• Title/Summary/Keyword: Filter efficiency

Search Result 1,510, Processing Time 0.029 seconds

Performance Comparison of a Fabric Filter System with Centrifugal Force and a Conventional Fabric Filter System (원심력이 적용된 여과포집진장치와 기존 집진장치의 성능비교)

  • Kim Sang-Do;Park Young-Ok;Kang Yong
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.20 no.6
    • /
    • pp.739-748
    • /
    • 2004
  • A hybrid dust-collector combining a fabric filter with centrifugal force was developed to enhance the performance of the conventional fabric filter systems and its performances were evaluated to compare to that of the existing dust collector. The pressure drop rapidly increased with increasing the elapsed time and the face velocity in two filtration systems. But the increasing ratio of a hybrid dust-collector compare to the existing dust collector was lower. This results were confirmed from the performance such as cleaning interval, residual pressure drop and dust loading rate. The overall collection efficiency of the hybrid dust-collector was more than 99.6% and this showed a improvement of 0.6~2% than that of the existing dust collector. Especially, the fractional collection efficiency at the particle size of around 1${\mu}{\textrm}{m}$ is about 4% higher than that of the existing dust collector.

Electric Collection Filter for Ultrafine Dust Removal (초미세먼지 제거를 위한 전기집진 필터에 관한 연구)

  • Kim, Yong Sun;Ko, Sang Cheol
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.21 no.5
    • /
    • pp.40-45
    • /
    • 2022
  • In recent years, indoor air pollution has become a crucial environmental problem. Hence, the purification of indoor air is an important issue. Typical physical filters show relatively high dust collection efficiency at a dust particle size of more than 5.0 ㎛ but extremely low efficiency at an ultrafine size of less than 2.5 ㎛. In this study, an electric field filter was proposed to capture ultrafine dust with a size of less than 5.0 ㎛. Simulation results showed that the electric field filter effectively removed ultrafine dust. In addition, sufficient dust collection efficiency was obtained even with a simple plate-shaped filter without bending the Chevron filter.

Collection Performance of an Electret Cabin Air Filter for Fine Particles (승용차용 정전 필터의 미세 입자 포집 특성)

  • Ji, Jun-Ho;Gang, Seok-Hun;Kim, Dong-Cheol;Hwang, Jeong-Ho;Yun, Ung-Seop;Bae, Gwi-Nam
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.11
    • /
    • pp.1650-1658
    • /
    • 2001
  • An electret filter is composed of permanently charged electret fibers and is widely used in applications requiring high collection efficiency and low-pressure drop. In this work, the fractional collection efficiency of the filter media used in manufacturing cabin air filters was investigated by using highly monodisperse particles ranging from 0.02 to 0.6 $\mu\textrm{m}$ in diameter at three different charging states: singly charged, uncharged, and equilibrium charged. The face velocity was varied from 2.4 to 20.4 crus. It was fecund that the fractional efficiency curve fur singly charged particles shows a typical trend that the collection efficiency is minimum at about 0.3 $\mu\textrm{m}$ in diameter. The fractional efficiency of equilibrium charged particles were not severely varied with the particle diameter. The collection efficiency curve fur uncharged particles has a minimum near 0.1 $\mu\textrm{m}$ in diameter. Another experiment was conducted for a cartridge filter to examine the effect of charge depletion on the collection efficiency in a cabin air filter. The result shows that the charge depletion of the cartridge filter can significantly lower the collection efficiency.

