• 제목/요약/키워드: Filtering capacity

검색결과 65건 처리시간 0.024초

생산능력 필터링 알고리즘 기반의 TFT-LCD Fab 투입계획 생성 방법론 (Capacity-Filtering Algorithm based Release Planning Method for TFT-LCD Fab)

  • 손학수;이호열;최병규
    • 산업공학
    • /
    • 제22권1호
    • /
    • pp.1-9
    • /
    • 2009
  • As the LCD fabrication factories (Fab) are highly capital-intensive and the markets are very competitive, it is an essential requirement of operational management to achieve full-capacity production while meeting customer demands on time. In a typical LCD Fab, medium-term schedules such as release plans and production plans are critical to achieve the goal of full-capacity production and on-time delivery. Presented in this paper is a framework for weekly planning system generating medium-term schedules using a finite-capacity planning method. Also this paper presents a release planning method applying capacityfiltering algorithm, especially backward capacity-filtering procedure, which is one of the finite-capacity planning methods. In addition, performance analyses using actual data of a TFT-LCD Fab show that the proposed method is superior to existing methods or commercial S/W products generating release plans.

구조적으로 유연하고 긴 로봇 매니퓰레이터의 제어를 위한 입력 Shaping 필터링 방법 (Input shaping filtering methods for the control of structurally flexible long-reach manipulators)

  • 황동환;권동수
    • 대한전기학회논문지
    • /
    • 제45권1호
    • /
    • pp.123-130
    • /
    • 1996
  • Due to high payload capacity and high length-to -cross-section ratio requirements, long-reach manipulator systems are expected to exhibit significant structural flexibility. To avoid structural vibrations during operations, various types of input shaping filtering methods have been investigated. A robust notch filtering method and an impulse shaping filtering method were investigated and implemented. In addition, two very different approaches have been developed and compared. One new approach, referred to as a

  • PDF

고 기능성 수질 정화 여과재로서의 장석질 모래 활용연구 (A Study of the Utilization of Feldspathic Sand as a Fortified Functional Filtering Material for Water Purification)

  • 고상모;송민섭;홍석정
    • 한국광물학회지
    • /
    • 제16권4호
    • /
    • pp.283-293
    • /
    • 2003
  • 국내 정수장에서는 여과사를 이용하여 원수를 정수하는 급속 및 완속 여과시스템을 이용하고있다. 대부분의 여과사는 해사인 규사로써, 구성광물의 광물학적 특성이 매우 제한되어 중금속이나 유기 오염물의 여과능력이 높은 편이 아니다. 따라서 항상 예기치 않게 발생될 수 있는 오염된 원수를 효율적이고 경제적으로 여과할 수 있는 여과물질 개발이 요구되고 있다. 따라서 이 연구에서 해사를 대체할 수 있는 화강암 풍화산물인 장석질 모래에 일정량의 불석을 혼화하여 원수를 여과하였을 때 일어나는 지화학성의 변화 및 Cd, Cu, Pb와 같은 중금속의 제거능력을 시험하였다. 시험 대상 물질은 현재 정수장에서 사용하는 주문진 규사와 이 연구에서 제조된 장석질 여과사, 장석질 혼합사 I(불석 10% 혼화), 장석질 혼합사 II(불석 20% 혼화)이다. 장석질 혼합사 I 및 II는 주문진 규사와 장석질 여과사에 비해 대부분의 양이온 및 음이온이 높게 용출되었으며, Si, Ca, $SO_4$ 이온 용출은 Al,$ NO_3$, Fe, K, Mg, P 에 비해 높게 일어났다. 제올라이트의 함량을 높인 혼합사 II가 혼합사 I 비해 Na, Ca, Al과 같은 양이온의 용출농도가 보다 높게 일어났으며, 이 양이온들은 크리높틸로라이트 계열의 제올라이트로부터 주로 용출되었다. 주문진 규사와 장석질 여과사는 Cd, Cu, Pb에 대해 제거능이 거의 없거나 약한 제거율을 보였다. 이에 반하여 장석질 혼합사I, II는 Cd과 Cu에 대해 낮은 제거율을 보였으나 Pb에 대해서는 상대적으로 매우 높은 제거율을 보였다. 장석질 혼합사 I, II는 저농도(100 ppm)의 Cd, Cu, Pb에 대하여 비교적 높은 제거율을 보이는 것으로 나타났으며, 장석질 혼합사 II는 저농도(100 ppm)의 Pb 용액과 반응시킨 경우 상당히 높은 제거율 (90.7%)을 보였다. 고농도(500 ppm) 영역에서는 장석질 혼합사 I, II는 Cd의 흡착량이 Cu, Pb에 비하여 높게 나타났으며, 제거율도 각각 24.0%, 28.2%로 가장 높게 나타났다. 제올라이트의 혼합비가 10%에서 20%로 증가할수록 중금속의 흡착량과 제거율이 향상되었다. 이는 장석질 혼합사를 여과사로 이용 할 경우 제올라이트를 적정 비율로 혼화하면 높은 중금속 제거 효과가 있는 것으로 판단된다.

