• Title/Summary/Keyword: Filled Water

Search Result 882, Processing Time 0.037 seconds

Estimate and Environmental Assessment of Greenhouse Gas(GHG) Emissions and Sludge Emissions in Wastewater Treatment Processes for Climate Change (기후변화를 고려한 하수처리공법별 온실가스 및 슬러지 배출량 산정 및 환경성 평가)

  • Oh, Tae-Seok;Kim, Min-Jeong;Lim, Jung-Jin;Kim, Yong-Su;Yoo, Chang-Kyoo
    • Korean Chemical Engineering Research
    • /
    • v.49 no.2
    • /
    • pp.187-194
    • /
    • 2011
  • In compliance with an international law about the ocean dumping of the sludge, the proper sewage treatment process which occurs from the wastewater treatment process has been becoming problem. Generally the sewage and the sludge are controlled from anaerobic condition when the sewage is treated and land filled, where the methane$(CH_{4})$ and the nitrous oxide $(N_{2}O)$ from this process are discharged. Because these gases have been known as one of the responsible gases for global warming, the wastewater treatment process is become known as emission sources of green house gases(GHG). This study is to suggest a new approach of estimate and environmental assessment of greenhouse gas emissions and sludge emissions from wastewater treatment processes. It was carried out by calculating the total amounts of GHG emitted from biological wastewater treatment process and the amount of the sludgegenerated from the processes. Four major biological wastewater treatment processes which are Anaerobic/Anoxic/Oxidation$(A_{2}O)$, Bardenpho, Virginia Initiative Plant(VIP), University of Cape Town(UCT)are used and GPS-X software is used to model four processes. Based on the modeling result of four processes, the amounts of GHG emissions and the sludge produced from each process are calculated by Intergovernmental Panel on Climate Change(IPCC) 2006 guideline report. GHG emissions for water as well as sludge treatment processes are calculated for environmental assessment has been done on the scenario of various sludge treatments, such as composting, incineration and reclamation and each scenario is compared by using a unified index of the economic and environmental assessment. It was found that Bardenpho process among these processes shows a best process that can emit minimum amount of GHG with lowest impact on environment and composting emits the minimum amount of GHG for sludge treatment.

Effect of Seed Priming and Pellet Coating Materials on Seedling Emergence of Aster koraiensis (프라이밍과 펠렛코팅 소재가 벌개미취 종자의 유묘 출현율에 미치는 영향)

  • Kang, Won Sik;Kim, Min Geun;Kim, Soo Young;Han, Sim Hee;Kim, Du Hyun
    • Journal of Korean Society of Forest Science
    • /
    • v.109 no.1
    • /
    • pp.41-49
    • /
    • 2020
  • In this study, the effect of seed pre-treatments and pellet coating materials to enhance the efficiency of large-scale propagation of Aster koraiensis seeds were investigated. Seeds were immersed in water for one day, and only those that sank were used for pre-treatment to use filled seeds. Pre-treatments were divided into hormone treatments, with gibberellic acid (GA3; 200 and 500 ppm) and 24-epibrassinolide (10-6, 10-7, and 10-8M), and priming with potassium nitrate (100 mM of KNO3). To produce pellet-coated seeds, pellet materials (DTCS or DTK) were applied to control (unprimed) and primed seeds with binders (PVA or CMC). The maximum germination percent (GP) of seeds before pellet coating was 65% (with the priming treatment), and there was no difference in the GP of seeds among hormone treatments. For seeds sown in a growth chamber on filter paper, GP was 41% for control (unprimed/uncoated) seeds, 65% for uncoated primed seeds, 71% for DTCS/PVA-pellet-coated seeds, and 42% for DTK/CMC-pellet-coated seeds. Seeds that were primed first and then pellet-coated showed greatly improved GP, mean germination time (MGT), and germination rate than seeds that were only pellet-coated. For seeds sown in commercial soil in a greenhouse, control seeds had a GP of 27%, whereas primed seeds had the highest GP (58%), and their MGT and GT were 9.4 days and 7.0%·day, respectively. In addition, DTK/PVA-pellet-coated seeds (40%) also had a GP higher than the control (27%), and their MGT was 15-27 days. For seeds sown in sandy-loam soil in a greenhouse, unprimed-pellet-coated seeds and primed-pellet-coated seeds both had GPs ranged of 39%, which were lower than that of control seeds. In general, the seeds that were pellet-coated with DTK had a higher GP than those pellet-coated with DTCS. Furthermore, the MGT of unprimed-pellet-coated seeds was 15.0-19.8 days, which was longer than the MGT of primed-pellet-coated seeds. These results suggest that priming enhances seedling emergence of Aster koraiensis seeds. Moreover, when priming is combined with pellet coating, DTK is a more suitable pellet material than DTCS, and PVA and CMC are equally suitable adhesives.

