• 제목/요약/키워드: Fin Performance

검색결과 572건 처리시간 0.025초

톱니형휜이 부착된 2중 열교환관을 이용한 엔진 배열회수기에 관한 실험적 연구 (An Experimental Study on the Heat Exchanger for the Engine Waste Heat Recovery Using Serrated Fins and Bayonet Tube)

  • 양태진;김종수;임용빈
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제29권6호
    • /
    • pp.685-691
    • /
    • 2005
  • In this study, high performance waste heat recovery heat exchanger was developed using the bayonet tube with spiral serrated fins. Especially, heat exchanger of the bayonet tube type was operated well because of double water passes mechanism and characteristics. A cooling water Passes down inner tubes to thimble-form tubes, then flows back up as it boils. The heat exchanger of bayonet tube type was composed of steel tube with 7channels$(I.D_1\;14mm.\;I.D_2\;31.6mm)$ and spiral serrated fins. The performance tests were conducted under the following conditions A cooling water flow rate was 273kg/h and engine l·pm was varied from 750rpm to 3500 rpm. From the experimental result. waste heat recovery was 9.21kW when engine rpm was 3500. and pressure drop was $15\~260mmHg/m^3$ The effectiveness of heat exchanger was about /$0.7\~0.9$. The performance of heat exchanger was evaluated by using the $\varepsilon-NTU$ method. In the study the NTU of the heat exchanger was $1.57\~2.33$.

핀테크 기반 주식투자 최적화 모델 구축 사례 연구 : 기관투자자 대상 (A Case Study on the Establishment of an Equity Investment Optimization Model based on FinTech: For Institutional Investors)

  • 김홍곤;김소담;김희웅
    • 지식경영연구
    • /
    • 제19권1호
    • /
    • pp.97-118
    • /
    • 2018
  • The finance-investment industry is currently focusing on research related to artificial intelligence and big data, moving beyond conventional theories of financial engineering. However, the case of equity optimization portfolio by using an artificial intelligence, big data, and its performance is rarely realized in practice. Thus, the purpose of this study is to propose process improvements in equity selection, information analysis, and portfolio composition, and lastly an improvement in portfolio returns, with the case of an equity optimization model based on quantitative research by an artificial intelligence. This paper is an empirical study of the portfolio based on an artificial intelligence technology of "D" asset management, which is the largest domestic active-quant-fiduciary management in accordance with the purpose of this paper. This study will apply artificial intelligence to finance, analyzing financial and demand-supply information and automating factor-selection and weight of equity through machine learning based on the artificial neural network. Also, the learning the process for the composition of portfolio optimization and its performance by applying genetic algorithms to models will be documented. This study posits a model that the asset management industry can achieve, with continuous and stable excess performance, low costs and high efficiency in the process of investment.

An estimation method of full scale performance for pulling type podded propellers

  • Park, Hyoung-Gil;Choi, Jung-Kyu;Kim, Hyoung-Tae
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제6권4호
    • /
    • pp.965-980
    • /
    • 2014
  • This paper presents a new estimation method of full scale propulsive performance for the pulling type podded propeller. In order to estimate the drag of pod housing, a drag velocity ratio, which includes the effects of podded propeller loading and Reynolds number, is presented and evaluated through the comparison of model test and numerical analysis. By separating the thrust of propeller blade and the drag of pod housing, extrapolation method of pod housing drag to full scale is deduced, and correction method of propeller blade thrust and torque to full scale is presented. This study utilized the drag coefficient ratio of the pod housing as a measure for expanding it to full scale, but in order to increase the accuracy of performance evaluation, additional study is necessary on the method for the full scale expansion via separating the drag of pod body, strut and fin which consist the pod housing.

전자교환시스템 냉각을 위한 히트파이프 적용 연구 (A study on the application of heat pipe to the cooling of ATM switching system)

  • 김원태;이윤표;윤성영
    • 설비공학논문집
    • /
    • 제9권4호
    • /
    • pp.497-503
    • /
    • 1997
  • In the present study, the cooling package using the heat pipe has been developed to improve the thermal performance in the point of cooling characteristics of the electronic chip placed to the subrack being readily assembled and disassembled in ATM switching system. As the preliminary experiments, the cooling performances between a conventional way using a cooling fin and a proposed method applying the heat pipe are compared and analyzed. The cooling performance at a simulated electronic component packaging a heat pipe module is approximately achieved up to $5.0W/cm^2$ heat flux and the allowable temperature at the heated chip is sustained in the range within $70^{\circ}C$. From the results, it is confirmed that temperature oscillations are also settled by inserted wick in the evaporator section. From the user's viewpoint, the method to assemble and disassemble the heat pipe easily has been devised.

