• 제목/요약/키워드: Filling level

검색결과 363건 처리시간 0.026초

열연화시킨 근관충전방법에 따른 근단폐쇄성에 관한 연구 (A COMPARISON OF THE APICAL SEALING ABILITY OF OBTURATION TECHNIQUES BY THERMALLY SOFTENED GUTTA PERCHA)

  • 백승호
    • Restorative Dentistry and Endodontics
    • /
    • 제23권2호
    • /
    • pp.607-617
    • /
    • 1998
  • The purpose of this study was to evaluate the apical sealing ability of lateral condensation method, vertical condensation method, and MicroSeal obturation system. Sixty-four extracted anterior teeth were instrumented to #40 using Profile. Three groups of 20 teeth were obturated by lateral condensation technique, vertical condensation technique, and and MicroSeal obturation system. Control group were not obturated. Teeth were immersed in resorcinol-formaldehyde resin for 5 days at $4^{\circ}C$, and the resin was allowed to polymerize completely for 4 days at room temperature. Teeth were ground horizontally at 1,5mm(level 1), 2.5mm(level 2), and 3.5mm(level 3) from the anatomic apex and examined with a stereomicroscope at X40 magnification. The photographs were taken a at X40 magnification of the filling in each level and scanned. The leakage area, which was filled with the resin, was measured at each of the three levels. Each ratio of leakage was evaluated by calculating the ratio of thearea of the resin to the total area of the canal and was analyzed statistically. The results were as followed: 1. Vertical condensation group had significantly higher percentage of the area which was obturated by gutta percha than other two technique at each level. 2. At the level 1, there was the greatest leakage in the lateral condensation group, but there was no statistically significant(P>0.05) 3. At the level 2, there was the least leakage in the MicroSeal group, and the most leakage in the lateral condensation group. There was statistically significant difference between the MicroSeal group and the lateral condensation group(P<0.05). 4. At the level 3, there was least leakage in the vertical condensation group, and the most leakage in the lateral condensation group. There was statistically significant difference between the vertical condensation group and the lateral condensation group(P<0.05).

  • PDF

Orthodontic treatment for maxillary anterior pathologic tooth migration by periodontitis using clear aligner

  • Lee, Jun-Woo;Lee, Sang-Joon;Lee, Chang-Kyu;Kim, Byung-Ock
    • Journal of Periodontal and Implant Science
    • /
    • 제41권1호
    • /
    • pp.44-50
    • /
    • 2011
  • Purpose: Pathologic tooth migration (PTM) is a tooth displacement which is derived from imbalance of tooth retention force and is dominantly found out in maxillary anterior area. PTM in maxillary anterior area was tried to corrected with periodontal treatment and a clear aligner in this study and the result was evaluated clinically and radiographically. Methods: For the treatment of a patient with chronic periodontal disease accompanied by maxillary anterior pathologic tooth migration, clear aligner was applied to move teeth after a series of case-related periodontal therapy. Clinically, probing depth, gingival recession, clinical attachment level and mobility were measured pre- and post-treatment, and radiographic examination was performed as well. Results: Clinically, we found the decrease of the probing depth, gingival recession, clinical attachment level and mobility. And we could also acknowledge the reduction of vertical and horizontal dimension on infrabony defect radiographically. However, it is still controversial if there was an actual bone filling. Conclusions: Clear aligner is an effective appliance to move teeth since it costs little in terms of expense and time. In addition, it wraps whole crowns, providing advantages to deal with crowding, spacing, and size of arch. In short, clear aligner could be a useful treatment option for PTM patient, since it provides decreased probing depth, gingival recession, clinical attachment level, mobility and esthetical restoration.

