• 제목/요약/키워드: Filling Material

Search Result 736, Processing Time 0.159 seconds

Success and survival rate of the implant with crestal sinus lift using S-reamer and gel-type graft material: A retrospective study by more 5-years follow check up (S-reamer와 겔 형태의 이식재를 이용한 치조정 접근법을 통한 상악동 거상술 임플란트의 성공률과 생존율: 5년 이상 추적 관찰을 통한 후향적 연구)

  • Kim, Jong Jin;Cho, Sung Am
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.58 no.1
    • /
    • pp.23-29
    • /
    • 2020
  • Purpose: The purpose of this retrospective study was to evaluate the method using the S-reamer and gel-type graft material by the success rate and survival rate. Materials and methods: Implantation period was from 2008 to 2014, Follow check up year is 2019. There were 59 patients and 117 implants. All implants were placed in the posterior maxilla with the sinus lift. The patients population consisted of 34 men and 25 women, ranging from 19 to 75 years. The residual bone heights were from 1 mm to 6 mm. Sinus was perforated with S-reamer without membrane tearing and gel type bone graft material was used for membrane lifting and filling the space. all implants were placed simultaneously. Panoramic X-ray was taken. After 5 - 6 months healing period, final prostheses were restored. After more 5-years implant surgery, Panoramic X-ray was obtained and X-ray analysis and clinical examination were performed. Success criteria was referred to a Buser's success critera. All implants were classified to success implant, survival implant, failed implant. A success implant was satisfying success criteria, a survival implant was a implant that was acute infection with suppuration and bone loss, a failed implant was a implant that was mobile, removed. Results: Five implants were removed, and 4 implants had infected with bone loss. Survival rate was 95.7% and success rate was 92.3%. Conclusion: This retrospective study presented that this method with S-reamer and gel-type graft material was a successful treatment without membrane tear in the condition of 1-6 mm residual bone height.

An Evaluation of Soil-Water Characteristic Curve Model for Compacted Bentonite Considering Temperature Variation (온도 변화를 고려한 압축 벤토나이트 완충재의 함수특성곡선 모델 평가)

  • Yoon, Seok;Jeon, Jun-Seo;Go, Gyu-Hyun;Kim, Geon-Young
    • Journal of the Korean Geotechnical Society
    • /
    • v.36 no.10
    • /
    • pp.33-39
    • /
    • 2020
  • A geological repository has been considered as an option for the disposal of high-level radioactive waste (HLW). The HLW is disposed in a host rock at a depth of 500~1,000 meters below the ground surface based on the concept of engineered barrier system (EBS). The EBS is composed of a disposal canister, buffer material, backfill material, and gap-filling material. The compacted bentonite buffer is very important since it can restrain the release of radionuclide and protect the canister from the inflow of ground water. The saturation of the buffer decreases because high temperature in a disposal canister is released into the surrounding buffer material, but saturation of the buffer increases because of the inflow of ground water. The unsaturated properties of the buffer are critical input parameters for the entire safety assessment of the engineered barrier system. In Korea, Gyeongju bentonite can be considered as a candidate buffer material, but there are few test results of the unsaturated properties considering temperature variation. Therefore, this paper conducted experiment of soil-water characteristic curve for the Gyeongju compacted bentonite considering temperature variation under a constant water content condition. The relative error showed approximately 2% between test results and modified van-Genuchten model values.

Dental Hygienist's Harmful Factor Exposure and Recognition of Material Safety Data Sheets of Workplace Type (치과위생사의 근무기관 유형별 유해인자 노출과 물질안전보건자료 인식 연구)

  • Kim, Hae-Kyeong;Kim, Ji-Young;Oh, Na-Rae
    • The Journal of the Korea Contents Association
    • /
    • v.18 no.11
    • /
    • pp.540-549
    • /
    • 2018
  • This study was conducted on 238 dental hygienists working in Daegu and Gyeongbuk area. In order to understand the status of harmful transmission of dental materials by type of work, we compared the differences in exposure time and work environment characteristics of hospital types and investigated the difference in the degree of recognition of material safety data. The results of the study were as follows: In case of hospitals, the exposure time of dust generated from chemicals was the longest. Resin filling, contact with disinfectant. 37 workers (29.4%) and 14 workers (12.5%) answered that they perceive the question about whether they are aware of the material safety data sheet (MSDS) for dental materials. There were 18 hospital workers and 6 clinic workers who had experience reading MSDS before using dental materials. The respondents who answered that they provided the material safety data of the dental materials used had a 2.39 times MSDS in hospital workers. Therefore, by recognizing the health hazards of chemical substances in accordance with the characteristics of each type of hospital and continuing to conduct health and safety education, the work environment should be improved by establishing proper recognition of MSDS information. It suggests the necessity of a system that can strengthen the management of chemical information provision and guarantee the strategic approach and workers' right to know.

