• 제목/요약/키워드: Field seismic test

검색결과 158건 처리시간 0.029초

HWAW방법을 사용한 지반의 전단파 속도 2-D 영상화 (Two-dimensional imaging of shear wave velocity in the soil site using HWAW method)

  • 박형춘;김동수;김종태;박헌준;방은석
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 춘계 학술발표회 초청강연 및 논문집
    • /
    • pp.7-13
    • /
    • 2008
  • To obtain a shear-wave velocity profile in geotechnical practice, various seismic investigation methods which have their own strength and weakness are being frequently used. Generally, geotechnical site have lateral variation of the properties, so it is needed to determine 2-dimensional shear wave velocity imaging of the site. In this study, harmonic wavelet analysis of wave (HWAW) method is applied to determination of 2-D $V_s$ imaging. HWAW method which is based on time-frequency analysis using harmonic wavelet transform have been developed to determine phase and group velocities of waves. HWAW method uses the signal portion of the maximum local signal/noise ratio to evaluate the phase velocity to minimize the effects of noise. HWAW method determine detailed local $V_s$ profile because one experimental setup which consists of one pair of receivers with spacing of 1~3m is used to determine the dispersion curve of the whole depth. So, 2-D Vs imaging with relatively high resolution can be determined through a series of HWAW test. In order to estimate the applicability of HWAW method, field tests were performed in 4 sites. Through field applications and comparison with other test results, the good accuracy and applicability of the proposed method were verified.

  • PDF

발파실험과 내진해석을 통한 Anchor의 동적 저항성에 관한 연구 (Dynamic Resistance of Anchor using Blasting Test and Numerical analysis for Earthquake)

  • 최경집;조국환
    • 한국철도학회논문집
    • /
    • 제20권4호
    • /
    • pp.500-511
    • /
    • 2017
  • 최근 경주지진이 일어나게 되면서 지진의 진동에 의한 구조물의 안정성에 대한 관심이 증가하고 있다. 하지만 국내 앵커분야의 경우 설계하중에 대한 안정성만 고려하고 있을 뿐 진동에 대한 안정성에 대한 연구는 미미한 실정이다. 마찰형 앵커의 경우 시공 중 발생하는 발파진동 등으로 인하여 앵커의 저항능력을 상실한 경우가 종종 보고되고 있다. 이에 반하여 지압형 앵커의 경우 구조적으로 마찰형 앵커에 비하여 진동저항능력이 우수할 것으로 판단되나 이러한 특성에 대한 연구는 거의 진행되지 않았다. 본 연구에서는 새롭게 개발한 지압형 앵커의 발파진동과 지진에 대한 안정성을 검증하기 위하여 현장시험을 수행하였으며 수치해석을 통하여 내진안정성을 검증하였다. 그 결과 현장시험의 경우에는 마찰형 앵커보다 발파진동에 대한 저항성능이 우수하였으며, 수치해석을 이용한 내진해석의 경우 또한 마찰형 앵커에 비하여 저항성능이 우수한 것으로 분석되었다.

Relationship between hardness and plastically deformed structural steel elements

  • Nashid, Hassan;Clifton, Charles;Ferguson, George;Hodgson, Micheal;Seal, Chris;Choi, Jay-Hyouk
    • Earthquakes and Structures
    • /
    • 제8권3호
    • /
    • pp.619-637
    • /
    • 2015
  • A field based non-destructive hardness method is being developed to determine plastic strain in steel elements subjected to seismic loading. The focus of this study is on the active links of eccentrically braced frames (EBFs). The 2010/2011 Christchurch earthquake series, especially the very intense February 22 shaking, which was the first earthquake worldwide to push complete EBF systems into their inelastic state, generating a moderate to high level of plastic strain in EBF active links for a range of buildings from 3 to 23 storeys in height. Plastic deformation was confined to the active links. This raised two important questions: what was the extent of plastic deformation and what effect does that have on post-earthquake steel properties? A non-destructive hardness test method is being used to determine a relationship between hardness and plastic strain in active link beams. Active links from the earthquake affected, 23-storey Pacific Tower building in Christchurch are being analysed in the field and laboratory. Test results to date show clear evidence that this method is able to give a good relationship between plastic strain and demand. This paper presents significant findings from this project to investigate the relationship between hardness and plastic strain that warrant publication prior to the completion of the project. Principal of these is the discovery that hot rolled steel beams carry manufacturing induced plastic strains, in regions of the webs, of up to 5%.

