• Title/Summary/Keyword: Filtration Resistance

Search Result 193, Processing Time 0.025 seconds

A Study on the Limited Rate Power Capacity for Applications for Precision Passive Devices Based on Carbon Nanotube Materials (탄소나노튜브 소재의 정밀 수동소자 적용을 위한 한계 정격전력 용량에 관한 연구)

  • Lee, Sunwoo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.35 no.3
    • /
    • pp.269-274
    • /
    • 2022
  • We prepared carbon nanotube (CNT) paper by a vacuum filtration method for the use of a chip-typed resistor as a precision passive device with a constant resistance. Hybrid resistor composed of the CNT resistor with a negative temperature coefficient of resistance (T.C.R) and a metal alloy resistor with a positive T.C.R could lead to a constant resistance, because the resistance increase owing to the temperature increase at the metal alloy and decrease at the CNT could counterbalance each other. The constant resistance for the precision passive devices should be maintained even when a heat was generated by a current flow resulting in resistance change. Performance reliabilities of the CNT resistor for the precision passive device applications such as electrical load limit, environmental load limit, and life limit specified in IEC 60115-1 must be ensured. In this study, therefore, the rated power determination and T.C.R tests of the CNT paper were conducted. -900~-700 ppm/℃ of TCR, 0.1~0.2 A of the carrying current capacity, and 0.0625~0.125 W of the rated power limit were obtained from the CNT paper. Consequently, we confirmed that the application of CNT materials for the precision hybrid passive devices with a metal alloy could result in a better performance reliability with a zero tolerance.

Effect of Porous Filter Structure on Specific Cake Resistance and Porosity in Dead-end Filtration (Dead-end Filtration에서 Dust Cake 비저항과 기공율에 대한 다공성 필터 구조의 영향)

  • 이선희;조영민;유정근
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2003.05b
    • /
    • pp.405-406
    • /
    • 2003
  • 분진여과시 형성되는 분진 케이크는 궁극적인 여과 성능을 좌우하며, 필터의 구조, 분진 입자의 형태나 크기, 분진농도, 여과속도 등에 의해 영향을 받는다 특히 필터의 표면 구조나 기공 크기는 여과 초기 단계의 케이크 층의 구조를 결정하며, 연속적인 여과시 초기 케이크 층은 다음에 쌓이는 케이크 형성과 비저항에 영향을 주므로 필터 medium 구조 또한 분진여과 과정에서 중요한 영향 요인이 된다. 본 연구에서는 필터 medium의 구조가 서로 다른 고온가스정화용 복합 세라믹 필터, metal fiber mat, 스테인레스 필터를 이용하여 분진농도와 여과속도를 변수로 하여 분진 여과 실험을 함으로써 각각의 필터에 대한 케이크 비저항과 기공율을 실험과 이론식으로부터 추정하였다. (중략)

  • PDF

Effects of sodium hydroxide cleaning on polyvinylidene fluoride fouled with humic water

  • Jang, Yoon-sung;Kweon, JiHyang;Kang, Min-goo;Park, Jungsu;Jung, Jae Hyun;Ryu, JunHee
    • Membrane and Water Treatment
    • /
    • v.8 no.2
    • /
    • pp.149-160
    • /
    • 2017
  • This study investigated effects of NaOH cleaning on the intrinsic permeability of polyvinylidene fluoride (PVDF) membranes and flux recoveries and membrane resistances under various conditions encountered during ultrafiltration in water treatment plants. The NaOH cleaning using 10,000 mg/L NaOH led to discoloration of PVDF membranes and had little effect on water flux. The NaOH cleaning was efficient in removing the fouling layer caused by humic water. However, long filtration induced a fouling layer that was not removed easily by NaOH cleaning. The lower temperature during filtration yielded rapid increases in transmembrane pressure and decreases in NaOH cleaning efficiency. The alkaline cleaning of PVDF changed the membrane properties such as the hydrophobicity and morphology. Foulant properties, operational conditions such as temperature, and chemical agents should be considered for cleaning strategies for PVDF applied in water treatment.

