• Title/Summary/Keyword: Finger Pressure

Search Result 138, Processing Time 0.023 seconds

Evaluation of the Pressure of the Tongue, Lips, and Cheeks in Patients with Myofunctional Therapy and Appliance (근 기능 훈련 및 장치 치료를 시행한 환자들의 혀, 입술, 볼의 최대 압력 비교)

  • Minah Sung;Myeongkwan Jih;Nanyoung Lee
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.50 no.1
    • /
    • pp.13-23
    • /
    • 2023
  • The purpose of this study was to compare the values of tongue pressure (TP), lip closing pressure (LCP), right buccal pressure (RBP), and left buccal pressure (LBP) and check the intraoral muscle imbalance and observe the changed values according to the myofunctional therapy (MFT) period. The MFT with a prefabricated appliance was performed on patients with certain muscular dysfunctions due to oral habits. And the improvement of perioral muscles was evaluated using a balloon-based pressure measurement. The group consisted of 21 patients with oral habits such as chronic mouth breathing, finger sucking, lip sucking, tongue thrusting, and atypical swallowing habits. When comparing the two groups before treatment, there was a significant difference in TP and LCP values. The TP increased the most in the first month since the start of myofunctional therapy, and the LCP increased the most between 3 and 6 months after treatment began. The values of TP, LCP, RBP, and LBP in the control group measured before treatment were very similar to the results of the experimental group 6 months after the myofunctional therapy. When the MFT was steadily performed, it was possible to observe a noticeable increase in the tongue and lip closing pressure. At least 6 months of myofunctional therapy is recommended for patients with intraoral muscle imbalance due to oral habits.

Study on the manufacturing of high-frequency heating Japanese cedar laminated board by finger jointing method (1) - Gluing characteristics of Japnese cedar board by PVAc emulsion adhesives - (핑거접합방식에 의한 삼나무의 고주파가열 집성판 제조에 관한 연구 (1) - 삼나무 판재의 초산비닐수지 접착특성 -)

  • So Won-Tek;Chai Jyung-Ki
    • Journal of the Korea Furniture Society
    • /
    • v.16 no.1
    • /
    • pp.1-8
    • /
    • 2005
  • This experiment was carried out to investigate the gluing characteristics of poly vinyl acetate emulsion adhesive(PVAc) on the Cryptomeria japonica laminated boards. This sample trees are major planting species and have been planted in southern district for a long time. The optimum gluing conditions for laminated board were summarized as follows; the amount of spreading glue, assembly time, clamping pressure, and clamping time for PVAc resin were $200g/m^2$, 10min., $5kg/cm^2$, and 6hrs., respectively, and the relative formulae between extension ratio(x) and block shear strength(y) was $y=-9.6x+85.2(R^2=0.95)$.

  • PDF

The flow of $CO_{2}$ and $N_{2}$ gases through Asymmetric polytherimide Membrane

  • Park, You-In;Lee, Kew-Ho
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1995.09a
    • /
    • pp.73-85
    • /
    • 1995
  • The asymmetric hollow fiber membranes were prepared by the wet spining of polyetherimide dope solution and the effect of hollow fiber structures on the permeation characteristics of carbon dioxide and nitrogen gases through these membrane were investigated. As the concentration of the $\gamma$-butyrolactone (GBL) in dope solution, acting as a swelling agent was increased, the structure of hollow fiber was changed from the finger to sponge type. The permeabilities of gases (CO$_{2}$, N$_{2}$) through these membrane were measured over the wide range of pressure under different temperature. The effect of water vapor on the permeabilities of gases was also investigated. The measured permeabilities showed the different characteristics depending on the structure of membranes. It was found that the flow through the pores were dominant over the polymers matrix. Blocking effect by water vapor in the pores of skin layer greatly improved the ideal separation factor of carbon dioxide/nitrogen.

