• Title/Summary/Keyword: Finish line

Search Result 68, Processing Time 0.025 seconds

MARGINAL ADAPTATION OF THE CONICAL INNER CROWN FABRICATED WITH CAD/CAM (CAD/CAM으로 제작한 코누스내관의 변연적합)

  • Kim In-Sup;Kang Dong-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.40 no.1
    • /
    • pp.30-41
    • /
    • 2002
  • This study was to evaluate the fabrication method and marginal adaptation of the conical inner crown fabricated with CAD/CAM. The informations on abutment teeth were transferred to a computer with a micro contact digitizer, which had a $50{\mu}m$ accuracy on the master die. A conical inner crown was designed on a computer and a real crown was machined based on this design using CAM. The marginal fit of a computer-machined conical inner crown was assessed using electron microscopy Measurement of the marginal gap between the conical inner crown and the abutment was performed on four different locations (mesial, distal, buccal, and lingual surfaces) of the finish line. The evaluation was based on 10 test specimens. The results were as follow. 1 The mean marginal gap between the conical inner crown and abutment tooth was $83.2{\pm}43{\mu}m$, 28.9% of the specimen showed marginal gap over $100{\mu}m$. 2. The fabrication method using CATRS and CAM provided clinically acceptable marginal fitness compared to conventional casting method (P<0.05).

Kinematic analysis of professional golfers hip joint motion on the horizontal plane during driver swinging (골프 드라이브스윙 시 힙의 수평면상 움직임에 관한 운동학적 분석)

  • Park, Young-Hoon;Youm, Chang-Hong;Seo, Kook-Woong
    • Korean Journal of Applied Biomechanics
    • /
    • v.15 no.4
    • /
    • pp.97-104
    • /
    • 2005
  • Previous studies of kinematic analysis of golf swing usually dealt with variations vertically. The purpose of the study was to examine the horizontal hip joints motion of the fifteen male professional golfers during driver swinging. Kinematic variables were calculated by the Kwon3D motion analysis program. Paired t-tests and one-way ANOVA were used to compare the hip height, distance, displacement, and position differences. Results showed that there were no hip height changes and no hip height differences between left and right hip from address to impact. The axis of the backswing was braced right hip, the axis of the downswing was moving left hip. Hips position at the top of the backswing showed that hips move to target prior to hands, which means the sequential motion of the chain linked body segments. From address to impact, left hip moving distance was longer than right hip(p<.001), but during the whole swing, right hip moving distance was longer than left hip(p<.001). Hip rotation angle to target line was $-48.14{\pm}9.32^{\circ}$ at top of the backswing, $40.88{\pm}8.44^{\circ}$ at impact, and $104.70{\pm}8.14^{\circ}$ at finish.

Performance Analysis of Men's 110-m Hurdles using Rhythmic Units

  • Hong, Sung Hong;Ryu, Jae Kyun
    • Korean Journal of Applied Biomechanics
    • /
    • v.28 no.2
    • /
    • pp.79-85
    • /
    • 2018
  • Objective: This study aimed to create a strategic training method to enhance optimal athletic ability using information from 1H to 10H rhythmic units. Method: Top three world class athletes and three national winners of 110-m hurdle finals from the 2010 Daegu International Athletics Competition and 2017 National Athletics Championship, respectively, were selected. To analyze the kinematic variables, Dartfish 9.0 was used for two-dimensional analysis. Results: Regarding the interval time from the start to the finish line, the national athletes took less time during the pure acceleration phase (start to 1H) than the foreign athletes. The horizontal velocity increase was slower after 1H; the national athletes showed a lack of ability to accelerate at the interval phases. Moreover, the hurdle clearance time between phases was longer in the national athletes than in the foreign athletes and lacked consistency. Conclusion: The national athletes lacked the ability to accelerate at the transition, maximum rhythm, rhythm maintenance, and re-acceleration phases and showed a longer hurdle clearance time. If technical improvements and strategic training methods using rhythmic units are applied for hurdling motions, the national athlete's hurdling abilities, performance, and consistency could improve.

APPLICATIONS OF A MODEL TO COMPARE AFLAME SPREAD AND BEAT RELEASE PROPERTIES OF INFERIOR FINISH MATERIALS IN A COMPARTMENT

  • Kim, Woon-Hyung;James G. Quintiere
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1997.11a
    • /
    • pp.193-200
    • /
    • 1997
  • Flame spread and heat release properties and incident heat flux of interior materials subject to an igniter heat flux in a compartment are investigated and compared by using computer model. A comer fire ignition source is maintained for 10 minutes at 100 kw and subsequently increased to 300kw. In executing the model, base-line material properties are selected and one is changed for each run. Also 4 different igniter heat flux conditions and examined. Results are compared for the 12 different materials tested by the ISO Room Comer Test (9705). The time for total energy release rate to reach 1MW is examined. The parameters considered include flame heat flux and thermal inertia, lateral flame spread parameter, heat of combustion and effective heat of gasfication. The model can show the importance of each property in causing fire growth on interior Hnish materials in a compartment. The effect of ignitor heat flux and material property effects were demonstrated by using dimensionless parameters a, b and Tb. Results show that for b greater than about zero, flashover time in the ISO Room-Corner test is principally proportional to ignition time and nothing more.

