• 제목/요약/키워드: Film Therapy

Search Result 243, Processing Time 0.023 seconds

A Case of Acute Respiratory Failure Presenting Lobar Consolidation (대엽성 폐경화로 나타난 급성 호흡부전 1예)

  • Shin, Tae-Rim;Maeng, Sun-Hee;Lee, Hyun-Kyung;Kim, Hae-Young;Chang, Jung-Hyun
    • Tuberculosis and Respiratory Diseases
    • /
    • v.45 no.3
    • /
    • pp.654-660
    • /
    • 1998
  • Pulmonary embolism is one of the moot common acute pulmonary disease in the adult general hospital population However, the disease is still frequently unsuspected and underdiagnosed due to the nonspecificity of both clinical findings and laboratory tests. The chest radiography in a patient suspected acute pulmonary embolism do not provide adequate information to establish or exclude the diagnosis of pulmonary embolism. Even in the case of infarction, there is no pathognomonic clues on the chest film. Rarely infarction presents unusual roentgenologic manifestation such as lobar consolidation, coin lesion, multinodular opacity, or massive pleural effusion Especially, lobar consolidation in pulmonary embolism might mislead into the diagnosis of pneumonia. We experienced a case of pulmonary embolism presenting lobar consolidation in a 62 years old woman, originated from deep vein thrombosis. She took a compression stocking and underwent anticoagulant therapy with excellent outcome.

  • PDF

A Clinical Study of Cavernoplasty (공동 성형술에 대한 임상적 검토)

  • 우종수
    • Journal of Chest Surgery
    • /
    • v.11 no.2
    • /
    • pp.147-152
    • /
    • 1978
  • Six patients with pulmonary tuberculosis with cavity had cavernoplasty at Seoul National University Hospital during the last 4 years and 9 months, from October 1973 to April 1978, were studied in order to assess the clinical values of cavernoplasty. 2] All the cases were male, and the mean age was 31.5 years. 2] All the patients had combined therapy with more than two antituberculosis drugs preoperatively, its minimum duration being 8 months and maximum duration 5 years. 2] Nonspecific symptoms were predominant just prior to admission, weight loss being in 50% and loss of appetite in 50% of cases, respectively. The preoperative cavity size on plain film was minimum 2.5cm by 3.5cm and maximum 6.0cm by 4.0cm with the mean of 4. 4cm by 3.4cm. The cavity size was reduced postoperatively to 1/3-1/4 of preoperative size with the mean of 1.15cm by 1.59cm. 2] Sputum smear for acid fast bacilli was converted to negative postoperatively in two cases. 2] Complications occurred in two cases. One was postoperative pleural effusion and the other was recurrence of symptoms 2 years after surgery. 2] Of the 3 cases able to follow, 2 stopped antituberculous medication after one year. The third case was still on medication because of bronchiectasis due to tuberculous infection.

  • PDF

Monte Carlo Simulation of Small Photon Beam Measurements by Beam Intensity Scanner System(BISS)

  • Park, Kwangyl;Vahc, Young-Woo;Ohyun Kwon;Park, Kyung-Ran;Lee, Yong-Ha;Yi, Byung-Yong;Kim, Sookil
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.282-284
    • /
    • 2002
  • We have developed and used BISS as a radiation detector to verify patient dose and determine the physical characteristics of beams used in Stereotatic Radio Surgery(SRS) and Intensity Modulated Radiation Therapy(IMRT). In order to confirm the function and accuracy of our BISS, we simulate our measurements by BISS under the radiation of 6MV photons from a Varian Clinac 21EX equipped with a 60 leaf pairs MLC. For the simulation based on the Monte Carlo algorithm, which remains the most comprehensive and accurate theoretical method to verify beam profiles, we use the BEAM code. Compared with the measurements by BISS, our simulation of variously shaped phantom measurements show good agreements. Our simulation results can be used as a theoretical standard to compare and confirm measurements by BISS and other dosimeters such as ultramicro cylindrical ionization chamber(UCIC) and radiographic film.

  • PDF

A Case of Pneumonia Treated with Combined Eastern-Western Medical Therapy and Hwangkibyulgap-tang (한양방협진 및 황기별갑탕으로 호전된 폐염(肺炎)환자 1례 보고)

  • Jeon, Kwi-Ok;Seo, Young-Ho;Park, Mee-Yeon;Choi, Hae-Yun;Kim, Jong-Dae;Cho, Dong-Hee
    • The Journal of Internal Korean Medicine
    • /
    • v.27 no.4
    • /
    • pp.969-974
    • /
    • 2006
  • This is clinical report of one patient with pneumonia in stroke who improved with the administration of an herb drug. During treatment for stroke, he broke out with pneumonia, a complication of stroke, which was confirmed by chest radiography. He was administrated Hwangkibyulgap-tang with antibiotics because of old age middle stage pneumonia. After administration, the symptoms improved and chest x-ray film showed no pneumonic finding. This result suggests that oriental medicine is an effective treatment for pneumonia but more clinical case reports are needed.

