• Title/Summary/Keyword: Filter efficiency

Search Result 1,510, Processing Time 0.03 seconds

Performance Prediction of a Grease Filter for Kitchen Ventilation (주방환기용 그리스 필터의 성능예측)

  • Kim Ki-Jung;Bae Gwi-Nam;Kim Youngil;Hur Nahmkeon
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.313-316
    • /
    • 2002
  • A grease filter is used to remove grease generated from a cooking appliance in a kitchen. This numerical study has been conducted to investigate the particle collection characteristics of a grease filter having nominal flowrate of $100m^{3}/h$. The flow field and particle trajectories in the grease filter with a flow chamber were simulated by using the commercial code of STAR-CD. The pressure drop of a grease filter rapidly increases with increasing the air flowrate. The numerical values of the pressure drop are slightly lower than the experimental values when the air flowrates are 50, 75, and $100m^{3}/h$. The particle collection efficiency of a grease filter increases with increasing the particle diameter and the air flowrate, which means that the inertial impaction is a dominant particle removal mechanism in a grease filter The cut-off diameter of the tested grease filter representing $50-{\%}$ collection efficiency is about $11.6{\mu}m$ for water droplets at $100m^{3}/h$.

  • PDF

Experimental Study on Synthetic Fiber Filled Channel for Treating Turbid Water at the Construction Sites and Protecting Drain System (합성섬유 충진 여과수로를 이용한 건설사업장의 흙탕물 처리 및 배수구 보호에 관한 실험적 연구)

  • Yuan, Qingke;Cheng, Jing;Park, Kisoo;Kim, Youngchul
    • Journal of Korean Society on Water Environment
    • /
    • v.32 no.6
    • /
    • pp.537-545
    • /
    • 2016
  • In order to cope with the new and strict government regulations for turbid water discharge from construction sites, this study tested whether synthetic fiber filters can replace conventional best management practices. The filter efficiency was about 10 to 60% with a varying filter depth of 5 to 15cm, presuming extreme storm flow conditions to be in the range of 800 to 1500m/day of filtration rates. Fiber filter acts exactly like a granular filter, i.e. the separation efficiency is directly and inversely proportional to filter depth and rate, respectively. Based on the operational data, we suggested the Log-Log design relationship, which can be used to determine the filter depth and area. Compared to the widely used gravel filter which treats the turbid water at the construction site, about 20% higher efficiency was obtained under similar operating conditions. Cleaning the filter through a simple hand-washing method at the time of break-through, achieved about 90% soil recovery.

Classification of Nanoparticles by Inertial/Diffusion Filter (관성/확산필터를 이용한 나노입자의 분류기술 연구)

  • Kim, Yonggu;Lee, Sangyul;Kim, Hannah;Noh, Hakjae;Bong, Choonkeun;Kim, Daesung
    • Particle and aerosol research
    • /
    • v.11 no.2
    • /
    • pp.29-36
    • /
    • 2015
  • The purpose of this research is to find out the collection property of nanoparticle in diffusion filter to know particle size dispersion of nanomaterial using inertial force and principle of Brownian diffusion motion. We used inertial filters which are two different type and diffusion filters made by various kinds of Wiremesh and the different pieces of filter to compare with particle size distribution using NaCl particles. Finally, We made a conclusion as follows : (1) the bigger available charging volume is and the larger specific surface area of inertial filter is, the better collection efficiency is. (2) The higher wire-mesh number of filter is, the more collection efficiency of small particle is increasing because the wire of the higher Wiremesh number filter is thinner and denser. (3) The more pieces of wire-mesh filter, the more collection efficiency is increasing because it makes the residence time longer.

A Study on Improving Filter Performance Using Coanda Effect (코안다효과를 이용한 필터에 관한 연구)

  • Kim, Yong Sun;Seok, Jae Jun;Shin, Hee Jae;Ko, Sang Cheol
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.19 no.3
    • /
    • pp.99-104
    • /
    • 2020
  • Modern people spend a lot of time indoors. Oil mist has a very fatal effect on the cook's health. Range Hood's filter plays a very important role in removing oil mist from kitchen. In this study, we applied coanda effect to increase the collection efficiency of filter. Original, Bottom, Slide Three shapes were simulated, and the two shapes were measured and compared using a wind tunnel tester. Pressure loss is measured below 2.0mmAq for all three filters, making them easy to use indoors. The simulation results were 15% for the original filter, 22% for the bottom filter, and 30% for the slide filter. The wind tunnel tester obtained 26% of the original filter and 30% of the slide filter. Research is needed to increase the collection efficiency by 50%.

