• 제목/요약/키워드: Finite Region

검색결과 1,242건 처리시간 0.04초

임플란트 지지 캔틸레버 고정성 보철물 장착시 과두와 하악골의 응력 분포에 관한 3차원 유한요소법적 연구 (A Study on the Stress Distribution of Condylar Region and Edentulous Mandible with Implant-Supported Cantilever Fixed Prostheses by using 3-Dimensional Finite Element Method)

  • 김연수;이성복
    • 구강회복응용과학지
    • /
    • 제17권4호
    • /
    • pp.283-305
    • /
    • 2001
  • The purpose of this study was to analyze the stress distribution of condylar regions and edentulous mandible with implant-supported cantilever prostheses on the certain conditions, such as amount of load, location of load, direction of load, fixation or non-fixation on the condylar regions. Three dimensional finite element analysis was used for this study. FEM model was created by using commercial software, ANSYS(Swanson, Inc., U.S.A.). Fixed model which was fixed on the condylar regions was modeled with 74323 elements and 15387 nodes and spring model which was sprung on the condylar regions was modeled with 75020 elements and 15887 nodes. Six Br${\aa}$nemark implants with 3.75 mm diameter and 13 mm length were incorporated in the models. The placement was 4.4 mm from the midline for the first implant; the other two in each quardrant were 6.5 mm apart. The stress distribution on each model through the designed mandible was evaluated under 500N vertical load, 250N horizontal load linguobuccally, buccal 20 degree 250N oblique load and buccal 45 degree 250N oblique load. The load points were at 0 mm, 10 mm, 20 mm along the cantilever prostheses from the center of the distal fixture. The results were as follows; 1. The stress distribution of condylar regions between two models showed conspicuous differences. Fixed model showed conspicuous stress concentration on the condylar regions than spring model under vertical load only. On the other hand, spring model showed conspicuous stress concentration on the condylar regions than fixed model under 250N horizontal load linguobuccally, buccal 20 degree 250N oblique load and buccal 45 degree 250N oblique load. 2. Fixed model showed stress concentration on the posterior and mesial side of working and balancing condylar necks but spring model showed stress concentration on the posterior and mesial side of working condylar neck and the posterior and lateral side of balancing condylar neck under vertical load. 3. Fixed model showed stress concentration on the posterior and lateral side of working condylar neck and the anterior and mesial side of balancing condylar neck but spring model showed stress concentration on the anterior sides of working and balancing condylar necks under horizontal load linguobuccally. 4. Fixed model showed stress concentration on the posterior side of working condylar neck and the posterior and lateral side of balancing condylar neck but spring model showed stress concentration on the anterior side of working condylar neck and the anterior and lateral side of balancing condylar neck under buccal 20 degree oblique load. 5. Fixed model showed stress concentration on the anterior and lateral side of working condylar neck and the posterior and mesial side of balancing condylar neck but spring model showed stress concentration on the anterior side of working condylar neck and the anterior and lateral side of balancing condylar neck under buccal 45 degree oblique load.. 6. The stress distribution of bone around implants between two models revealed difference slightly. In general, magnitude of Von Mises stress was the greatest at the bone around the most distal implant and the progressive decrease more and more mesially. Under vertical load, the stress values were similar between implant neck and superstructure vertically, besides the greatest on the distal side horizontally. 7. Under horizontal load linguobuccally, buccal 20 degree oblique load and buccal 45 degree oblique load, the stress values were the greatest on the implant neck vertically, and great on the labial and lingual sides horizontally. After all, it was considered that spring model was an indispensable condition for the comprehension of the stress distributions of condylar regions.

