• Title/Summary/Keyword: Field plate

Search Result 1,547, Processing Time 0.031 seconds

Case study on hydroelastic vibration of plate for various bounded fluid field (유체장 변화에 따른 사각형 탱크의 진동에 관한 연구)

  • Kim, K.S.;Choi, S.H.;Jo, H.D.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.855-860
    • /
    • 2006
  • In this paper, a numerical case study is carried out on the hydroelastic vibration of rectangular plate with various fluid field. It is assumed that the tank wall is clamped along the plate edges. The VMM(Virtual Mass Method) of Nastran is used for the simulation of fluid domain and calculating natural frequency of fluid-coupled structure. In this paper, natural frequencies are calculated and compared for rectangular plates with various fluid field such as infinite fluid and finite fluid, length change of finite fluid field and various fluid contacting conditions.

  • PDF

Simulation of Magnetic Field and Removal Characteristic of Nitrogen Oxide Using Wire-Plate Type Plasma Reactor (선 대 평판형 플라즈마 반응기를 이용한 자계 시뮬레이션과 질소산화물제거 특성)

  • 이현수;박재윤
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.52 no.9
    • /
    • pp.407-411
    • /
    • 2003
  • The purpose of this paper is to study the removal of nitrogen oxide(NOx) using a wire-plate type plasma reactor with magnet attached for indoor air purification. In order to produce a more effective reactor, we conducted magnetic field simulations. The results of the magnetic field simulations show that NOx can be removed more effectively. The results from the magnetic field simulation show that when 7 magnets were applied to the reactor, the magnetic flux density was at its highest amount than when using 0, 3, or 5 magnets. From the data obtained by the simulation results a plasma reactor was made and thus, several experiments were conducted. The best removal efficiency was obtained with 14 W AC power to the reactor with 5 magnets.

Case Study on Hydroelastic Vibration of Plate for Various Bounded Fluid Field (유체장 변화에 따른 사각형 탱크의 진동에 관한 연구)

  • Choi, S.H.;Jo, H.D.;Kim, K.S.
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.17 no.1 s.118
    • /
    • pp.3-9
    • /
    • 2007
  • In this paper, a numerical case study is carried out on the hydroelastic vibration of rectangular plate with various fluid field. It is assumed that the tank wall is clamped along the plate edges. The VMM(virtual mass method) of Nastran is used for the simulation of fluid domain and calculating natural frequency of fluid-coupled structure. In this paper, natural frequencies are calculated and compared for rectangular plates with various fluid field such as infinite fluid and finite fluid, length change of finite fluid field and various fluid contacting conditions.

Electrical Characteristics Analysis According to Electrode Shape and Distance Between Electrodes (전극 형태와 전극 간 거리에 따른 전기적 특성 분석)

  • Tae-Hee Kim;Soon-Hyung Lee;Mi-Yong Hwang;Yong-Sung Choi
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.36 no.4
    • /
    • pp.408-412
    • /
    • 2023
  • In this paper, in order to analyze high electrical insulation and cooling performance using mineral oil, the liquid insulating oil was changed in electrode shape and distance between electrodes to compare and analyze electrical characteristics according to equal electric field, quasi-equivalent electric field, and unequal electric field. As a result, the breakdown voltages were 36,875 V and 36,875 V in the form of sphere-sphere and plate-plate electrodes with equal electric fields. The breakdown voltage was 31,475 V in the sphere-plate electrode type, which is a quasi-equilibrium field, and the breakdown voltage was 28,592 V, 27,050 V, and 22,750 V in the needle-needle, sphere-needle, and needle-plate electrode types, which are unequal fields. Through this, it is possible to know the difference in breakdown voltage according to the type of electric field. The more equal the field, the higher the breakdown voltage, and the more unequal field, the lower the breakdown voltage. The difference in insulation breakdown voltage could be seen depending on the type of electric field, the insulation breakdown voltage was higher for the more equal electric field, and the insulation breakdown voltage was lower for the more unequal electric field. Also, it was confirmed that the closer the distance between the electrodes, the higher the insulation breakdown voltage, the higher the insulation breakdown current, and the insulation breakdown voltage and the insulation breakdown current were proportional.

Reduction Characteristics of Electromagnetic Penetration through a Slit in a Conducting Screen by a Loaded Triangle Plate (삼각형 도체판 장하에 의한 무한 도체 평판 슬릿의 침투 전자파 저감 특성)

  • Cho, Byung-Ho;Lee, Seung-Ik;Kim, Hyo-Kyun;Kim, Ki-Chai
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.7
    • /
    • pp.767-773
    • /
    • 2014
  • This paper presents the reduction characteristics of electromagnetic penetration through a slit in conducting screen by loaded plate. The FDTD method is used in theoretical analysis. And the characteristics of penetrated electric fields are calculated in terms of length, width, shape, position, and height of the loaded plate to find out how the geometry of plate influences the reduction characteristics of the electromagnetic penetration and shielding effectiveness. The results show that the characteristics of penetrated electric field and shielding effectiveness depend on the geometry of loaded plate. In particular, the optimal geometry of loaded plate which minimize penetrated electric field are verified.

