• Title/Summary/Keyword: Fin Performance

Search Result 572, Processing Time 0.021 seconds

The Impact of ESG Management on the FinTech Industry: Focusing on the Case of K-Pay's inclusion in the MSCI Index (ESG 경영이 핀테크 산업에 미치는 영향: MSCI 지수 편입 카카오페이 사례를 중심으로)

  • Hanjin Lee;Ju-young Ha;Gaeun Son;Subin Kim;Donghyun Yoon
    • Journal of Information Technology Services
    • /
    • v.22 no.4
    • /
    • pp.171-184
    • /
    • 2023
  • FinTech, which has brought innovation to the financial industry thanks to the advancements in ICT since 2010, has contributed to the growth of the financial ecosystem and increased consumer benefits. Furthermore, there has been a growing demand for social responsibility and sustainability in financial institutions, which have a significant impact on governments, businesses, and people's lives. Despite this, many FinTech companies and traditional financial institutions are still in the early stages of establishing ESG (Environmental, Social, and Governance) management philosophy or lack long-term plans. In this study, we aim to examine the impact of ESG management on the FinTech industry, focusing on representative domestic cases, and derive policy and institutional measures to spread it in the financial industry. Specifically, we will adopt MSCI rating indicators, which are internationally accepted by various industries such as manufacturing, healthcare, and transportation, to evaluate the 35 ESG management subcategories of FinTech companies. As a result, a total of 22 compliance items were disclosed in the ESG report, and it was possible to confirm the detailed management. Through this, we intend to propose effective management strategies for the organizational structure, operations, programs, and performance evaluation of FinTech companies, which are positioning themselves as sustainable growth drivers in the domestic industry.

An Experimental Study on the Supplemental Cooling and Heating Performance Using 1 kW Thermoelectric Module for Vehicle (열전모듈을 이용한 자동차용 1 kW급 보조 냉난방 시스템의 성능에 관한 실험적 연구)

  • Lee, Dae-Woong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.5
    • /
    • pp.224-230
    • /
    • 2014
  • The purpose of this paper is to investigate the performance of supplemental cooling and heating system equipped with the 1 kW thermoelectric module. The system consist of 96 thermoelectric modules, heat sink with louver fin and water cooling jacket which is attached on the hot side of the thermoelectric module. The cooling and heating performance test of the thermoelectric system is conducted with various conditions, such as intake voltage, air inlet temperature, air flow volume, water inlet temperature and water flow rate at calorimeter chamber in consideration of environmental conditions in realistic vehicle drive. The experimental results of a thermoelectric system shows that the cooling capacity and COP is 1.03 kW, and 1.0, and heating capacity and COP is 1.53 kW, and 1.5 respectively.

Investigation of Cooling Performance of the Driving Motor Utilizing Heat Pipe (히트파이프를 부착한 구동모터의 냉각성능에 관한 연구)

  • Lee, Dong-Ryul
    • Journal of Power System Engineering
    • /
    • v.10 no.4
    • /
    • pp.11-16
    • /
    • 2006
  • This research is to verify the cooling effect of the acting surface on the rotary motor using heat pipe and conventional cooling fan. In order to show the cooling performance of the rotary motor and heat pipe with the fin-typed heat sink, the surface temperature of the motor and condenser was measured in real time. The experiments were also conducted as for not only cooling device installed with heat pipe only, but with heat pipe and conventional cooling fan simultaneously. The present experiment reveals that the cooling combination of the heat pipe and cooling fan is far superior to the conventional cooling device for the driving motor such as the fin-typed heat sink. When the driving voltage of 20V and 14V were supplied to the driving motor, the cooling performance of the rotary motor with heat pipe was 170% and 500%, respectively better than that without heat pipe on steady state condition.

  • PDF

Analysis of the CATR Equipped with the Novel Shark-Fin Shaped Serrations by the Height Modulation (높이가 다른 Shark-Fin 형태의 서레이션을 갖는 CATR의 특성 해석)