Performance Study of Composite Air Filters Using Heterogeneous Fibers

  • Lee, Ji Soo;Oh, Yuree;Kim, Heejin;Park, Hyun-Seol;Yoon, Sam S.;Lee, Min Wook
    • Composites Research
    • /
    • v.35 no.3
    • /
    • pp.216-221
    • /
    • 2022
  • Recently, the worldwide demand for disposable masks has increased due to COVID-19 infections and severe air pollution. Personal masks should reduce breathe resistance while maintaining filtering performance. In this study, a solution blowing process is used to produce composite nanofiber filters to co-spin two polymers at once. The manufacture process of the various fiber diameter filter was designed, and the filtration performance and differential pressure of the prepared filter was investigated. Poly vinylidene fluoride-hexafluoropropylene (PVDF-HFP) and Polylactic acid (PLA) fibers were chosen to be entangled together in a layer with a diameter of 1.05 ㎛ and 0.33 ㎛. Composite nanofilters showed up to 87% filtration efficiency and 32 Pa differential pressure.

Effect of Operating Conditions and Recovery of Water Back-washing in Spiral Wound Microfiltration Module Manufactured with PVDF Nanofibers for Water Treatment (수처리용 PVDF 나노섬유 나권형 정밀여과 모듈에서 운전조건의 영향과 물 역세척 회복)

  • Kyung, Kyu Myung;Park, Jin Yong
    • Membrane Journal
    • /
    • v.25 no.2
    • /
    • pp.180-190
    • /
    • 2015
  • PVDF (polyvinylidene fluoride) nanofiber has the advantages such as excellent strength, chemical resistance, nontoxic, non-combustibility. Flat membranes with 0.3 and $0.4{\mu}m$ pore size respectively, were manufactured by PVDF nanofiber, and then each spiral wound module was prepared with them. A woven paper was not included in preparing the module with $0.3{\mu}m$ pore size; however, it was included the module with $0.4{\mu}m$ pore size. The permeate fluxes and rejection rates of the two modules were compared using pure water and simulation solution including kaolin and humic acid. The recovery rate and filtration resistance were calculated after water back-washing. In addition, the effect of flow rate and trans-membrane pressure on treatment efficiency and filtration resistance were investigated for the spiral wound module with $0.4{\mu}m$ pore size.

Effect of operating condition of electro-coagulation on the membrane filtration resistances of activated sludge (전기응집 조건이 활성슬러지 막 여과 저항에 미치는 영향)

  • Hong, Sung-Jun;Chang, In-Soung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.3
    • /
    • pp.2314-2320
    • /
    • 2015
  • MBR (Membrane Bio-Reactor) process is known to consume enormous energy to control membrane fouling. To solve this problem, electro-coagulation technique has been applied to MBR. A series of electro-coagulation was applied to activated sludge suspension under different current density condition. After the electro-coagulations, membrane filtration of the activated sludge suspensions was conducted to investigate the effect of electro-coagulation on the fouling. As current density increased 10 to 40A/m2, the total fouling resistance (Rc+Rf) decreased from 18 to 79%, showing that the electro-coagulation improved the membrane filtration efficiency. Both the organic concentration in bulk and the particles size distribution were not nearly changed before and after the electro-coagulation. The enhanced filtration efficiency might be due to the aluminum hydroxide generated from chemical precipitation, which can be acted as a dynamic membrane preventing a deposition of foulants on membrane surfaces.