Effects of β-glucan and Xanthan gum-based Biopolymers on Plant Growth and Competition in the Riverbank (제방 환경 조건에서 베타글루칸-잔탄검 계열 바이오폴리머가 식물 생장 및 경쟁에 미치는 영향)

  • Jeong, Hyungsoon;Shin, Haeji;Jang, Ha-young;Kim, Eunsuk
    • Ecology and Resilient Infrastructure
    • /
    • v.7 no.3
    • /
    • pp.208-217
    • /
    • 2020
  • A biopolymer based on microorganism-derived β-glucan and xanthan gum is being studied as a new eco-friendly material that stabilizes the riverbank slope, and also promotes vegetation growth. However, it is still inconclusive whether biopolymers have a positive effect on plant performance in the riverbanks which are subjected to various climatic factors and plant competitions. For a practical ecological evaluation of the biopolymers, their effect on plant growth promotion was studied in a natural environment. Considering the relationship between competition and plant community formation, the effects of biopolymers on competition were also investigated. For four plant species (Echinochloa crus-galli, Pennisetum alopecuroides, Leonurus japonicus, and Coreopsis lanceolata), the biopolymer effects under intra/interspecific competition were tested at the riverbank (20 m × 10 m) near Samjigyo Bridge in Damyang-gun, Jeollanam-do. A biopolymer powder was mixed with water and commercial soil following the manufacturer's recommendations. The soil mixed with the biopolymer was filled in a pot or applied to the surface of the commercial soil with a thickness of 3 cm. Across the competition treatments, the biopolymer treatment promoted root growth of the target plant species and decreased the specific leaf area. The total biomass and shoot dry weight of P. alopecuroides increased in response to the biopolymer treatment. The competition treatment decreased the total biomass and shoot dry weight compared to the case without competition. Notably, such a competitive effect was similar in all the biopolymer treatments. Thus, biopolymers, when mixed with soil, promote the growth of some plant species, but do not appear to affect the competitive ability of plants.

Dose Distribution and Image Quality in the Gantry Aperture for CT Examinations (전산화단층촬영 검사 시 Gantry Aperture 내의 선량분포와 영상의 질)

  • Cho, Pyong-Kon;Kim, You-Hyun;Choi, Jong-Hak;Lee, Ki-Yeol;Kim, Hyung-Cheol;Kim, Jang-Seob;Shin, Dong-Chul;Lee, Sung-Hyun;Lee, Jun-Hyub;Shin, Gwi-Soon
    • Journal of radiological science and technology
    • /
    • v.32 no.4
    • /
    • pp.453-460
    • /
    • 2009
  • The purpose of this study was to determine the dose distribution and image quality according to slice thickness and BC(beam collimation) in the gantry aperture. CT scans were performed with a 64-slice MDCT(Brilliance 64, Philips, Cleveland, USA) scanner. To determine the dose distribution according to BC, a ionization chamber was placed at isocenter and 5, 10, 15, 20, 25 and 30 cm positions from the isocenter in the 12, 3, 6 and 9 o'clock directions. The dose distribution for phantom scan was also measured using CT head and body dose phantom with five holes at the center of the phantom and the positions of the 12, 3, 6 and 9 o'clock directions. The image noise measurement for different BCs was performed using an AAPM CT phantom. Water-filled block of the phantom was moved by 5 cm or 10 cm to the 12 o'clock direction, and the image noise was measured at the center of the phantom, and the points of 12, 3, 6 and 9 o'clock direction respectively. Some points were placed beyond the scan field of view (SFOV), so that measurement was not possible at that points. The results are as follows: The CTDIw showed a larger decrease as the source goes farther from the iso-center or the BC became wider. The CTDIw depends on the BC width more than the number of the channel of a detector array. The value of CTDIW decreased with increasing BC, but the value decreased 16.6~31.9% in the head phantom scan in air scan and 51.0~64.5% in the body phantom scan. The value of the noise was 3.9~5.9 in the head and 5.3~7.4 in the body except for BC of $2{\times}0.5\;mm$, regardless of the degree of deviation from the iso-center. When a subject was located within the SFOV, the position did not significantly affect image quality even if the subject was out of the center.