Investigation of Characteristics of Electrostatic Bag Filter with Discharge Electrode Shapes and Filter Properties (방전극 형상 및 여과재에 따른 정전 여과집진장치특성에 관한 연구)

  • 김정일;여석준
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.14 no.3
    • /
    • pp.237-250
    • /
    • 1998
  • In this study, the characteristics of electrostatic bag filter to overcome the main problems such as the high pressure drop and low collection efficiency for submicron particles are investigated with the experimental parameters. Especially, the experiment is carried out focusing on collection efficiency and pressure drop change mechanism as a function of discharge electrode shapes and filter properties, including the applied voltages, filtration velocities and particle concentrations, etc . Results show that the collection efficiency is improved over 30% for the fine particle below 1 pm and pressure drop reduction ratio (PDRR) increases in the following order 4 mm screwy > 4 mm square > 4mm round discharge electrodes . For the filter properties, Nomex is more effective than PE under the influence of electrostatic force. Applying 30 kV for a screwy discharge electrode, higher overall collection efficiency is maintained in spite of the increment of filtration velocity over four times (8 m/min) in comparison with that of 2 m/min and PDRR are highly shown over 80o1o with various filtration velocities, 5, 8, 11 m/min.

  • PDF

Evaluation of a Rapid Sand Filter with Surface Wash and Backwash Conditions (정수장 급속여과지 역세척 수위변화와 시간에 따른 세척 효율 평가)

  • Jung, Yong-Jun;Min, Kyung-Sok
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.6
    • /
    • pp.652-656
    • /
    • 2004
  • Both surface wash and backwash are considered as one of the most important methods that can improve the filtration efficiency in the existing water treatment plant. This study has mainly focused on the improvement of filtering efficiency by controlling surface wash and backwash time, and water level before backwash (when drained up to the trough, when drained up to 10 cm above filter bed, and when drained below 10 cm filter bed). Filtration efficiency was shown a little bit of differences depending on the operating conditions like surface wash injection pressure, the distance control between filter bed and the facility, and the types of surface wash. When the water level before backwash was reached up to 10 cm below filter bed after draining, however, the filtration velocity and the turbidity removal efficiency in the filter bed was improved. When the surface wash followed by backwash is longer, it showed a similar result. Because the proper adjustment of surface washing time makes filtration efficiency higher, therefore, it is necessary to set up the backwash time moderately.

Study on Filter Efficiency and Lifetime Enhancement by using Internal Structures (내부구조물을 이용한 필터의 효율 및 수명 상승에 대한 연구)

  • Kim, Ji-Hun;Yoon, Sangwoo;Kwon, Sung-Ho;Sung, Su-Hwan;Bae, Mun-Oh;Kim, Joohan
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.17 no.5
    • /
    • pp.149-154
    • /
    • 2018
  • To improve the efficiency and lifetime of filters, we analyze the element distribution at the entrance and exit by using the flow inside a filter, confirming that the internal structure affects the filter efficiency. The flow in the pipe is predicted through computer simulations, and the filtration efficiency of each element is compared through experiments. The efficiency and lifetime of the filter are indirectly improved through the element distribution at the filter outlet according to the internal structure. Because pressure loss from the structure inevitably occurs, the efficiency and lifetime of filters against pressure loss must be considered.

A Numerical Study on the Design of a Grease Filter for Kitchen Ventilation (주방환기용 그리스 필터의 형상설계에 관한 수치해석)

  • 김기정;배귀남;김영일;허남건
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.8
    • /
    • pp.619-629
    • /
    • 2003
  • A grease filter is used to remove grease generated from a cooking appliance in a kitchen. Since the inertial impaction is a dominant particle removal mechanism of the grease filter, the performance of the filter is greatly affected by the geometry. This numerical study has been conducted to investigate the effect of geometry on the performance of grease filters for four models having nominal flowrate of 100 m$^3$/h. Four models were designed by changing the shape of impaction surface, the length of eyelid, and the number of eyelids of the grease filter. The flow field and particle trajectories in the grease filter with a flow chamber were simulated using the commercial code of STAR-CD. The difference of air velocity and pressure distributions among four models was discussed in detail. The collection efficiency curves and the pressure drops of four models were also compared. It was found that the grease filter model with flat top surfaces shows highest performance among four models, having high particle collection efficiency and relatively low pressure drop. The cutoff diameter of this model representing 50-% collection efficiency is about 7.1 ${\mu}{\textrm}{m}$ for water droplets at 100 m$^3$/h.