Characterization of SEI layer for Surface Modified Cathode of Lithium Secondary Battery Depending on Electrolyte Additives (전해질 첨가제에 따른 graphite 음극의 SEI분석 및 전기 화학적 특성 고찰)

  • Lee, Sung Jin;Cha, Eun Hee;Lim, Soo A
    • Journal of the Korean Electrochemical Society
    • /
    • v.19 no.3
    • /
    • pp.69-79
    • /
    • 2016
  • Lithium ion battery with high energy density is expanding its application area to electric automobile and electricity storage field beyond existing portable electric devices. Such expansion of an application field is demanding higher characteristic and stable long life characteristic of an anode material, the natural graphite that became commercialized in lithium ion battery. This thesis produced cathode by using natural graphite anode material, analyzed creation of the cathode SEI film created due to initial reaction by using electrolyte additives, VC (vinylene carbonate), VEC (vinyl ethylene carbonate), and FEC (fluoroethylene carbonate), and considered correlation with the accompanying electrochemical transformation. This study compared and analyzed the SEI film variation of natural graphite cathode according to the electrolyte additive with SEI that is formed at the time of initial filling and cathode of $60^{\circ}C$ life characteristic. At the time of initial filling, the profile showed changes due to the SEI formation, and SEI was formed in No-Additive in approximately 0.9 V through EVS, but for VC, VEC, and FEC, the formation reaction was created above 1 V. In $60^{\circ}C$ lifespan characteristic evaluation, the initial efficiency was highest in No-Additive and showed high contents percentage, but when cycle was progressed, the capacity maintenance rate decreased more than VC and FEC as the capacity and efficiency at the time of filling decreased, and VEC showed lowest performance in efficiency and capacity maintenance rate. Changes of SEI could not be verified through SEM, but it was identified that as the cycle of SEI ingredients was progressed through FT-IR, ingredients of Alkyl carbonate ($RCO_2Li$) affiliation of the $2850-2900cm^{-1}$ was maintained more solidly and the resistance increased as cycle was progressed through EIS, and specially, it was identified that the resistance due to No-Additive and SEI of VEC became very significant. Continuous loss of additives was verified through GC-MS, and the loss of additives from partial decomposition and remodeling of SEI formed the non-uniform surface of SEI and is judged to be the increase of resistance.

The Study on Application of Aerated Concrete as a Filling Material for Special Use (특수용도 충전재로서 기포콘크리트의 활용성에 관한 연구)

  • 허재원;이종필;김효열;임남기
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2004.05a
    • /
    • pp.45-50
    • /
    • 2004
  • In this study, we processed two procedures of application test of filler for special-purpose utility that are new application methods of aerated concrete and properties test of aerated concrete according to mixing ratio because we investigated the better use of aerated concrete as filler for fireproof safety and we proposed basic data about standardization of mixing of aerated concrete. We measured flow and volume change of aerated concrete. And if its volume doesn't change, we added measuring unit weight and compressive strength. To test application of aerated concrete as filler for fireproof safety, we filled up aerated concrete to fireproof safety according to suitable mixing ratio. Then we measured maximum temperature of inner part of fireproof safety in accordance with the standard test of fireproof. According to the results, aerated concrete as filler for fireproof safety could be possibly used. So when we make aerated concrete, we should consider using an adding agent as well as a foaming agent.

  • PDF

A Experiment Study of Torch Distance on Automated Tandem GMA Welding System (탄뎀 가스메탈아크 용접의 토치 극간거리에 관한 실험적 연구)

  • Lee, Ji-Hye;Kim, Ill-Soo;Jung, Seong-Myeong;Lee, Jong-Pyo;Kim, Young-Su;Park, Min-Ho
    • Journal of Welding and Joining
    • /
    • v.30 no.6
    • /
    • pp.49-55
    • /
    • 2012
  • The tandem welding process is one of the most efficient welding processes widely used in material joining technique such as manufacturing of strong and durable structures. It facilitates high rate of joint filling with little increase in the overall rate of heat input due to the simultaneous deposition from two electrode wires. The two electrodes in tandem welding process helps in high-efficiency and high productive of welding process. In this study a automated tandem welding system is developed to determine the correlation between cathode and anode and compared with current ratio of the two electrode torch. Three different inter-electrode distances were chosen, 25mm, 35mm and 45mm to perform the experiment with three different current ratio. From the experiment results, the current ratio between two torch has a large impact on width, height and depth of penetration. In addition, a stable bead geometry is obtained when inter-electrode distance is 35mm.