Reduction Characteristics of Electromagnetic Penetration through a Slot in a Conducting Screen by a Loaded Plate (도체판을 부가한 무한 도체 평판 슬롯의 침투 전자파 저감 특성)

  • Cho, Byung-Ho;Jung, Sung-Woo;Kim, Ki-Chai
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.9
    • /
    • pp.1094-1099
    • /
    • 2012
  • This paper presents the reduction characteristics of electromagnetic penetration through a slot in conducting screen by loaded plate. The FDTD method is used in theoretical analysis. And the characteristics of penetrated electric fields are calculated in terms of length, width, position, and height of the loaded plate to find out how the geometry of plate influences the reduction characteristics of the electromagnetic penetration. The results show that the characteristics of penetrated electric field depend on the geometry of loaded plate. In particular, the optimal geometry of loaded plate which minimize penetrated electric field are verified.

Parametric resonance of axisymmetric sandwich annular plate with ER core layer and constraining layer

  • Yeh, Jia-Yi
    • Smart Structures and Systems
    • /
    • v.8 no.5
    • /
    • pp.487-499
    • /
    • 2011
  • The parametric resonance problems of axisymmetric sandwich annular plate with an electrorheological (ER) fluid core and constraining layer are investigated. The annular plate is covered an electrorheological fluid core layer and a constraining layer to improve the stability of the system. The discrete layer annular finite element and the harmonic balance method are adopted to calculate the boundary of instability regions for the sandwich annular plate system. Besides, the rheological property of an electrorheological material, such as viscosity, plasticity, and elasticity can be changed when applying an electric field. When the electric field is applied on the sandwich structure, the damping of the sandwich system is more effective. Thus, variations of the instability regions for the sandwich annular plate with different applying electric fields, thickness of ER layer, and some designed parameters are presented and discussed in this study. The ER fluid core is found to have a significant effect on the location of the boundaries of the instability regions.

A Numerical Study on the Collection Characteristics of a Wide Plate-Spacing Electrostatic Precipitator (광폭 전기집진기의 집진 특성에 관한 수치적 연구)

  • 김용진;홍원석;정상현;하병길;하대홍;유주식
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.12
    • /
    • pp.1205-1213
    • /
    • 2001
  • The electrical characteristics and particle collection efficiency of a wide-plate spacing electrostatic precipitator are numerically investigated, and the results are compared with those obtained experimentally. The electric potential and field strength near the collection plate increase with increasing the plate spacing. The electric field strength of a discharge electrode of a twisted pin type is larger than that of a rectangular type. As the roughness factor of the discharge electrode wire becomes small, or the plate spacing becomes narrow, the corona current of the precipitator increases. The numerical results agree well with those obtained from experimental method.

  • PDF

Transient thermo-piezo-elastic responses of a functionally graded piezoelectric plate under thermal shock

  • Xiong, Qi-lin;Tian, Xin
    • Steel and Composite Structures
    • /
    • v.25 no.2
    • /
    • pp.187-196
    • /
    • 2017
  • In this work, transient thermo-piezo-elastic responses of an infinite functionally graded piezoelectric (FGPE) plate whose upper surface suffers time-dependent thermal shock are investigated in the context of different thermo-piezo-elastic theories. The thermal and mechanical properties of functionally graded piezoelectric plate under consideration are expressed as power functions of plate thickness variable. The solution of problem is obtained by solving the corresponding finite element governing equations in time domain directly. Transient thermo-piezo-elastic responses of the FGPE plate, including temperature, stress, displacement, electric intensity and electric potential are presented graphically and analyzed carefully to show multi-field coupling behaviors between them. In addition, the effects of functionally graded parameters on transient thermo-piezo-elastic responses are also investigated to provide a theoretical basis for the application of the FGPE materials.

A Study on Mass Flow Control and FEA of Plate Spring Attached in Piezoelectric Ceramic (세라믹 압전체에 부착된 판 스프링의 유한요소해석과 질량 흐름 제어에 관한 연구)

  • Lee, S.K.;Kim, Y.S.
    • Journal of Power System Engineering
    • /
    • v.7 no.4
    • /
    • pp.61-66
    • /
    • 2003
  • In this paper, the relation between displacement of piezoelectric material and electric field was proposed. FEA was introduced to predict the displacement and reaction force of plate spring attached in the piezoelectric material. The relation between displacement of piezoelectric material forced by plate spring and applied electric field were further verified by experimental investigation. Also, the flow rate of gas in piezoelectric valve was examined by experiment. Finally, the relation between electric field and gas flow was derived. Based on these results, these relations can be used in the design of mass flow controller.

  • PDF