• 제목/요약/키워드: Filled Water

검색결과 882건 처리시간 0.033초

퇴적암의 층리면을 따라 형성된 충전물에 의한 암반사면 붕괴사례 (Case Study on Failure of Rock Slope Caused by Filling Material Formed along the Bedding Plane of Sedimentary Rock)

  • 김용준;이영휘;이종성;김우준
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2006년도 추계 학술발표회
    • /
    • pp.256-267
    • /
    • 2006
  • After heavy rainfall, It was occurred massive plane failure along bedding plane of shale in the center of rock slope. It was observed filling material and trace of underground water leakage around of the slope. We tried to find the cause for slope failure, and the result of examination showed that primary factors of the failure were low shear strength of clay filling material and water pressure farmed within tension crack existed in the top of the slope. In this research, in order to examine the features of shear strength of filled rock joint, shear test of filled rock joint was conducted using of artificial filling material such as sand and clay. Also we made an investigation into the characteristics of shear strength with different thickness of filling materials.

  • PDF

수막재배 단동비닐하우스의 태양열 축열이용 효과분석 (Analysis of Solar Energy Storage Using Effectiveness on Single Span Plastic Greenhouse with Water Curtain System)

  • 이성현;유영선;문종필;윤남규;이수장;김경원
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 춘계학술대회 초록집
    • /
    • pp.200.2-200.2
    • /
    • 2010
  • This study was carried out in order to reduce the amount of underground water which is used in the water curtain system for retaining heat. To proceed to the research, two plastic green houses of water curtain system were installed. One was equipped of internal small tunnel for keeping warm air in the interior of the house. Then the internal small tunnel for keeping warm air was fitted with PVC duct of 50cm in diameter filled with subsurface water. Storing surplus solar energy in the water filled in PVC duct was the method used to this house. Another was installed with FCU in the middle of the house, and was fitted a circulation motor in water tank for heat storage which was operated from 10 a.m. to 4 p.m. in order to interchange heat with FCU. The latter was installed with four FCUs which has a capacity of 8000kcal per hour. Consequently about 5 degrees celsius could be maintained in the interior of the internal small tunnel for keeping warm air with the external temperature of more than minus 5 degrees celsius. It appeared that the alteration of an internal temperature of the house was flexible depending on the sunlight during daytime. It happened that to prevent the water from freezing, mixing antifreezing liquid in the flowing water of FCU or changing the operating method of FCU was a suitable measure. Also, in order to use the surplus solar thermal energy on plastic green house of water curtain system efficiently, storing the surplus heat during daytime simultaneously finding a method of using water curtain systematic underground water happened to be important. As a result of this research, when the house's interior temperature is below zero the operation of FCU appeared to be impossible. Therefore when supposed that the amount of water used in the house is 150~200ton for stable operation of FCU, using the system mentioned in the above research happened to be appropriate of reducing the amount of subsurface water from 80% to 100% when maintaining the interior of internal small tunnel's temperature for keeping warm air of 5 degrees celsius at the extreme temperature of minus 5 degrees celsius.

  • PDF

비소와 철 동시제거를 위한 Fe-GAC와 GAC로 충진된 컬럼 (Column filled with Fe-GAC and GAC to remove both As(V) and Fe(III))

  • 이용수;도시현;홍성호
    • 상하수도학회지
    • /
    • 제30권1호
    • /
    • pp.87-97
    • /
    • 2016
  • First of all, Fe or/and Mn immobilized granular activated carbons (Fe-GAC, Mn-GAC, (Fe, Mn)-GAC) were synthesized and tested to remove arsenate (As(V)). The results in batch test indicated that Fe-GAC removed As(V) effectively, even though the surface area of Fe-GAC was reduced largely. Moreover, adsorption isotherm test indicated that the experimental data fit well with Langmuir model and the maximum adsorption capacity ($q_{max}$) of Fe-GAC for As(V) was $3.49mg\;g^{-1}$, which was higher than GAC ($2.24mg\;g^{-1}$). In column test, the simulated water, which consisted of As(V), Fe(III), Mn(II) and Ca(II) in tap water, was used. Fe-GAC column with 1 hr of pre-washing time treated As(V) effectively while GAC column removed Fe(III) better than Fe-GAC column. Moreover, the increasing pre-washing time from 1 to 9 hour in Fe-GAC column enhanced Fe(III) removal with little negative impact of As(V) removal. Mostly, the column filled with Fe-GAC and GAC (i.e. the mass ratio of Fe-GAC:GAC = 2:8) showed the higher treatability of both As(V) and Fe(III), even it operated with 1 hr pre-washing time.

