• 제목/요약/키워드: Field-in-Field technique (FIF)

검색결과 9건 처리시간 0.028초

A Smart Setup for Craniospinal Irradiation

  • Peterson, Jennifer L.;Vallow, Laura A.;Kim, Siyong;Casale, Henry E.;Tzou, Katherine S.
    • 한국의학물리학회지:의학물리
    • /
    • 제24권4호
    • /
    • pp.230-236
    • /
    • 2013
  • Our purpose is to present a novel technique for delivering craniospinal irradiation in the supine position using a perfect match, field-in-field (FIF) intrafractional feathering, and simple forward-optimization technique. To achieve this purpose, computed tomography simulation was performed with patients in the supine position. Half-beam, blocked, opposed, lateral, cranial fields with a collimator rotation were matched to the divergence of the superior border of an upper-spinal field. Fixed field parameters were used, and the isocenter of the upper-spinal field was placed at the same source-to-axis distance (SAD), 20 cm inferior to the cranial isocenter. For a lower-spinal field, the isocenter was placed 40 cm inferior to the cranial isocenter at a constant SAD. Both gantry and couch rotations for the lower-spinal field were used to achieve perfect divergence match with the inferior border of the upper-spinal field. A FIF technique was used to feather the craniospinal and spinal-spinal junction daily by varying the match line over 2 cm. The dose throughout the target volume was modulated using the FIF simple forward optimization technique to obtain homogenous coverage. Daily, image-guided therapy was used to assure and verify the setup. This supine-position, perfect match craniospinal irradiation technique with FIF intrafractional feathering and dose modulation provides a simple and safe way to deliver treatment while minimizing dose inhomogeneity.

유방암 방사선치료에서 Field-in-Field (FIF) 기법의 조사면 주변 선량 분석 (Evaluation of Surface Dose for Field-in-Field (FIF) Technique in Breast Radiotherapy)

  • 조일훈;김대홍
    • 한국방사선학회논문지
    • /
    • 제16권7호
    • /
    • pp.851-856
    • /
    • 2022
  • 본 연구의 목적은 종속조사면 병합 (Field-in-Field, FIF) 방식을 이용하여 유방암 방사선 치료에서 조사면 주변 표면선량 감소 효과를 확인하는 것이다. 방사선 조사를 위해 선형가속기를 사용했으며, 조사면 주변 선량은 유리 선량계로 측정하였다. SSD는 90 cm, 조사면은 10 × 10 cm2, X-선 에너지는 각각 6 MV와 10 MV를 사용했다. FIF 방식의 표면선량과 비교를 위해 금속쐐기(Physical Wedge, PW)와 동적쐐기(Dynamic Wedge, DW) 방식에서 선량을 측정하였다. PW와 DW 방식에서 각각 15°와 30°의 쐐기 각도를 사용하였다. 표면선량은 조사면 중심부에서 각각 1 cm, 3 cm, 5 cm 지점에서 측정하였다. 표면선량 분석 결과 FIF는 P W와 DW와 비교하여 치료 빔의 에너지, 쐐기 각도, 선량 측정 위치에 관계없이 모두 낮은 표면선량 값을 보였다. FIF는 유방암 치료에서 조사면 주변부 선량을 낮출 수 있으므로 표적에 균등한 선량 분포 획득뿐 만 아니라 방사선 빔에 의한 2차 장해를 감소시킬 수 있을 것으로 기대된다.

전신조사방사선치료 시 Isodose Structure를 이용한 Field-in-Field Technique의 유용성 평가 (Feasibility Study of Isodose Structure Based Field-in-Field Technique for Total Body Irradiation)