  • PDF

상악 임플란트 피개의치에서 유지장치 종류와 구개 피개 유무에 따른 응력분포에 대한 유한요소분석 (Effect of attachments and palatal coverage of maxillary implant overdenture on stress distribution: a finite element analysis)

  • 박종희;왕원곤;이정진;박연희;서재민;김경아
    • 구강회복응용과학지
    • /
    • 제36권2호
    • /
    • pp.70-79
    • /
    • 2020
  • 목적: 상악 임플란트 피개의치에서 유지장치 종류와 구개 피개 유무에 따른 응력분포를 3차원 유한요소분석법을 통해 알아보고자 한다. 연구 재료 및 방법: CAD를 이용하여 전방부에 4개의 임플란트를 식립한 4종류의 상악 임플란트 피개의치에 대한 3차원 모델을 디자인하였다. 1) Ball-F: 볼 유지장치를 사용하고 구개를 피개한 군, 2) Ball-P: 볼 유지장치를 사용하고 구개를 피개하지 않은 군, 3) Bar-F: 바 유지장치를 사용하고 구개를 피개한 군, 4) Bar-P: 바 유지장치를 사용하고 구개를 피개하지 않은 군. 응력분석은 유한요소 분석 프로그램인 ANSYS Workbench Ver. 14를 사용하였으며, 편측 저작의 상황을 고려하여 우측 제1대구치에 100 N의 정적하중을 적용하여 임플란트, 임플란트 주위 골, 점막에 발생하는 최대 응력값을 기록하였다. 결과: 볼 유지장치를 사용한 군이 바 유지장치를 사용한 군보다 임플란트 및 임플란트 주위골에 발생하는 최대 응력값이 작았다. 하지만 점막에서의 최대 응력값은 그 반대로 나타났다. 구개를 피개하면 유지장치의 종류와 무관하게 임플란트, 임플란트 주위 골, 점막 모두에서 최대응력값이 작아졌다. 결론: 본 연구의 한계 내에서 상악동 전방부에 4개의 임플란트를 식립하여 수복된 피개의치에서 바 유지장치보다는 볼 유지장치를 사용하고 구개를 완전히 피개하는 경우가 임플란트와 임플란트 주위 골의 응력분산에 효과적이다.

EFFECT OF NUMBER OF IMPLANTS AND CANTILEVER DESIGN ON STRESS DISTRIBUTION IN THREE-UNIT FIXED PARTIAL DENTURES: A THREE-DIMENSIONAL FINITE ELEMENT ANALYSIS