  • PDF

Comparison of Attenuation Correction Methods for Brain SPECT Ima (Brain SPECT 영상의 Attenuation Correction 방법들에 대한 비교)

  • Jo, Jin U;Kim, Chang Ho;Na, Soo Kyung;Lee, Gui Won
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.120-125
    • /
    • 2012
  • Purpose : The purpose of this study was to compare count between Chang's method and CT-based attenuation correction (AC-CT) among the attenuation correction (AC) methods for non-attenuation correction (AC-non) images of Brain SPECT (Single Photon Emission Computed Tomography). Materials and Methods : We injected $^{99m}Tc$ 37Mbq in a Hoffman 3D phantom filled with distilled water in the phantom study, and injected intravenously $^{99m}Tc$-HMPAO 740Mbq in a normal volunteer in the patient study, and then obtained Brain SPECT images with Symbia T6 of Siemens and conducted quantitative brain analysis. Transverse images to which each method was applied were rebuilt at the same position, and 6 regions of interest (ROI) were drawn on each of Slice No. 10, 20 and 30 and then the counts of AC-non, AC-CT and Chang's method were compared. Results : The mean counts of AC-non, AC-CT and Chang's method were $4606.8{\pm}511.3$, $16794.6{\pm}2429.4$, and $8752.6{\pm}896.5$, respectively, in the phantom study and $5460.8{\pm}519.6$, $15320{\pm}1171.6$ and $12795{\pm}1422.1$, respectively, in the patient study. In the phantom study, the ratio of AC-CT to AC-non was 3.70 and the ratio of Chang's method to AC-non was 1.92, and in the patient study, they were 2.85 and 2.38, respectively. Conclusion : From this study, we found that AC-CT makes higher AC than Chang's method. In addition, when Chang's method was used, AC in the patient study was higher than that in the phantom study. These results need to be considered also in other examinations.

  • PDF

The Effect of PET Scan Time on the Off-Line PET Image Quality in Proton Therapy (양성자 치료에서 영상 획득 시간에 따른 Off Line PET의 효율성 검증)

  • Hong, Gun-Chul;Jang, Joon-Yung;Park, Se-Joon;Cha, Eun-Sun;Lee, Hyuk
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.2
    • /
    • pp.74-79
    • /
    • 2017
  • Purpose Proton therapy can deliver an optimal dose to tumor while reducing unnecessary dose to normal tissue as compared the conventional photon therapy. As proton beams are irradiated into tissue, various positron emitters are produced via nuclear fragmentation reactions. These positron emitters could be used for the dose verification by using PET. However, the short half-life of the radioisotopes makes it hard to obtain the enough amounts of events. The aim of this study is to investigate the effect of off-line PET imaging scan time on the PET image quality. Materials and Methods The various diameters of spheres (D=37, 28, 22 mm) filled with distilled water were inserted in a 2001 IEC body phantom. Then proton beams (100 MU) were irradiated into the center of the each sphere using the wobbling technique with the gantry angle of $0^{\circ}$. The modulation widths of the spread out bragg peak were 16.4, 14.7 and 9.3 cm for the spheres of 37, 28 and 22 mm in diameters respectively. After 5 min of the proton irradiation, the PET images of the IEC body phantom were obtained for 50 min. The PET images with different time courses (0-10 min, 11-20 min, 21-30 min, 31-40 min and 41-50 min) were obtained by dividing the frame with a duration of 10 min. In order to evaluate the off-line PET image quality with the different time courses, the contrast-to-noise ratio (CNR) of the PET image calculated for each sphere. Results The CNRs of the sphere (D=37 mm) were 0.43, 0.42, 0.40, 0.31 and 0.21 for the time courses of 0-10 min, 11-20 min, 21-30 min, 31-40 min and 41-50 min respectively. The CNRs of the sphere (D=28 mm) were 0.36, 0.32, 0.27, 0.19 and 0.09 for the time courses of 0-10 min, 11-20 min, 21-30 min, 31-40 min and 41-50 min respectively. The CNR of 37 mm sphere was decreased rapidly after 30 min of the proton irradiation. In case of the spheres of 28 mm and 22 mm, the CNR was decreased drastically after 20 min of the irradiation. Conclusion The off-line PET imaging time is an important factor for the monitoring of the proton therapy. In case of the lesion diameter of 22 mm, the off-line PET image should be obtained within 25 min after the proton irradiation. When it comes to small size of tumor, the long PET imaging time will be beneficial for the proton therapy treatment monitoring.