상시 진동을 이용한 댐 수문의 동특성 추정 (Estimation of Dynamic Characteristics of Existing Dam Floodgate Using Ambient Vibration)

  • 김남규;이종재;배정주
    • 비파괴검사학회지
    • /
    • 제31권4호
    • /
    • pp.343-350
    • /
    • 2011
  • 최근 전세계적으로 큰 지진이 빈번히 발생하고 있고, 국내에서도 지진 발생 빈도가 높아짐에 따라 노후화된 토목 구조물에 대한 내진 성능 평가 및 구조 건전성 평가의 중요성이 재조명되고 있다. 하지만 국내 기존 댐 수문에 대한 관련 연구는 미비한 실정이다. 본 연구에서는 댐 수문 내진 성능 평가 및 구조 건전성 평가의 기초자료가 펴는 댐 수문의 통특성 추정을 위하여 댐 수문에 적용할 수 있는 실험기법을 정립하고, 정립된 실험기법을 통하여 두 종류의 댐 수문에 대한 현장 실험을 수행하였다. 동특성 추정에는 모드 해석 방법 중에 하나인 주파수영역분해기법을 이용하였다. 상시진동실험과 강제진동실험을 이용하여 댐 수문의 동특성을 추정함으로써 두 방법의 성능을 비교하였으며, 상시진동실험이 댐 수문의 동특성을 추정하는데 매우 효과적인 방법임을 확인하였다.

각형강관 기둥-H형강 보 신형상 내진접합부의 실험적 평가 (Experimental Evaluation of New Seismic Connections between Rectangular Steel Tube Column and H-shaped Beam)

  • 진주호;김두환;김현숙;신진원;박구연;이경구
    • 한국강구조학회 논문집
    • /
    • 제30권2호
    • /
    • pp.77-85
    • /
    • 2018
  • 각형강관 기둥을 이용한 모멘트 접합부는 주로 관통형 다이어프램 형식으로 사용되고 있으나, 제작 및 시공과정이 복잡하여 적용하는데 어려움이 있다. 본 연구에서 제안하는 강구조물 시스템은 단위 유닛 모듈(각형강관 기둥, H형강 보, 원웨이 볼트)을 현장으로 반입하여 볼트조립만으로 완성되는 것이다. 따라서 이 연구에서는 내부보강판의 길이, 내부보강판의 형상을 변수로 설정하여 제안된 기둥-보 접합부의 내력 및 강성, 연성능력, 에너지 소산능력을 비교 분석하여 제시된 강구조물 시스템을 평가하였다.

내진 각형강관 기둥-H형강 보 접합상세의 구조성능평가 (Structural Performance Evaluation of Seismic Wide-flanged Beam-to-Rectangular Steel Tube Column Connection Details)

  • 장보라;심현주;김용익;정진안;오영석;김상섭;최병정;이은택
    • 한국강구조학회 논문집
    • /
    • 제22권4호
    • /
    • pp.305-312
    • /
    • 2010
  • 본 연구의 목적은 모멘트 접합 골조에서 각형강관 기둥-H 형강 보 접합부의 내진성능평가이다. 각형강관은 H형강에 비해서 효율적이고 많은 장점이 있음에도 불구하고, 아직 접합 디테일의 부족과 경험 부족 등의 이유로 현장에서 적용이 제한적이다. 각형강관을 사용한 기존의 모멘트 접합부는 주로 관통형 다이아프램 형식을 사용하고 있는데 이는 시공과정이 복잡하여 현장에서의 적용을 어렵게 한다. 그러므로 이 연구에서는 각형강관 기둥을 절단하지 않는 접합상세에 대하여 구조성능 및 내진성능을 평가하고자 하였다. 엔드플레이트와 헌치를 이용한 용접접합의 접합상세에 대하여 내력 및 강성, 에너지흡수능력을 비교분석하였다.

TEMPORAL VARIATIONS OF THE GLOBAL SEISMIC PARAMETERS OF HD 49933 OVER A MAGNETIC CYCLE

  • Kim, Ki-Beom;Chang, Heon-Young
    • 천문학회지
    • /
    • 제54권4호
    • /
    • pp.129-137
    • /
    • 2021
  • It has been established that the acoustic mode parameters of the Sun and Sun-like stars vary over activity cycles. Since the observed variations are not consistent with an activity-related origin, even Sun-like stars showing out-of-phase changes of mode frequencies and amplitudes need to be carefully studied using other observational quantities. In order to test whether the presumed relations between the global seismic parameters are a signature of the stellar activity cycle, we analyze the photometric light curve of HD 49933 for which the first direct detection of an asteroseismic signature for activity-induced variations in a Sun-like star was made, using observations by the CoRoT space telescope. We find that the amplitude of the envelope significantly anti-correlates with both the maximum frequency of the envelope and the width of the envelope unless superflare-like events completely contaminate the light curve. However, even though the photometric proxy for stellar magnetic activity appears to show relations with the global asteroseismic parameters, they are statistically insignificant. Therefore, we conclude that the global asteroseismic parameters can be utilized in cross-checking asteroseismic detections of activity-related variations in Sun-like stars, and that it is probably less secure and effective to construct a photometric magnetic activity proxy to indirectly correlate the global asteroseismic parameters. Finally, we seismically estimate the mass of HD 49933 based on our determination of the large separation of HD 49933 with evolutionary tracks computed by the MESA code and find a value of about 1.2M and a sub-solar metallicity of Z = 0.008, which agrees with the current consensus and with asteroseismic and non-asteroseismic data.