  • PDF

Mediastinitis after Central Venous Catheterization (중심정맥관 삽입후 발생한 종격동염-1례 보고)

  • Keum, Dong Yoon;Park, Nam Hee;Lee, Kee Tae
    • Tuberculosis and Respiratory Diseases
    • /
    • v.58 no.1
    • /
    • pp.64-67
    • /
    • 2005
  • We report here on an uncommon case of mediastinitis that occurred after central venous catheterization. A patient with colon and jejunal cancer complained high fever, right shoulder pain, chest pain, and limited motion of the affected shoulder just 6 days after central venous catheterization. Bacterial culture of the blood, shoulder abscess, and catheter puncture site revealed methicillin-resistent staphylococcus aureus. Right upper mediastinal widening on chest film also suggested mediatinitis. Mediastiotomy and pus drainage was performed along with adequate antibiotics therapy. In this case, it seems that initially formed bacteria from the puncture site migrated to the mediastinum through the tissue plane to start the mediastinitis. Careful dressing of puncture site and correct handling of catheter is important to prevent this serious complication.

Transdermal Permeation of $[{^3}H]Acyclovir$ Using Niosome (니오솜을 이용한 $[^{3}H]$아시클로버의 경피투과)

  • Park, Sae-Hae;Lee, Soon-Young;Yong, Chul-Soon
    • Journal of Pharmaceutical Investigation
    • /
    • v.28 no.1
    • /
    • pp.43-50
    • /
    • 1998
  • Niosomes are vesicles formed from synthetic non-ionic surfactants, offering an alternative to chemically unstable and expensive liposomes as a drug carrier. Non-ionic surfactant and cholesterol mixture film leads to the formation of vesicular system by hydration with sonication method. The formation of niosome was ascertained by negative staining of TEM. The entrapment efficiency of niosomal suspension was gradually increased with increasing the ratio of cholesterol to surfactant. It was found that the niosome with 6 : 4 (polyoxyethylene 2-cetyl ether: cholesterol) ratio was more stable than those with other ratios. The topical application of acyclovir(ACV) in the treatment of herpes simplex virus type 1(HSV-1) skin disease has a long history. There are an increasing number of reports, however, in which topical ACV therapy is not as effective as oral administration. Lack of efficacy with topical ACV has been hypothesized to reflect the inadequate delivery of drug to the skin. We investigated the permeation of niosome containing $[^{3}H]ACV$ in hairless mouse skin using Franz diffusion cell model. Permeation coefficient(P) of aqueous ACV was $6.7{\times}10^{-4}\;(cm/hr)$ and that of ACV in niosome was $23.4{\times}10^{-4}\;(cm/hr)$, suggesting about 3.5 times increase in the transdermal permeation.

  • PDF

Congenital Esophageal Atresia with Tracheoesophageal Fistula -A Case Report- (선천성 식도폐쇄 및 기관식도루 -1례 보고-)

  • Lee, Mun-Geum;Jang, Un-Ha
    • Journal of Chest Surgery
    • /
    • v.27 no.6
    • /
    • pp.489-493
    • /
    • 1994
  • Our patient was a 2.3 kg, male of 33 weeks gestation and spontaneous vaginal delivery. Copious salivary secretion, mild aspiration pneumonia episode due to tracheoesophageal fistula and intermittent cyanotic appearance due to hypoxia were noted shortly after birth. Head up position, frequent upper pouch suction, and adequate fluid and antibiotic therapy were done in incubator. Combined Chest and abdominal film was revealed gas in the stomach and an haziness in right chest with mediastinal shift to the right side. Esophagogram revealed markedly dilated proximal esophagus as blind pouch, and Two dimensional echocardiography showed the Ventricular Septal Defect. The conclusion was congenital esophageal atresia with tracheoesophageal fistula, Vogt-Gross type C, Waterston Risk Category B. Surgical correction with Beardmore anastomosis was performed extrapleurally through 3rd rib bed after the cannulation of umbilical vein and preliminary gastrostomy. The fistula was closed by triple ligation and the upper pouch was then brought down to the presenting surface of the lower esophageal segment that incised, and end to side anastomosis was underwent using interrupt suture placed through the full thickness of both upper pouch and lower esophageal segment. The postoperative patient was well tolerated and recovered uneventfully, permitted feeding on 7th postoperative day after esophagogram.