ESTIMATION OF REQUIRED CAPACITY OF SHUNT TYPE ACTIVE POWER FILTER WITH A THYRISTOR CONVERTER LOAD

  • Jeong, Seung-Gi;Kim, Dong-Ha
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.802-807
    • /
    • 1998
  • The main drawback of parallel type active power filters (APF) is the large capacity required for harmonic compensation. This paper evaluates the APF capacity requirement of harmonic/reactive power compensation for thyristor converter load. Theoretically achievable maximum power factor under partial load is evaluated. And it is shown that the APF capacity can be considerably reduced while slightly sacrificing the filtering performance by deliberately limiting the peak current of the APF.

  • PDF

Ethernet Ring Protection Using Filtering Database Flip Scheme For Minimum Capacity Requirement

  • Rhee, June-Koo Kevin;Im, Jin-Sung;Ryoo, Jeong-Dong
    • ETRI Journal
    • /
    • 제30권6호
    • /
    • pp.874-876
    • /
    • 2008
  • Ethernet ring protection is a new technology introduced in ITU-T Recommendation G.8032, which utilizes the generic Ethernet MAC functions. We introduce an alternative enhanced protection switching scheme to suppress penalty in the switching transient, in which the Ethernet MAC filtering database (FDB) is actively and directly modified by information disseminated from the nodes adjacent to failure. The modified FDB at all nodes are guaranteed to be consistent to form a complete new ring network topology immediately. This scheme can reduce the capacity requirement of the G.8032 by several times. This proposed scheme can be also applied in IP protection rings.

  • PDF

싸이리스터 컨버터부하에 적용되는 병렬형 능동필터의 적정용량산정 (Capacity Requirement Estimation of Shunt Active Power Filter for Thyristor Converter Load)

  • 박노중;정승기
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제48권12호
    • /
    • pp.715-726
    • /
    • 1999
  • This paper estimates the capacity of shunt type active power filters(APF) for harmonic/reactive power compensation with a thyristor converter load. The base capacity requirement of APF is defined for idealized converter load current waveform and the effect of commutation overlap on the APF capacity is examined. The APF capacity required for reactive power compensation in addition to the harmonic elimination is estimated to give maximum achievable power factor for various operating condition of the partially-loaded thyristor converter. The method of current limit of APF is introduced, and it is shown that the APF capacity can be considerably reduced by deliberately limiting the peak current while maintaining the filtering performance to meet the level std 519 regulation.

  • PDF

싸이리스터 컨버터부하를 가지는 병렬형 능동전력필터 용량에 관한 연구 (A Study on the capacity of shunt type active power filter with a thyristor converter load)

  • 박노중;정숭기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 F
    • /
    • pp.2470-2474
    • /
    • 1999
  • The main drawback of parallel type active power filters (APFs) is the large capacity required for harmonic compensation. This paper evaluates the APF capacity requirement for harmonic/reactive power compensation for thyristor converter load. Theoretically achievable maximum power factor under partial load is evaluated. it is shown that the APF capacity can be considerably reduced by deliberately limiting the peak current, while maintaining the filtering performance with an acceptable total harmonic current level. the minimum capacity requirement of APF with current limiting is evaluated as a function of the firing angle of thyristor converter and short circuit ratio(SCR).