Mechanical performance analysis of an electromagnetic friction pendulum system based on Maxwell's principle

  • Mao Weikang;Li Xiaodong;Chen Enliang
    • Earthquakes and Structures
    • /
    • 제27권2호
    • /
    • pp.143-154
    • /
    • 2024
  • Friction pendulums typically suffer from poor uplift-restraining. To improve the uplift-restraining and enhance the energy dissipation capacity, this article proposed a composite isolation device based on electromagnetic forces. The device was constructed based on a remote control system to achieve semi-active control of the composite isolation device. This article introduces the theory and design of an electromagnetic chuck-friction pendulum system (ECFPS) and derives the theoretical equation for the ECFPS based on Maxwell's electromagnetic attraction equation to construct the proposed model. By conducting 1:3 scale tests on the electromagnetic device, the gaps between the practical, theoretical, and simulation results were analyzed, and the accuracy and effectiveness of the theoretical equation for the ECFPS were investigated. The hysteresis and uplift-restraining performance of ECFPS were analyzed by adjusting the displacement amplitude, vertical load, and input current of the simulation model. The data obtained from the scale test were consistent with the theoretical and simulated data. Notably, the hysteresis area of the ECFPS was 35.11% larger than that of a conventional friction pendulum. Lastly, a six-story planar frame structure was established through SAP2000 for a time history analysis. The isolation performances of ECFPS and FPS were compared. The results revealed that, under horizontal seismic action, the horizontal seismic response of the bottom layer of the ECFPS isolation structure is greater than that of the FPS, the horizontal vibration response of the top layer of the ECFPS isolation structure is smaller than that of the FPS, and the axial force at the bottom of the columns of the ECFPS isolation structure is smaller than that of the FPS isolation structure. Therefore, the reliable uplift-restraining performance is facilitated by the electromagnetic force generated by the device.

고속철도 교량의 현장실험 및 감쇠비 개선에 따른 공진 시 동적응답의 분석 (Field Tests and Resonance Behavior Corresponding to the Damping Ratio of a High Speed Railroad Bridge)

  • 김성일;김현민;박동욱
    • 한국철도학회논문집
    • /
    • 제16권4호
    • /
    • pp.305-310
    • /
    • 2013
  • 고속철도 교량에서는 상업 운행 중에는 대부분 통과속도가 일정하여 속도별 동적 거동에 대한 실험적 계측 및 분석이 불가능하다. 경부고속철도 2단계 개통 전 시운전 시 KTX 열차의 속도별 시운전이 가능하였으며, 속도별 운행에 대한 교량의 동적응답 계측이 가능하였다. 이 계측 결과는 개발된 교량/열차 상호작용해석에 대한 검증 및 비교 분석으로 연계될 수 있었다. 대부분의 속도대역에서 해석과 실험에 의한 결과가 잘 일치함을 알 수 있었으나, 공진이 발생하는 임계속도 부근 주행에서는 상대적으로 큰 응답 차이가 발생하였다. 본 논문에서는 이에 대한 원인 분석을 수행하였으며, 공진 발생 시 감쇠비 값을 측정 시 응답을 통해 재추정한 결과를 반영한 재해석을 수행하였다.

울릉분지 가스하이드레이트 2/3차원 탄성파 탐사자료 취득 및 품질관리 (2-D/3-D Seismic Data Acquisition and Quality Control for Gas Hydrate Exploration in the Ulleung Basin)

  • 구남형;김원식;김병엽;정순홍;김영준;유동근;이호영;박근필
    • 지구물리와물리탐사
    • /
    • 제11권2호
    • /
    • pp.127-136
    • /
    • 2008
  • 울릉분지에서 가스하이드레이트 부존 유망지역 파악을 위하여 2005년과 2006년에 탐해2호를 사용하여 2차원 및 3차원 탄성파 탐사를 수행하였다. 탐사장비는 항측시스템, 기록시스템, 스트리머 케이블, 음원 등으로 구성되었다. 주로 1,000 m 이상의 대수심 환경 및 해저면 하부 500 msec 구간에서의 속도분석의 신뢰도를 고려하여, 3 km 길이의 스트리머와 1,035 $in^3$ 용량의 동조 에어건 음원을 사용하였다. 현장탐사자료취득과정에서 음원파형분석, 2차원 저급중합, RMS 잡음 분석, 주파수-파수 스펙트럼 분석 등의 일련의 품질관리를 수행하였다. 음원의 품질기준 적합성을 검토하기 위하여 음원파형을 계산하고, 건제거시험을 통하여 에어건 고장시의 음원파형변화를 확인하였다. 실시간 품질 분석을 통하여 일부 탄성파 자료에서 너울잡음, 패러티 오류, 스파이크 잡음 및 조목잡음 등을 확인할 수 있었지만, 탐사자료의 품질이 전반적으로 양호함을 확인할 수 있었다. 특히 3차원 탐사 시 불가피한 현장상황에 의해 조목잡음의 영향을 받은 탐사자료에 대해 FK 필터링 및 누락 트레이스 복원 기법을 적용한 품질향상 결과를 제시함으로써 취득자료의 적합 판정 및 현장 탐사 지속이 결정될 수 있었다. 탐사자료가 품질기준을 벗어나는 탐사해역에서도 현장자료처리를 통하여 잡음제거 가능성을 제시함으로써 해양탄성파탐사의 효율성을 높일 수 있다.