  • PDF

Verification of skin dose according to the location of tumor in Tomotherapy (토모테라피 시 종양의 위치에 따른 피부선량 검증)

  • Yoon, Bo Reum;Park, Su Yeon;Park, Byoung Suk;Kim, Jong Sik;Song, Ki Won
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.273-280
    • /
    • 2014
  • Purpose : To verify the skin dose in Tomotherapy-based radiation treatment according to the change in tumor locations, skin dose was measured by using Gafchromic EBT3 film and compared with the planned doses to find out the gap between them. Materials and Methods : In this study, to measure the skin dose, I'm RT Phantom(IBA Dosimetry, Germany) was utilized. After obtaining the 2.5mm CT images, tumor locations and skin dose measuring points were set by using Pinnacle(ver 9.2, Philips Medical System, USA). The tumor location was decided to be 5mm and 10mm away from surface of the phantom and center. Considering the attenuation of a Tomo-couch, we ensured a symmetric placement between the ceiling and floor directions of the phantom. The measuring point of skin doses was set to have 3mm and 5mm thickness from the surface. Measurement was done 3 times. By employing TomoHD(TomoHD treatment system, Tomotherapy Inc., Madison, Wisconsin, USA), we devised Tomotherapy plans, measured 3 times by inserting Gafchromic EBT3 film into the phantom and compared the measurement with the skin dose treatment plans. Results : The skin doses in the upper part of the phantom, when the tumor was located in the center, were found to be 7.53 cGy and 7.25 cGy in 5mm and 3mm respectively. If placed 5mm away from the skin in the ceiling direction, doses were 18.06 cGy and 16.89 cGy; if 10mm away, 20.37 cGy and 18.27 cGy, respectively. The skin doses in the lower part of the phantom, when the tumor was located in the center, recorded 8.82 cGy and 8.29 cGy in 5mm and 3mm, each; if located 5mm away from the lower part skin, 21.69 cGy and 19.78 cGy were respectively recorded; and if 10mm away, 20.48 cGy and 19.57 cGy were recorded. If the tumor was placed in the center, skin doses were found to increase by 3.2~17.1% whereas if the tumor is 5mm away from the ceiling part, the figure decreased to 2.8~9.0%. To the Tomo-couch direction, skin doses showed an average increase of 11% or over, compared to the planned treatment. Conclusion : This study found gaps between planned skin doses and actual doses in the Tomotherapy treatment planning. Especially to the Tomo-cocuh direction, skin doses were found to be larger than the planned doses. Thus, during the treatment of tumors near the Tomo-couch, doses will need to be more accurately calculated and more efforts to verify skin doses will be required as well.

A study on the accuracy of source position in HDR brachytherapy according to the curvature of Universal applicator transfer tube and applicator type (원격 후 장전치료기를 사용한 고선량률 근접치료시 기구의 형태와 선원 전달 도관의 곡률 변화에 따른 선원위치 정확성에 관한 고찰)

  • Shin, Hyeon Kyung;Lee, Sang Kyoo;Kim, Joo Ho;Cho, Jeong Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.2
    • /
    • pp.123-129
    • /
    • 2015
  • Purpose : The goal of this study was to verify and analyze the source position according to the curvature of the universal applicator and 4 different angle applicators when using RALS(Remote After Loading System). Materials and Methods : An interval of 1 cm and 15 second dwell times in each source position were applied for plan. To verify the accuracy of source position, we narrowed the distance between MultiSource container and GAFCHROMIC$^{(R)}$ EBT3 film by 5 cm, 10 cm, 20 cm so that the universal applicator transfer tube had some curvature. Also 4 applicators(Intrauterine tube: $0^{\circ}$, $15^{\circ}$, $30^{\circ}$, Ovoid tube: $65^{\circ}$) were used in the same condition. The differences between desired and actual source position were measured by using Image J. Results : In case of using 4 different angles of applicator with the straight universal applicator transfer tube, the average error was the lowest for $0^{\circ}$ applicator, greatest for $65^{\circ}$ applicator. However, All average errors were within ${\pm}2mm$ recommended in TG-56. When MultiSource container was moved 5 cm, 10 cm, 20 cm towards the EBT3 film, the average errors were beyond ${\pm}2mm$. The first dwell position was relatively located in accuracy, while the second and third dwells were displaced by an increasing magnitude with increasing curvature of the transfer tube. Furthermore, with increasing the angle of applicators, the error of all other dwell positioning was increased. Conclusion : The results of this study showed that both the curvature of universal applicator transfer tube and the angle of applicators affect the source dwell position. It is recommended that using straight universal applicator transfer tubes is followed in all cases, in order to avoid deviations in the delivered source dwell position. Also, It is advisable to verify the actual dwell position, using video camera quality control tool prior to all treatments.

  • PDF