A study on CIM construction for the plastic fan design manufacturing (플라스택 팬 설계, 제조의 CIM 구축을 위한 연구)

  • Choi, Yang-Ho;Lee, Yong-Sung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.21 no.9
    • /
    • pp.1470-1479
    • /
    • 1997
  • In this study, the plastic fan with high efficiency and low noise was designed and the capacity of the wind and the wind pressure were analysed and verified by CAE. After designing the metallic mold using the metallic mold design data, and the the metallic mold design was reformed by analysing the process of the material stream and injection filling by CAE. Also the metallic mold cutting data were formed using the metallic mold design data. These cutting data was used to produce the fan electrode by a machining center and then this electrode were used to manufacture the metallic mold by cutting the fan cavity by an electrical spark machine. The purpose of this study is to find out the sub-optimal condition on the productivity and improvement in quality of the plastic fan by integrating a series of this process with a computer.

Analysis on Proper Cable Arrangement and Duct Distance to Maximize Ampacity of Underground Distribution Cable (지중배전케이블의 허용전류용량 증대를 위한 적정 회선배치 및 관로 이격거리 분석)

  • Jo, Ara;Moon, Won-Sik;Lee, Seung-Jae;Kim, Jae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.30 no.2
    • /
    • pp.57-64
    • /
    • 2016
  • Power demand has continuously increased with technological and economical development. The load density is also growing in the center of downtown area. In particular, underground facilities have been increased on the purpose of the prevention of urban disasters and pedestrian environment improvement. Based on this situation, the underground space in urban surroundings has gradually decreased because of the limited space. The ampacity of buried cables is affected by various factors such as cable size, soil thermal resistance, burial depth and filling material. The thermal capacity of the facilities is determined by the absorb heat surrounding the cable and the soil. The maximum operating temperature of cable is the highest temperature when the insulator of cable is not damaged in the case of high enough temperature. In this paper, the most effective cabling configuration is suggested using the duct array adjustment. It was also considered to increase the number of cable line. This underground distribution system was simulated by using ETAP(Electrical Transient Analysis Program).

Myxoma in the Laryngeal Ventricle and the True Vocal Cord:A Case Report (후두실과 진성대에 발생한 점액종 1예)

  • Kim, Seung-Woo;Yum, Dong-Jin;Kang, Jae-Ho;Kim, Choon-Dong
    • Korean Journal of Head & Neck Oncology
    • /
    • v.23 no.1
    • /
    • pp.67-70
    • /
    • 2007
  • Myxoma is an uncertain mesenchymal cell origin, characterized by irregular round, stellate or spindle cells surrounded by the matrix containing abundant mucoid material and scant vascularity. Their occurrence in descending order of frequency is in the heart, subcutaneous tissue, bone and genitourinary tract. In the head and neck region, the most predilection sites are mandible and maxilla(more than 80%). Laryngeal myxoma is extremely rare:only 5 cases have been reported in the English literature. We report a rare case of laryngeal myxoma. A 60-year-old man with hoarseness visited the out-patient department. The mass was located between the vocal fold and the vocal ligament, filling with the left laryngeal ventricle. We planned the laryngo-microsurgery and successfully excised using $CO_2$ laser. The histopathologic finding revealed the myxoma. After 18 months of surgery, there is no evidence of recurrence and mucosal scarring in the vocal fold. This report is the first case of laryngeal myxoma involving the laryngeal ventricle and the true vocal cord together.

Design Consideration of Bulk FinFETs with Locally-Separated-Channel Structures for Sub-50 nm DRAM Cell Transistors

  • Jung, Han-A-Reum;Park, Ki-Heung;Lee, Jong-Ho
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.8 no.2
    • /
    • pp.156-163
    • /
    • 2008
  • We proposed a new $p^+/n^+$ gate locally-separated-channel (LSC) bulk FinFET which has vertically formed oxide region in the center of fin body, and device characteristics were optimized and compared with that of normal channel (NC) FinFET. Key device characteristics were investigated by changing length of $n^+$ poly-Si gate ($L_s$), the material filling the trench, and the width and length of the trench at a given gate length ($L_g$). Using 3-dimensional simulations, we confirmed that short-channel effects were properly suppressed although the fin width was the same as that of NC device. The LSC device having the trench non-overlapped with the source/drain diffusion region showed excellent $I_{off}$ suitable for sub-50 nm DRAM cell transistors. Design of the LSC devices were performed to get reasonable $L_s/L_g$ and channel fin width ($W_{cfin}$) at given $L_gs$ of 30 nm, 40 nm, and 50 nm.