• Title/Summary/Keyword: Field of View(FOV)

Search Result 215, Processing Time 0.027 seconds

Inspection System for The Metal Mask (Metal Mask 검사시스템)

  • 최경진;이용현;박종국
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.40 no.2
    • /
    • pp.1-9
    • /
    • 2003
  • We develop an experimental system to inspect a metal mask and, in this paper, introduce its inspection algorithm. This system is composed of an ASC(Area Scan Camera) and a belt type xy-table. The whole area of the metal mask is divided into several inspection blocks. The area of each block is equal to FOV(Field of View). For each block, the camera image is compared to the reference image. The reference image is made by gerber file. The rotation angle of the metal mask is calculated through the linear equation that is substituted two end points of horizontal boundary of a specific hole in a camera image. To calculate the position error caused by the belt type xy-table, HT(Hough-Transform) using distances among the holes in two images is used. The center of the reference image is moved as much as the calculated Position error to be coincided with the camera image. The information of holes in each image, such as centroid, size, width and height, are calculated through labeling. Whether a holes is mado correctly by laser machine or not, is judged by comparing the centroid and the size of hole in each image. Finally, we build the experimental system and apply this algorithm.

Moving Object Tracking Using MHI and M-bin Histogram (MHI와 M-bin Histogram을 이용한 이동물체 추적)

  • Oh, Youn-Seok;Lee, Soon-Tak;Baek, Joong-Hwan
    • Journal of Advanced Navigation Technology
    • /
    • v.9 no.1
    • /
    • pp.48-55
    • /
    • 2005
  • In this paper, we propose an efficient moving object tracking technique for multi-camera surveillance system. Color CCD cameras used in this system are network cameras with their own IP addresses. Input image is transmitted to the media server through wireless connection among server, bridge, and Access Point (AP). The tracking system sends the received images through the network to the tracking module, and it tracks moving objects in real-time using color matching method. We compose two sets of cameras, and when the object is out of field of view (FOV), we accomplish hand-over to be able to continue tracking the object. When hand-over is performed, we use MHI(Motion History Information) based on color information and M-bin histogram for an exact tracking. By utilizing MHI, we can calculate direction and velocity of the object, and those information helps to predict next location of the object. Therefore, we obtain a better result in speed and stability than using template matching based on only M-bin histogram, and we verified this result by an experiment.

  • PDF

Development of Birdcage RF coil for 3T Animal MR Imaging

  • 추명자;최보영;강세권;최치봉;이형구;서태석
    • Progress in Medical Physics
    • /
    • v.13 no.2
    • /
    • pp.85-89
    • /
    • 2002
  • We authors developed a new small-size birdcage RF coil for animal MR images. And we compared signal-to-noise ratio (SNR) of the new small coil with a conventional knee coil. The dimension of the low-pass type birdcage coil with 12 elements at 37 MRI system are 13 cm outer diameter, 12 cm inner diameter and 20 cm length. For each element, the width of copper tape is 0.05 mm, thickness is 8 mm and length is 20 cm. The small birdcage coil with 12 elements exhibited 7 resonance modes. The isolation of the quadrature channel could be achieved more than 20 ㏈. The coil quality factor (Q value) was 98.6. The SNR of the animal coil was 243.2 on the average and was about twice as high as the conventional knee coil. The present study successfully demonstrated that the small birdcage coil could provide high quality animal MR images with the improved SNR. Therefore, it is expected that the small birdcage coil could be used in the clinical diagnosis and research studies for veterinary medicine in the near future.

  • PDF

Design and Characteristic Measurement of 8000 mm Large Aperture Integrating Sphere

  • Zhang, Zhao;Wan, Zhi;Li, Xiansheng;Liu, Hongxing;Sun, Jingxu;Liu, Zexun;Wang, Yamin;Ren, Jianwei;Ren, Jianyue
    • Journal of the Optical Society of Korea
    • /
    • v.20 no.4
    • /
    • pp.500-509
    • /
    • 2016
  • Integrating spheres play a central role in the radiometric calibration of remote sensors. With the development of the wide field of view (FOV) remote sensors, aperture diameters of remote sensors are becoming larger and larger. To satisfy the radiometric calibration requirements of full FOV and full aperture, an 8000mm diameter large aperture integrating sphere uniform source with a variable exit port was designed and manufactured. This integrating sphere will be used for pre-launch test and radiometric calibration of remote satellites. In this paper, optical theories were used to design the output spectral radiance. The LightTools software based on ray-tracing simulation method was used to determine the best combination and distribution of inner light sources. A spectral experiment was made to verify the spectral radiance design. To reduce the influence of longtime power-on, a new characteristic measurement method was developed to obtain the radiation characteristic of the integrating sphere, which could greatly improve the measuring efficiency. This method could also be applied to measure other large aperture uniform sources. The obtained results indicate that the spatial uniformity is 98.35%, and the angular uniformity at center position is 98.78%.