The Role of pd in the Unified Theory on Solid-Liquid Separation: Especially on the Cake Thickness at Hindered Sedimentation, Cake Filtration and Expression (고액분리 통합이론에서 pd의 역할: 간섭침전, 케이크 여과, 압착에서 케이크 두께를 중심으로)

  • Yim, Sung-Sam;Song, Yun-Min
    • Korean Chemical Engineering Research
    • /
    • v.50 no.2
    • /
    • pp.334-342
    • /
    • 2012
  • To know the role of 'the solid compressive pressure to the first solid layer of a cake, $p_d$' in the 'unified theory on solid-liquid separation', we analyzed extremely compressible cake formed with floc for the following three operations with our new concepts. First, the role of $p_d$ was studied in calculating the sediment thickness of floc, and in calculating the cake thickness in cake filtration performed with floc sediment. Second, we calculated the expression procedure using $p_d$. Finally, the influence of $p_d$ on cake thickness in hindered sedimentation, and on the calculation of the procedure of hindered sedimentation $p_d$ was verified. Thus the possibility of application of 'unified theory on solid-liquid separation' and the importance of $p_d$ was verified. Through these processes, new theoretical definitions of the cake filtration, expression and hindered sedimentation was established.

Changes of physico-chemical properties of the activated sludges with anaerobic storage time (혐기화 시간에 따른 활성슬러지의 물리ㆍ화학적 특성변화)

  • 이창한;나영수;김도한;이송우;송승구
    • Journal of Environmental Science International
    • /
    • v.11 no.4
    • /
    • pp.339-346
    • /
    • 2002
  • Physico-chemical properties of the activated sludges(Suyoung and Changlim treatment plant), such as SVI(sludge volume index), absorbance, specific surface area, and specific resistance using Buchener funnel test were investigated with changing anaerobic storage time. This experimental condition was found that it was possible to estimate a linear relationship between their parameters such as specific surface area specific resistance, and sludge volume index(SVI). The specific surface area and the specific resistance to filtration of the activated sludges of Suyoung and Changlim treatment plant were found as 123.6~136.6$m^2$/gDS and 41.5~44.9$m^2$/gDS(dry solid), and 1.09$\times$10$^{14}$ ~5.48$\times$10$_{14}$ m/kg and 1.05$\times$10$^{14}$ ~2.48$\times$10$^{14}$ m/kg, respectively. The results gave a good linear relationship between the specific surface area and the specific resistance, r=2.25$\times$10$^{12}$ s-8.10$\times$10$^{13}$ ($R^2$=0.8885) at Suyoung treatment plant and r=1.26$\times$10$^{13}$ s-4.75$\times$10$^{14}$ ($R^2$=0.8756) at Changlim treatment plant.

The Inspection system development & Field experiments on performance evaluation for O & M RBF (기술사마당_기술자료 - 하상여과공법의 유지관리를 위한 조사장치 개발 및 현장 성능평가)

  • Oh, Ki-Sik;Cho, Tae-Ho
    • Journal of the Korean Professional Engineers Association
    • /
    • v.43 no.2
    • /
    • pp.53-59
    • /
    • 2010
  • This research is about the inspection system which is for maintenance of laterals of local RBF(River bed Filtration). Inspection system is designed for local use in order to endure water resistance up to 50m and it also can examine the internal condition and colgging of laterals by moving inside of the laterals about 100m back and forward. We will conduct performance test of inspection system at the lacal RBF site and present its result.

  • PDF

An Experimental Study and Modeling of Cake Resistance in Rotating Membrane Filtration (회전막 여과기에서의 케이크 저항에 관한 실험적 연구 및 모델링)

  • 박원철;김현우;최창균;박진용;김재진
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1997.10a
    • /
    • pp.120-122
    • /
    • 1997
  • 1. 서론 : 본 연구에서는 매우 안정된 유동의 하나로 막 표면의 전단력을 향상시켜 여과가 진행됨에 따라 막의 표면에서 발생하여 여과선속을 저하시키는 케이크층의 형성을 억제하는 데에 효과가 있다고 알려진 Taylor와류를 응용한 회전막 여과기를 사용하여 여과실험을 수행함으로써 이러한 유동이 케이크층의 형성에 미치는 영향을 살펴보았다. 또한 여과선속에 영향을 미치는 여러 매개인자들을 포함하는 새로운 모델식을 제안하고 실험결과와 비교해봄으로써 그 타당성을 살펴보았다.

  • PDF