• Title/Summary/Keyword: Fine Particulate Matter

Search Result 285, Processing Time 0.145 seconds

Evaluation of Ammonia Emission Coefficient according to the use of Compound Fertilizers when Cultivating Apples and Pears in Orchards (과수원에서 사과 및 배 재배 시 복합비료 시용에 따른 암모니아 배출계수 평가)

  • Kim, Min-Wook;Hong, Sung-Chang;Yu, Seon-Young;Kim, Jin-Ho
    • Korean Journal of Environmental Agriculture
    • /
    • v.40 no.4
    • /
    • pp.366-372
    • /
    • 2021
  • BACKGROUND: Ammonia is known as a precursor to fine particulate matter, and according to CAPSS, annual ammonia emissions in the agricultural sector were 249,777 tons as of 2018, accounting for about 79.0% of Korea's total ammonia emissions. In particular, ammonia emissions from agricultural land increased by 19,566 tons (10.2%) compared to the previous year. The Ministry of Environment is setting emission statistics using the ammonia emission coefficient developed in Korea in 2008, but researchers in the agricultural field regard it as a coefficient that does not reflect the reality of Korea's agricultural environment. Accordingly, in order to develop ammonia emission coefficients from the cultivation of apples and pears, Korea's representative fruit type, test agricultural land was set in Iksan, Jeollabuk-do. METHODS AND RESULTS: This study attempted to obtain the ammonia emission coefficient by the treatment of the composite fertilizer (N-P2O5-K2O=12-7-9), and the flux was measured using a dynamic flow-through chamber method. As for the chamber, a total of 12 chambers were installed repeatedly in 4 zones and used to develop emission coefficients. Using compound fertilizers during fruit tree cultivation, the ammonia emission coefficient was evaluated as 10.4 kg NH3/ton for pears and 15.3 kg NH3/ton for apples. The reason why the ammonia emission coefficient according to the use of composite fertilizers was calculated higher for apple cultivation is believed to be due to the relatively high pH concentration of apple orchard soil. CONCLUSION(S): This study may provide basic data for upgrading the ammonia emission coefficient when using composite fertilizers in agricultural land. In the future, it might be necessary to upgrade the calculation of emissions through the development of ammonia and fine particulate matter emission coefficients considering the agricultural environment of Korea.

Effect of Particulate Matter and Ash Amount on Pressure Drop and Flow Uniformity of Diesel Particulate Filter Reduction System (입자상물질과 Ash양이 디젤매연여과장치 내의 배압 및 유동균일도에 미치는 영향)

  • Kim, YunJi;Han, DanBee;Seo, TaeWon;Oh, KwangChul;Baek, YoungSoon
    • Clean Technology
    • /
    • v.26 no.1
    • /
    • pp.22-29
    • /
    • 2020
  • Recently, as the fine dust is increased and the emission regulations of diesel engines have been tightened, interest in diesel soot filtration devices has rapidly increased. There is specifically a demand for the technological development of higher diesel exhaust gas after-treatment device efficiency. As part of this, many studies were conducted to increase exhaust gas treatment efficiency by improving the flow uniformity of the exhaust gas in the diesel particulate filter (DPF) and reducing the pressure drop between the inlet and the outlet of DPF. In this study, the effects of pressure drop by the flow rate and temperature of exhaust gas, DPF I/O ratio, Ash, and PM amount in diesel reduction device were simulated via a 12" diameter DPF and diesel oxidation catalyst (DOC) using ANSYS Fluent. As the flow rate and temperature decreased, the pressure drop decreased, whereas the PM amount affected the pressure drop more than the ash amount and the pressure drop was lower in anisotropic DPF than isotropic DPF. In the case of DPF flow uniformity, it was constant regardless of the various variables of DPF. In ESC and ETC conditions, the filtration efficiency for PM was similar regardless of anisotropic and isotropic DPF, but the filtration efficiency for PN (particle number) was higher in anisotropic DPF than isotropic DPF.

Investigation of the Concentration of PM2.1 & PM10 and Alveolar Deposition Ratio (미세먼지(PM10)와 초미세먼지(PM2.1)의 농도와 폐포 침착율 조사)