Cone-beam computed tomography artifacts in the presence of dental implants and associated factors: An integrative review

  • Terrabuio, Bianca Rodrigues;Carvalho, Caroline Gomes;Peralta-Mamani, Mariela;da Silva Santos, Paulo Sergio;Rubira-Bullen, Izabel Regina Fischer;Rubira, Cassia Maria Fischer
    • Imaging Science in Dentistry
    • /
    • v.51 no.2
    • /
    • pp.93-106
    • /
    • 2021
  • Purpose: This study was conducted to review the literature regarding the types of cone-beam computed tomography (CBCT) artifacts around dental implants and the factors that influence their formation. Materials and Methods: A search strategy was carried out in the PubMed, Embase, and Scopus databases to identify published between 2010 and 2020, and 9 studies were selected. The implants included 306 titanium, titanium-zirconium, and zirconia implants, as well as 5 titanium cylinders. Results: The artifacts around the implants were the beam-hardening artifact, the streaking artifact, and band-like radiolucent areas. Some factors that influenced the formation of artifacts were the implant material, bone type, evaluated regions, distance, type of CBCT, field of view (FOV) size, milliamperage, peak kilovoltage (kVp), and voxel size. The beam-hardening artifact was the most widely reported, and it was minimized in protocols with a smaller FOV, larger voxels, and higher kVp. Conclusion: The risk and benefit of these protocols in individuals with dental implants must be considered, and clinical examinations and complementary radiographs play an essential role in implantology.

V-t Characteristics and 50% Flash-over Voltage of $SF_{6}-N_{2}$ Mixtures for Lightening Impulse Voltage ($SF_{6}-N_{2}$ 혼합가스에서 뇌충격전압에 의한 50[50%] Flash over 전압 및 V-t 특성)

  • 김정달;송원표;김동의
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.7 no.1
    • /
    • pp.21-29
    • /
    • 1993
  • In this paper, we studied the 50% flashover voltage of lightening impulse which affect the most serious damages on the insulation of the electric power network system. Also its V -t characteristics and corona process phenomena of pure $SF_6, N_2, SF_6-N_2$mixtures under the circumstances of nonuniform field gap are researched. Comparing the characteristics of pure $SF_6$ with that of $SF_6, N_2$mixtures, we discussed that breakdown processes and $SF_6, N_2$ mixture's application to economics.As a results, 50% flashover voltage of $SF_6$ 50% - $N_2$ 50% for impulse voltage is higher then that of 80% of pure SF6, measured data and calculated data by equal area law are almost equal from the points of view of V-t characteristics. Therefore, it has been known that $SF_6$ 50% - $N_2$ 50% mixtures can be used as an economic constitution gas of pure $SF_6$, it is verified that corona processes from Lichtenberg figure.

  • PDF

Precise System Models using Crystal Penetration Error Compensation for Iterative Image Reconstruction of Preclinical Quad-Head PET

  • Lee, Sooyoung;Bae, Seungbin;Lee, Hakjae;Kim, Kwangdon;Lee, Kisung;Kim, Kyeong-Min;Bae, Jaekeon
    • Journal of the Korean Physical Society
    • /
    • v.73 no.11
    • /
    • pp.1764-1773
    • /
    • 2018
  • A-PET is a quad-head PET scanner developed for use in small-animal imaging. The dimensions of its volumetric field of view (FOV) are $46.1{\times}46.1{\times}46.1mm^3$ and the gap between the detector modules has been minimized in order to provide a highly sensitive system. However, such a small FOV together with the quad-head geometry causes image quality degradation. The main factor related to image degradation for the quad-head PET is the mispositioning of events caused by the penetration effect in the detector. In this paper, we propose a precise method for modelling the system at the high spatial resolution of the A-PET using a LOR (line of response) based ML-EM (maximum likelihood expectation maximization) that allows for penetration effects. The proposed system model provides the detection probability of every possible ray-path via crystal sampling methods. For the ray-path sampling, the sub-LORs are defined by connecting the sampling points of the crystal pair. We incorporate the detection probability of each sub-LOR into the model by calculating the penetration effect. For comparison, we used a standard LOR-based model and a Monte Carlo-based modeling approach, and evaluated the reconstructed images using both the National Electrical Manufacturers Association NU 4-2008 standards and the Geant4 Application for Tomographic Emission simulation toolkit (GATE). An average full width at half maximum (FWHM) at different locations of 1.77 mm and 1.79 mm are obtained using the proposed system model and standard LOR system model, which does not include penetration effects, respectively. The standard deviation of the uniform region in the NEMA image quality phantom is 2.14% for the proposed method and 14.3% for the LOR system model, indicating that the proposed model out-performs the standard LOR-based model.

