• 제목/요약/키워드: Fin Performance

검색결과 572건 처리시간 0.033초

휜-관 열교환기의 착.제상 거동에 대한 표면처리의 영향에 관한 실험적 연구 (An Experimental Study of the Surface Treatment Effect on the Frosting/Defrosting Behavior of a Fin-Tube Heat Exchanger)

  • 지성;이관수
    • 대한기계학회논문집B
    • /
    • 제24권8호
    • /
    • pp.1062-1068
    • /
    • 2000
  • The effect of heat exchanger surface treatment on the frosting/defrosting behavior in a fin-tube heat exchanger is investigated experimentally. It is found that the hydrophilic surface mainly influences on the frosting behavior, however, the hydrophobic surface gives some influence on the defrosting behavior. In view of frosting performance, surface-treated heat exchanger with either hydrophilic or hydrophobic characteristic shows a little improvement in the thermal performance than the aluminium heat exchanger with no surface treatment. The result reveals that the heat exchanger with hydrophobic surface treatment is more effective in view of the defrosting efficiency and time. The amounts of residual water on the surface-treated heat exchangers are shown to be smaller than those of the bare heat exchanger, therefore further improvements on the performance of re-operations are expected.

내면가공 핀튜브 흡수기의 열 및 물질전달특성 (Characteristic of Heat and Mass Transfer on Inner Ribbed Notched Fin Tube Absorber)

  • 설원실;권오경;문춘근;정용옥;윤정인
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제24권4호
    • /
    • pp.478-485
    • /
    • 2000
  • An experimental study of the absorption process of water vapor into lithium bromide solution was performed. For the purpose of development of high performance absorption chiller-heater utilizing Lithium Bromide solution as working fluid, the absorber is the most effective to improve the performance of an absorber because it requires the largest heat transfer area in an absorption chiller-heater system. This paper introduces bare tube and inner ribbed notched fin tube for the absorber of absorption chiller-heaters. Inner ribbed notched fin tube has about 10∼20% higher heat and mass transfer performance than bare tube conventionally used in absorbers and the it is expected to perform high heat and mass transfer. This paper will provide important information on the selection of absorber tubes in commercial absorption chill-heaters.

  • PDF

CFD를 이용한 히트싱크의 열 해석 (Thermal Analysis of Heat Sink Models using CFD simulation)

  • 임송철;이명호;강계명
    • 한국재료학회지
    • /
    • 제15권12호
    • /
    • pp.829-832
    • /
    • 2005
  • Thermal analysis of new designed heat-sink models was carried out according to the natural ana the forced convection using computational fluid dynamics(CFD). Heat resistance of wave type, top vented wave type and plate type of heat sink was compared with each other As the direction of fin and air flow are vertical(z-axis), it is shown that radiant heat performance of all of heat sinks was superior than other experimental conditions. Especially, the heat resistance of top vented wave heat sink was $0.17^{\circ}C/W$(forced convection) and $0.48^{\circ}C/W$(natural convection). The radiant heat performance of heat sink was increased with increasing the height of fin and the width of fin pitch.

이산화탄소용 핀-관 증발기의 성능해석 (Performance Analysis of Fin-tube Evaporator for Carbon Dioxide)

  • 이민규;김영일;장영수;김용찬
    • 설비공학논문집
    • /
    • 제16권7호
    • /
    • pp.645-651
    • /
    • 2004
  • Fin-tube evaporator for carbon dioxide has been investigated both by experiment and simulation. Inside refrigerant heat transfer and outside heat and mass transfer of a wet surface heat exchanger were modeled using appropriate correlations. The results estimated by the calculation were in good agreement with the experimental results. The simulation errors were less than 7.9% for estimating capacity, 0.6$^{\circ}C$ for air exit temperature, 1.2% for air exit humidity and 17% for $CO_2$ exit pressure. The simulation program was used to study the effect of air flow direction, number of rows and refrigerant circuits. For a 2-row evaporator, parallel flow showed better performance for low air velocity but for high air velocity, counter-flow was better. Refrigerant circuits, however, showed insignificant effect on the performance.