  • Park, Ji-Hyun;Kim, Sung-Hun;Han, Jung-Suk;Lee, Jai-Bong;Yang, Jae-Ho
    • 대한치과보철학회지
    • /
    • 제46권3호
    • /
    • pp.290-297
    • /
    • 2008
  • STATEMENT OF PROBLEM: Implant-supported fixed cantilever prostheses are influenced by various biomechanical factors. The information that shows the effect of implant number and position of cantilever on stress in the supporting bone is limited. PURPOSE: The purpose of this study was to investigate the effect of implant number variation and the effect of 2 different cantilever types on stress distribution in the supporting bone, using 3-dimensional finite element analysis. MATERIAL AND METHODS: A 3-D FE model of a mandibular section of bone with a missing second premolar, first molar, and second molar was developed. $4.1{\times}10$ mm screw-type dental implant was selected. 4.0 mm height solid abutments were fixed over all implant fixtures. Type III gold alloy was selected for implant-supported fixed prostheses. For mesial cantilever test, model 1-1 which has three $4.1{\times}10$ mm implants and fixed prosthesis with no pontic, model 1-2 which has two $4.1{\times}10$ mm implants and fixed prosthesis with a central pontic and model 1-3 which has two $4.1{\times}10$ mm implants and fixed prosthesis with mesial cantilever were simulated. And then, 155N oblique force was applied to the buccal cusp of second premolar. For distal cantilever test, model 2-1 which has three $4.1{\times}10$ mm implants and fixed prosthesis with no pontic, model 2-2 which has two $4.1{\times}10$ mm implants and fixed prosthesis with a central pontic and model 2-3 which has two $4.1{\times}10$ mm implants and fixed prosthesis with distal cantilever were simulated. And then, 206N oblique force was applied to the buccal cusp of second premolar. The implant and superstructure were simulated in finite element software(Pro/Engineer wildfire 2.0). The stress values were observed with the maximum von Mises stresses. RESULTS: Among the models without a cantilever, model 1-1 and 2-1 which had three implants, showed lower stress than model 1-2 and 2-2 which had two implants. Although model 2-1 was applied with 206N, it showed lower stress than model 1-2 which was applied with 155N. In models that implant positions of models were same, the amount of applied occlusal load largely influenced the maximum von Mises stress. Model 1-1, 1-2 and 1-3, which were loaded with 155N, showed less stress than corresponding model 2-1, 2-2 and 2- 3 which were loaded with 206N. For the same number of implants, the existence of a cantilever induced the obvious increase of maximum stress. Model 1-3 and 2-3 which had a cantilever, showed much higher stress than the others which had no cantilever. In all models, the von Mises stresses were concentrated at the cortical bone around the cervical region of the implants. Meanwhile, in model 1-1, 1-2 and 1-3, which were loaded on second premolar position, the first premolar participated in stress distribution. First premolars of model 2-1, 2-2 and 2-3 did not participate in stress distribution. CONCLUSION: 1. The more implants supported, the less stress was induced, regardless of applied occlusal loads. 2. The maximum von Mises stress in the bone of the implant-supported three unit fixed dental prosthesis with a mesial cantilever was 1.38 times that with a central pontic. The maximum von Mises stress in the bone of the implant-supported three-unit fixed dental prosthesis with a distal cantilever was 1.59 times that with a central pontic. 3. A distal cantilever induced larger stress in the bone than a mesial cantilever. 4. A adjacent tooth which contacts implant-supported fixed prosthesis participated in the stress distribution.

중간 지대치가 존재하는 고정성 국소의치에서 보철물 설계 및 치조골 상태가 응력분포에 미치는 영향 (Effect of prosthetic designs and alveolar bone conditions on stress distribution in fixed partial dentures with pier abutments)

  • 조욱;김창섭;전영찬;정창모
    • 대한치과보철학회지
    • /
    • 제47권3호
    • /
    • pp.328-334
    • /
    • 2009
  • 연구목적: 하악 제 1 소구치 및 제 1 대구치가 결손 되어 중간 지대치를 갖는 5 본 고정성 국소의치에서 비고정형 어태치먼트의 설계 유무 및 지대치의 지지골 상태에 따른 변위 및 응력분포의 차이를2 차원 유한요소분석을 통해 비교하여 보고자 하였다. 연구 재료 및 방법: 5 본 고정성 국소의치는 일체형과 분할형으로 구분하였으며, 분할형에는 제 2 소구치와 제 1 대구치 사이에 비고정형 어태치먼트를 설계하였다. 지지골은 모두 정상인 경우와 세 개 지대치중 한 개의 지대치에서 임상적 치관 대 치근 비율이 6 : 4 정도까지 골 흡수가 일어난 세 가지 경우를 가정하여 총 네 가지의 지지골 상태를 설정하였다. 제 1 소구치와 제 1 대구치 가공치 중앙에 각각 150 N의 수직 분산하중과, 제 1 대구치 가공치 중앙에 300 N의 수직 집중하중을 가하였다. 결과: 일체형과 분할형 고정성 국소의치 모두에서 하중 시 하방 변위를 보였다. 분할형 고정성 국소의치에서 일체형보다 전방 지대치 지지골에서의 응력은 감소하였으나 중간 및 후방 지대치 지지골에서의 응력은 증가하였다. 지대치의 치조골 흡수가 있는 경우 해당 지대치의 지지골에 국소적인 응력 증가가 나타났다. 결론: 중간 지대치를 갖는 고정성 국소의치를 설계할 경우 유지 장치의 유지 능력과 지대치의 지주 상태 그리고 어태치먼트의 사용에 대한 주의 깊은 고찰이 필요하겠다.