  • 이윤희;반태준;이우석;강태영;백금문
    • 대한방사선치료학회지
    • /
    • 제25권1호
    • /
    • pp.15-24
    • /
    • 2013
  • 목 적: 본원에서는 전신조사방사선치료 시 양 팔을 몸에 붙이고 누워있는 환자에게 좌우 양방향으로 방사선을 조사한다. 누운 자세는 기준점 두께에 대하여 신체 다른 부위와 두께 차이가 크기 때문에 보상체의 제작이 필요하고, 기준 깊이(Umbilicus) 처방선량에 대하여, 양팔(Arms)로 가려지지 않은 흉부와 복부 전면(Anterior)은 최대 20%까지의 선량차이가 나는 고 선량 영역이 된다. 이에 본 연구에서는 전신조사방사선치료 시 고 선량 영역과의 선량 차이를 줄일 수 있는 Isodose Structure를 이용한 Field-in-Field (FIF) Technique의 유용성을 평가 하고자 한다. 대상 및 방법: 인체모형등가팬텀(Rando Phantom, Alderson Resarch Laboratories Inc. Stamford. CT, USA, With Arm)으로 전산화단층촬영모의치료기의 영상을 획득하여 FIF와 납(Pb) 보상체를 이용한 전산화치료계획(Eclipse, version 10.0, Varian, USA)을 수립하였다. 두 치료계획의 흉부와 복부 부위의 선량분포를 비교하고, 수립된 치료계획을 이용하여 인체모형등가팬텀에 선량을 조사한 후, 열형광선량계(thermoluminescence dosimeter, TLD)와 필름(Film)을 이용하여 측정하였다. 결 과: 두 치료계획을 비교해 본 결과 기준깊이 처방선량에 대하여 팔로 가려지지 않은 흉부와 복부 전면의 선량차이는 FIF에서는 106~107%, 납 보상체를 이용한 치료계획에서는 114~124%였다. 열형광선량계를 분석한 결과로 FIF에서는 104~107%, 납 보상체를 이용한 치료계획에서는 110~117%의 기준깊이 처방선량과의 선량차이가 나왔다. 결 론: 본 실험에서 인체모형등가팬텀에 양 팔을 제작하여 치료 계획 및 선량을 조사해 보았다. 양 팔의 투과 유무에 따라 약 7~17%의 선량차이가 발생 하였다. 4단계의 FIF 기법으로 3차원 치료계획을 수립하여 전신에 약 95~107%의 균등한 선량 분포를 확인하였고 ${\pm}10%$ 이내의 선량 균일성을 유지 할 수 있을 것으로 분석 되었다. FIF 기법을 이용한 3차원 치료 계획은 환자 전신에 조사되는 선량을 미리 분석 할 수 있는 치료 계획으로 기존 치료 방법보다 균등한 선량의 전달이 가능할 것으로 사료된다.

  • PDF

보존적 유방절제 환자의 방사선치료 시 종속조사면 병합방법에 따른 반대편 유방의 표면선량평가 (Evaluation of Contralateral Breast Surface Dose in FIF (Field In Field) Tangential Irradiation Technique for Patients Undergone Breast Conservative Surgery)

  • 박병문;방동완;배용기;이정우;김유현
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제31권4호
    • /
    • pp.401-406
    • /
    • 2008
  • 목적 : 종속조사면 병합 치료방법(FIF : Field In Field)을 이용한 유방절선조사 시 반대편 유방의 표면선량을 평가하고자 한다. 대상 및 방법 : FIF치료방법 이용 시 반대편 유방에 흡수되는 표면선량을 평가하고자 동일한 기하학적 조건과 처방선량을 기반으로 열린조사면(Open), 금속쐐기(MW : Metal Wedge), 동적쐐기(EDW : Enhanced Dynamic Wedge)를 이용한 조사방법과 비교하였다. 3차원 치료계획장치를 이용하여 선량분포 최적화를 수행하였으며 계산 결과의 정확도를 검증하기 위해 인체 팬톰과 모스펫 측정기를 사용하여 측정을 수행하였다. 동측 유방 입사면 가장자리로부터 반대편 유방 쪽으로 2, 4, 6, 8, 10cm 지점을 선정하여 각각 표면(0cm : 가피)과 0.5cm(진피) 깊이에서 선량을 측정하였으며, 0.5cm 깊이 선량측정을 위해서 0.5cm 볼루스를 사용하였다. 선량분포의 계산은 불균질 물질을 보정(modified Batho method)하여 0.25cm 격자 해상도로 수행하였다. 결과 : 치료계획장치에서 각 지점의 평균표면선량은 금속쐐기의 경우 표면 및 0.5cm 깊이에서 $19.6{\sim}36.9%$, $33.2{\sim}138.2%$ 증가했고, 동적쐐기는 $1.0{\sim}7.9%$, $1.6{\sim}37.4%$까지 증가하였다. FIF는 $-18.4{\sim}0.7%$, $-8.1{\sim}4.7%$까지 선량이 변화하였다. MOSFET을 이용하여 측정한 경우는 금속쐐기는 표면 및 0.5cm 깊이의 경우 $11.1{\sim}71%$, $22.9{\sim}161.2%$ 증가했고, 동적쐐기는 $4.1{\sim}15.5%$, $8.2{\sim}37.9%$ 선량이 증가했다. FIF는 표면에서 $-15.7{\sim}-4.9%$로 선량이 오히려 감소했으며, 0.5cm 깊이에서의 선량도 $-10.5{\sim}3.6%$로 나타났다. 치료계획장치의 계산값과 실측값을 비교한 결과, 유사한 경향을 보였으나 치료계획장치의 경우 피부선량이 실제측정값보다 다소 과소평가되고 있음을 알 수 있었다. 결론 : 본 실험을 통해 FIF치료방법의 경우 기존 치료방법(MW, EDW)에 비해 치료표적에 최적화 된 선량 분포를 만들어 내면서도 반대편 유방의 피부에 불필요한 산란선량을 최소화하는 치료방법임을 알 수 있었다.

