• Title/Summary/Keyword: Fins

Search Result 728, Processing Time 0.028 seconds

Growth and Spawning Ecology of Cobitis lutheri (Teleostei: Cobitidae) in the Mangyeong River, Korea (만경강 삼천에 서식하는 점줄종개 Cobitis lutheri의 성장과 산란상태)

  • Ko, Myeong-Hun;Park, Jong-Yeong
    • Korean Journal of Ichthyology
    • /
    • v.23 no.2
    • /
    • pp.158-162
    • /
    • 2011
  • Growth and spawning ecology of Cobitis lutheri (Teleoste: Cobitidae) were investigated in the Samcheon Stream, Mangyeong River, Jeollabuk-do, Korea from 2005 to 2006. Age group of C. lutheri estimated from the total length indicated that the 40 ~ 60 mm group is 1 year old, the 60 ~ 80 mm group is 2 years old, and the 80 ~ 110mm group is 3 ${\leq}$ years old. The sex ratio (Male/Female) was 0.78, and the female was 20 ~ 30 mm larger than the male. Lamina circularis at the base of pectoral fins in the males as a secondary sexual character was created 12 months after hatching. A change of lateral coloration of males was observed from April to September. The spawning season was early to middle July with water temperatures of $24{\sim}26^{\circ}C$. The average number of eggs was $1,127{\pm}453$ with the egg diameter of $1.09{\pm}0.02$ mm.

Measurement of Performance of High Speed Under Water Vehicle by Using Solid Rocket Motor(II) (로켓추진을 이용한 고속 수중운동체의 수중 주행성능 측정 결과(II))

  • Yoon, Hyun-Gull;Lee, Hoy-Nam;Cha, Jung-Min;Lim, Seol;Suh, Suhk-Hoon
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.131-136
    • /
    • 2017
  • High speed under water vehicle by using solid rocket motor, which is a natural cavitation type, was tested. The vehicle's speed and running distance was measured, and pressure sensors installed on the surface of the vehicle show pressure-time history of pressures according to the development of the supercavitation. Underwater cameras installed on the wall of the test pool recorded whole processes from the onset of the supercavitation to fully developed one. CNU-SuperCT based on 2-dimensional inviscid theoretical analysis was used to simulate the test result. In consideration of CNU-SuperCT does not include the control fins of the vehicle, simulation results agree with test results very well. Also, pictures from underwater cameras support the test results.

  • PDF

An Analysis of he Foreign Exchange Exposure and Determinants (개별기업의 환노출과 결정요인에 관한 연구)

  • Lee, Hyon-Sok
    • The Korean Journal of Financial Management
    • /
    • v.21 no.2
    • /
    • pp.65-98
    • /
    • 2004
  • This paper analyzes the foreign exchange exposure and the influence of determinants on the significant exposure under various return horizons of US dollar and the Japanese yen. Also this research is extended to the existence of asymmetric exposures to foreign exchange risk. The exchange rate exposures exhibit significant time variations that are very large to represent changes in cash flow sensitivities, but the relation of the significant exposures and time variations is not monotonically increasing. The extent to which a firm is exposed to exchange rate fluctuations can be explained by the level of the growth potential, nm size and leverage. For the various return horizons, firms with a higher growth potential tend to have higher exposures. And the larger firms' exposures tend to be smaller. The influences of the level of export ratio and leverage vary with return horizons and each periods. It is found that the exposures of fins are asymmetric. The asymmetry is mainly explained by the market share hypothesis. The level of export ratio commonly influences the asymmetric exposures to the US dollar and the Japanese yen.

