• 제목/요약/키워드: Fire Control

검색결과 1,362건 처리시간 0.04초

Development of K-Maryblyt for Fire Blight Control in Apple and Pear Trees in Korea

  • Mun-Il Ahn;Hyeon-Ji Yang;Sung-Chul Yun
    • The Plant Pathology Journal
    • /
    • 제40권3호
    • /
    • pp.290-298
    • /
    • 2024
  • K-Maryblyt has been developed for the effective control of secondary fire blight infections on blossoms and the elimination of primary inoculum sources from cankers and newly emerged shoots early in the season for both apple and pear trees. This model facilitates the precise determination of the blossom infection timing and identification of primary inoculum sources, akin to Maryblyt, predicting flower infections and the appearance of symptoms on various plant parts, including cankers, blossoms, and shoots. Nevertheless, K-Maryblyt has undergone significant improvements: Integration of Phenology Models for both apple and pear trees, Adoption of observed or predicted hourly temperatures for Epiphytic Infection Potential (EIP) calculation, incorporation of adjusted equations resulting in reduced mean error with 10.08 degree-hours (DH) for apple and 9.28 DH for pear, introduction of a relative humidity variable for pear EIP calculation, and adaptation of modified degree-day calculation methods for expected symptoms. Since the transition to a model-based control policy in 2022, the system has disseminated 158,440 messages related to blossom control and symptom prediction to farmers and professional managers in its inaugural year. Furthermore, the system has been refined to include control messages that account for the mechanism of action of pesticides distributed to farmers in specific counties, considering flower opening conditions and weather suitability for spraying. Operating as a pivotal module within the Fire Blight Forecasting Information System (FBcastS), K-Maryblyt plays a crucial role in providing essential fire blight information to farmers, professional managers, and policymakers.

Development of CAN based Automatic Fire Detection System

  • Lee, Hong-Hee;Kim, Jung-Hee
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.695-699
    • /
    • 2003
  • It is general to use the control network in control systems in order to reduce the complexity of the related wiring harnesses and to improve the system flexibility. CAN becomes one of the most popular network protocols because of its low price, multiple sources, high performance and reliability. This paper describes a CAN based real-time control of the fire detection system for the intelligent building system. The proposed fire detection and alarm system is stronger than the previous one against noises and communication media faults and can solve many problems such as complex cabling and increment of I/O ports by using many sensors. Furthermore, MMI can be achieved easily with the personal computer that is used for replacing the traditional monitoring system. The proposed system is implemented and the experimental results are given.

  • PDF

Habitability evaluation considering various input parameters for main control benchboard fire in the main control room

  • Byeongjun Kim ;Jaiho Lee ;Seyoung Kim;Weon Gyu Shin
    • Nuclear Engineering and Technology
    • /
    • 제54권11호
    • /
    • pp.4195-4208
    • /
    • 2022
  • In this study, operator habitability was numerically evaluated in the event of a fire at the main control bench board (MCB) in a reference main control room (MCR). It was investigated if evacuation variables including hot gas layer temperature (HGLT), heat flux (HF), and optical density (OD) at 1.8 m from the MCR floor exceed the reference evacuation criteria provided in NUREG/CR-6850. For a fire model validation, the simulation results of the reference MCR were compared with existing experimental results on the same reference MCR. In the simulation, various input parameters were applied to the MCB panel fire scenario: MCR height, peak heat release rate (HRR) of a panel, number of panels where fire propagation occurs, fire propagation time, door open/close conditions, and mechanical ventilation operation. A specialized-average HRR (SAHRR) concept was newly devised to comprehensively investigate how the various input parameters affect the operator's habitability. Peak values of the evacuation variables normalized by evacuation criteria of NUREG/CR-6850 were well-correlated as the power function of the SAHRR for the various input parameters. In addition, the evacuation time map was newly utilized to investigate how the evacuation time for different SAHRR was affected by changing the various input parameters. In the previous studies, it was found that the OD is the most dominant variable to determine the MCR evacuation time. In this study, however, the evacuation time map showed that the HF is the most dominant factor at the condition of without-mechanical ventilation for the MCR with a partially-open false ceiling, but the OD is the most dominant factor for all the other conditions. Therefore, the method using the SAHRR and the evacuation time map was very useful to effectively and comprehensively evaluate the operator habitability for the various input parameters in the event of MCB fires for the reference MCR.

여드름의 화침치료 효과에 대한 체계적 문헌 고찰 (A Systematic Review on the Efficacy of Fire Needling for the Treatment of Acne)

  • 김의별;강기완;김민지;강자연;정민정;장인수
    • Journal of Acupuncture Research
    • /
    • 제33권2호
    • /
    • pp.151-164
    • /
    • 2016
  • Objectives : The purpose of this study is to review clinical studies about the efficacy of fire needling for the treatment of acne vulgaris. Methods and Results : In this review, Oasis, NDSL, CNKI, PubMed, Cochrane, J STAGE and CINII were used as the main databases for searching for medical journals, using the keywords "acne and fire needling"," acne and fire needle"," acne and fire acupuncture", and" acne and red hot needle". The initial search range included only randomized controlled trials (RCTs), and papers not matching inclusion criteria were excluded. Initially a total of 108 studies were found, with ten being excluded during title and abstract screening. After scanning 98 papers, a total of 31 RCTs were selected and analyzed. In the 31 RCTs, patients with acne were randomized into groups for treatment and control. Specifically, the treatment group received fire needling, while the control group were concurrently given other treatments. The results of the completed studies have shown that the treatment group receiving fire needling demonstrated significant improvement compared to the control group. Conclusion : During our study, it was verified that the efficacy of fire needling for the treatment of acne vulgaris was both significant and meaningful. Therefore, fire needling can be a safe and effective alternative treatment for acne. However, to confirm this result, further investigation in a traditional clinic is required, accompanied by high quality studies including randomized, placebo-controlled double-blind trials.