  • PDF

The study of shear bond strength of a self-adhesive resin luting cement to dentin (상아질에 대한 자가 접착 레진 시멘트의 전단결합강도에 관한 연구)

  • In, Hee-Sun;Park, Jong-Il;Choi, Jong-In;Cho, Hye-Won;Dong, Jin-Keun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.5
    • /
    • pp.535-543
    • /
    • 2008
  • Purpose: The objective of this study was to compare the bonding characteristics of a new self-adhesive resin cement to dentin, which does not require bonding and conditioning procedure of the tooth surface, and conventional resin cement. The effect of phosphoric acid etching prior to application of self-adhesive resin cement on the shear bond strength was also evaluated. Material and methods: Fortyfive non-carious human adult molars extracted within 6 months were embedded in chemically cured acrylic resin. The teeth were ground with a series of SiC-papers ending with 800 grit until the flat dentin surfaces of the teeth were exposed. The teeth were randomly divided into 3 experimental groups. In group 1, self-adhesive resin cement, RelyX Unicem (3M ESPE, Seefeld, Germany) was bonded without any conditioning of teeth. In group 2, RelyX Unicem was bonded to teeth after phosphoric acid etching. For group 3, Syntac Primer (Ivoclar Vivadent AG, Schaan, Liechtenstein) was applied to the teeth before Syntac adhesive (Ivoclar Vivadent AG, Schaan, Liechtenstein) and Helibond (Ivoclar Vivadent AG, Schaan, Liechtenstein) followed by conventional resin cement, Variolink II (Ivoclar Vivadent AG, Schaan, Liechtenstein). To make a shear bond strength test model, a plastic tuble (3 mm diameter, 3 mm height) was applied to the dentin surfaces at a right angle and filled it with respective resin cement, and light-polymerized for 40 seconds. All the specimens were stored in distilled water at $37^{\circ}C$ for 24 hours before test. Universal Testing Machine (Z020, Zwick, Ulm, Germany) at a cross head speed of 1 mm/min was used to evaluate the shear bond strength. The failure sites were inspected under a magnifier and Scanning Electron Microscope. The data was analyzed with One way ANOVA and Scheffe test at ${\alpha}$= 0.05. Results: (1) The shear bond strengths to dentin of RelyX Unicem was not significantly different from those of Variolink II/Syntac. (2) Phosphoric acid etching lowered the shear bond strength of RelyX Unicem significantly. (3) Most of RelyX Unicem and Variolink II showed mixed fractures, while all the specimens of RelyX Unicem with phosphoric acid etching demonstrated adhesive failure between dentin and resin cement. Conclusion: Shear bond strength to dentin of self-adhesive resin cement is not significantly different from conventional resin cement, and phosphoric acid etching decrease the shear bond strength to dentin of self-adhesive resin cement.

A STUDY ON MICROLEAKAGE OF PREVENTIVE RESIN RESTORATION (예방적 레진수복의 미세누출에 관한 연구)

  • Koo, Hyun-Jung;Lee, Sang-Hoon;Hahn, Se-Hyun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.3
    • /
    • pp.504-511
    • /
    • 2001
  • Preventive resin restoration, extended concept of occlusal pit and fissure sealing, is procedure composed of as follows. Cavity preparation is limited to areas of initial caries The cavity is then restored with composite resin, while other sound pits and fissures are sealed with pit and fissure sealant. If pit and assure sealant with which microrestoration is possible is used, it may be of great benefit to both patient and operator in case of difficult-to-control children s treatment. However study on preventive resin restoration using this kind of materials have been scarce. The purpose of this study was to compare the microleakage of four different modes of preventive resin restoration. Restoration using only composite resin was compared together Fifty-five bicuspids were prepared with small class I cavity preparation on the occlusal surface, divided into the following groups and restored accordingly. Group 1 : Cavity was restored with Z-100 composite resin Group 2 : Cavity was restored with Z-100 composite resin. Pits and fissures were then sealed with Teethmate F-1 Group 3 : Cavity was restored with Z-100 composite resin Pits and fissures were then sealed with Ultraseal XT-plus Group 4 : Cavity and pits and fissures were restored with Ultraseal XT-plus altogrether Group 5 : Cavity was restored with Ultraseal XT-plus. Pits and fissures were then sealed with the same material. After restoration, the samples were thermocycled 500 times between $5^{\circ}C$ and $55^{\circ}C$ with a dwell time of 30 seconds. After thermocycling, the samples were dipped into 1% methylene blue solution for 24 hours, then rinsed with tap water. The teeth were then embedded in resin and cut buccolingually along the tooth axis and observed with a stereomicroscope to determine the degree of microleakage. The results were as follows : 1. Group 4 showed the greatest microleakage, while group 3, showed the least. The mean microleakage decreased in the following order:4>1>5>2>3. 2. There was no stastically significant difference between group 1 and group 5(p>0.05). However, group 1 showed significantly greater microleakage compared to group 2 and 3(p<0.05) Group 1 showed significantly less microleakage compared to group 4(p<0.05). 3. Group 2 showed no statistically significant difference compared to group 3(p>0.05). However group 2 showed significantly less microleakage compared to group 4 and 5(p<0.05) 4. Group 3 showed significantly less microleakage compared to group 4 and 5(p<0.05). 5. Group 5 showed significantly less microleakage than group 4(p<0.05).