  • PDF

흡수식 냉온수기 증발기용 전열관의 전열성능에 관한 연구 (A-Study on The Heat Transfer Performance of Evaporator Heat Transfer Tube for Absorption Chiller)

  • 권오경;차동안;윤재호;김효상
    • 설비공학논문집
    • /
    • 제21권4호
    • /
    • pp.215-221
    • /
    • 2009
  • The objectives of this paper are to measure the heat transfer and pressure drop of the heat transfer tube for an evaporator of absorption system applications. Five types of heat transfer tubes with different shape and heat transfer area are tested in the present experiment. Heat transfer and pressure drop performance of heat transfer tubes are measured in various operating conditions, and compared each other. The results show that the heat transfer coefficient of thermoexcel notch tube increases about 79.6% and 45.3% at the film Reynolds number 69.7 compared with that of bare tube and low fin tube, respectively. The thermoexcel notch tube is show the best performance considering pressure drop and heat transfer coefficient.

수평형 재생증발식 냉방기의 성능시험 (Performance Test for a Horizontal Regenerative Evaporative Cooler)

  • 송귀은;이대영
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.621-626
    • /
    • 2006
  • Regenerative evaporative cooling is known as an environment-friendly and energy efficient cooling method. A regenerative evaporative cooler (REC) consisting of dry and wet channels is able to cool down the air stream below the inlet wet-bulb temperature. In the regenerative evaporative cooler, the cooling effect is achieved by redirecting a portion of the air flown out of the dry channel into the wet channel and spraying water onto the redirected air. In this study, a horizontal regenerative cooler is considered. In the horizontal regenerative cooler, the flow direction of evaporating water has a right angle to the flow direction of supply air. This difference was investigated with visualization technique and simplified 2-module performance test was done in a thermo-environment chamber. Optimum design configuration is changed due to the wet channel which are easily fully covered with evaporating water and block the air flow inside the channel. Applying the optimized fin configuration design with the highly wetting surface treatment, a regenerative evaporative cooler was fabricated and tested to Identify the cooling performance improvement and operation characteristics. From the experimental results at the intake condition of $32^{\circ}C$ and 50% RH, the supply temperature was measured to be around $23.4^{\circ}C$. The cooling effectiveness based on the inlet dewpoint temperature was evaluated 73% which is almost close to the design expectation.

  • PDF

쥐가오리 모방 진동식 조류 터빈의 출력향상에 대한 실험적 연구 (Experimental Study on Power Improvement of a Flapping Tidal Stream Turbine by Mimicking a Manta-Ray)

  • 고진환;김지훈
    • Ocean and Polar Research
    • /
    • 제39권4호
    • /
    • pp.293-300
    • /
    • 2017
  • Various approaches have been tried in an effort to improve the power performance of a flapping tidal stream turbine after it was introduced as an alternative to conventional rotary turbines. Among the different approaches, researches on mimicking the morphology and behavior of animals have been conducted. In this study, we utilized a flapper to mimic the multi-joint pectoral fin of a Manta-ray and investigated its effect on power generation. Experiments were conducted by a dual flapping apparatus with rigid and flexible flappers in a towing tank facility. First, in order to determine the conditions that can produce high power generation, the performances of the dual rigid flappers were compared when input arm angles and frequencies are changed, and the two conditions $40^{\circ}$, 0.2 Hz and $40^{\circ}$, 0.3 Hz for the input arm angle, frequency were selected. When the mimicked flexible flapper was used instead of the front rigid flapper and the rear one, the power was improved by an average of 22% and 38% in the experimental conditions, respectively. Moreover, it was recognized from the apparent camber observed during the experiment that the flexible flapper had been successfully applied. If the feasibility of the Manta-Ray mimicked flapper is improved through subsequent researches, the flapping tidal turbine can be a viable alternative to rotary turbines in the near future.