Development of mass aerosol particle generator and fabrication of commercial anti-viral air filter (대용량 입자 발생 장치 개발 및 이를 이용한 항바이러스 공조용 공기필터 제조)

  • Park, Dae Hoon;Joe, Yun Haeng;Hwang, Jungho
    • Particle and aerosol research
    • /
    • v.12 no.4
    • /
    • pp.151-159
    • /
    • 2016
  • Since airborne viruses have been known to aggravate indoor air quality, studies on development of anti-viral air filter increase recently. In this study, a mass aerosol particle generator for coating a commercial air filter (over $300{\times}300mm^2$) was built, and evaluated by comparing a commercial particle generator. Then, via this device, a commercial air filter was coated with anti-viral material ($SiO_2-Ag$ nanoparticles in this study), so fabrication of commercial anti-viral air filter was performed and the pressure drop, filtration efficiency, and anti-viral ability of the filter were evaluated against aerosolized bacteriophage MS2 in a continuous air flow condition. The result showed that the particle generation of the new generator was more than about 8.5 times over which of the commercial one. Consequently, $SiO_2-Ag$ particle coating on a filter does not have significant effects on the filtration efficiency and pressure drop with different areas, and the average anti-viral efficiency of the $SiO_2-Ag$ filter was about 92% when the coating areal density was $1.0{\times}10^{12}particles/m^2$.

A Numerical Study on the Particle Collection Characteristics of a Grease Filter for Kitchen Ventilation (주방환기용 그리스 필터의 입자포집 특성에 관한 수치해석)

  • 김기정;배귀남;김영일;허남건
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.10
    • /
    • pp.792-800
    • /
    • 2002
  • A grease filter is used to remove grease generated from a cooking appliance in a kitchen. This numerical study has been conducted to investigate the particle collection characteristics of a grease filter having nominal flowrate of $100m^3$/h. The flow field and particle trajectories in the grease filter with a flow chamber were simulated by using the commercial code of STAR-CD. The air velocity and pressure distributions were discussed in detail. The pressure drop of a grease filter rapidly increases with increasing the air flowrate. The numerical values of the pressure drop are slightly lower than the experimental values when the air flowrates are 50, 75, and 100㎥/h. The particle collection efficiency of a grease filter increases with increasing the particle diameter, the particle density, and the air flowrate, which means that the inertial impaction is a dominant particle removal mechanism in a grease filter. The cut-off diameter of the tested grease filter representing 50-% collection efficiency is about 11.6$\mu$m for water droplets at $100m^3$/h.

Optimal Design of Notch Filter in Photovoltaic Inverter (태양광 인버터의 노치 필터 최적 설계)

  • Kim, Yong-Rae;Heo, Cheol-Young;Lee, Young-Kwoun;Choy, Ick;Choi, Ju-Yeop
    • Journal of the Korean Solar Energy Society
    • /
    • v.39 no.2
    • /
    • pp.81-92
    • /
    • 2019
  • When Photovoltaic inverter is connected to grid and used as PVPCS (Photovoltaic Power Conditioning System), 120 Hz AC ripple occurs at the dc-link capacitor voltage. This AC ripple reduces the efficiency of PVPCS and shortens the lifetime of the capacitor. In this paper, we design a notch filter to remove AC ripple. As a result, the AC voltage ripple was removed from the dc link and the THD of the PVPCS output current with the notch filter was lowered. This notch filter is determined by the damping coefficient, the bandwidth coefficient, and the switching frequency. Among these, the switching frequency determines the switching loss and the size of the LC filter, and the PVPCS with the high switching frequency has a greater efficiency loss due to the switching loss than the efficiency improvement by the notch filter. Therefore, it is important to set the optimum switching frequency in the PVPCS with the notch filter applied. In this paper, THD and switching loss of PVPCS output current with notch filter are calculated through simulation, and cost function to calculate optimum switching frequency through data is proposed.