  • PDF

Analysis of Broad-Band Electromagnetic Wave Absorber for Single Polarized Wave by the Equivalent Material Method and the FDTD Method (등가재료정수법 및 FDTD법에 의한 단일편파용 광대역 전파흡수체의 해석)

  • 이수영;김동일;이종헌
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.9 no.3
    • /
    • pp.296-304
    • /
    • 1998
  • A design method of an electromagnetic wave absorber with ferrite fins in the second layer, which has very wide band frequency characteristics and is used for single-polarized wave absorption such as TV wave etc, has been designed. To examine the effectiveness of the Equivalent Material Constants Method$(EMCM)^{[1]}$ which is approximate method, the effective complex permittivity calculated by the Hashin-Strikman formulas and the EMCM are compared. Since, furthermore, the reflectivities by the EMCM in space and the FDTD method in an rectangular waveguide agreed well each other, it has been confirmed that the proposed electromagnetic wave absorber has excellent absorption characteristics in the frequency range of 30 MHz to 5830 MHz. Thus, it can be concluded that the EMCM is usefull to design and analyze the electro-magnetic wave absorber proposed here.

  • PDF

Numerical Analysis for Thermal Design of Electronic Equipment Using Phase Change Material (상변화 물질을 이용한 전자 장비 방열 설계의 수치 해석적 연구)

  • Lee, Dong Kyun;Lee, Won Hee;Park, Sung Woo;Kang, Sung Wook;Cho, Ji Hyun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.41 no.4
    • /
    • pp.285-291
    • /
    • 2017
  • In this study, a case analysis for thermal design of electronic equipment using a phase change material(PCM) was performed numerically using ANSYS Fluent. Experiments were conducted to find the temperature increase(${\Delta}T_m$), melting temperature($T_m$), and volume expansion of the PCM under the melting process. To verify the accuracy of the Fluent solver model, $T_m$, ${\Delta}T_m$, and the melting time were compared with experimental results. To simulate the temperature stagnation phenomenon under the melting process, the equivalent specific heat method was applied to calculate the thermal properties of the PCM in the solver model. To determine the thermal stability of electronic equipment, we paid special attention to finding a thermal design for the PCM using fins. Further, an additional numerical analysis is currently underway to find an optimum design.

Effects of Feeder Cells on the Primary Culture of Ovarian Cell Populations from Adult Japanese Medaka (Oryzias latipes)

  • Ryu, Jun Hyung;Gong, Seung Pyo
    • Journal of Animal Reproduction and Biotechnology
    • /
    • v.35 no.1
    • /
    • pp.65-72
    • /
    • 2020
  • Fish ovarian germline stem cells (OGSCs) that have the abilities to self-renew and differentiate into functional gametes can be used in various researches and applications. A main issue to be solved for effective utilization of fish OGSCs is the development of their stable in vitro culture condition, but only few researches about fish OGSC culture have been reported so far. In this study, in order to find the clues to develop the culture condition for OGSCs from Japanese medaka (Oryzias latipes), we tried to establish somatic cell lines as a candidate for the feeder cells and evaluated its supporting effects on the culture of ovarian cell populations from O. latipes. As the results, the somatic cell lines could be established only from the embryonic tissues among three tissues derived from embryos, fins and ovaries. Three embryonic cell lines were tested as a feeder cell for the culture of ovarian cell population and all three cell lines induced cell aggregation formation of the cultured ovarian cells whereas the feeder-free condition did not. Furthermore, a significant cellular proliferation was observed in the ovarian cells cultured on two of three cell lines. As a trial to increase the capacity of the cell lines as a feeder cell that supports the proliferation of the cultured ovarian cells, we subsequently established a stable line that expresses the foreign O. latipes fibroblast growth factor 2 (FGF2) from an embryonic cell line and evaluated its effectiveness as a feeder cell. The ovarian cells cultured on FGF2 expressing feeder cells still formed cell aggregates but did not show a significant increase in cellular proliferation compared to those cultured on non-transformed feeder cells. The results from this study will provide the fundamental information for in vitro culture of medaka OGSCs.