  • PDF

A CASE REPORT OF SIALOLITHIASIS IN WHARTON'S DUCT (Wharton씨 도관내에 발생한 타석증에 관한 증례보고)

  • Lee, Kyung-Ok;Kim, Dae-Eop;Lee, Kwang-Hee
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.24 no.3
    • /
    • pp.603-609
    • /
    • 1997
  • Sialolithiasis is the formation of calcific concretions within the ductal system of major or minor salivary glands. The exact nature of sialolith evolution is not known. It may occur at any age but, it is most common in middle-aged adult and rare in childhood. In this paper, a case of sialolithiasis just beneath the mucosa in the anterior portion of the Wharton's duct observed in a 5-year old boy. It was approximately $2.5{\times}5$ mm in size and has no clinical symptoms. Under local anesthesia, it was removed by dilatation of orifice of the duct and pressure on the floor of oral cavity by finger.

  • PDF

DULEX, A Wearable Hand Rehabilitation Device for Stroke Survivals (뇌졸중 환자를 위한 착용형 손 재활훈련기기, DULEX)

  • Kim, Young-Min;Moon, In-Hyuk
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.16 no.10
    • /
    • pp.919-926
    • /
    • 2010
  • This paper proposes a wearable hand rehabilitation device, DULEX, for persons with functional paralysis of upper-limbs after stoke. DULEX has three degrees of freedom for rehabilitation exercises for wrist and fingers except the thumb. The main function of DULEX is to extend the range of motions of finger and wrist being contracture. DULEX is designed by using a parallel mechanism, and its parameters such as length and location of links are determined by kinematic analysis. The motion trajectory of the designed DULEX is aligned to human hand to prevent a slip. To reduce total weight of DULEX, artificial air muscles are used for actuating each joint motion. In feedback control, each joint angle is indirectly estimated from the relations of the input air pressure and the output muscle length. Experimental results show that DULEX is feasible in hand rehabilitation for stroke survivals.

Tuning of a Laterally Driven Microresonator using Electrostatic Comb Step Array (계단식 정전빗살구조물을 이용한 수평구동형 미소공진기의 주파수 조정)

  • Lee, Ki-Bang;Seo, Young-Ho;Cho, Young-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.8
    • /
    • pp.1259-1265
    • /
    • 2003
  • We present a new post-fabrication frequency tuning method for laterally driven electrostatic microresonators using a DC-biased electrostatic comb array of linearly varied finger-length. The electrostatic tuning force and the equivalent stiffness, adjusted by the DC-biased tuning-comb array, have been formulated as functions of geometry and DC tuning voltage. A set of frequency-turnable microresonators has been designed and fabricated by 4-mask surface-micromachining process. The resonant frequency of the microfabricated microresonator has been measured for a varying tuning voltage at the reduced pressure of 1 torr. The maximum 3.3% reduction of the resonant frequency is achieved at the tuning voltage increase of 20V.

Development of ECS-NIBP-$SpO_2$ Patient Monitoring System (ECG-NIBP-$SpO_2$ 환자감시장치 개발)

  • Kim, N.H.;Shin, W.H.;Lee, G.K.;Ra, S.W.;Kim, G.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.129-130
    • /
    • 1998
  • In this paper, We designed the ECG-NIBP-$SpO_2$ patient monitor. This production can measure Electrocardiograph, Heart Rate, Noninvasive Blood Pressure, and Oxygen Saturation for Noninvasive Mehod and can display each information. These informations were implemented by the electrodes of ECG part, the cuff of NIBP module and the finger probe with light sensor of $SpO_2$ without injection of needle or catheter. In addition, We developed a new analysis algorithm and measurement technique for NIBP and $SpO_2$ to observe patient's conditions correctly.