  • PDF

Root Uptake of $^{54}Mn,\;^{60}Co,\;^{85}Sr\;and\;^{137}Cs$ Deposited at Different Times during the Growing Season of Rice (벼 재배 기간중 침적시기에 따른 Root Uptake of $^{54}Mn,\;^{60}Co,\;^{85}Sr,\;^{137}Cs$의 뿌리흡수)

  • Choi, Yong-Ho;Jo, Jae-Seong;Lee, Chang-Woo;Hong, Kwang-Hee;Lee, Jeong-Ho
    • Journal of Radiation Protection and Research
    • /
    • v.20 no.4
    • /
    • pp.255-263
    • /
    • 1995
  • Root uptakes of $^{54}Mn,\;^{60}Co,\;^{85}Sr\;and\;^{137}Cs$ by rice were studied through a greenhouse experiment in which the upper 20 cm of the culture box was filled with an acidic loamy-sandy soil and a mixed solution of the radionuclides was applied to the surface water on the soil 2 days before, and 5 different times after, transplanting. Percent uptakes of the radionuclides to rice tops varied $3.4{\sim}13.7%,\;0.03{\sim}0.1%,\;0.6{\sim}1.5%,\;0.02{\sim}0.15%$, respectively, with application time. Among radionuclides, soil-to-plant transfer factors decreased, on the whole, in the order of $^{54}Mn>^{85}Sr>^{60}Co{\geq}^{137}Cs$, and among plant parts, in the order of straw > chaff > hulled seed. Transfer factors $(m^2/kg-dry)$ in hulled seed were, depending on application time, $1.2{\times}10^3{\sim}5.0{{\times}10^3\;for\;^{54}Mn,\;1.6{\times}10^5{\sim}2.6{\times}10^4\;for\;^{60}Co,\;1.1{\times}10^4{\sim}7.6{\times}10^4\;for\;^{85}Sr\;and\;5.2{\times}10^5{\sim}7.0{\times}10^4\;for\;^{137}Cs$. The highest factors of all the radionuclides in straw came from the application at 67 days after transplanting while those of $^{54}Mn,\;^{60}Co\;and\;^{85}Sr$ in hulled seed appeared at later applications. The data from this studv can be referred to in assessing the radiological impact of an accidental contamination during the rice growth.

  • PDF

INFLUENCE OF REBONDING PROCEDURES ON MICROLEAKAGE OF COMPOSITE RESIN RESTORATIONS (복합레진 수복 시 재접착 술식이 미세누출에 미치는 영향)

  • Lee, Mi-Ae;Seo, Duck-Kyu;Son, Ho-Hyun;Cho, Byeong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.3
    • /
    • pp.164-172
    • /
    • 2010
  • During a composite resin restoration, an anticipating contraction gap is usually tried to seal with low-viscosity resin after successive polishing, etching, rinsing and drying steps, which as a whole is called rebonding procedure. However, the gap might already have been filled with water or debris before applying the sealing resin. We hypothesized that microleakage would decrease if the rebonding agent was applied before the polishing step, i.e., immediately after curing composite resin. On the buccal and lingual surfaces of 35 extracted human molar teeth, class V cavities were prepared with the occlusal margin in enamel and the gingival margin in dentin. They were restored with a hybrid composite resin Z250 (3M ESPE, USA) using an adhesive AdperTM Single Bond 2 (3M ESPE). As rebonding agents, BisCover LV (Bisco, USA), ScotchBond Multi-Purpose adhesive (3M ESPE) and an experimental adhesive were applied on the restoration margins before polishing step or after successive polishing and etching steps. The infiltration depth of 2% methylene blue into the margin was measured using an optical stereomicroscope. The correlation between viscosity of rebonding agents and mciroleakage was also evaluated. There were no statistically significant differences in the microleakage within the rebonding procedures, within the rebonding agents, and within the margins. However, when the restorations were not rebonded, the microleakage at gingival margin was significantly higher than those groups rebonded with 3 agents (p < 0.05). The difference was not observed at the occlusal margin. No significant correlation was found between viscosity of rebonding agents and microleakage, except very weak correlation in case of rebonding after polishing and etching at gingival margin.