퇴비단 여과재 구성에 따른 혐기소화액 여과 효과 (A Study on Filtration Effect of Anaerobic Digestion Wastewater by Composition of Filtration Layer Materials)

  • 이동현;정광화;;김중곤;곽정훈;안희권;김은종
    • 한국축산시설환경학회지
    • /
    • 제19권1호
    • /
    • pp.39-46
    • /
    • 2013
  • This study was carried out to compare the filtration effect of anaerobic digestion waste water by compost filtration bed. Three types of filtration systems were set for filtration test following to composition of bedding materials. Two filtration systems were filled with sawdust, rice-hull and wood-chip. And the other was filled with sawdust and rice-hull. Anaerobic digestion waste water was applied evenly on the surface of the filtration bed with spraying nozzle. The concentration of nitrogen, biochemical oxygen demand (BOD), suspended solids (SS) of anaerobic digestion waste water was decreased by filtration treatment. The total nitrogen content was decreased from 1,313 mg/L to 1,090~1,293 mg/L and BOD concentration was decreased from 529.7 mg/L to 125~162.3 mg/L, respectively. The SS content was decreased from 69~79% by filtration process. In addition, the electrical conductivity (EC) was decreased from 10.22 ds/m to 7.91~8.31 ds/m.

두상관수장치의 부채꼴분사노즐 설치위치가 살수균일성에 미치는 영향 (Effect of a Suspended Overhead Sprayer with Sector Formed Injection Nozzles on Spraying Uniformity)

  • 김명규;정태상;민영봉
    • 생물환경조절학회지
    • /
    • 제8권4호
    • /
    • pp.223-231
    • /
    • 1999
  • 육묘장의 두상관수장치는 균일하게 관수되어야 모종도 균일하게 성장한다. 본 연구에서는 부채꼴 분사노즐을 이용한 두상관수장치의 노즐 설치위치에 따른 관수상태를 조사하여 균일관수방법을 구명하였다. 살수량은 주행속도에 반비례하였고, 관수균일도는 노즐과 관수면과의 거리에 큰 영향을 받으며 주행속도의 영향은 없었다. 단일노즐에 의한 두상관수인 경우 노즐 끝에서 관수면이 60cm 이상 멀어질수록 관수균일도가 향상되며, 연속노즐에 의한 두상관수인 경우 관수면이 노즐분사 각도의 2차 교차점에 위치할 때 관수균일도가 가장 좋은 것으로 나타났다. 두상관수장치의 균일관수를 위해서는 작물의 머리높이가 분사노즐의 2차교차점에 일치하도록 노즐의 위치를 정해야 하며 작물의 자람에 따른 노즐대 놀이를 조절해 주는 것이 바람직한 것으로 판단된다.

  • PDF

The Flow Analysis of Virtual Channel depending upon the change of two ingates

  • Kim, Nam-Hyeong;Kim, Gyeong-Bo
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2006년도 학술발표회 논문집
    • /
    • pp.1636-1640
    • /
    • 2006
  • SMAC method, one of the computational fluid dynamics techniques, is modified from the original MAC method for the time-dependent variation of flow analysis. The Navier-Stokes equations for incompressible time-dependent viscous flow are applied, and also marker particles that present the visualization of flow analysis are used. In this study SMAC technique is used to analyze the flow behavior in the water-filling of virtual channel. Then by changes of diameter of two ingates, the change of velocity and discharge when two ingates are filled the water to virtual channel are simulated. As a result, water-filling flow pattern in the virtual channel is simulated very well. Therefore, this numerical simulation will also be applied for the design of structures as open flume and porous breakwater.

  • PDF

전천후농업용수원 개발을 위한 중요하천 수계별 기본조사의 실시 (Basic Investigation on the Water Resource Development of the Principal Riever Basins for All Weather Farming)

  • 임은진
    • 한국농공학회지
    • /
    • 제9권2호
    • /
    • pp.1291-1295
    • /
    • 1967
  • This paper is a brief description on the task of the basic investigation of the water resource development of the principal river basins in this country for all- weather farming. In order to show how the people in the nation can best be benefited by further development of the water resources of the basins, this paper includes a description of the in individual basin's resource, its needs and problems, and its present and future development of the water resources within the natural drainage basin of the rivers are listed and their over-all results are summarised in the investigation report and separately filled. It is hoped that the government should continue and expand its detailed investigations of potential projects within the each principal river basin to obtain adequate information by which the Union of Land improvement Association can formulate a comprehensive plan for use of all the water resources of the basin's and select and recommend projects for successive stages of development.