경계적분방정식을 이용한 축대칭 열전도 고체의 형상설계민감도 해석 (Shape Design Sensitivity Analysis of Axisymmetric Thermal Conducting Solids Using Boundary Integral Equations)

  • 이부윤
    • 대한기계학회논문집
    • /
    • 제17권1호
    • /
    • pp.141-152
    • /
    • 1993
  • 본 연구에서는 축대칭 열전도 고체의 형상설계민감도 해석을 위하여 2차원 문 제를 다룬 Lee, Choi와 Kwak의 방법을 축대칭 문제로 확장하였다.축대칭 형태로 표 시된 직접 및 간접 경계적분방정식의 정식화에 기초하여 전미분방접과 보조변수방법으 로 형상최적화 문제에서 발생하는 일반적인 성능 범함수의 형상설계민감도 공식을 유 도하고, 온도 및 열속의 제한조건에 이를 응용하였다. 제시된 민감도해석방법의 정 확성을 검증하기 위하여 해석적인 해를 갖는 원통문제와 구문제를 다루었는데, 두 문 제에 대하여 민감도 공식을 이용하여 수치계산된 결과를 해석적인 민감도와 비교하였 다. 또한 복잡한 수치해로서 냉각핀(cooling fin)문제를 다루었으며, 민감도 공식에 의한 계산 결과를 유한차분(finite difference)으로 수치미분한 결과와 비교하였다.

위조지문 판별률 향상을 위한 학습데이터 혼합 증강 방법 (Data Mixing Augmentation Method for Improving Fake Fingerprint Detection Rate)

  • 김원진;김성빈;유경송;김학일
    • 정보보호학회논문지
    • /
    • 제27권2호
    • /
    • pp.305-314
    • /
    • 2017
  • 최근 모바일 및 핀테크(fin-tech) 분야의 최신 트렌드로 지문인식, 홍채인식과 같은 생체인식을 통한 사용자 본인인증이 주목 받고 있다. 특히 지문인식을 이용한 인증 방식은 전통적인 생체인식 방식으로써 사용자들이 사용하는데 발생하는 거부감이 다른 생체인식에 비해 현저히 낮아 현재 가장 보편적으로 이용되는 방식이다. 이와 동시에 지문을 이용한 인증 시 보안에 대한 중요성이 부각되어 지문의 위조 여부 판별의 중요성 또한 증가하고 있다. 본 논문에서는 CNN(Convolutional Neural Networks) 특징을 이용한 위조 여부 판별 방법에 있어 판별률을 향상시키기 위한 새로운 방법을 제시한다. 학습데이터에 영향을 많이 받는 CNN 특성 상 기존에는 판별률을 향상시키기 위해 아핀 변환(affine transformation) 또는 수평 반전(horizontal reflection)을 사용하여 학습데이터의 양을 증가 시키는 것이 일반적인 방법이었으나 본 논문에서는 위조지문 판별 난이도를 기반으로 한 효과적인 학습데이터 증강(data augmentation) 방법을 제시하며 실험을 통해 제안하는 방법의 타당성을 확인하였다.

곡관부 하류에 핀휜이 부착된 회전 냉각유로의 최적설계 (Optimization of a Rotating Two-Pass Rectangular Cooling Channel with Staggered Arrays of Pin-Fins)

  • 문미애;김광용
    • 한국유체기계학회 논문집
    • /
    • 제13권5호
    • /
    • pp.43-53
    • /
    • 2010
  • This study investigates a design optimization of a rotating two-pass rectangular cooling channel with staggered arrays of pin-fins. The radial basis neural network method is used as an optimization technique with Reynolds-averaged Navier-Stokes analysis of fluid flow and heat transfer with shear stress transport turbulent model. The ratio of the diameter to height of the pin-fins and the ratio of the streamwise spacing between the pin-fins to height of the pin-fin are selected as design variables. The optimization problem has been defined as a minimization of the objective function, which is defined as a linear combination of heat transfer related term and friction loss related term with a weighting factor. Results are presented for streamlines, velocity vector fields, and contours of Nusselt numbers, friction coefficients, and turbulent kinetic energy. These results show how fluid flow in a two-pass square cooling channel evolves a converted secondary flows due to Coriolis force, staggered arrays of pin-fins, and a $180^{\circ}$ turn region. These results describe how the fluid flow affects surface heat transfer. The Coriolis force induces heat transfer discrepancy between leading and trailing surfaces, having higher Nusselt number on the leading surface in the second pass while having lower Nusselt number on the trailing surface. Dean vortices generated in $180^{\circ}$ turn region augment heat transfer in the turning region and in the upstream region of the second pass. As the result of optimization, in comparison with the reference geometry, thermal performance of the optimum geometry shows the improvement by 30.5%. Through the optimization, the diameter of pin-fin increased by 14.9% and the streamwise distance between pin-fins increased by 32.1%. And, the value of objective function decreased by 18.1%.