  • PDF

Noble Development of Array Type Gripper for Robot Arm

  • Lee, Jaeman;Lee, Wangheon
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.2_1
    • /
    • pp.185-193
    • /
    • 2022
  • For grippers of industrial robots, parallel grippers and multi-function finger grippers are used. The former has the advantage of low cost but has the disadvantage of low precision, and the latter has the advantage of excellent precision but has the disadvantage of being expensive. In this paper, we developed a grip that can detects the various shapes of the object to be gripped on the gripper surface by using mesured pressure information frome Veloset Sheet sensor so that the gripper can be gripped without deforming the surface of the gripper. Also we did not only developed the array type gripper and 4 array type grippers (ATG), but also confirmed the usefulness of array type gripper developed in this study according to the 4 predefined evaluation criteria

A Systemic Review of Pulse Contour Analysis and Fourier Spectrum Analysis on the Photoplethysmography of Digit (지첨용적맥파의 파형분석과 주파수분석에 대한 문헌적 연구)

  • Nam, Tong-Hyun;Park, Young-Bae;Park, Young-Jae;Shin, Sang-Hoon
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.11 no.1
    • /
    • pp.48-60
    • /
    • 2007
  • Palpation of the pulse has been used in Korean traditional medicine since ancient times to assess physical health. Pulse wave contour may be obtained by measuring arterial pressure or blood volume change of skin. The latter is called as Photoplethysmography(PPG) or digital volume pulse(DVP). The PPG signal is measured by a device comprising an infrared light sourece and a photodetector. Although less widely used, this technique deserves further consideration because of its simplicity and ease of use. The contour of the PPG is formed as a result of a complex interaction between the left ventricle and the systemic circulation. It usually exhibits an early systolic peak and an early diastolic peak. the first peak is formed mainly by pressure trasmitted along a direct path from the left ventricle to the finger. The second peak is formed in part by pressure transmitted along the aorta and large arteries to sites of impedance mismatch in the lower body. The contour of the PPG is sensitive to changes in arterial tone and is influenced by ageing and large artery stiffness. Measurements taken directly from the PPG or from its second derivative can be used to assess these properties. In some mathematical approaches, the extraction of periodic components using frequency analysis was tried to analysis of the PPG. But we don't understand yet what kind of factor in the cardiovascular system or human body is related with the respective specific Fourier components of PPG. This review describes the background to measurement principles, representative contour, contour analysis and frequency domain analysis of PPG, and current and future.

  • PDF

Development of the pulse analyzing system using FBG (FBG를 이용한 맥진 시스템 개발)

  • Jeon, Young-Ju;Lee, Jeon;Ryu, Hyun-Hee;Lee, Jae-Hoon;Lee, Si-Woo;Kim, Jong-Yeol
    • Korean Journal of Oriental Medicine
    • /
    • v.13 no.3
    • /
    • pp.105-110
    • /
    • 2007
  • This work reports the pulse diagnosis system using FBG sensors which can display pulse signals detected while oriental medical doctors are conducting pulse diagnoses and simultaneously pressing the sensors by three fingers. Each optical fiber has five FBG sensing units fabricated in 2 mm width and 2 mm inter-sensor spacing. Three optical fibers with the FBG units in the parallel line configuration are then placed on each finger-pressing region and thus overall 9 fibers are used for the pulse measurements on the so-called "chon", "gwan", and "ch대k". A fixture holding the optical fiber arrays is able to adjust the height of the FBG sensing units while placing the fibers on the wrist. The pulse signals detected by the FBG sensors from chon, kwan, and chuk have been analyzed using 4 channel spectrum analyzer connected to the optical fibers. The measured pulse signals exhibit variations due to the nonuniform pressure distributions applied. resulting in the differences in the detected pulse signals between fiber lines. However. this work is the first step towards objective and quantitative analyses of the pulse diagnosis in oriental medicine which has traditionally been performed on subjective basis. Future works will be devoted to improving sensor stability, developing the way applying pressure and algorithms reporting the objective classification of the pulse status from systemic measurements using the sensors instead of relying on the clinicians' diagnoses subjectively performed. A successful pulse diagnosis system emerging in the future is expected to contribute to education as well as promoting pulse diagnosis in oriental medicine to the scientific research area.

  • PDF