  • PDF

Dosimetric Effects of Intrafractional Organ Motion in Field-in-Field Technique for Whole-Breast Irradiation

  • Hong, Chae-Seon;Ju, Sang Gyu;Choi, Doo Ho;Han, Youngyih;Huh, Seung Jae;Park, Won;Ahn, Yong Chan;Kim, Jin Sung;Lim, Do Hoon
    • 한국의학물리학회지:의학물리
    • /
    • 제30권3호
    • /
    • pp.65-73
    • /
    • 2019
  • Purpose: We evaluated the motion-induced dosimetric effects on the field-in-field (FIF) technique for whole-breast irradiation (WBI) using actual patient organ motion data obtained from cine electronic portal imaging device (cine EPID) images during treatment. Materials and Methods: Ten breast cancer patients who received WBI after breast-conserving surgery were selected. The static FIF (SFIF) plan involved the application of two parallel opposing tangential and boost FIFs. To obtain the amplitude of the internal organ motion during treatment, cine EPID images were acquired five times for each patient. The outside contour of the breast (OCB) and chest wall (CW) contour were tracked using in-house motion analysis software. Intrafractional organ motion was analyzed. The dynamic FIF (DFIF) reflecting intrafractional organ motion incorporated into the SFIF plan was calculated and compared with the SFIF in terms of the dose homogeneity index (DHI90/10) for the target and V20 for the ipsilateral lung. Results: The average motion amplitudes along the X and Y directions were 1.84±1.09 mm and 0.69±0.50 mm for OCB and 1.88±1.07 mm and 1.66±1.49 mm for CW, respectively. The maximum motion amplitudes along the X and Y directions were 5.53 and 2.08 mm for OCB and 5.22 and 6.79 mm for CW, respectively. Significant differences in DHI90/10 values were observed between SFIF and DFIF (0.94 vs 0.95, P<0.05) in statistical analysis. The average V20 for the lung in the DFIF was slightly higher than that of the SFIF in statistical analysis (19.21 vs 19.00, P<0.05). Conclusion: Our findings indicate that the FIF technique can form a safe and effective treatment method for WBI. Regular monitoring using cine EPID images can be effective in reducing motion-induced dosimetric errors.

유방암 절선조사 시 종속조사면 병합방법의 불균등한 선량분포 확인 (Verification of Non-Uniform Dose Distribution in Field-In-Field Technique for Breast Tangential Irradiation)

  • 박병문;배용기;강민영;방동완;김연래;이정우
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제33권3호
    • /
    • pp.277-282
    • /
    • 2010
  • 본 연구의 목적은 유방암 환자의 절선조사 시 종속조사면 병합(FIF) 치료방법을 2차원 이온전리함을 이용하여 불균등한 선량분포를 확인하고자하였다. 실험을 위해 2차원 이온전리함 배열(MatriXX, Wellhofer Dosimetrie, Germany)와 치료계획장치(Eclipse, ver 6.5, Varian, Palo Alto, USA)가 사용되었다. 불균등한 선량분포 확인을 위해 FIF 방법으로 치료계획 한 20명의 환자를 선택하여 각각 90 cGy를 처방하여 하이브리드계획을 수행하였으며, 측정값과 비교를 위해 동일한 기하학적 조건에서 MatriXX를 이용해 측정하였다. 정량적인 분석을 위해 상용화된 분석 소프트웨어(OmniPro IMRT, ver, 1.4, Wellhofer, Dosimetrie, Germany)를 이용하여 분석하였다. 실험 결과로 기준점에 선량처방 시 계산값과 측정값이 평균 1.6% 차이를 보였고, 선형프로파일(Line-Profile)을 통해 분석한 결과 종단면에서는 1.3-5.5%(평균 : 2.4%), 횡단면에서는 0.9-3.9%(평균 : 2.5%)로 변동을 보였다. 감마인덱스 히스토그람(기준 : 3 mm, 3%)로 분석한 결과 90.23-99.69%(평균 : 95.11%, 표준편차 : 2.81) 범위를 나타냈다(유효범위 ; $\gamma$-index $\geq$ 1). 본 실험에서는 MatriXX 이용하여 측정한 결과 치료계획 선량과 측정값이 오차범위 이내로 일치하였으며, 향후 다양한 종양치료에 있어 FIF방법의 활용도를 높이는 연구가 필요하다고 생각한다.

