• Title/Summary/Keyword: Filed test

Search Result 170, Processing Time 0.027 seconds

Display Panel for AMOLED with 64 x 64 Pixels on 2' Plastic Substrate

  • Song, Chung-Kun;Ryu, Gi-Seong;Choe, Ki-Beom
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.356-358
    • /
    • 2004
  • In this paper we fabricated and succeeded to demonstrate a test panel for AMOLED on 2" glass and PET substrate. The test panel consisted of an array of 64 x 64 pixels in which OLEDs was driven by pentacene TFT. OTFTs were made of the inverted staggered structure and employed polyvinylphenol as the gate insulator and pentacene thin film as the active layer, producing the filed effect mobility of 0.3$cm^2$/V.sec and on/off current ratio of $10^5$. OLEDs were composed of TPD for HTL and Alq3 for EML with 35nm thick each, generating green monochrome light.

  • PDF

A Study on the Development of Raingage with a Resolution of 0.1mm (측정 분해능이 0.1mm인 우량계의 개발에 관한 연구)

  • 이부용
    • Journal of Environmental Science International
    • /
    • v.8 no.4
    • /
    • pp.419-422
    • /
    • 1999
  • A new method is developed to measure rainfall with high accuracy and resolution. The principle of new method is to detect a weight change of a buoyant weight according to a change in water level of raingage measured by the use of a strain-gage load cell. Field test of the method was carried out on 30 September 1998, when there was heavy rainfall with total amount of 189.60mm. The results are as follows; 1) In spite of heavy rainfall, this new method showed the total error of only 1.5% against the total amount of 189.60mm. 2) This new mechanism accomplished high accuracy and resolution at filed test in heavy rainy day. 3) The present study provided a possibility to develop a new raingage with an 0.01mm in rainfall measurement.

  • PDF

Installation Damage Assessment of Rigid Geogrid by Field Tests (현장실험에 의한 강성 지오그리드의 내시공성 평가)

  • Cho, Sam-Deok;Oh, Se-Yong;Lee, Kwang-Wu
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2004.03b
    • /
    • pp.978-985
    • /
    • 2004
  • Geogrid may be damaged during its installation in the filed. The installation damage mainly depends on two factors, which are materials used and construction activities. Materials relate to geogrid and soils, and construction activities are mainly related to installation of geogrid and compaction of soils. This paper describes the results of a series of field tests, which were conducted to assess the installation damage of the various geogrids according to different fill materials. After field installation damage tests, the change in tensile strength of geogrids was determined from wide width tensile tests using both damaged and undamaged specimens.

  • PDF

Strengthening method against Overturn of Plain Concrete Gravity Pier for Open-Steel-Plate-Girder Railway Bridges (철도판형교 무근콘크리트 교각의 전도 보강기법)

  • Lee, Jun-S.;Choi, Eun-Soo;Rhee, In-Kuy;Lee, Joo-B.
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.1165-1173
    • /
    • 2007
  • Open-Steel-Plate-Girder railway bridges, in general, have plain concrete gravity pier without piles at foundations. Such piers are vulnerable to be overturned against braking forces and ground shakings during an earthquake. Thus, this study suggests a strengthening method using earth anchors to improve the resistance of plain concrete gravity piers to the overturn of themselves. Also, a filed test was performed for the as-built and the strengthened pier and the test results were compared to assess the strengthening effect. The earth anchors increased the ultimated capacity for the pier's overturn. Finally, a FE analysis was conducted using nonlinear elements for soil to understand the distribution of the soil stresses for the as-built and the strengthened pier.

  • PDF

The Effects of Various Cement Type and Compositions on the Material Properties of high Strength Concrete (시멘트 특성의 변화가 고강도콘크리트의 재료특성에 미치는 영향)

  • 백상현;이종열;엄태선;임채용;안광원
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.04a
    • /
    • pp.47-52
    • /
    • 2000
  • Recently, it is very necessary the development of the manufacturing techniques for high strength concrete(HSC) for the large-scale size and good quality of civil structure. But, the manufacture and quality control of HSC of which shrinkage, heat of hydration and workability at construction filed are considered, is very difficult due to its low water-cement ratio and high quantity of unit cement content. In the present study, we tried to know and assess the influences of chemical and physical properties of cement on the material properties of HSC. We analyzed basic properties of 4 kinds of cement whose chemical and physical properties are different each other through various tests such as chemical analysis and mortal test. Also, we performed the assessment of the material properties of HSC for each dement by the test for the conditions of same mix design and similar compressive strength. From the results in the study, the assessment of the important quality factors of cement influencing the properties of HSC may be utilized to quality control of applied cement to manufacture the HSC of high quality.