Performance and reusability of certified and uncertified face masks (보건용 마스크 초미세먼지 제거 성능 평가 및 재사용 연구)

  • Lee, Haebum;Kim, Seojeong;Joo, HungSoo;Cho, Hee-joo;Park, Kihong
    • Particle and aerosol research
    • /
    • v.15 no.4
    • /
    • pp.191-202
    • /
    • 2019
  • In this study, performance (particle removal efficiency and breathing resistance) of several commercially available face masks (electrostatic filter masks (KF80 certified), a nanofiber filter mask (KF80 certified), and an uncertified mask) with their filter structure and composition were evaluated. Also, effects of relative humidity (RH) of incoming air, water and alcohol exposure, and reusability on performance of face masks were examined. Monodisperse and polydisperse sodium chloride particles were used as test aerosols. Except the uncertified mask filter, PM2.5 removal efficiency was found to be higher than 90%, and the nanofiber filter mask had the highest quality factor due to the low pressure drop and high removal efficiency (nanofibers were arranged in a densely packed pore structure and contained a significant amount of fluorine in addition to carbon and oxygen). In the case of the KF80 certified mask, the removal efficiency was little affected when the RH of incoming air increased. When the mask filters were soaked in water, the removal efficiency of mask filters was degraded. In particular, the uncertified mask filter showed the highest removal efficiency degradation (26%). When the mask was soaked in alcohol, the removal efficiency also decreased with the greater degree than the water soaking case. The nanofiber mask filter showed the strongest resistance to alcohol exposure among tested mask filters. During evaluation of reusability of masks in real life, the removal efficiency of certified mask filter was less than 4% for 5 consecutive days (2 hours per day), while the removal efficiency of uncertified mask filter significantly decreased by 30% after 5 days.

Bandwidth - Power Optimization Methodology for SFB Filter Design

  • Shin, Hun-Do;Ryu, Seung-Tak
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.12 no.1
    • /
    • pp.88-98
    • /
    • 2012
  • In this paper, the relationship between the bandwidth (BW) and power efficiency of a source follower based (SFB) filter is quantitatively analyzed, and a design methodology for a SFB filter for optimized BW - power consumption is introduced. The proposed design methodology achieves a maximum BW at a target quality (Q) factor for the given power consumption constraint by controlling design factors individually. In order to achieve the target BW from the maximized BW, a tuning method is introduced. Through the proposed design methodology, a fourth order Butterworth filter was implemented in 0.18 ${\mu}m$ CMOS technology. The measured BW, power consumption, and IIP3 are 100 MHz, 33 ${\mu}W$, and 9 dBm, respectively. Compared with other filter structures, the measured results show high BW - power efficiency.

Performance of Respirator Filters Using Quality Factor (qF) (양질계수(Quality Factor)를 이용한 방진마스크 필터의 성능평가)

  • Han, Don-Hee;Jeong, Yoon-Sok
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.10 no.1
    • /
    • pp.170-178
    • /
    • 2000
  • Most of manufacturers try to produce the most efficient filter for respirators with the lowest breathing resistance. Filter performance depends on low penetration, i.e., high efficiency (%), and low pressure drop ($mmH_2O$). This study was performed to evaluate performance of respirator filters by quality factor ($q_F$) and suggest the direction for improvement of respirator filters of good quality in Korea. Two mechanical filters, S and K made in Korea, three filtering facepieces, S made in China, C made in Korea and M made in USA, which were widely used in the workplace, were selected and tested efficiency and pressure drop in accordance with flow rate, using with Automated Filter Tester Model 8110 (TSI, USA). The best quality factor within the same respirator filter categories was $0.0672cm^{-1}\;H_2O$ for mechanical filter S, $0.0698cm^{-1}\;H_2O$ for filtering facepiece M at flow rate of 32Lpm. Mechanical filter S would be the best suitable during heavy work since qulity factors decrease less sharply than any others as increased flow rates. It was necessary for mechanical filter S to lower pressure drop without increasing efficiency, but mechanical filter K should be increased efficiency and decreased pressure drop. While filtering facepiece M had the best quality performance of three ones, Sand C should get much higher efficiency and lower pressure for better performance.

  • PDF