  • Kim, Seong Cheon
    • Journal of Environmental Health Sciences
    • /
    • v.45 no.2
    • /
    • pp.126-133
    • /
    • 2019
  • Objectives: In this study, a nine-stage cascade impactor was used to collect dust, and the concentration of $PM_{2.1}$ & $PM_{10}$ and alveolar deposition ratio were investigated. Methods: This study was conducted at Kunsan National University from May to June 2016. A nine-stage Cascade Impactor was used to analyze the concentrations of fine and ultrafine dust and to estimate the alveolar deposition rate by particle size of atmospheric dust particles. The pore size of each stage of the collector used in this study gradually increased from F to 0, with the F-stage as the last stage. Results: The mass fraction of PM showed a bimodal distribution divided into $PM_{2.1}$ & $PM_{10}$ based on $2.1-3.1{\mu}m$. The average mass fraction of particulate matter in the range of $2.1-3.1{\mu}m$ was 44%, and the area occupied by $PM_{2.1}$ was similar. Therefore, the Gunsan area is considered to be a region where there are similar effects from anthropogenic and natural sources. Conclusion: Dust collecting efficiency increased with the stage of collecting fine dust, and the efficiency of collection was very low at the stage of collecting ultra-fine dust. The seasonal overall efficiency of the Cascade Impactor was 44% in spring and 37.4% in summer, and the average overall efficiency was 40.7%. The alveolar deposition rate of $PM_{2.1}/PM_{10}$ during the sampling period was estimated to be about 75% deposited in the alveoli.

Introducing SPARTAN Instrument System for PM Analysis (PM 관측을 위한 스파르탄 시스템)

  • Sujin Eom;Sang Seo Park;Jhoon Kim;Seoyoung Lee;Yeseul Cho;Seungjae Lee;Ehsan Parsa Javid
    • Atmosphere
    • /
    • v.33 no.3
    • /
    • pp.319-330
    • /
    • 2023
  • As the need for PM type observation increases, Surface Particulate Matter Network (SPARTAN), PM samplers analyzes aerosol samples for PM mass concentration and chemical composition, were recently installed at two sites: Yonsei University at Seoul and Ulsan Institute of Science and Technology (UNIST) at Ulsan. These SPARTAN filter samplers and nephelometers provide the PM2.5 mass concentration and chemical speciation data with aerosol type information. We introduced the overall information and installation of SPARTAN at the field site in this study. After installation and observation, both Seoul and Ulsan sites showed a similar time series pattern with the daily PM2.5 mass concentration of SPARTAN and the data of Airkorea. In particular, in the case of high concentrations of fine particles, daily average value of PM2.5 was relatively well-matched. During the Yonsei University observation period, high concentrations were displayed in the order of sulfate, black carbon (BC), ammonium, and calcium ions on most measurement days. The case in which the concentration of nitrate ions showed significant value was confirmed as the period during which the fine dust alert was issued. From the data analysis, SPARTAN data can be analyzed in conjunction with the existing urban monitoring network, and it is expected to have a synergetic effect in the research field. Additionally, the possibility of being analyzed with optical data such as AERONET is presented. In addition, the method of installing and operating SPARTAN has been described in detail, which is expected to help set the stage for the observation system in the future.

Anti-aging effect of Codium fragile extract on keratinocytes damaged by fine dust PM10 (미세먼지 PM10으로 손상을 유도한 각질형성세포에서 청각 (Codium fragile) 추출물의 항노화 효과)

  • Bo Ae Kim
    • The Korea Journal of Herbology
    • /
    • v.38 no.4
    • /
    • pp.45-52
    • /
    • 2023
  • Objectives : Fine dust caused by environmental pollution cause oxidative damage and skin aging. In this study, The possibility of using the Codium fragile extract (CFE) as an anti-aging product for skin improvement was evaluated by confirming the protective effect of skin cells from PM10 (particulate matter 10) through inhibition of ROS and MMPs. Methods : In this study, elastase and collagenase inhibitory activities were evaluated. Cell viability was evaluated by treating keratinocytes (HaCaT cell line) with CFE at various concentrations. The cytoprotective effect from PM10 in keratinocyteswas evaluated using the 3-[4,5-dimethylthiazol]-2-yl]-2,5-diphenyl-tetrazoliumbromide (MTT) assay. ROS (reactive oxygen species) was measured in keratinocytes damaged by PM10 using DCF-DA (2′,7′-dichlorofluorescin diacetate) fluorescence staining. As an anti-aging effect of CFE, MMP-1 (matrix metalloproteinase-1) and MMP-1 (matrix metalloproteinase-9) inhibitory activities were evaluated. Results : As a result, CFE decreased the activity of elastase and collagenase. As a result of evaluating the toxicity of CFE, it is non-toxic at a concentration of 10 to 80 ㎍/㎖. Although cell viability of HaCaT cells treated with PM10 decreased, cell viability increased by 38% when treated with CFE 80 ㎍/㎖. Also, ROS decreased by 8.4%, and MMP-1 and MMP-9 decreased at CFE 80 ㎍/㎖. Conclusions : CFE showed excellent cell protection effect, and it is considered that it can be used in anti-aging products for skin improvement by effectively inhibiting ROS and MMPs from keratinocyte damage caused by fine dust.

