• Title/Summary/Keyword: Field testing equipment

Search Result 123, Processing Time 0.027 seconds

Introduction of the field - test evaluation system in KEPCO (배전 실증시험장 시스템 현황 소개)

  • Kim, Dong-Myung;Choi, Sun-Kyu;Jang, Sang-Ok;Oh, Jae-Hyoung
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.81-85
    • /
    • 2004
  • This paper describes the testing facility to demonstrate the performance of the distribution class circuit breakers and switchgears and the testing methods. The field-test evaluation system consists of two parts. One is the distribution system for simulation of the condition on interruption mode of switches which are installed in the system and tested by the AFG(Artificial Fault Generator) and the thunderbolt generator just like in the real field. The other is a laboratory for confirmation or the important characteristics regarding to the insulation, gas, environment durability of equipment. For the fatal failure mode, a FMEA(Failure Modes and Effects Analysis) technique which is a kind of a structural analysis to consider a counter-plan was emploved.

  • PDF

Compact near-eye display for firefighter's self-contained breathing apparatus

  • Ungyeon Yang
    • ETRI Journal
    • /
    • v.45 no.6
    • /
    • pp.1046-1055
    • /
    • 2023
  • We introduce a display for virtual-reality (VR) fire training. Firefighters prefer to wear and operate a real breathing apparatus while experiencing full visual immersion in a VR fire space. Thus, we used a thin head-mounted display (HMD) with a light field and folded optical system, aiming to both minimize the volume for integration in front of the face into a breathing apparatus and maintain adequate visibility, including a wide viewing angle and resolution similar to that of commercial displays. We developed the optical system testing modules and prototypes of the integrated breathing apparatus. Through iterative testing, the thickness of the output optical module in front of the eyes was reduced from 50 mm to 60 mm to less than 20 mm while maintaining a viewing angle of 103°. In addition, the resolution and image quality degradation of the light field in the display was mitigated. Hence, we obtained a display with a structure consistent with the needs of firefighters in the field. In future work, we will conduct user evaluation regarding fire scene reproducibility by combining immersive VR fire training and real firefighting equipment.

Accelerated Weathering Test of Urethane Paint for Heavy Construction Equipment (중장비용 우레탄 도료 내후성 가속시험)

  • 김대용;김영준
    • Journal of Applied Reliability
    • /
    • v.1 no.2
    • /
    • pp.79-93
    • /
    • 2001
  • Recently, new aspects of paints such as a beautiful appearance, use of environmentally friendly paints, etc., in addition to the superior performance of paints have been requested for industrial paints including the paints for heavy construction equipment and others. Particularly, the quality of appearance of coating affects the sales of heavy construction equipment. And the necessity for the paints to have a superior weather-proof property without changing the luster or color even after long-time exposure to the open air is emphasized. The change in the surface color and luster of the paint due to the natural environment progresses very slowly, and it takes a long time to verify material properties when developing new paints. In order to improve such methods, weathering tests are performed in many laboratories as a test for accelerating aging of coating, and the lifetime of the products is estimated through evaluation of the weathering (environment-proof) quality of paints. However, not a great deal of research activity has been conducted up to the present time since the interrelationship between the actual results of testing and field data is different for each paint and it takes a long time to study relevant materials. Therefore, introduced in the present study is the estimation of the change in the quality of appearance of coating in the field through the accelerated aging test among the cases of improvement of the quality of appearance of the urethane paint for heavy construction equipment.

  • PDF

Implementation of ATE to Maintain Pre-Amplifier of Thermal Imaging System (열상장비 전단증폭부 정비용 ATE의 구현)

  • Park, Jai-Hyo;Kim, Han-Kyung
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.49 no.1
    • /
    • pp.80-87
    • /
    • 2012
  • We have developed the ATE(Automatic Test Equipment) system for the performance test of pre-amplifier of thermal imaging devices. The device regenerates the electronic signals of photon detection module which is normally in weak energy, for the image signals processing. Previous ATE system was primarily and actively developed in the field of semiconductor devices quality parts inspection. Recently, it has been studied in the field of performance testing of equipment. In the field of thermal performance test equipment, however, it lacks the study of ATE compared to other areas, which causes the maintenance related to the core of military thermal imaging system maintenance to be limited. In this paper, a new study of ATE in the field of thermal imaging system is done. It is designed to be used universally for the ATE system with different types of circuit card of thermal imaging system by adopting matrix relays. Using the developed ATE measuring the pre-amplifier amplitude, an average amplified amplitude of 2.71Vpp was measured which confirms that it is within the range of theoretical analysis and also verifies the good performance of the developed ATE.

Development of Remote Field Eddy Current Pipeline Inspection System (원격장 와전류 배관 탐상 시스템 개발)

  • Jeong, Jin-Oh;Yi, Jae-Kyung;Kim, Hyoung-Jean
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.21 no.5
    • /
    • pp.556-560
    • /
    • 2001
  • Remote field eddy current testing (RFECT) with through-wall transmission characteristic is being applied to pipes ranging from small tubes of heat exchanger to natural gas supply pipelines. Cast iron pipes with nominal diameter of 100mm are used primarily as the waterline pipes. The leakage of water occurs due to defects in the pipes caused by vibration of automobiles and corrosion. But, the use of direct inspection methods such as insertion of inspection equipment inside the pipelines has been limited due to its lack of economical efficiency. Economical development of inspection equipments is possible since RFECT method can be easily employed for system integration and quantitative evaluation of both inside and outside defects. In this study, the development of underground pipeline inspection system was tarried out by using RFECT method in consideration of the characteristics of waterline network. This paper specifically describes the design and production of RFECT pipeline inspection pig using centralizer mechanism, development of remote field eddy current signal acquisition and processing software, and review of RFECT system operation procedures.