광폭 루버 핀이 장착된 핀-관 열교환기의 습표면 성능에 대한 실험적 연구 (Experimental Study on the Airside Performance of Fin-and-Tube Heat Exchangers Having Wide Louver Fins Under Wet Conditions)

  • 김내현
    • 대한기계학회논문집B
    • /
    • 제39권9호
    • /
    • pp.719-726
    • /
    • 2015
  • 전열량을 늘리는 손쉬운 방법은 전열면적을 크게 하는 것이다. 본 연구에서는 세로와 가로 방향 튜브 핏치의 비(Pt/Pl)가 1.03인 광폭 루버 핀 시료의 습표면 j와 f 인자를 실험을 통하여 구하고 Pt/Pl=0.6인 일반 루버 핀 시료와 비교하였다. 동일 소비동력에서 광폭 루버 핀 시료의 전열성능이 일반 루버 핀 시료보다 1열에서 평균 16%, 2열에서 평균 29%, 3열에서 평균 38% 크게 나타났다. 이 증가량은 핀 면적의 증가량 (2.17배)에 비하면 현저히 작은데 이는 광폭 루버 핀 시료의 열전달계수와 핀 효율이 일반 루버 핀 시료의 값들보다 작기 때문이다. 핀 핏치가 j와 f 인자에 미치는 영향이 크지 않았다. 또한 튜브 열수가 증가할수록 j와 f 인자는 감소하였다. 실험 데이터를 기존 상관식과 비교하였다.

응축기용 낮은 핀관의 내부 나선 홈에 의한 응축 열전달 성능과 압력손실에 관한 연구 (A Study on the Condensation Heat Transfer and Pressure Drop in Internally Grooved Tubes Used in Condenser)

  • 한규일;조동현
    • 수산해양기술연구
    • /
    • 제34권2호
    • /
    • pp.212-222
    • /
    • 1998
  • Heat transfer performance improvement by fin and groovs is studied for condensation of R-11 on integral-fin tubes. Eight tubes with trapczodially shaped integral-fins having fin density from 748 to 1654fpm(fin per meter) and 10, 30 grooves are tested. A plain tube having the same diameter as the finned tubes is also used for comparison. R-11 condensates at saturation state of 32 $^{\circ}C$ on the outside tube surface coded by inside water flow. All of test data are taken at steady state. The heat transfer loop is used for testing singe long tubes and cooling is pumped from a storage tank through filters and folwmeters to the horizontal test section where it is heated by steam condensing on the outside of the tubes. The pressure drop across the test section is measured by menas pressure gauge and manometer. The results obtained in this study is as follows : 1. Based on inside diameter and nominal inside area, overall heat transfer coefficients of finned tube are enhanced up to 1.6 ~ 3.7 times that of a plain tube at a constant Reynolds number. 2. Friction factors are up to 1.6 ~ 2.1 times those of plain tubes. 3. The constant pumping power ratio for the low integral-fin tubes increase directly with the effective area to the nominal area ratio, and with the effective area diameter ratio. 4. A tube having a fin density of 1299fpm and 30 grooves has the best heat transfer performance.

  • PDF

복합 전열 촉진 핀이 적용된 핀-관 열교환기의 습표면 성능에 대한 실험적 연구 (An Experimental Study on Air-Side Performance of Fin-and-Tube Heat Exchangers Having Compound Enhanced Fins Under Wet Condition)

  • 김내현
    • 한국산학기술학회논문지
    • /
    • 제16권9호
    • /
    • pp.5778-5788
    • /
    • 2015
  • 본 연구에서는 복합 전열 촉진 핀 열교환기의 습표면 열전달 및 압력손실에 대하여 실험적으로 검토하였다. 비교를 위하여 널리 사용되는 루버 핀 열교환기에 대한 실험도 수행하였다. 핀 핏치(1.5mm~1.7mm)와 열수(1열~3열)를 변화시키며 열전달 및 압력손실에 미치는 영향을 검토하였다. 실험범위에서 핀 핏치가 j와 f 인자에 미치는 영향은 크지 않았다. 열수가 증가하면 j와 f 인자 모두 감소하였다. 복합 전열 핀 열교환기의 j와 f 인자가 루버 핀 열교환기의 값들보다 크게 나타났다. 1열의 경우 평균 j 인자와 f 인자는 11%, 43% 크고, 2열에서는 8%, 50%, 3열에서는 17%, 53% 크게 나타났다. 동일 압력 손실 대비 전열 성능은 복합 전열 촉진 핀 열교환기가 1열에서 2.0%, 2열에서 3.1%, 3열에서 8.4% 크게 나타났다. 실험 자료를 기존 루버 핀 상관식과 비교하였다.