  • PDF

경량기포혼합 준설토의 강도특성 (Strength Characteristics of Light-Weight Cement mind Marine Clay with Foam)

  • 박건태;김주철;윤길림;이종규
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.483-490
    • /
    • 2002
  • A massive amount of marine clay produced as dredging of coast and sea bed is often dumped in open sea and filled in pond. The treatment of marine clay demand a large area and make fatal environmental problems for echo system. This research work intend to manufacture a light-weight landfill materials which are produced by mixing the dredged marine clay with various amount cement and foam. An extensive Uniaxial and Triaxial compression test are carried out to investigate the strength characteristics of the light-weight cement mixed marine clay with foam under various test conditions. The results indicated that the required unit weight has been achieved with negligible change after 28days curing time in water. It is also recognized that the compressive strength of light-weight landfill materials linearly decrease with increasing initial water content, and the rate of strength decrease with increasing initial water content in water curing was smaller than that of air curing Futhermore, the rate of strength decreased with increasing initial water content, however, the rate become smaller as cement content increased.

  • PDF

바이오스톤 볼 수처리 시스템에 의한 오염물질 저감 및 저수지의 수질개선효과 산정 (Estimation of Water Quality Improvement and Reduction of Influent Pollution by Installation of Water Treatment System Filled with Bio-stone Ball)

  • 최선화;김흥섭;정세웅
    • 환경영향평가
    • /
    • 제28권5호
    • /
    • pp.471-482
    • /
    • 2019
  • 본 연구에서는 유기성 오염도가 높은 국내 하천 및 호소의 수질정화를 위해 바이오스톤 볼 담체를 이용한 수처리 기술을 개발하였다. 바이오스톤 볼 수처리기술의 오염물질 제거효율 및 저수지 수질개선효과 등을 평가하기 위하여 경기도 시흥시에 위치한 매화저수지에 실증플랜트를 설치하였다. 바이오스톤 볼 수처리시스템의 오염물질 제거효율은 BOD 70.3%(47.2~97.4%), COD 45.3%(26.1~64.7%), TOC 19.2%(8.5~50.0%), SS 82.8%(73.1~92.7%), Chl-a 80.4%(57.2~91.8%), TN 23.2%(6.4~39.5%), TP 51.8%(-1.1~80.1%)로 나타나 BOD, SS, Chl-a에서 평균 70~80% 이상의 매우 높은 정화효율을 나타내었다. 바이오스톤 볼 수처리시스템을 저수지 평시 유입량 설계기준으로 설치하였을 경우의 유입 오염물질 저감량 및 저수지 수질개선효과를 산정하였다. 저감되는 COD 부하량은 13,658 kg으로 연간 39.2%가 저감되고, TP 부하량은 297 kg으로 연간 16.8%가 저감되는 것으로 나타났다. 저수지의 연간 수질개선효과는 TOC $5.3{\rightarrow}4.5mg/L$(14.5%), COD $7.9{\rightarrow}6.8mg/L$(14.5%), Chl-a $42.3{\rightarrow}37.0mg/m^3$(12.5%), T-P $0.201{\rightarrow}0.150mg/L$(25.1%)가 평균적으로 개선되는 것으로 나타났다. 바이오스톤 볼 수처리시스템은 유기성 오염도가 높은 국내 하천 및 호소의 유입수 오염물질 제거 및 수질정화를 위한 수처리 시설로서 현장적용성이 높을 것으로 판단된다.

가변전열 히이트 파이프의 특성에 관한 연구 (An experimental study on heat transfer characteristics of variable conductance heat pipe)

  • 김주년;이영호;김용모
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제8권1호
    • /
    • pp.4-16
    • /
    • 1984
  • The heat-pipe is characterised by the highly effective thermal conductance. In order to change the thermal conductance, the heat-pipe is connected to a reservior having a space which is filled with non-condensable gas. In normal operation, the vapour of working fluid will tend to pump the non- condensable gas into the reservoir and the gas-vapour interface situates at some point along the condenser section. The thermal conductance is affected by non- condensable gas. It is concluded that the suitable position of interface can be used to control the temperature of condenser section. In this experiment, the evaporating part is connected to the lowest position of heat-pipe. The copper heat-pipe which is filled with Freon-113 or distilled water as working fluid utilized. As results of experimental study, thermal conductance can be increased by the operating pressure which is infulenced by non-condensable gas. A correlative equation between the thermal conductance and the mass of non- condensable gas is also obtained.

  • PDF