  • Choi, Dong-Won;Choi, Hak-Keun;Park, Jae-Hyun;Lim, Seong-Bin
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.4
    • /
    • pp.371-380
    • /
    • 2010
  • The CATR(Compact Antenna Test Range) is a testing facility which is to provide the uniform plane wave by using the reflector. As the ripple of the uniform plane wave caused by the diffraction rays at the edge of the reflector, serrations are attached at the edge of the reflector to minimize the ripple of the uniform plane wave in the CATR. The diffraction field of the serration is normally analyzed by the Fresnel diffraction formula which is expressed as the double integration, and the structure of the serration is expressed as Fourier series to apply the double integration of the Fresnel diffraction formula. In this paper, the novel shark-fin shaped serrations which have the height modulation of the adjacent serrations are proposed. And the triangular serrations and the novel shark-fin shaped serrations are compared to confirm that the performance of the quiet zone by the shark-fin shaped serrations is better than by the triangular serrations. It is also confirmed that the novel shark-fin shaped serrations which have the height modulation of the adjacent serrations are lower ripple than which have the same height of the adjacent serrations. Accordingly, the novel shark-fin shaped serrations with the height modulation can be used at the edge of the reflector to provide the uniform plane wave in CATR.

Air-side Heat Transfer and Friction Characteristics of Finned Tube Beat Exchangers with Slit Fin or Plain Fin (슬릿과 평판 핀-관 열교환기의 공기측 열전달 및 마찰특성)

  • Kwon, Young-Chul;Chang, Keun-Sun;Park, Byung-Kwon;Kwon, Jeong-Tae;Jeong, Ji-Hwan
    • Journal of Energy Engineering
    • /
    • v.16 no.1 s.49
    • /
    • pp.7-14
    • /
    • 2007
  • An experimental study is performed to investigate the effect of air-side heat transfer and friction on characteristics of finned tube heat exchanger under dry surface and wet surface conditions (RH 50%, 70%). Air enthalpy calorimeter is used to obtain the performance evaluation and analysis of a fined tube heat exchanger. Four finned tube heat exchangers with slit fin or plain fin are tested. The number of tube rows are 2 and 3, and the tube diameter is 7 mm. Air-side heat transfer and friction are presented in terms of j factor and friction factor. At dry surface condition, j factor decreases with increasing Re and j factor of 3 row is lower than that of 2 row. Also, the friction factor of a slit fin is larger than that of a plain fin. At wet surface condition, the heat transfer effect is more significant in the case of the slit fin than the plain fin and 2 row than 3 row. The j factor and friction factor are affected by humidity, tube row and fin configuration.

Numerical Analysis on Heat Gain of Liquid from Ambient Air with Various Fin Heights and Pitches of Fin-and-Tube Heat Exchanger in Hybrid Solar Collector (핀-튜브 열교환 구조를 갖는 복합집열기에서 핀 높이 및 간격에 따른 공기열 이용 액체 가열 성능에 관한 수치해석 연구)

  • Choi, Hwi-Ung;Fatkhur, Rokhman;Lyu, Nam-Jin;Yoon, Jung-In;Son, Chang-Hyo;Choi, Kwang-Hwan
    • Journal of the Korean Solar Energy Society
    • /
    • v.36 no.3
    • /
    • pp.53-61
    • /
    • 2016
  • Solar assisted heat pump system uses solar thermal energy as a heat source of evaporator of heat pump. So, COP can be enhanced as well as collector efficiency. For improving performance of this system, some research about hybrid solar collector that has fin-and-tube heat exchanger has been conducted. This collector can get a thermal energy from ambient air for liquid heating, so heated liquid can be used as a heat source of evaporator in heat pump even the solar radiation is not enough. In this study, numerical analysis was conducted for confirming heat gain of liquid according to fin height and pitch of fin-and-tube heat exchanger in collector. As a result, higher heat gain was obtained on lower fin height and narrow fin pitch, but the pressure drop also increased with increment of heat gain. Thus the JF factor considering both heat transfer enhancement and pressure drop was investigated and the maximum value was shown when the fin height and pitch were 40mm and 45mm. So it is considered that this installation condition has a highest heat transfer improvement when comparing with pressure drop. However heat gain of liquid at this condition was less than the other installation conditions of fin pitch on same height. Then, after establishing a proper minimum heat gain of liquid, actual production and experiment of collector will be conducted with fin height and pitch showing maximum JF factor and satisfying selected minimum heat gain of liquid on the basis of results of this study.