The Size-Oriented Particulate Mass Ratios and Their Characteristics on the Seoul Metropolitan Subway Lines

  • Lee, Eun-Sun;Lee, Tae-Jung;Park, Min-Bin;Park, Duckshin;Kim, Shin-Do;Kim, Dong-Sool
    • Asian Journal of Atmospheric Environment
    • /
    • v.10 no.4
    • /
    • pp.217-225
    • /
    • 2016
  • The purpose of the study was to initially investigate the concentration patterns of $PM_1$, $PM_{2.5}$ and $PM_{10}$ in the Seoul subway lines, and then to figure out the PM behaviors of internal and external sources inside subway tunnels. The PMs were monitored by a light scattering real-time monitor during winter (Jan. 8-26 in 2015) and summer (July 2-Aug. 7 in 2015) in tunnel air, in passenger cabin air, and in the ambient air. The daily average $PM_{10}$, $PM_{2.5}$, and $PM_1$ concentrations on these object lines were $101.3{\pm}38.4$, $81.5{\pm}30.2$, and $59.7{\pm}19.9{\mu}g/m^3$, respectively. On an average, the PM concentration was about 1.2 times higher in winter than in summer and about 1.5 times higher in underground tunnel sections than in ground sections. In this study, we also calculated extensively the average PM mass ratios for $PM_{2.5}/PM_{10}$, $PM_1/PM_{10}$, and $PM_1/PM_{2.5}$; for example, the range of $PM_{2.5}/PM_{10}$ ratio in tunnel air was 0.82-0.86 in underground tunnel air, while that was 0.48-0.68 in outdoor ground air. The ratio was much higher in tunnel air than in outdoor air and was always higher in summer than in winter in case of outdoor air. It seemed from the results that the in/out air quality as well as a proper amount of subway ventilation must be significant influence factors in terms of fine PM management and control for the tunnel air quality improvement.

The Study on Changes of Exhaust Efficiency and Fine Particle Concentration at a Ventilation Opening by a Air Curtain Flow in a Subway Model Tunnel (지하철 모사터널에서 에어커튼을 이용한 환기구의 배기효율 및 미세입자 농도 변화 연구)

  • Han, Bang-Woo;Kim, Hak-Joon;Kim, Yong-Jin;Jeong, Sang-Hyeon;Kim, Yong-Min;Kim, Jong-Ryul
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.27 no.5
    • /
    • pp.614-622
    • /
    • 2011
  • In this study, a new tunnel ventilation method with a high velocity air curtain flow has been investigated for improving the ventilation exhaust efficiency and removing air pollutants in subway tunnels. At upper or lower position right downstream of a main duct connected with a ventilation opening, air curtain flows were suppled into the main duct where the air flow velocity was in the range of 2~6 m/s. Exhaust efficiency was monitored for both cases with and without air curtain flow for different air velocities, locations and injection angles of the air curtain. Particulate matter concentrations (PM10, PM2.5 and PM1.0) were also checked at both the main duct and ventilation opening before and after supplying air curtain flows. Lower air velocity of the main duct flow, higher air velocity of the air curtain led to higher exhaust efficiency and the air curtain condition of 30..inclined injection toward the main flow showed the maximum exhaust efficiency. The exhaust efficiency of about 24% without the air curtain could be improved to about 34% after using the air curtain flow. PM concentration decreased at the main duct and increased at the ventilation opening after using the air curtain flow. Therefore, the suggested method to use air curtain flows in tunnels will be probably one of the promising tools to reduce air pollutants in subway tunnels.

A Study on the Metallic and Ion Elements by Fine Particle and Effects of Vessels Exhaust Emission in Busan City (부산지역의 미세먼지 중 중금속 및 이온성분과 선박배출가스의 영향에 관한 연구)

  • Lee, Seung-Won;Son, Yi-Seul;Kim, Jung-Kwon
    • Journal of Environmental Science International
    • /
    • v.20 no.1
    • /
    • pp.147-153
    • /
    • 2011
  • The objectives of this study were to investigate the seasonal characteristics of metallic and ion elements of $PM_{10}$(Particulate matter with aerodynamic diameter ${\leq}10\;{\mu}m$) and the effects of vessels exhaust emission from ships harboring in Busan City. The $PM_{10}$ samples were collected from January 2010 to October 2010 at Dongsam-dong(coastal area), in Busan City. The particulate matters were analyzed for major water soluble ionic components and metals. The ranges of the $PM_{10}$ mass concentrations were from 29.8 ${\mu}g/m^3$ to 47.0 ${\mu}g/m^3$ in Dongsam-dong. The $PM_{10}$ mass concentrations in Dongsam-dong are very similar to Gwangbok-dong during same sampling periods. These results were understood by the effects of the shipping source emitted from ships anchoraging and running. The concentrations of water-soluble ions and metals in the $PM_{10}$ had a level of as high as the order of $SO_4^{2-}$>$NO_3^-$>$Cl^-$ and $NH_4^+$>$Na^+$>$Ca^{2+}$>$K^+$>$Mg^{2+}$, respectively. The correlation coefficients($R^2$) for $SO_4^{2-}/PM_{10}$ and $NH_4^+/PM_{10}$ of were 0.7446 and 0.7784, respectively, and it showed the high correlation with each other.