Stability Analysis on Guided Munition at Slow Spin (유도포탄 저속 회전 시 안정성 분석)

  • Kim, Youngjoo;Bang, Hyochoong;Seo, Songwon;Pak, Chang-Ho;Kim, Jin-Won;Seo, Ilwon
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.46 no.9
    • /
    • pp.752-759
    • /
    • 2018
  • This paper presents methods and results of nonlinear simulations for a guided munition for verifying stability at slow spin. The munition is launched by an artillery and it deploys the rear fins to reduce its spin. While the spin speed command is set to 1 rps and 3 rps, wind gusts of 3m/s, 7m/s, 10m/s, and 15m/s in amplitude, and 26 different directions were generated as disturbance for each simulation run. Whereas the munition with the spin speed of 3 rps didn't flip, that with 1-rps spin flipped under some gusts. However, the gusts which increase airspeed in the flight direction didn't introduce harmful effect. Most importantly, all the flips of the munition was observed near the end of the simulation where the munition is going down. No problem was observed near the summit of trajectory.

An Experimental Study on Air-Side Performance of Fin-and-Tube Heat Exchangers Having Compound Enhanced Fins Under Wet Condition (복합 전열 촉진 핀이 적용된 핀-관 열교환기의 습표면 성능에 대한 실험적 연구)

  • Kim, Nae-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.9
    • /
    • pp.5778-5788
    • /
    • 2015
  • In this study, wet surface heat transfer and friction characteristics of compound enhanced fin-and-tube heat exchangers were experimentally investigated. Louver-finned heat exchangers were also tested for comparison purpose. The effect of fin pitch on j and f factor was negligible. Both j and f factor decreased as number of tube row increased. Compound enhanced fin samples yielded higher j and f factors than louver fin samples. For one row, j and f factors of compound enhanced fin samples were 11% and 43% higher than those of louver fin samples. For two row, those were 8% and 50%, and for three row, those were 17% and 53%. Heat transfer capacities at the same pressure drop of the compound enhanced fin samples were 2.0% for one row, 3.1% for two row and 8.4% for three row larger than those of louver fin samples, Data were compared with predictions of existing louver fin correlations.

Air-Side Performance of Fin-and-Tube Heat Exchangers Having Non-Symmetric Slit Fins Under Wet Condition (비대칭형 슬릿 핀이 적용된 핀-관 열교환기의 습표면 성능)

  • Kim, Nea-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.6
    • /
    • pp.3698-3707
    • /
    • 2015
  • In this study, wet surface heat transfer and friction characteristics of non-symmetric slit-finned heat exchangers are experimentally investigated. Louver-finned heat exchangers are also tested for comparison purpose. The effect of fin pitch on j and f factor is negligible. Louver fin samples yield higher j and f factors than slit fin samples. For one row, j and f factors of louver fin are 27% and 31% higher than those of slit fin. For two row, j and f factors of louver fin are 15% and 30% higher. Both j and f factor decrease as the number of tube row increases. For one row, average j/f ratios of slit fin samples are 3.4% larger than those of louver fin samples. For two row, average j/f ratios of slit fin samples are 11.5% larger. A new correlation was developed using the present data.

Performance Characteristics of Vehicle Air Conditioning System Using Internal Heat Exchanger with Inner Fin (휜 타입 내부열교환기 적용에 따른 차량용 냉방시스템 성능 특성)

  • Kim, Sung Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.1
    • /
    • pp.69-73
    • /
    • 2013
  • Internal heat exchanger (IHX) apparatus using the temperature difference between high and low pressure lines in vehicle air conditioning system is a good method to enhance the cooling performance. In this study, we designed various double-pipe internal heat exchangers which have inner fins between the internal pipe and external pipe. We also measured the performance characteristic (pressure drop, cooling capacity, compressor work and coefficient of performance (COP)) of the modified internal heat exchangers that had the change of the fin height and the inside shape of the internal pipe. This experimental results indicated that the liner and serration type internal heat exchanger was the best cooling performance. In addition, the air conditioning system with the liner and serration type internal heat exchanger showed the improved performances of about 6.4% and 9.2%, respectively, for the cooling capacity and COP.