비정규격자계 해양순환 모델을 이용한 하구에서의 담수 유출분석 (Fresh Water Flume Analysis Using an Unstructured Grid Ocean Circulation Model)

  • 황진환;박영규
    • 한국해양환경ㆍ에너지학회지
    • /
    • 제12권4호
    • /
    • pp.227-234
    • /
    • 2009
  • 강에서 유출된 담수가 연안지역에 영향을 미치는 영역을 결정하는 요인 중 하나인 담수풍선의 특성을 비정규격자계를 사용하는 유한체적모델(FVCOM)을 이용하여 연구하였다. 강에서 바다로 유출된 담수는 하류 쪽(강에서 바다를 보면서 오른쪽)으로 이동하는 연안경계류와 강 하구에서 반시계방향으로 회전하며 시간이 지남에 따라 커지는 와류형태의 담수풍선(bulge)을 만든다. 이 담수풍선의 중심에서 수직운동이 유도되어 담수가 해저면 까지 이동한다. 조석을 고려하면 담수풍선이 사라지고, 연안경계류의 폭이 넓어진다. 간단한 염분비교방법을 이용하여 조석에 의한 성층 및 혼합의 변화를 비교하여 조석이 연직혼합을 강화시킴을 정량적으로 평가하였다. 담수가 방출되기 시작한 초기에는 조석에 의한 왕복운동에 의해 조석이 고려된 경우에 수평혼합이 더 크게 나타나나, 일정시간이 지나면 수직혼합에 의해 하구역의 염분이 낮아져 있어, 강 하구에서 담수의 왕복운동이 전체적인 수평 확산계수에 미치는 영향이 작아진다. 조석이 없는 경우 연직혼합 없이 주로 표층에서만 관성불안정에 의해 수평 확산/혼합이 이루어져 수평 확산계수가 시간이 지남에 따라 계속 증가한다.

  • PDF

비정상 음향신호 필터링을 통한 플랜트 가스누출 위치 탐지기법 (Detection of Abnormal Leakage and Its Location by Filtering of Sonic Signals at Petrochemical Plant)

  • 윤영삼;김철
    • 대한기계학회논문집B
    • /
    • 제36권6호
    • /
    • pp.655-662
    • /
    • 2012
  • 심각한 사고를 초래하는 석유화학 플랜트의 가스 누출 여부와 위치를 실시간으로 탐지하기 위하여 주변의 여러 기계소음 등으로부터 비정상적 누출 음향을 분리할 수 있는 기법을 제시하였다. LMS 알고리즘을 이용하여 FIR구조의 적응필터와 누출 탐지용 상호상관함수를 이용하여, LABVIEW를 통하여 누출예측프로그램을 개발하였고 직접 제작한 장비를 이용하여 잔향실에서 실험을 수행하였다. 홀 사이즈, 압력, 거리, 주파수를 인자로 하여 비정상적 누출소음에 대한 실험에서 얻어진 데이터를 분석한 결과, 암소음은 1kHz 대역 이하에서 주로 발생하고 누출에 의한 소음신호는 고주파 대역, 특히 16kHz의 대역에서 가장 잘 발생한다는 것을 알게 되었다. 이런 음향기법의 가능성을 확인하기 위해서 실제로 정유공장에서 소음을 측정한 결과, 펌프와 압축기에서의 소음신호가 각각 2kHz, 4.5kHz로 측정됨으로써 주변 환경 소음과 누출음이 구별 가능하고 누출 위치(거리)의 탐지가 가능함을 밝혔다.