Star Detectability Analysis of Daytime Star Sensor (주간 활용 별센서의 별 감지가능성 분석)

  • Nah, Ja-Kyoung;Yi, Yu;Kim, Yong-Ha
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.33 no.9
    • /
    • pp.89-96
    • /
    • 2005
  • This paper discusses the daytime atmospheric conditions and the possibility of daytime star detection with the purpose of practical use of the star sensor for daylight navigation. In order to estimate the daytime atmospheric data, we use the standard atmospheric model (LOWTRAN 7), from which atmospheric transmittance and radiance from background sky are calculated. Assuming the star sensor with an optical filter to reduce background radiation, different separation angles between the star sensor and the sun are set up to express the effect of the solar radiation. As considerations of field of view (FOV) of the star sensor, the variation of the sky background radiation and the star density of the detectable star are analyzed. In addition, the integration time to achieve a required signal-to-noise ratio and the number of the radiation-caused electrons of the charge coupled detector(CCD) working as the limit to daylight application of the star sensor are calculated.

Uses of cone-beam computed tomography in San José, Costa Rica

  • Barba, Lucia;Berrocal, Ana Luisa;Hidalgo, Alejandro
    • Imaging Science in Dentistry
    • /
    • v.48 no.2
    • /
    • pp.103-109
    • /
    • 2018
  • Purpose: To analyze cone-beam computed tomography (CBCT) use, indications, and exposure parameters in San $Jos{\acute{e}}$, Costa Rica. Materials and Methods: A cross-sectional study was performed. All CBCT examinations over a period of 6 months at 2 radiological centers in San $Jos{\acute{e}}$, Costa Rica were evaluated. The examinations were performed with Veraview EPOC X550 and Veraviewepocs 3D R100 equipment. The patients' age and sex, clinical indication for CBCT, region of interest (ROI), repeat examinations, specialty of the referring dentist, field-of-view (FOV), tube voltage (kV), tube current (mA), and radiation dose (${\mu}Gy$) were evaluated. Patients were classified by age as children (${\leq}12years$), adolescents(13-18 years), and adults(${\geq}19years$). Results: The mean age of the 526 patients was 49.4 years. The main indications were implant dentistry and dental trauma. The most frequent ROIs were posterior, while anterior ROIs were much less common. The highest percentage of repeat examinations was in children. Fifty-six percent of the referring dentists were specialists. The most commonly used FOV was small. The mean tube voltage and current were 79.8 kV and 7.4 mA for Veraview EPOC X550 and 89.9 kV and 6 mA for Veraviewepocs 3D R100, respectively. The mean doses for children, adolescents, and adults were $6.9{\mu}Gy$, $8.4{\mu}Gy$, and $7.8{\mu}Gy$, respectively. Conclusion: Although CBCT was most commonly used in adults for implant dentistry, most repeat examinations were in children, and the highest mean dose was in adolescents. Additional dose optimization efforts should be made by introducing low-dose protocols for children and adolescents.

Mid-course Trajectory Optimization for Boost-Glide Missiles Based on Convex Programming (컨벡스 프로그래밍을 이용한 추진-활공 유도탄의 중기궤적 최적화)

  • Kwon, Hyuck-Hoon;Hong, Seong-Min;Kim, Gyeong-Hun;Kim, Yoon-Hwan
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.49 no.1
    • /
    • pp.21-30
    • /
    • 2021
  • Mid-course trajectory of the missiles equipped with seeker should be designed to detect target within FOV of seeker and to maximize the maneuverability at the point of transition to terminal guidance phase. Because the trajectory optimization problems are generally hard to obtain the analytic solutions due to its own nonlinearity with several constraints, the various numerical methods have been presented so far. In this paper, mid-course trajectory optimization problem for boost-glide missiles is calculated by using SOCP (Second-Order Cone Programming) which is one of convex optimization methods. At first, control variable augmentation scheme with a control constraint is suggested to reduce state variables of missile dynamics. And it is reformulated using a normalized time approach to cope with a free final time problem and boost time problem. Then, partial linearization and lossless convexification are used to convexify dynamic equation and control constraint, respectively. Finally, the results of the proposed method are compared with those of state-of-the-art nonlinear optimization method for verification.