호기말 양압호흡이 혈류역학 및 심기능에 미치는 영향 (Hemodynamic Influences of Positive End-Expiratory Pressure Ventilation in Patients with Pulmonary Insufficiency)

  • 장병철
    • Journal of Chest Surgery
    • /
    • 제18권1호
    • /
    • pp.79-85
    • /
    • 1985
  • The effect of graded increments in positive end-expiratory pressure [PEEP] on hemodynamics required to ventilate 8 critically ill patients is reported. Acute respiratory insufficiency was a cause of death in only one patient of drug inoxication among the 8 patients studied. The cardiac output was not changed significantly after the increment of PEEP to the level of 20 cm H2O. The heart rate was increased significantly from 15 cm H2O PEEP [P<0.01] as compared to 0 cm H2O PEEP; and the stroke volume was decreased significantly from 15 cm H2O PEEP [P<0.05]. The blood pressure was not affected at any level of PEEP, but the pulmonary artery pressure was elevated significantly at 10 cm H2O PEEP [P<0.01]. The right ventricular transmural filling pressure was not affected at the level of 10 cm H2O PEEP, but from 15 cm H2O PEEP it was increased significantly. With the increment of PEEP, the left ventricular stroke work index was decreased slightly; and at 20 cm H2O PEEP, it was decreased significantly. The right ventricular stroke work index was increased only at 10 cm H2O PEEP. The systemic vascular resistance was decreased significantly from 15 cm H2O PEEP [P<0.01].

  • PDF

일부지역 치과위생사의 치과진료실 실내공기질에 대한 만족도 및 자각증상 비교 (The satisfaction and subjective symptom level by indoor air quality in dental parlor in Capital and Jeon-nam area)

  • 최미숙
    • 한국치위생학회지
    • /
    • 제11권3호
    • /
    • pp.405-417
    • /
    • 2011
  • Objectives : A precedent research has documented that indoor air pollution is closely associated with increased the risk of symptom and decreased in job satisfaction. This study was conducted in an effort to assess the relationship of indoor air quality to self-perceived symptom and satisfied with working environment. Methods : This research is based on self-filling survey which 393 dental hygienists who work in seoul and Jeon-nam area participated on October 2010 through January 2011. This survey was compared and analyzed about the level of satisfaction and subjective symptom by the indoor air quality that dental office's working environment. Results : The result of satisfaction degree of hospital working environment was pretty low about office air. Most people mentioned that they were sore and dull all over the back, shoulder, and neck. Also, they were drowsy and exhausted in work place. Conclusions : In conclusion, it is need to improve their quality of life and mental health by developing proper air conditioning system and using one in their work place.

치근단 역충전용 포틀랜드 시멘트 신복합재료의 물리적 성질 고찰 (Physical properties of novel composite using Portland cement for retro-filling material)

  • 이상진;조옥인;염지완;박정길;허복;김현철
    • Restorative Dentistry and Endodontics
    • /
    • 제35권6호
    • /
    • pp.445-452
    • /
    • 2010
  • 연구목적: 이 연구의 목적은 새로운 근단 역충전 재료를 개발하기 위해 MTA, MTA와 AH-plus 혼합물 (AMTA), 그리고 실험적 개발재료인 Portland cement-Epoxy resin composite (EPPC)의 미세 누출 및 물리적인 성질을 비교하는 것이다. 연구 재료 및 방법: 발거 치아 49개를 근관 성형하고 gutta-percha와 sealer로 충전하였다. 각 치아의 치근을 근단부 3 mm에서 절단하고 3 mm 깊이의 역충전 와동을 형성하였다. 15개씩 무작위로 분류한 치근을 세 군으로 나누어 각각 MTA, AMTA, EPPC로 충전하였고 네 개의 치근은 대조군으로 사용하였다. 각 군의 재료로 역충전이 완료된 모든 실험군을 젖은거즈로 덮고 24시간 동안 경화시켰다. 경화 후 72시간 동안 1% methylene blue 염색액에 담근 후, 치근단을 수직 절단하여 사진을 촬영하고 미세 누출을 평가하였다. Vicat apparatus를 사용하여 실험군 별로 경화시간을 측정하였으며, aluminum step wedge를 사용한 디지털 방사선 사진을 촬영하여 각 군의 방사선 불투과도를 평가하였다. 미세누출과 경화시간에 대해 각 군간의 차이를 일원배치분산분석 및 Scheffe 사후 검증으로 유의수준 95%에서 평가하였다. 결과: AMTA와 EPPC는 MTA군에 비해 적은 미세누출량을 보였다 (p < 0.05). AMTA는 가장 높은 방사선 불투과도를 보였으며 개발 재료인 EPPC군은 5 mm aluminum 두께의 방사선 불투과도를 보였다. MTA가 가장 긴 경화시간을 나타낸반면 EPPC군은 다른 군에 비해 초기경화와 최종경화 모두 가장 짧은 경화시간을 나타냈다 (p < 0.05). 결론: 이 연구 조건하에서, 신개발 재료인 EPPC는 치근단 역충전 재료로서 기존의 MTA보다 양호한 밀폐능력과 방사선 불투과성 및 짧은 경화시간 등의 역충전 재료로서 적절한 물리적 성질을 가진 것으로 보인다.