유방암 수술기법에 따른 방사선치료계획 기법의 선택 (Selection of radiation treatment plan technique at breast cancer operating technique)

  • 김정호;배석환;김기진;유세종
    • 대한안전경영과학회지
    • /
    • 제17권1호
    • /
    • pp.125-130
    • /
    • 2015
  • Techniques, using physical wedge filter and using dynamic wedge filter and FIF(Field in Field) and ISCT(Irregular Surface Compensating Technique), have been developed according to progress of radiation therapy of breast cancer. Measurement of dose was done to judge the usefulness of technique using three cases, non tissue loss after breast conserving operating and tissue loss after breast conserving operating and mastectomy. Dose indexes of breast tissue, CI (Conformity Index), HI (Homogeneity Index) and QOC (Quality of Coverage), dose index of skin, or dose indexes of lung, volume of 50 percent dose and 20 percent dose were estimated and compared. Using dynamic wedge filter is useful plan at non tissue loss allowing for high dose of lung. FIF and ISCT are useful plan at tissue loss. ISCT is useful plan at mastectomy. Henceforth, we need to apply to valid plan and body type and thorax size.

유방 부분 절제술 후 방사선 치료 시 TOMO Direct를 이용한 접선 조사의 선량적 유용성에 관한 고찰 (Evaluation of Tangential Fields Technique Using TOMO Direct Radiation Therapy after Breast Partial Mastectomy)

  • 김미정;김주호;김훈겸;조강철;전병철;조정희
    • 대한방사선치료학회지
    • /
    • 제23권1호
    • /
    • pp.59-66
    • /
    • 2011
  • 목 적: 유방 부분 절제술 후 방사선 치료 시 기존의 라이낙을 이용한 치료기법과 비교하여 TOMO Direct를 이용한 접선 치료 기법의 임상적 유용성을 알아보고자 한다. 대상 및 방법: 유방 부분 절제술 후 방사선 치료를 받은 좌측 유방암 환자 3명을 대상으로 라이낙을 이용한 쐐기 접선 조사 기법(Wedged tangential fields technique)과 조사면 내 선량 보강 기법(Field In Field technique, FIF), TOMO Direct, TOMO Direct 세기 변조 방사선 치료(Intensity Modulated Radiation Therapy, IMRT)기법을 이용하여 동일한 처방 조건(CTV 내 $D_{90%}$: 50.4 Gy/28 fx)으로 치료계획을 수립하였다. 선량 분석을 위해 선량 체적 히스토그램(Dose Volume Histogram, DVH)과 등선량 곡선 (Isodose curve)을 이용하여 종양 내 표적체적(Clinical Target Volume, CTV)과 손상위험장기(Organ At Risk, OAR)에 대한 선량을 비교분석 하였다. 표적체적의 선량 인자로는 $D_{99}$, $D_{95}$, 선량 균일 지수(Dose homogeneity index, DHI: $D_{10}/D_{90}$)와 $V_{105}$, $V_{110}$을 손상위험장기의 선량 인자로는 심장의 $V_{10}$, $V_{20}$, $V_{30}$, $V_{40}$과 좌측 폐의 $V_{10}$, $V_{20}$, $V_{30}$을 비교 분석하였다. 결 과: 표적체적의 선량 분석 결과로 $D_{99}$, $D_{95}$의 평균값은 각각 쐐기 접선 조사(W)에서 $47.7{\pm}1.1Gy$, $49.4{\pm}0.1Gy$이었으며, 조사면 내 선량 보강 기법(F)은 각각 $47.1{\pm}0.6Gy$, $49.2{\pm}0.4Gy$, 그리고 TOMO Direct(D)와 TOMO Direct IMRT(I)에서는 각각 $49.2{\pm}0.4$ vs. $48.6{\pm}0.8Gy$, $49.9{\pm}0.4$ vs. $49.5{\pm}0.3Gy$이었다. 선량 균일 지수의 평균값은 W: $1.1{\pm}0.02$, F: $1.07{\pm}0.02$, D: $1.03{\pm}0.001$, I: $1.05{\pm}0.02$이었다. 각각의 치료 기법으로 $V_{105}$, $V_{110}$의 평균값을 비교하였을 때 쐐기 접선 조사 시 각각 $34.6{\pm}9.3%$, $7.5{\pm}7.9%$로 가장 높았고 조사면 내 선량 보강 기법은 $16.5{\pm}14.8%$, $2.1{\pm}3.5%$로, TOMO direct IMRT는 $7.5{\pm}8.3%$, $0.1{\pm}0.1%$로 낮아졌으며 TOMO direct에서는 두 값 모두 0%로 나타났다. 손상 위험 장기에 대한 선량 분석 결과 각각의 치료 기법 사이에 유의한 차이를 보이지 않았다. 결 론: TOMO Direct를 이용한 접선 조사 기법은 기존의 쐐기 접선 치료 기법보다 치료 용적 내에 균일한 선량분포를 얻을 수 있을 뿐만 아니라 IMRT 또는 Tomotherapy와 달리 정상조직의 저 선량 영역의 노출용적을 증가시키지 않았으며 조사면 내선량 보강 기법 보다 용이한 치료계획 절차를 수행하므로 유방 부분 절제술 후 방사선 치료 시 임상적으로 유용하리라 사료된다.