혼성방파제의 케이슨에 작용하는 파압과 선단 주변에서 파랑특성에 관한 3차원수치시뮬레이션 (3D-Numerical Simulation of Wave Pressure Acting on Caisson and Wave Characteristics near Tip of Composite Breakwater)

  • 최군호;전재형;이광호;김도삼
    • 한국해안·해양공학회논문집
    • /
    • 제32권3호
    • /
    • pp.180-201
    • /
    • 2020
  • 유한길이의 혼성방파제 선단에서 발생되는 회절파의 영향으로 방파제 길이를 따라 중복파고가 변동하고, 이로 인하여 케이슨에 작용하는 파압이 공간적으로 변동하며, 또한 케이슨의 활동거리가 상이한 사행피해가 발생한다는 것은 잘 알려져 있다. 제체에 작용파력의 공간적인 변동은 2차원적인 실험이나 수치해석으로서는 접근될 수 없는 문제이다. 본 연구는 olaFlow 모델을 적용하여 고천단의 사석마운드 상에 놓인 케이슨의 선단 주변에서 회절파의 발생과 배후역으로의 영향 및 제체에 작용하는 충격쇄파압을 포함한 파압의 공간적인 변동 등을 2차원 및 3차원수치기법으로 접근한다. 또한, 수치해석에서는 혼성방파제 주변에서 평균파고, 평균수평유속 및 평균난류운동에너지의 변동특성을 면밀히 분석·검토한다. 이로부터 동일한 입사파랑에 대해 케이슨에 작용하는 파압분포가 방파제의 길이에 따라 크게 변동하며, 2차원수치해석에서는 발생되지 않았든 충격쇄파압이 3차원수치해석에서는 발생되는 경우가 나타나고, 충격쇄파압의 발생 시 경우에 따라 기존의 설계조건보다 매우 큰 파압이 정수면 근방의 케이슨 전면 벽체에 작용되는 등의 중요한 결과를 확인할 수 있었다.

익산 지역의 지하수 유동 모델 (Groundwater Flow Model of Igsan Area)

  • 함세영;김연기
    • 자원환경지질
    • /
    • 제22권4호
    • /
    • pp.381-393
    • /
    • 1989
  • 익산지역의 지하수 유동계를 평가하기 위한 수리지질학적 모델링이 수행되었다. 연구지역의 범위는 $790km^2$이다. 본 지역의 지질은 쥬라기의 대보화강암과 편마상화강암 그리고 선캠브리아기의 변성암으로 구성되어 있다. 채수량은 편마상화강암지역에서 가장 높으며 이는 10km내지 25m두께의 비교적 두껍게 발달된 풍화대 때문이다. 본 모델 시뮬레이션에는 콜로라도 주립대학의 유한차분법모델이 사용되었다. 본 모델은 불균일한 격자간격을 가지며, 28행과 31열로 이루어져 있다. 본 모델은 정류상태와 부정류상태에서 보정되었다.. 정류상태 시뮬레이션의 결과를1985년 9월의 수위등고선과 비교하여 투수율과 우기의 순충전률을 결정하였다. 부정류상태 시뮬레이션은 지하수 채수에 따른 대수층의 반응을 알기 위한 것이다. 부정류상태를 보정에서는 1986년5월의 수위등고선과 맞춤으로서 비산출율의 크기와 분포 그리고 건기의 채수량과 충전량을 결정하였다. 보정된 모델을 이용하여 1985년 10월부터 1995년 9월까지의 지하수채수 및 자연적인 충전에 의한 지하수위변동을 예측하여 보았다. 보정된 모델은 광역적인 지하수개발계획에 이용될 수 있다. 그러나 국부적인 지하수위변동을 예측하는데는 이용될 수 없다.