질소시비량에 따른 벼 생리생태적 특성 연구 (Physiological and Ecological Comparison of Rice Cultivars Grown in Low Fertilized Condition)

  • 구홍모;유오종;박종현
    • 현장농수산연구지
    • /
    • 제20권1호
    • /
    • pp.175-185
    • /
    • 2018
  • 개체군생장율(CGR)은 유수형성기와 출수기 사이에 가장 높았는데, 주남벼, 낙동벼, 소비벼 등이 높았으며, 이삭의 등숙속도는 시비량이 증가할수록 증가하였고, 출수 후 20일까지 가장 많이 증가하고, 그 이후에는 점차 감소하는 경향이었는데, 주남벼, 소비벼에서 빨랐다. 관행재배에서 수량이 높은 품종은 소비재배에서도 수량이 높았으며, 소비재배시 수량에 가장 많은 영향을 미치는 수량구성요소는 단위면적당 영화수로, 고도의 정의 상관관계를 나타냈다. 또한 백미품위는 시비량이 증가할수록 감소하였는데, 소비벼의 품위가 가장 낮았으며, 사미와 분상 질립의 증가가 원인이었다.

낙동강 하류 하천구조물 건설 전후의 충적층 지하수위 시계열 특성 비교 (Comparison of Time Series of Alluvial Groundwater Levels before and after Barrage Construction on the Lower Nakdong River)

  • 김규범;차은지;정해근;신경희
    • 지질공학
    • /
    • 제23권2호
    • /
    • pp.105-115
    • /
    • 2013
  • 보의 건설 및 하천 단면의 증가는 하천 수위 상승과 호우기 유출량의 증가를 가져왔다. 낙동강 중하류에 설치된 23개의 지하수 관측망 지하수위 자료를 사용하여 보 담수 전후의 지하수위 시계열 변동 유형의 변화를 분석하였다. 월평균 지하수위 자료를 토대로 담수 전후의 지하수위를 비교한 결과 보의 직상류 주변 지역에서 지하수위 변동이 가장 크게 나타났으며, 8월의 경우 하천 수위 조절 효과로 월평균 지하수위가 0.1 m 감소하였으나 10월에는 1.3 m 상승한 것으로 나타났다. 지하수위 시계열 자료와 하천 수위 자료를 사용하여 군집분석을 실시한 결과, 담수 이전에는 7개 지하수 관측망의 자료가 하천 수위와 유사성 거리가 가까운 그룹이었으나, 담수 이후에는 14개로 증가하여 하천 수위와 유사한 그룹의 범위가 넓어졌다. 지하수위 시계열에 대한 주성분분석 결과, 담수 이전에는 하천 변동성을 대표하는 주성분(주성분 1과 주성분 2)의 설명력이 총 82%이었으나, 담수 이후에는 하천 변동성을 설명하는 주성분(주성분 1)의 설명력이 45%로 줄어들어 지하수위 자료를 설명하는데 하천 요인의 기여도가 줄고 인위적인 양수 등과 같은 기타 요인의 기여도가 높아졌다. 이와 같이 변화되는 수문 환경에 대비하여 지속적인 조사 및 관측이 필요하며, 하천 주변에서는 지표수와 연계되는 지하수 관리 정책이 수립될 필요가 있다.

