• 제목/요약/키워드: Field installation test

검색결과 275건 처리시간 0.044초

배전용 STATCON 설치 사례-설치 및 평가 (Field Demonstration of the Distribution STATCON-Installation & Evaluation)

  • 차재덕;김준모;홍순욱;이학성;이기선;오관일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 F
    • /
    • pp.2641-2643
    • /
    • 1999
  • This paper describes the first field demonstration of the distribution STATCON in Korea including installation and its evaluation for improving power quality in distribution system. The purpose of installation is to verify functionally the voltage source inverter based equipment for voltage regulation and harmonic mitigation in distribution line. The operational data resulting from field test and the site figure are included.

  • PDF

확장판 선단부착 PHC말뚝 및 볼트 수직이음을 사용한 PHC말뚝의 시공 중 건전성 확인을 위한 동재하시험의 적용성 및 변형시공법 PHC말뚝들의 올바른 검증시험에 관한 연구 (Study on the Applicability of Dynamic Pile Load Test to Check Integrity during Installation of Extension Plate Attached PHC Piles and Bolts Spliced PHC Piles and the Correct Proof Test of the Transformed-installation PHC Piles)

  • 김명학;최용규
    • 한국지반공학회논문집
    • /
    • 제34권12호
    • /
    • pp.115-131
    • /
    • 2018
  • 현장 시험 부지에서 확장판 선단부착 PHC말뚝 및 볼트 수직이음 PHC말뚝에 대한 시험시공을 실시하고 시공중 건전성을 동재하시험으로 확인하고 시공 후 말뚝의 건전성을 직접 확인하였다. 그 결과를 분석하여 확장판 선단부착 PHC말뚝 및 볼트 수직이음 PHC말뚝의 시공 중 건전성을 동재하시험의 건전도지수(${\beta}$지수)로 평가할 수 있는지에 대하여 연구하였다. 이론적으로 말뚝 선단에 매우 인접하거나 선단끝단에서 발생하는 손상(특히 확장판 선단부착구 자체의 변형)은 시험기술의 특성상 건전도지수로 정확한 평가하는 데에는 한계가 있었다. 말뚝의 선단부에 바로 인접해서 발생하거나 말뚝선단 끝단에서의 손상을 PDA시험을 통하여 명확하게 평가하는 데에는 시험기술의 이론에 대한 고도의 지식과 경험이 요구되었다. 다른 볼트 수직이음구로 인하여 실질적인 1차원 파동전달이 용접이음에서와 다를 수 있다는 점, 타격에 의해 발생하는 응력파의 파장이 볼트 수직이음구 높이(약 100mm)보다 클 수 있다는 점, PDA 분석 기능 중 베타 프로세싱(Beta processing)이라는 기능 등이 매우 심도 있는 지식과 경험을 토대로 평가해야만 더욱 정밀한 판단이 이루어질 수 있다는 점 등을 종합적으로 고려할 때 일반적인 건전성 평가기술로 볼트 수직이음의 건전성을 평가하는 데에는 한계가 있었다.

관로 이격거리에 따른 지중매설관의 거동특성 비교 (Comparison of Behaviors for Underground Flexible Pipes with Installation Gap)

  • 이대수;상현규;김경열;홍성연
    • 한국지반공학회논문집
    • /
    • 제19권5호
    • /
    • pp.79-87
    • /
    • 2003
  • 현행 지중전력선관로 건설시에 사용되는 표준공법은 관과 관사이의 거리를 l0cm 이격시켜 관로를 매설함에 따라 공정이 복잡하고, 경제적이지 못해 이에 대한 개선공법으로 관사이의 좌우이격거리를 없앤 접촉관 공법을 제안하였으며, 이 두 공법의 거동특성과 안정성을 비교$.$평가하고 지중매설관의 변형에 영향을 미치는 주요인자를 분석하기 위해 실규모 현장 실증실험을 수행하였다. 실험에 적용된 매설형태는 A-1급 도로포장아래 매설깊이 80cm, 100cm, 120cm 지점에 PE파형관이 각 공법형태에 맞게 매설되고, 외부하중으로 DB-24차량의 후륜하중 9.6ton이 매설관 상단 중앙에 정차했을 때 관이 받는 작용압력-변형률 특성을 분석하였다. 실험 결과, 지중매설관의 변형은 주로 시공과정중에 발생하는 것으로 나타났고, 특히, 모래되메움 공정 및 쇄석 포설 완료후에 변형이 가장 크게 발생하는 것으로 계측되었다. 그리고, 접촉관과 이격관 공법의 변형을 비교해 보면, 이격된 부분에 채워진 되메움재의 수동토압에 의한 저항압에 의존한 이격관 공법이 관과 관이 직접 접촉하여 관의 강성이 저항압으로 작용하는 접촉관 공법에 비해 변형이 작게 발생하는 것으로 분석되었다. 더불어 KS-C8455의 허용변형률 3.5%에 매설깊이 80cm, 100cm, 120cm에 묻힌 매설관이 공법 및 다짐방법에 관계없이 만족하는 변형률값을 보이고 있어 안전성을 확보하는 것으로 분석되었다.