  • PDF

A Study on the Rational Shear Model by interpretation of Stuttgart Beam Shear Test (Stuttgart 콘크리트 보 전단실험의 재해석을 통한 합리적 전단모델 연구)

  • 김우;모귀석;정제평
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.05a
    • /
    • pp.884-889
    • /
    • 2003
  • Based on the reinterpretation of the well-known relationship between shear and the rate of change of bending moment in a reinforced concrete beam subject to combined shear and moment loads, the shortcomings of present truss models are discussed. The core of the theory is that a new perspective on the shear strength can be gained by viewing the internal stress filed in terms of the superposition of two base components of shear resistance; arch action and beam action. The arch action can be designed using the simple truss having curved compression chord, while the beam action between the two chords can be modeled using a parallel chord truss with MCFT or RA-STM. The compatibility of deformation associated to the two action is taken into account by employing a characteristic factor a. The new model was examined by the Stuttgart beam shear tests, and the results show that the present approach provides good estimates of stirrup contribution and concrete contributions.

  • PDF

Estimation of Inelastic Response for Building Structure by Analysis Method (해석방법에 따른 빌딩구조물의 비탄성 응답 평가)

  • Chang, Dong-Hui;Song, Jong-Keol;Chung, Yeong-Hwa
    • Journal of Industrial Technology
    • /
    • v.25 no.A
    • /
    • pp.31-38
    • /
    • 2005
  • Recent earthquakes have shown that near-field earthquakes can produce spectral demands significantly larger than those considered in current design code. International Atomic Energy Agency (IAEA) has recently initiated a coordinated research program on safety significance of near-field earthquakes. The purpose of this program is to focus on the assessment of vulnerability of nuclear facility structures by using and adapting the best available engineering practices appropriate to evaluate the effects of near-field earthquakes. The objective of this paper is to evaluate of seismic responses of a shear building test specimen subjected to near-filed earthquakes. To achieve the objective, the seismic responses of the test specimen, evaluated by the Displacement Coefficient Method (DCM) and Nonlinear Dynamic Analysis (NDA), are compared with those by the experimental tests.

  • PDF

Performance Analysis of LTE-R Radio Communication Systems in High Speed Train Environment (열차 고속 주행환경에서 LTE-R 무선통신시스템 성능 분석)

  • Kwon, You-Chul;Choi, Jun-Sung;Oh, Hyun-Seo;Kim, Seong-Cheol
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.17 no.4
    • /
    • pp.587-594
    • /
    • 2022
  • This paper analyzed radio link throughput performance by applying radio link simulation and test equipment because there is limit in train filed test in 420 km/h high speed environment. According to the radio performance analysis, the throughput performance is slightly degraded in QPSK and 16QAM modulation schemes. But throughput performance is highly degraded in 64QAM modulation scheme.

Prediction of Penetration Rate of Sheet Pile Using Modified Ramberg-Osgood Model (수정 Ramberg-Osgood 모델을 이용한 널말뚝의 관입속도 예측)

  • Lee, Seung-Hyun;Kim, Byoung-Il;Kim, Zu-Cheol;Kim, Jeong-Hwan
    • Journal of the Korean Geotechnical Society
    • /
    • v.26 no.1
    • /
    • pp.55-62
    • /
    • 2010
  • Dynamic soil resistances were simulated by modified Ramberg-Osgood model in order to predict penetration rate of sheet pile installed by vibratory pile driver. Various factors which characterize modified Ramberg-Osgood model were determined considering the shapes of dynamic soil resistance curves obtained from field test and standard penetration value (N value) was used as parameter that relates field test results to the suggested model. Penetration rates calculated by analytical model were smaller than those of field test and penetration times were vice versa. Therefore, predicted penetration rate and penetration time by analytical model are more conservative than those of filed test.

A Study on the Mechanical Properties of SM490A by FCAW Welding Attitude (SM490A의 FCAW 용접 자세별 형상에 관한 기계적 특성 연구)

  • Lim, Kwang Mook;Lee, Sung Ill
    • Journal of the Korean Society of Safety
    • /
    • v.34 no.6
    • /
    • pp.7-12
    • /
    • 2019
  • Flux Cored Arc Welding (FCAW), which has been widely used in many industries, was developed in the 1950s to supplement shortcomings of the Shielded Metal Arc Welding (SMAW). FCAW has an advantage in that it can weld regardless of postures and give good quality results in the filed with many different working conditions. In this study, SM490A (rolled steel for welding structural purpose) with different thicknesses (L:25T+R:30T) were welded using FCAW. Then the mechanical properties (tension test, bending test, hardness test, impact test and macro test) were analyzed and the following conclusions were drawn. In the tensile test, it exceeds the KS standard tensile strength range (400~510) in all welding positions, which means there is a problem in the tensile force transmission performance. In the bending test, it was found that most of the specimens did not exhibit surface rupture or other defects during bending test and they exhibit sufficient toughness even after plastic deformation. In the hardness test, all the results were lower than the standard value of 350 Hv of KS B 0893, which means they have good hardness. In the impact test, all results were larger than the KS reference value of 27J. In the macro test, they showed uniform structure state by the shape of the weld, and there was risk of lamination because no internal defects, bubbles, or impurities were found on the surface of the weld.