Fundamental Experiments for Design of Air Inflating Apparatus of Air-Inflated Double-Layer Plastic Greenhouse (공기주입 이중피복 플라스틱온실의 공기주입장치 설계를 위한 기초실험)

  • Lee, H.W.;Nam, H.S.;Sim, S.Y.;Nam, S.W.;Kim, Y.S.
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.51 no.5
    • /
    • pp.19-24
    • /
    • 2009
  • This study was conducted to provide fundamental data for design of air inflating apparatus of air-inflated double-layer plastic greenhouse. The variation of static pressure in air tube for different fans and filters, filtering performance for various kinds of filters and destruction phase of experimental greenhouse collapsed by excessive static pressure in air space were analyzed. The general type of forward centrifugal fan was recommended for inflating air space in air-inflated double-layer plastic greenhouse. The experimental greenhouse was collapsed down by excessive static pressure just like fallen by heavy snow load acting on it. The static pressure in air tube without filter decreased linearly as the number of outlet openings increased. But the pressure in air tube with filter declined quadratically, the decremental ratio diminished by the increase of outlet openings. The higher filtering efficiency and the greater decrements of static pressure in air tube, the larger capacity fan was required for maintaining proper static pressure in air space. Because the porosities of filter were blocked by dust as time goes by, the static pressure in air tube with filter decreased. The higher filtering efficiency, the less decremental ratio of static pressure in air tube as time passes by. Considering the filtering efficiency, decrement of static pressure and thickness of filter, the 5mm thickness filter of 75% efficiency was recommended for air inflating filter of air-inflated double-layer plastic greenhouse.

Development and efficiency of filter device for the emission reduction from the diesel engine in fishing boat (어선용 디젤엔진의 배출가스 저감 필터 개발과 저감 효율)

  • Lee, Kyounghoon;Kim, Sang-Keun;Kim, Seonghun;Yang, Yong-Su;Park, Seong-Wook
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.50 no.1
    • /
    • pp.50-57
    • /
    • 2014
  • The performance of five kind adsorbents, which can reduce nitrogen oxide (NOx) from the diesel engine occupying 85% of the fishing boat, was carried out and the emission reduction filter was manufactured and evaluated in the adsorption efficiency of the emission gas for 240 KW diesel portable generator. As a NOx emission filter made of mordenite which has an excellent cation exchange capacity was manufactured by ball type adsorbents having excellent specific surface area. The adsorption efficiency of mordenite material applying the emission reduction filter began to show up at the operating time 10 minutes in comparison with the activated carbon and zeolite materials, and it was exposed to continue until 100% capability with passing by 20 minutes. So the adsorption efficiency of the NOx reduction filter consistently maintained at the averaged 80%.

Prediction of collection performance for a granular bed filter filled with various shapes of packing material (다양한 형상의 충전물로 채워진 충전층 집진기의 집진성능 예측)

  • Jae-Hyun Park;Myong-Hwa Lee
    • Particle and aerosol research
    • /
    • v.19 no.4
    • /
    • pp.145-154
    • /
    • 2023
  • Granular bed filters are widely used to remove particulate matter in flue gas and are filled with various shapes of packing material. The packing material plays an important role in determining the overall collection performance, such as pressure drop and collection efficiency. The pressure drop of a granular bed filter has been calculated using the Ergun equation, while the collection efficiency has been predicted using the log-penetration equation based on the single sphere theory. However, a prediction equation of collection efficiency for a granular bed filter filled with non-spherical packing materials has not been suggested yet. Therefore, in this study, three different shapes of packing materials (sphere, cylinder, and irregular) were prepared to propose a prediction equation. The pressure drop and collection efficiency in a granular bed filter filled with each shape of packing material were measured experimentally and compared with theoretically predicted values. We found that experimentally measured pressure drops matched well with values theoretically predicted using the Ergun equation considering the shape factor. However, experimental collection efficiencies were higher than theoretical ones predicted by the log-penetration equation using the single sphere theory. We modified the log-penetration equation by employing a shape factor and found a good relationship between experimental and theoretical collection efficiencies.