  • PDF

A Study on the Determinants of Adaptation of Service Personnel in the Entrance Region (접적지역 복무 병사의 적응도 결정요인에 대한 연구)

  • Park, Sang-Hyuk;Yoon, Yeo-Yeon
    • The Journal of the Convergence on Culture Technology
    • /
    • v.5 no.3
    • /
    • pp.191-195
    • /
    • 2019
  • South Korea is in a dangerous situation where a war between the two Koreas could be triggered at any time based on the MDL (Military Demarcation Line) between the two Koreas due to the inter-Korean standoff over the armistice. Also, unlike the borders of other countries, the border between the two Koreas is the front-line area where people can feel the threat of life that could be triggered by war. Soldiers who work in special areas such as the contact area are not easily accessible due to local conditions, and are less likely to go out, stay out, stay out, or visit, and the working environment is overloaded with vast forests and silence at night, and feel anxious, lonely and insecure because they don't know when any situation will occur near the enemy. Therefore, a great deal of help will be needed to pay attention to soldiers who give up their lives here and perform their national defense duties, and to finish their barracks life safely and faithfully, and support for psychological adaptation of service members in the border areas.

Estimation of Genetic Parameters for Finished and Furlong Times in Thoroughbred Racehorses

  • Cho, Byung-Wook;Ha, Tae-Yong;Cho, Kwang-Hyun;Kim, Si-Dong;Lee, Hak-Kyo;Kong, Hong-Sik;Park, Kyung-Do
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.22 no.12
    • /
    • pp.1609-1613
    • /
    • 2009
  • The objective of this study was to estimate genetic parameters for racing performance traits of thoroughbredracehorses, using a total of 58,124 racing records of 4,200 horses at Gwacheon Racing Park collected from January 2002 to December 2006. This study measured start one furlong time, last three and last one furlong times, and the resulting furlong time averages were 14.2 seconds, 39.9 seconds and 13.9 seconds, respectively. Furlong time means a split time measured based on a 1/8-mile (or approximately 201 m) distance and finished time means total racing time measured from start position to finish line. In the shortest distance races of 1,000 m, the average last three and last one furlong time was fastest at 38.7 seconds and 13.6 seconds, respectively. The correlation between finished time and start one furlong time decreased as the race distance increased, and the same trend was recognized from the correlation between finished time and last three furlong time. In short distance races of 1,400 m or less, the starting ability was found to be an important trait. The average speed was highest at 56 km/h for a 1,000 m race and lowest at 53.2 km/h for a 1,700 m race. Heritabilities of the start one furlong time, the last three and last one furlong time were estimated to be 0.337, 0.245 and 0.210, respectively; and repeatabilities for them were 0.452, 0.353 and 0.309, respectively. Phenotypic and genetic correlations between the start and the last one furlong time were negative at -0.141 and -0.155, respectively.

A STUDY ON THE MARGINAL FIDELITIES AND FRACTURE STRENGTH OF IPS EMPRESS $2^(R)$ CERAMIC CROWNS (IPS Empress $2^(R)$를 이용한 전부도재관의 변연적합성과 파절강도에 관한 연구)

  • Yu, Ji-Hyoung;Kim, Yong-Cheol;Kang, Dong-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.5
    • /
    • pp.606-617
    • /
    • 2000
  • The purpose of this study was to measure the marginal fidelities and the fracture strength of IPS Empress $2^{(R)}\;and\;In-Ceram^{(R)}$ ceramic crowns. After constructed of 12 experimental dies for each group, ceramic crowns were fabricated on the metal master dies prepared on the maxillary right premolar Marginal gaps were measured on the specimen between the margin of each crown and finish-ing line of the metal master die by using stereo-microscope($SZ-ST^{(R)}$ Olympus, Japan) and all specimens were cemented on the metal master die with Bistite $II^{(R)}$ (Tokuyama soda Co, LTD., Japan) resin cement. Finally marginal gaps were measured again. To measure of the fracture strength, buccal incline on the functional cusp of specimens were loaded until the catastrophic failure occurred by using the AGS-1000 $D^{(R)}$(Shimadzu, Japan). The result of marginal fidelities and fracture strength were statistically analyzed with the SPSS version 8.0 programs. The results of this study were as follows : 1. No significant difference was found in the mean marginal fidelities and fracture strength between the IPS Empress $2^{(R)}\;and\;In-Ceram^{(R)}$. 2. In comparison of marginal fidelities between before and after cementation, there was significant difference(P<0.05). The IPS Empress 2 system was shown in this study that had good marginal fidelities and fracture strength compared to In-Ceram ceramics. Although this system was acceptable to clinical applications, the system still has to be considered long-term researches about marginal fidelities and fracture strength due to the lack of data about the clinical researches.