  • PDF

멀티 플랫폼 환경에서 효율적인 공간 연산을 위한 객체의 근사 표현 기법 (Approximation Methods for Efficient Spatial Operations in Multiplatform Environments)

  • 강구안;김진덕
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2003년도 추계종합학술대회
    • /
    • pp.453-456
    • /
    • 2003
  • 빠른 질의 처리를 요구하는 공간 데이터베이스 시스템은 주로 최소경계사각형을 이용한 여과단계를 수행한 후 후보 객체에 대해 정제 단계를 수행한다. 대부분의 공간 연산은 빠른 여과 단계를 요구하지만, 처리 능력이 떨어지는 단말기에서는 여과율을 높여 정제 단계의 수행 횟수를 줄이는 것이 필수적이다. 그리고 메모리 용량이 부족한 모바일 단말기는 최소경계사각형을 간략히 표현해야 한다. 이 논문에서는 멀티 플랫폼 환경에서 공간 연산의 효율적인 여과 단계를 위한 공간 객체의 다양한 근사 표현 방법을 제안한다. 또한 2차원 공간 색인의 80%이상을 차지하는 최소 경계 사각형 정보를 압축하기 위한 방법을 제안한다. 그리고 표현 용량과 여과 효율 및 여과 처리 속도 측면에서 각 방법의 장단점을 분석한다.

  • PDF

압력식 급속 자동 여과장치의 여과성능 평가 (The Performance Estimation of Pressure-Type Rapid Automatic Filter)

  • 김덕진;유해성;신상윤
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.607-612
    • /
    • 2006
  • A pressure-type rapid automatic filter of 2000mm diameter and 170 ton/h filtering capacity was fabricated. In case of no external impurity inflow, the turbidity removal efficiency on raw water was experimented and the numbers of impurities of each sizes were analyzed by particle counter. As the result of circulated filtering, the raw water of 40 NTU was filtered to 0.44 NTU and the numbers of impurities above $1{\mu}m$ were removed by approximately 95%. With the filtering efficiency experimented and the mathematical method, the turbidity change of circulation water were calculated according to the inflow rate of external impurity and water treatment method of blow-down or filtering. The cost of blow-down water was calculated from above results. And simple payback period for this filter is calculated as about one year. Nowadays, as the cost of water is continuously increasing and environment regulations will be more strict, the water quality control using this filter will be expected to satisfy the user requirement.

  • PDF

공기주입 이중피복 플라스틱온실의 공기주입장치 설계를 위한 기초실험 (Fundamental Experiments for Design of Air Inflating Apparatus of Air-Inflated Double-Layer Plastic Greenhouse)

  • 이현우;남효석;심상연;남상운;김영식
    • 한국농공학회논문집
    • /
    • 제51권5호
    • /
    • pp.19-24
    • /
    • 2009
  • This study was conducted to provide fundamental data for design of air inflating apparatus of air-inflated double-layer plastic greenhouse. The variation of static pressure in air tube for different fans and filters, filtering performance for various kinds of filters and destruction phase of experimental greenhouse collapsed by excessive static pressure in air space were analyzed. The general type of forward centrifugal fan was recommended for inflating air space in air-inflated double-layer plastic greenhouse. The experimental greenhouse was collapsed down by excessive static pressure just like fallen by heavy snow load acting on it. The static pressure in air tube without filter decreased linearly as the number of outlet openings increased. But the pressure in air tube with filter declined quadratically, the decremental ratio diminished by the increase of outlet openings. The higher filtering efficiency and the greater decrements of static pressure in air tube, the larger capacity fan was required for maintaining proper static pressure in air space. Because the porosities of filter were blocked by dust as time goes by, the static pressure in air tube with filter decreased. The higher filtering efficiency, the less decremental ratio of static pressure in air tube as time passes by. Considering the filtering efficiency, decrement of static pressure and thickness of filter, the 5mm thickness filter of 75% efficiency was recommended for air inflating filter of air-inflated double-layer plastic greenhouse.