대규모 실내경기장의 소방방재설비 적용현황 분석 (A Study on the Application of Fire Protection Facilities in Large Enclosure Gymnasium)

  • 최동호;김춘동;양정훈;조영흠
    • 한국공간구조학회논문집
    • /
    • 제10권2호
    • /
    • pp.135-145
    • /
    • 2010
  • 본 논문은 사례조사를 통해 국내외 대규모 실내경기장의 소방방재계획상의 특정을 분석함으로서 향후 국내에 건립될 대공간 건축물의 소방방재계획 수립에 활용될 기초자료를 도출코자 하였다. 본 논문에서는 국내의 소방방재설비관련 법규 검토와 국내 3개, 국외 8개의 대규모 실내경기장을 대상으로 화재감지설비 소화설비 배연설비 피난계획 적용현황을 조사하여 대공간의 소방방재시스템의 동향을 파악하고 이들을 비교, 분석하였다. 연구 결과 대규모 실내경기장의 화재감지설비는 공간특성에 적합한 적외선화재감지기, 염감지기 등이 유력한 화재감지설비로 사용되며, 소화설비는 건식살수설비, 방수총소화설비 등이 채택되었으며 배연에서는 축연시스템이 적극 활용됨을 확인하였다.

  • PDF

노인을 위한 소방안전교육 프로그램 개발 및 효과분석 (Study on the Development and the Effects of a Fire Safety Education Program for the Elderly)

  • 김영도;김영빈
    • 한국화재소방학회논문지
    • /
    • 제32권3호
    • /
    • pp.123-133
    • /
    • 2018
  • 본 연구의 목적은 노인을 위한 소방안전교육 프로그램을 개발하고, 이 프로그램이 노인의 소방안전지식과 소방안전사고예방실천에 미치는 효과를 알아보는 것이다. 프로그램은 기초조사와 문헌고찰을 토대로 목적과 목표, 내용, 교수학습방법을 선정한 후 전문가 검증과 예비조사를 거쳐 개발하였다. 효과검증은 65세 이상 노인 48명을 실험군(노인을 위한 소방안전교육 프로그램 실시)과 대조군(인쇄된 강의자료만 제공)으로 나누어 비동등성 대조군 사전사후검사를 실시하였다. 각 집단의 사전-사후 검사점수를 대응표본 t-검증으로 분석한 결과, 프로그램을 실시한 실험군과 인쇄자료만 제공한 대조군 모두 사전-사후 점수 간에 통계적으로 유의미한 차이를 보였다. 그리고 공변량분석(ANCOVA) 결과 실험군의 사후검사 점수가 대조군의 사후검사 점수보다 높게 나타나, 인쇄자료에 비해 프로그램의 효과가 유의미하게 높음을 확인하였다.

지하역사 화재발생시 제연모드에 따른 승객피난 예측 (Simulations of the Passenger Evacuation in a Fire occurred Underground Station under Various Smoke-Control Ventilation Modes)

  • 박원희;이한수;장희철;장용준
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 추계학술대회 논문집
    • /
    • pp.1213-1217
    • /
    • 2007
  • In this paper some sets of numerical simulations for passenger evacuation in a fire occurred underground station under various smoke-control ventilation modes. Passenger evacuation flows are calculated by EXODUS program. As input data for EXODUS program, distributions of temparature, smoke and toxicity due to fire in the underground station are evaluated by Fire Dyanamic Simulator (FDS).

  • PDF

방화셔터를 이용한 아트리움 제연과 피난안전에 관한 수치해석 연구 (A Numerical Study for the Atrium Smoke Control by Fire Shutter and Evacuation)

  • 전흥균;최영상;추홍록
    • 한국화재소방학회논문지
    • /
    • 제24권5호
    • /
    • pp.50-59
    • /
    • 2010
  • 본 연구에서는 대구 D대학 기숙사 건물에 대해 2MW, 5MW 화재크기와 아트리움 방화셔터의 미설치 및 작동 경우의 4가지 화재시나리오를 구성하고, FDS(ver. 5.5.0)와 Pathfinder 2009 프로그램을 사용하여 화재 및 피난시뮬레이션을 수행하였다. 화재피난영향평가를 통하여 방화셔터와 배연구의 아트리움 제연 효과에 대한 성능을 확인하였고, 화재위험 및 피난안전을 분석하였다. 방화셔터의 작동은 연기 전파 방지에 큰 효과가 있지만, 상부 배연구를 통한 배연량이 불충분하여 방화셔터의 유무에 관계없이 연기층은 바닥으로부터 약 2m 지점까지 하강하고, 본 연구에서 설정한 연기층 한계 높이 이하가 되었다. 또 방화셔터 미설치, 5MW 화재크기의 경우, 온도보다 가시거리에 의한 화재위험 가능성이 더 크게 나타났고, 기숙사 중.상부 층의 계단실 피난여유시간은 약 5초 이내로 매우 작았다. 지상 1층 주출입구까지 전체 피난자의 순수 피난이동시간은 136초이다. 피난자의 더 안전한 피난을 위해 추가적인 보완조치가 필요하다고 사료된다.