  • PDF

중앙집중식 컨트롤러 고소작업차의 고소리프트의 구조안정성 평가 (Centralized Controller High-altitude Work Car Elevations Lift Structure Safety Assessment)

  • 김준태;이기영;이상식;박원엽
    • 한국정보전자통신기술학회논문지
    • /
    • 제10권4호
    • /
    • pp.350-357
    • /
    • 2017
  • 본 연구는 선행 연구로 진행되었던 수직상승형 고소작업차의 개발을 위한 구조해석 및 원격 제어를 포함한 중앙집중식 컨트롤러 및 유압식 상승리프트 개발에 관한 사후 연구로 진행되었다. 기존에 연구를 진행하면서 개발하였던 고소리프트의 구조 변경을 통하여 안전성 검토를 실시하였다. Solidworks로 3D 모델링을 진행하였으며, Hypermesh S/W를 통하여 유한요소의 모델을 생성하였다. 또한, 평가를 위한 작업차의 적재 환경은 작업 테이블에 위치별(전체, 상좌, 상우, 하좌, 하우)로 적재량이 250 kg인 조건, 작업 테이블에 위치별(전체, 상좌, 상우, 하좌, 하우)로 적재량이 600kg인 조건으로 하여 구조해석을 진행하여 다방면으로 안전성을 검토하였다. 그 결과 허용 적재량 250 kg과 초과 적재량 600 kg에 대해서 최대응력이 발생하는 부품을 제외한 결과를 살펴보면(Case-11 제외), 응력 수준은 항복강도 이하임을 알 수 있다. Case-11의 경우에는 최대응력이 발생하는 부품을 제외한 후에도 상단의 안전바 중앙 지지부에서 항복강도를 초과하는 영역이 존재하지만, 최대응력이 발생하는 부품과 같이 전체 구조물의 안전성 측면에는 영향을 미치지 않을 것으로 사료된다. 변위(처짐) 결과를 살펴보게 되면, 모든 경우에 있어서 동일하게 테이블에서 최대 처짐이 발생하는 것을 알 수 있으며, 250 kg과 600 kg 모두 처짐이 발생하는 경향은 동일한 것으로 나타났다.

콘크리트 구조부재의 2차원 스트럿-타이 모델 설계를 위한 컴퓨터 그래픽 프로그램 (A Computer Graphics Program for 2-Dimensional Strut-tie Model Design of Concrete Members)

  • 윤영묵
    • 대한토목학회논문집
    • /
    • 제37권3호
    • /
    • pp.531-539
    • /
    • 2017
  • 스트럿-타이 모델 방법은 응력교란영역을 갖는 콘크리트 구조부재의 설계에 효과적인 방법으로 알려져 있으며, 세계 주요 설계기준서에 채택되고 있다. 그러나 스트럿-타이 모델 방법에 의한 콘크리트 구조부재의 설계과정은 스트럿-타이 모델의 형성, 스트럿 및 타이의 필요단면적의 결정, 스트럿 및 절점영역의 강도검토 등으로 인한 반복적인 수치해석과정, 많은 도식적 계산과정, 엄청난 시간과 노력, 그리고 여러 단계에서의 설계자의 주관적인 판단 등을 필요로 하는 단점을 내포하고 있다. 이 연구에서는 스트럿-타이 모델 설계과정 상의 단점을 극복하여 모든 콘크리트 구조부재의 스트럿-타이 모델 해석 및 설계를 전문적이며 효과적으로 수행할 수 있는 컴퓨터 그래픽 프로그램을 개발하였다. 이 연구의 컴퓨터 그래픽 프로그램은 평면고체 및 평면트러스의 선형 및 재료비선형 해석을 위한 모든 종류의 경계조건을 소화할 수 있는 유한요소해석 프로그램, 스트럿 및 절점영역 유효강도의 자동적 결정을 위한 수치해석 프로그램, 다양한 형태의 스트럿 및 절점영역의 형상 결정을 위한 그래픽 프로그램 등을 포함한 콘크리트 구조부재의 스트럿-타이 모델 해석 또는 설계과정 상에 필요한 모든 프로그램을 탑재하고 있다. 이 연구의 프로그램은 그래픽 환경을 접목시킨 여러 다양한 기능을 통해 콘크리트 구조부재의 모델링 및 스트럿-타이 모델 해석 및 설계 시 뛰어난 효율성과 편의성을 제공할 것이다.