소방학회논문지
    • /
    • 제23권3호
    • /
    • pp.1-10
    • /
    • 2009
  • 지하상가는 특성상 출입구에 문을 설치할 경우 피난안전에 미치는 영향을 더 면밀하게 분석할 필요가 있다. 본 연구에서는 이미 사용 중에 있는 지하상가의 출입구 중 일부 출입구에 문을 설치하는 경우에 대해 CFAST로 화재시뮬레이션을 수행하고 그 결과를 building EXODUS 피난시뮬레이션의 위험인자로 활용하여 화재위험을 고려한 피난해석을 하였다. 지하상가의 6개 출입구 중에 2곳에 문을 설치할 경우에 대해 화재피난과 일반피난으로 나누어 1,088명에 대해 피난해석을 하였다. 일반피난의 경우는 문 설치에 따른 영향이 거의 없었으나 화재피난의 경우는 문 설치로 인해 약 110초의 피난지연이 발생하였다. 또 자동문이 설치된 경우는 자동문이 열리지 않을 때가 문 설치 전보다 670초 피난지연이 발생하였다. 따라서 자동문은 화재감지기와 연동하여 개방된 상태로 정지하도록 설치되어야 하고, 문을 설치할 경우 피난안전을 위해 피난유도표시를 보강하는 것도 필요하다.

제연구역 출입문 개방 각도에 따른 폐쇄력에 관한 연구 (A Study on the Closing Force according to the Opening Angle of the Door in the Smoke Control System)

  • 오원신;정석환
    • 대한안전경영과학회지
    • /
    • 제23권4호
    • /
    • pp.43-48
    • /
    • 2021
  • In this study, the experiment was conducted on a fire door(W × H = 0.98 m × 2.19 m) installed on the vestibule. The effective leakage area for each opening angles and closing forces derived from the impulse-momentum equation was compared and analyzed with the experimental results. As a result of the experiment, the major factors affecting the door closing forces were the pressure difference and the area of the door. The difference of door closing forces between measured and calculated values by the impulse-momentum equation showed a deviation of less than ±15% at the opening angles of 5°to 10°. At the door opening angle of 2.5°, the dynamic pressure was much higher than the measured static pressure, and this pressure difference is estimated to be air resistance acting to prevent the door from being completely closed.

강철재 도어의 내화, 기밀성 향상을 위한 이중틈새 차단장치에 관한 연구 (A Study on the Double Gap Blocking Device for the Improvement of Fire Resistance and Airtightness of Steel Door)

  • 이주원;임보혁;조성권;이해열
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2023년도 봄 학술논문 발표대회
    • /
    • pp.147-148
    • /
    • 2023
  • Steel doors, which are common in general buildings, do not seal the gap between the door and the floor, so drafts, noise, dust, and lights flow from the outside, and shielding devices are installed in various materials and methods, such as adding magnetic gate paper to the side of the door or installing a gasket under the door, but performance is limited. Accordingly, in order to fundamentally solve these problems, we researched and developed a double gap blocking device that can improve fire resistance and airtightness performance in steel doors. Unlike general products, the double gap blocking device has the advantage of maximizing airtight performance by forming an air layer in the center when the door is closed, as well as greatly improving the fire resistance performance, which is the basic performance of the fire door.

  • PDF