비대칭형 슬릿 핀이 적용된 핀-관 열교환기의 습표면 성능 (Air-Side Performance of Fin-and-Tube Heat Exchangers Having Non-Symmetric Slit Fins Under Wet Condition)

  • 김내현
    • 한국산학기술학회논문지
    • /
    • 제16권6호
    • /
    • pp.3698-3707
    • /
    • 2015
  • 본 연구에서는 비대칭형 슬릿 핀 열교환기의 습표면 열전달 및 압력손실에 대하여 실험적으로 검토하였다. 비교를 위하여 널리 사용되는 루버 핀 열교환기에 대한 실험도 수행하였다. 실험범위에서 핀 핏치가 j와 f 인자에 미치는 영향은 크지 않았다. 또한 루버 핀 시료의 j와 f 인자가 슬릿 핀 시료의 값들보다 크게 나타났다. 1열의 경우 평균 j 인자와 f 인자는 27%, 31% 크고, 2열에서는 15%, 30% 크게 나타났다. 슬릿 핀과 루버 핀 모두 열수가 증가하면 j와 f 인자가 감소하였다. 슬릿 핀의 평균 j/f가 루버 핀보다 1열에서 3.4%, 2열에서 11.5% 크게 나타났다. 본 데이터로부터 새로운 상관식을 도출하였다.

수평채널에서 핀-휜을 가진 평판의 길이변화에 따른 열전달 특성 (Heat Transfer Characteristics depending on the Length of a Plate with Pin-Fin Array in a Horizontal Channel)

  • 손영석;신지영;이상록
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2408-2413
    • /
    • 2007
  • Since the heat generation in a chip increases as the components are miniaturized and the computing speed becomes faster, suitable heat dissipation has become one of the primary limiting factors to ensure the reliable operation of the electronic devices. A pin-fin array could be used as an alterative cooling system of the electronic equipment. In this study, convective heat transfer through the pin-fin array is analyzed experimentally based on porous medium approach. The influence of the structure of the pin-fin array including the pin-fin spacing, the pin diameter and plate length on heat transfer characteristics is investigated and compared with the previous analytical results and existing correlation equations. Nowadays, electronic and mechanical devices become smaller and smaller. In this sense, the main purpose of this study is to decide the optimum pin-fin arrangement to get similar heat transfer performance when the length of the existing cooling system is reduced as a half.

  • PDF

흡착식 냉동기의 흡착탑에서 열 및 물질전달에 관한 수치적 연구 (A Numerical Study for the Heat and Mass Transfer in Silica gel/Water Adsorption Chiller's Adsorber)

  • 권오경;윤재호;김종하;김용찬;주영주
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.341-346
    • /
    • 2005
  • Nowadays, adsorption chillers have been receiving considerable attentions as they are energy-saving and environmental1y benign systems. A Fin & tube type heat exchanger in which adsorption/desorption take place is required more compact size. The adsorption chiller is expected to have high energy-efficiency in utilizing the waste heat exhausted from a process. The objectives of this paper are to investigate the effect of fin pitch of fin & tube on the adsorption performance and to develop an optimal design fin & tube heat exchanger in the silica gel/water adsorption chiller. Previous study concluded that optimal particle size selected 0.5mm, type HO silica gel, and fundamental heat transfer & mass transfer experiments carried out. From the numerical results, the adsorption rate for the fin pitch 2.5mm is the highest than that for the fin pitch 5mm, 7.5mm and 10mm. Also cooling water & hot water temperature affect the adsorption rate.

  • PDF