대기오염에 의한 치과위생사의 자각증상 특성 (A Sbjective Symptom on Outdoor Air Quality in Dental Hygienist)

  • 지동하;최미숙;손부순
    • 환경위생공학
    • /
    • 제22권2호
    • /
    • pp.1-8
    • /
    • 2007
  • This research is based on self-filling survey which 656 dental hygienists who work in, seoul, the metropolitan area, jeon-buk area participated on July 2006 through August 2006. This survey was analyzed the relationship between the subjective symptoms(6 types) and outdoor air quality($O_3,\;NO_2,\;CO,\;SO_2,\;PM_{10}$) As follows analyzed results. The health condition of dental hygienists were "Feel Good" more than 50% in last month. The experience the symptoms level is higher then non-experience level in "Dry eye, itch, smarting", "Headaches", "Fatigue and sleepiness", "Red eye", "Hypersensitivity", "Dorsalgia, omarthralgia, cervicodynia". We anticipated that the more experience the subjective symptom the more likely it is that outdoor air quality will be high rate level. But we could not find the uniformity in metropolitan-area and seoul-area. In the case of jeonbuk area, the group's pollution density levels which experienced the subjective symptom were appeared high rate than inexperienced group except $SO_2$. It probably comes from sensibility for an air pollution in this area. Dental hygienists who work in jeonbuk area have an unusual sensibility for an air pollution because outdoor air quality of jeonbuk area was rule good rather than others area. especially $SO_2$ was revealed out even though low rate level in inexperienced group it is that the number of cars in jeonbuk area is increasing rapidly.

분자선 에피탁시법으로 성장된 $Al_{0.25}Ga_{0.75}As/In_{0.15}Ga_{0.85}As$/GaAs 슈우도형 고 전자 이동도 트랜지스터 구조의 광학적 특성 (The optical characteristics of $Al_{0.25}Ga_{0.75}As/In_{0.15}Ga_{0.85}As$/GaAspseudomorphic high electron mobility transistor structure grown by molecular beam epitaxy)

  • 이동율;이철욱;김기홍;김종수;김동렬;배인호;전헌무;김인수
    • 한국진공학회지
    • /
    • 제9권2호
    • /
    • pp.130-135
    • /
    • 2000
  • Photoluminescence(PL)와 photoreflectance(PR)를 이용하여 $Al_{0.25}/Ga_{0.75}/As/In_{0.15}/Ga_{0.85}$/AS/GaAS 슈우도형 고 전자 이동도 트랜지스터 구조에 대한 특성을 조사하였다. 온도 10K의 PL측정에서 InGaAs 양자우물에 의한 e2-hl 및 e2-hl 전이 피크가 각각 1.322 및 1.397 eV에서 관측되었다. 온도 의존성으로부터 첫번째 가전자 띠와 두번째 가전자 띠의 에너지 차이는 약 23'meV로 나타났다. 또한 300 K에서의 PR 측정으로 e2-h2및 e2-hl 전이에 의한 피크를 관측하였고, 두번째 전도 띠의 에너지 준위에 의한 피크가 띠 채움으로 인해 첫번째 전도 띠의 에너지 준위에 의한 피크보다 상대적으로 우세하였다. 반면에 PL 측정에서는 전자 가리개 효과 때문에 첫번째 전도 띠에 의한 피크가 우세하였다.

  • PDF

댐 비상방류 설계기준 선정을 위한 수리수문학적 검토(II) (Hydraulic & Hydrologic Design Criteria for an Emergency Drainage of Reservoir (II))

  • 이재응;손광익;강민석
    • 한국수자원학회논문집
    • /
    • 제48권3호
    • /
    • pp.159-167
    • /
    • 2015
  • 댐 운영에 있어서 저수지 초기 담수 시 또는 집중호우 등에 의한 급격한 수위 상승 방지나 운영 중에 댐체 점검 및 수리 또는 자연재해로 인한 위급한 상황 발생 등 저수지를 비워야 할 상황이 발생할 수 있으며, 이에 대한 대책으로 비상 시 방류할 계획 및 설비가 필요하다. 그러나 현재 국내에는 이러한 비상방류에 대한 기준이 미비한 실정이다. 본 연구에서는 댐 안정성 제고를 위해 유사시 저수지 저류량을 안전하게 배제시킬 수 있는 비상방류 설비를 저수지 모의 모형인 HEC-ResSim 모형을 이용하여 규모 및 배제일수에 대하여 모의하고 산정하였다. 저수지 규모에 따라 세 개의 댐에 대해 검토하였다. 대상댐은 저류용량을 기준으로 10억 $m^3$ 이상인 소양강댐과 1~10억 $m^3$ 댐으로 합천댐, 1억 $m^3$ 미만의 댐으로 대곡댐을 선정하여, 방류시설의 규모를 산정하고 배제일수를 모의하여 기준의 적정성과 적용 가능성에 대해 검토하였다.