  • PDF

유방암 접선조사 치료 방법에 대한 반대쪽 유방에서의 산란선량 평가 (Evaluation of Scattered Dose to the Contralateral Breast by Separating Effect of Medial Tangential Field and Lateral Tangential Field: A Comparison of Common Primary Breast Irradiation Techniques)

  • 반태준;전수동;곽정원;백금문
    • 대한방사선치료학회지
    • /
    • 제24권2호
    • /
    • pp.183-188
    • /
    • 2012
  • 목 적: 암치료 기술의 발전으로 환자의 생존기간이 길어짐에 따라 치료 이후 삶의 질을 증진하고 치료 방법에 의한 부작용을 줄이는 노력에 관심이 집중되고 있다. 본 연구는 유방암 접선조사 치료에서 치료방법 차이가 반대쪽 유방 산란 선량에 미치는 영향을 분석하고자 하였다. 대상 및 방법: 본원에서 제작한 유방 모형 팬텀의 전산화 단층 영상을 이용하여 이클립스 10.0 (Eclipse 10.0, Varian, USA) 치료계획 시스템을 사용하여 $30^{\circ}$ wedge plan, $15^{\circ}$ wedge plan, $30^{\circ}$ EDW (Enhanced dynamic wedge) plan, Non-wedge plan, FIF(Field in Field) plan을 수립하였다. 각 치료계획은 선형가속기 CL-6EX (VARIAN, USA)를 이용하여 400 cGy씩 조사하였고 팬텀의 중심점으로부터 횡축방향으로 1 cm, 3 cm, 5 cm, 9 cm 씩 이동한 지점의 1 cm 깊이에서 전리조(FC 65G, IBA)를 이용하여 내측접선(Medial tangential) 조사와 외측접선(Lateral tangential) 조사에서 발생하는 산란선량을 각각 측정하고 비교 분석하였다. 결 과: 반대쪽 유방 산란 선량을 평가해보았을 때 $30^{\circ}$ wedge plan, $15^{\circ}$ wedge plan, $30^{\circ}$ EDW (Enhanced dynamic wedge) plan, Non-wedge plan, FiF (Field in Field) plan에서 처방선량에 대해 각각 6.55%, 4.72%, 2.79%, 2.33%, 1.87%로 나타났다. 내측접선조사와 외측접선 조사로 나누어 보았을 때 내측접선 조사 측정값은 각각 4.94%, 3.33%, 1.55%, 1.17%, 0.77%로 나타났고 외측접선 조사는 각각 1.61%, 1.40%, 1.24%, 1.16%, 1.10%의 산란 선량이 측정되었다. 결 론: 유방암 접선 조사 치료방법 중 반대쪽 유방에 가장 적은 산란 선량이 발생하는 방법은 FiF plan으로 이때 발생한 산란선량은 팬텀 내에서 기인한 선량이 주로 작용하는 것으로 판단되었다. 가장 많은 산란 선량이 발생하는 치료방법은 $30^{\circ}$ wedge plan이었고 쐐기필터를 비롯한 치료 장비에서 기인한 선량은 3.3%로 평가되었다. 치료계획 시스템은 처방선량에 대해 상대적으로 낮은 산란 선량 영역은 정확성이 떨어지는 것으로 나타났다. 치료 조사야 밖으로 발생하는 산란 선량은 처방 선량에 비해 그 양이 적지만 2차 암 발생 확률과 관련이 있다는 점에서 간과할 수 없는 부분이며 방사선 치료를 결정하는데 있어 고려되어야 할 부분으로 사료된다.

  • PDF