  • PDF

The effect of ultrasonic vibration on bond strength of cemented crown according to margin types and cements (초음파 진동이 주조금관의 변연형태와 시멘트의 결합강도에 미치는 영향)

  • Lee, Yun-Kyung;Bang, Mong-Sook;Park, Ha-Ok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.18 no.3
    • /
    • pp.225-233
    • /
    • 2002
  • This study was aimed to evaluate the effects of ultrasonic vibration on margin types and cements by comparing bond strength of cemented crown. In this study, margins of each metal die, which were chamfer, shoulder and shoulder with bevel, were prepared using computer milling machine. Specimens were cemented with zinc phosphate cement or resin cement. The specimens were divided by the finish line and cement used, ultrasonic vibration. I made total 84 specimens. All specimens were divided into two groups. One group was not vibrated, the other group was subjected to ultrasonic vibration for 12 minutes. Tensile bond strength was measured using Universial testing machine. The changes of bond strength in groups were statistically analyzed by t-test or One-way ANOVA. The results were as follows : 1. Ultrasonic instrumentation diminished the bond strength of crown cemented with zinc phosphate cement and resin cement after 12 minutes application. 2. In case of zinc phosphate cement, the bond strength of a vibrated group was showed significantly decreased(p<0.05). In vibrated groups with zinc phosphate cement, shoulder with bevel exhibit a significant difference to chamfer and shoulder(p<0.05) 3. Resin cement was more resistant to ultrasonic vibration than zinc phosphate cement and showed no significant differences according to ultrasonic vibration and margin type. In conclusion, These results revealed that zinc phosphate cement was most affected and resin cement was the least affected by ultrasonic vibration. Especially shoulder with bevel design was most affected in zinc phosphate cement groups. we should consider these results and be taken in the application of ultrasonic vibration to any teeth restored with crowns.

Effect of GLUMA desensitizer on the retention of full metal crowns cemented with Rely X U200 self-adhesive cement

  • Lawaf, Shirin;Jalalian, Ezatallah;Roshan, Roshanak;Azizi, Arash
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.5
    • /
    • pp.404-410
    • /
    • 2016
  • PURPOSE. Considering the importance of retention in the success and long-term clinical service of fixed partial dentures (FPDs) as well as the existing controversy regarding the effect of GLUMA desensitizer on the retention of full metal crowns cemented with RelyX U200 self-adhesive cement, this study aimed to assess the effect of GLUMA desensitizer on the retention of full metal crowns cemented using RelyX U200. MATERIALS AND METHODS. In this experimental study, 20 sound human premolars were prepared; a 0.5 mm chamfer finish line was prepared above the cementoenamel junction. The teeth were randomly assigned to two groups: a desensitizer group (n = 10, treated with GLUMA desensitizer) and a control (n = 10, no surface treatment). Full metal crowns were fabricated of base metal alloy and had a ring. All crowns were cemented with RelyX U200 and subjected to retention test by using a universal testing machine. The data were analyzed using SPSS version 20 and independent t-test. RESULTS. The mean tensile bond strength was significantly higher in the GLUMA desensitizer group ($230.63{\pm}63.8N$) compared to the control group ($164.45{\pm}39.3N$) ($P{\leq}.012$). CONCLUSION. GLUMA desensitizer increases the tensile bond strength of RelyX U200 self-adhesive cement to dentin.

THE EFFECT OF VARIOUS FINISH LINE PREPARATIONS ON THE MARGINAL SEAL OF FULL CROWN PREPARATIONS (전부주조금관 치경부 변연의 형태가 치경부 변연적합에 미치는 영향)

  • Kim, Soon Young;Lee, Seok Hyeon;Jo, Kwang Hun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.28 no.2
    • /
    • pp.165-174
    • /
    • 1990
  • The purpose of the study was to correlate margin design(chamfer, shoulder, shoulder with a $45^{\circ}$ bevel. with the seating and sealing of cemented full cast crowns under standardized simulated clinical conditions. Wax patterns were made with milled stainless-steel dies and rings, and were invested, burnt out, and cast. The full cast crowns were comented on individual resin dies, and a gradually diminishing load(45kg to 25kg. was applied over a 10-minute period. The specimens were sectioned centrally with a low speed diamond saw and examined with light microscope. The results were as follows : 1. Chamfer preparations demonstrated it was the best marginal seal, followed in order by the shoulder with a $45^{\circ}$ bevel, and by the shoulder(p<.05). 2. Chamfer preparations demonstrated it was the best occlusal seating, followed in order by the shoulder, and by the shoulder with a $45^{\circ}$ bevel(p<.05).

  • PDF