Contingent Valuation Survey on Changes in Citizens' Perception on Atmospheric Pollution in Seoul, Korea (조건부 가치 설문조사를 통한 대기 오염에 대한 서울 시민의 인식 변화 조사)

  • Hong, Je-Woo;Hong, Jinkyu;Kim, Junghwan
    • Atmosphere
    • /
    • v.29 no.2
    • /
    • pp.213-218
    • /
    • 2019
  • A valuation of air pollution is critical for relevant policy-making for the public and research direction. This study conducted a willingness-to-pay (WTP) survey using contingent valuation method (CVM) in Seoul Korea. In detail, this study puts an emphasis on its temporal changes referred on two surveys conducted in 2014 and 2019. In reference to the previous studies in 2002, our survey indicated that the public awareness of air pollution and interests on its sources and solutions increased noticeably. Our survey showed that WTP increased significantly from 2588 to 4827 and 8240 Korean Won $month^{-1}$ in 2002, 2014, and 2019, respectively. Moreover, the percentage of respondents to pay the WTP also increased from 48% to 68% and 79% in 2002, 2014, and 2019, respectively. Our analysis based on the number of Google search on particulate matters (PMs) strongly suggests that such the noticeable increases of the public attention to air pollution is well accorded with the moment of the announcement of a standard for ultra-fine particles and the start of PM prediction in late 2013. But the Google search rate grew about 16.7 times in 2009 compared to 2014, which is much larger than the growth rate of interest and WTP between 2014 and 2019. Our results shed light on policy decision for the right person in the right place on the right time in the era of air pollution.

A Study on the Characteristics of Condensable Fine Particles in Flue Gas (배출가스 중 응축성미세먼지 특성 연구)

  • Gong, Buju;Kim, Jonghyeon;Kim, Hyeri;Lee, Sangbo;Kim, Hyungchun;Jo, Jeonghwa;Kim, Jeonghun;Gang, Daeil;Park, Jeong Min;Hong, Jihyung
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.32 no.5
    • /
    • pp.501-512
    • /
    • 2016
  • The study evaluated methods to measure condensable fine particles in flue gases and measured particulate matter by fuel and material to get precise concentrations and quantities. As a result of the method evaluation, it is required to improve test methods for measuring Condensable Particulate Matter (CPM) emitted after the conventional Filterable Particulate Matter (FPM) measurement process. Relative Standard Deviation (RSD) based on the evaluated analysis process showed that RSD percentages of FPM and CPM were around 27.0~139.5%. As errors in the process of CPM measurement and analysis can be caused while separating and dehydrating organic and inorganic materials from condensed liquid samples, transporting samples, and titrating ammonium hydroxide in the sample, it is required to comply with the exact test procedures. As for characteristics of FPM and CPM concentrations, CPM had about 1.6~63 times higher concentrations than FPM, and CPM caused huge increase in PM mass concentrations. Also, emission concentrations and quantities varied according to the characteristics of each fuel, the size of emitting facilities, operational conditions of emitters, etc. PM in the flue gases mostly consisted of CPM (61~99%), and the result of organic/inorganic component analysis revealed that organic dusts accounted for 30~88%. High-efficiency prevention facilities also had high concentrations of CPM due to large amounts of $NO_x$, and the more fuels, the more inorganic dusts. As a result of comparison between emission coefficients by fuel and the EPA AP-42, FPM had lower result values compared to that in the US materials, and CPM had higher values than FPM. For the emission coefficients of the total PM (FPM+CPM) by industry, that of thermal power stations (bituminous coal) was 71.64 g/ton, and cement manufacturing facility (blended fuels) 18.90 g/ton. In order to estimate emission quantities and coefficients proper to the circumstances of air pollutant-emitting facilities in Korea, measurement data need to be calculated in stages by facility condition according to the CPM measurement method in the study. About 80% of PM in flue gases are CPM, and a half of which are organic dusts that are mostly unknown yet. For effective management and control of PM in flue gases, it is necessary to identify the current conditions through quantitative and qualitative analysis of harmful organic substances, and have more interest in and conduct studies on unknown materials' measurements and behaviors.