  • PDF

Component and Bench Tests of Polyurethane Hydraulic Reciprocating Seal for Accelerated Life Testing (부품 및 벤치 실험을 통한 폴리우레탄 유압 왕복 실의 가속 실험)

  • Je, Youngwan;Kim, Hansol;Kim, Lyu-Woon;Chung, Koo-Hyun;An, Joong-Hyok;Jeon, Hong-Gyu
    • Tribology and Lubricants
    • /
    • v.30 no.5
    • /
    • pp.271-277
    • /
    • 2014
  • Hydraulic reciprocating seals have been widely used to prevent fluid leakage and to provide lubricant film on counter surface in various hydraulic system. The degradation of the seal may cause the catastrophic failure of the hydraulic system. To assess the durability of the seals and the compatibility with counter surface, accelerated life testing (ALT) has been typically employed from industry. However, ALT often takes up to a few months to cause a failure of the seals, and therefore, there is a need to develop more efficient ALT methods. In this work, the degradation characteristics of polyurethane (PU) seals from field test are investigated and they are compared to those from the component and bench tests, with an aim to contribute to the development of ALT method. From the comparison of the cross-sectional profiles of the sealing surface of the PU specimens before and after the tests, both wear and compression set are found to be responsible for degradation of the PU seals. It is also shown that the major wear mechanisms of the PU seals from the field is abrasive wear and formation of pits. The component and bench tests performed in this work are shown to reproduce such wear mechanisms, and therefore, those test methods can be used as an ALT method for PU seals. In particular, the bench test proposed in this work may be effectively utilized to assess the durability and the compatibility of the seals with the counter surface. The results of this work are expected to aid in the design of ALT for PU seal.

The Application of Standard in According to Ground and Electrical Continuity Testing of Lightning Protection Equipment in Field (피뢰설비현장의 접지 및 전기적 연속성 시험에 따른 표준적용)

  • Song, Gil-Mok;Koo, Kyung-Wan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.4
    • /
    • pp.583-588
    • /
    • 2014
  • In this study, there are examined to the grounding of lightning protection system and electrical continuity tests in the field. The standard for lightning protection system is different design or construction according to the characteristics of the structure. Ground is measured and compared at least four locations. According to the measured results in the field, the sampled values of the ground resistance are measured $5{\Omega}$ or less and the difference between each value is suitable as $0.2{\Omega}$ or less. The values of the electrical continuity test between ground and metal bodies are measured 3 groups such as isolated portion, the mechanical contacted portion, and the electrical continuity portion measuring $0.2{\Omega}$ or less. It is measured to be less than $0.2{\Omega}$ at all in metal bodies of underground. A metal body installed inside the structure is not isolated, but the resistance values are higher than $0.2{\Omega}$. Therefore, It must be carried out the structure having lightning protection system confirm the LPL(lightning protection level) and design the strategy.

The Shock-Test Result and Analysis Using Dual-Pulse Shock Testing Machine (이중충격파형 충격시험장비를 이용한 충격시험 결과 및 분석)

  • Bae, Jongsoo
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.21 no.3
    • /
    • pp.342-348
    • /
    • 2018
  • The important issue of equipment installed in maritime weapon system is shock survivability against underwater explosion(UNDEX). If the shock survivability of equipment should not be guaranteed, the successful mission also could not be achieved. For that reason, the shock-resistance of each equipment under UNDEX environment should be demonstrated before deployment at combat field. However, the actual UNDEX test on the ocean is too expensive to conduct. Also, it has diverse dangerous factors. The main characteristic of UNDEX is a dual-pulse shock. The vertical shock test machine able to simulate dual pulse shock signal on the ground will be introduced in this paper. The dual-pulse shock signal presented in certain shock standard was achieved with this shock-test machine on the ground. The analytical procedure to set a test condition was verified by comparing simulation result with experiment result.

Calibration of Detection System of Crack in Concrete Structure by Using Image Processing Technology

  • Kim, Su-Un;Shin, Sung-Woo;Park, Jeong-Hak;Choi, Man-Yong
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.31 no.6
    • /
    • pp.626-634
    • /
    • 2011
  • The investigation of concrete structure typically relies on visual inspection which is one of the basic inspection techniques. Image processing techniques play a crucial role in the growing field of automatic surface inspection technique. However, kinds of inspection equipment, environmental condition and detection algorithm have much influence on the reliability of inspection result. This paper proposes a verification method and testing procedure for the reliability of inspection results and surveys characteristics of image acquisition systems and crack inspection algorithms.

Improvement Scheme of Field Uniformity of Stirrer Parameter in Reverberation Chamber (전자파 잔향실의 교반기 매개변수에 따른 전계 균일도 향상 방안)

  • Kim, Kwang-Yong;Hong, Joo-Il;Han, Seung-Moon;Doo, Jin-Suk;Huh, Chang-Su;Lee, Ki-Taek
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1583_1584
    • /
    • 2009
  • Reverberation chamber have become a common tool in radiated susceptibility and emission testing of electronic equipment. In a reverberation chamber, internal electromagnetic fields are mixed by metallic stirrer. Due to elimination of Polarization characteristic in reverberation chamber, electromagnetic wave reached to EUT all aspect angle. Hence, Field distribution in overmode reverberation chamber can be presented by chi-square distribution. Field uniformity in reverberation chamber have to satisfy standard deviation below 3dB and is influenced by mechanical stirrer. This paper investigates relationship between change of stirrer parameter and field uniformity in reverberation chamber.

  • PDF