Experimental Analysis of Towing Attitude for I-type and Y-type Tail Fin of Active Towed SONAR (I 형 및 Y 형 꼬리 날개 능동 예인 음탐기의 예인 자세에 대한 실험적 분석)

  • Lee, Dong-Sup
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.8
    • /
    • pp.579-585
    • /
    • 2019
  • Increasing the detection probability of underwater targets necessitates securing the towing stability of the active towed SONAR. In this paper, to confirm the effects of tail wing fin on towing attitude and towing stability, two scale model experiments and one sea trials were conducted and the results were analyzed. The scale model tests measured the towing behavior of each of the tail fin shapes according to towing speed in a towing tank. The shape of the tail fin used in the scale model test was tested with an I-type tail fine and four Y-type tail fins, totaling five tail fins of the two kinds. The first scale model test confirmed that the Y-type tail fin was superior to the I-type tail fin in towing attitude and towing stability. The second scale model test confirmed the characteristics of the vertical tail fin height increase and the lower horizontal tail fin inclination angle application shape based on the Y-type tail fin. The shape of the application of the lower horizontal tail fin inclination angle showed the best performance. In order to verify the results of the scale model test, a full size model was constructed, sea trials were performed, and the towing attitude was measured. The results were similar to those of the scale model test.

Experimental Investigation of Variations in Inclination Angle of Natural Convective Heat Sink with Plate Fins (플레이트-휜을 가지는 자연대류 히트싱트의 경사각 변화에 대한 실험적 연구)

  • Do, Kyu-Hyung;Kim, Tae-Hoon;Han, Yong-Shik;Choi, Byung-Il;Kim, Myung-Bae
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.6
    • /
    • pp.571-578
    • /
    • 2012
  • In this paper, an experimental investigation is performed to estimate the thermal performance of a natural convective heat sink with plate fins subject to the uniform wall temperature condition. Extensive experiments are performed with various input powers, fin spacings, and heights of the natural convective heat sinks with plate fins. In particular, the effect of the inclination angle on the thermal performance of the heat sink is studied. In order to validate the experimental data, the experimental results are compared with results from previous studies. Based on the experimental results, the appropriate ranges of the previous correlations between the input power, the fin spacing, the fin height, and the inclination angle for the natural convective heat sink with plate fins are evaluated.

Experimental Study on Performance Comparison of Air-Conditioner with PF Heat Exchanger (PF 열교환기를 적용한 공조기의 성능 비교 실험연구)

  • Kwon, Young-Chul;Park, Yoon-Chang
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.3
    • /
    • pp.470-475
    • /
    • 2009
  • In the present study, the heat transfer characteristics of the fin-tube and PF heat exchangers and the performances of the air-conditioner are experimentally investigated. Also, Cooling Seasonal Performance Factor(CSPF) of the air-conditioner is evaluated. For the heat exchanger experiment, the heat transfer and pressure drop are obtained. For the air-conditioner experiment, the cooling capacity, input power and COP are obtained. The air-enthalpy calorimeter and the constant temperature water bath are used. As the inlet air velocity increases, the heat transfer rate and pressure drop of the heat exchanger increased. PF heat exchanger has smaller refrigerant weight and larger capacity and COP than the fin-tube heat exchanger. The performance of PF-2 heat exchanger with the squarer fin is more excellent than that of PF-1 heat exchanger with the triangler fin. Also, CSPF of the fm -tube and PF heat exchanger is evaluated.

Computational study of orientation effects on thermal performance of natural convection cooled lightweight high performance hollow hybrid fin heat sinks (자연대류 냉각되는 경량고성능 할로우 하이브리드 휜 히트싱크의 열성능에 대한 방향 영향의 전산연구)

  • Effendi, Nico Setiawan;Kim, Kyoung-Joon
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.9
    • /
    • pp.786-790
    • /
    • 2016
  • This paper discusses numerically explored orientation effects on the thermal performance of hollow hybrid fin heat sinks (HHFHSs) under natural convection. A HHFHS consists of an array of hollow pin fins concatenated with plate fins and having perforations near the fin bases. Orientation effects on the footprint-based and mass-based thermal performance of the HHFHS were numerically studied for orientation angles ranging from $0^{\circ}$ to $180^{\circ}$. The performance of the HHFHS was compared with that of a pin fin heat sink (PFHS) having similar physical parameters. The results show that the thermal resistance of the HHFHS did not vary considerably from $0^{\circ}$ to $45^{\circ}$. The thermal resistance increased from $45^{\circ}$ to $90^{\circ}$, reached its maximum at $90^{\circ}$, and decreased consistently from $90^{\circ}$ to $180^{\circ}$. Dissimilar behaviors of the thermal resistance of the HHFHS vs. the PFHS resulted mainly from the effect of heat pumping induced by the internal flows of the hollow fins. Despite various orientations, the mass-based thermal resistance of the HHFHS was found to be nearly 30% smaller than that of the PFHS. This result shows the feasibility of the HHFHS for the lightweight thermal management of electronics under natural convection.