2[MVA] 배전용 몰드변압기의 과도전계해석에 관한 연구 (A Study on the Transient Analysis of 2[MVA] Mold Transformer for Electric Field)

  • 전문호;김창업
    • 조명전기설비학회논문지
    • /
    • 제24권12호
    • /
    • pp.171-176
    • /
    • 2010
  • This paper presents the electric field for 22.9[kV]/380[V], 2[MVA] mold transformer are analysed using FEM(finite element method). The electric field was calculated for the voltage applied to the transformer. Then, it is analysed that the maximum electric field occurred between high voltage turns. Capacitance is calculated with energy method. Surge impulse test simulation is studied by modeling circuit with capacitance and inductance. This paper obtain the result that is about influence of electric field in distribution mold transformer adopted.

신장형 띠형 보강재의 형상에 따른 인발저항 및 시공성능 평가 실험 연구 (The Evaluation of Pullout Resistance and Installation Damage according to the Shape of Flexible Strip Reinforcement)

  • 정재형;김재홍
    • 지질공학
    • /
    • 제31권3호
    • /
    • pp.321-332
    • /
    • 2021
  • 최근 새로운 개념의 보강토 옹벽이 많이 개발되고 있으나, 개발된 보강재에서 발생되는 시공과정에서 문제나 붕괴와 같은 문제의 연구는 부족한 실정이다. 이에 본 연구에서는 신장형 띠형 보강재의 형상에 따른 현장 적용성을 인발저항시험과 내시공성시험으로 평가하고자 하였다. 시험체는 일반적인 신장형 띠형 보강재, 돌기가 부착된 개발된 신장형 띠형 보강재, 지오그리드를 절단하여 만든 띠형 보강재를 사용하여, 신장형 띠형 보강재 형상의 차이에 대한 기초적인 연구를 수행하고 각 보강재료의 장단점을 비교하였다. 연구 결과로서 보강재의 형상에 따른 장·단점을 명확하게 가지고 있는 것으로 나타났으며, 보강토 옹벽의 설치 조건과 뒤채움재의 입도를 고려하여 선택한다면 최선의 보강재를 선택할 수 있을 것으로 나타났다.

Evaluation of Field Calibration Test on Rail for Train Wheel Force Measurement

  • Sim, Hyoung-Bo;Yeo, Inho
    • International Journal of Railway
    • /
    • 제8권1호
    • /
    • pp.1-4
    • /
    • 2015
  • An accurate measurement of the train-track interaction forces is important for track performance evaluation. In the field calibration test as a wheel load measurement process, the calibration system creates a different boundary condition in comparison with that in the train wheel passage. This study aims to evaluate a reliability of the field calibration test in the process of wheel load measurement. Finite element models were developed to compare the deformed shapes, bending moment and shear force profiles on the rail section. The analysis results revealed that the deformed shapes and their associated bending moment profiles on the rail are significantly different in two numerical simulations of the calibration test and the train wheel load passage. However, the shear stress profile on the rail section of the strain gauge installation in the field was almost identical, which may imply that the current calibration test is sufficiently reliable.

성능검증을 위한 마이크로파일 현장 시험시공 및 재하시험 (Verification Studies for Field Peformance of Micropiling)

  • 구정민;이기환;조영준;최창호
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2009년도 춘계 학술발표회
    • /
    • pp.368-375
    • /
    • 2009
  • This paper describes field installation and load test results performed for three types of micropiles in the process of developing a new micropiling method. Field tests were performed for two conventional types(i.e., micropile reinforced with steel bar and gravity grouting, micropile reinforced with steel bar and steel casing and gravity grouting) and a proposed type(i.e., micropile reinforced with hollow steel pipe wrapped with geotextile-pack and pressurized grouting). The load test results subjected to axial compression and tension and lateral loading conditions are described in this paper. The micropiles were exposed in the air in order to verify the installation quality and curing condition of grouting material via ground excavation. Axial compression and tension test results indicate that the new micropile type provide at least 40% higher bearing capacity than that of conventional types. Based on the examination of exposed piles, it is induced that the proposed method, packed micropile, provides better interlocking between grouts and surrounding soils and increases higher frictional resistance comparing to conventional types.

  • PDF

전력산업용 PV System의 각 용량별 설계 파라미터 도출에 관한 연구 (Study on the Elicitation of Parameter in Designing each Capacity of PV System for Power Industry)

  • 김병만;이길송;양연원;신현우;김의환
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 춘계학술대회 초록집
    • /
    • pp.78.1-78.1
    • /
    • 2010
  • Recently, as much supplied with new-renewable energy, as much invested in PV system. PV system consists of PV module, PCS and Monitering system, and also could be classified into the type and the capacity by installation method and cost etc. When various systems are installed in the field, it is needed to research for applying in the field and establish infrastructure in order to ensure stable efficiency and reliability. In this study, as the basic design of the demonstration test facility, it is designed the basic PV systems for each capacity to test each PCS. In addition, It is drew the climatic conditions such as insolation, temperature and the design parameters such as installation angle, shades for the local demonstration project and expected the generation of each PV system.

  • PDF

중소형 건물 태양광발전시스템의 실증 연구 (Field Test Study of Photovoltaic Generation System for Medium and Small-Sized Buildings)

  • 김응상;김슬기
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2006년도 추계학술대회
    • /
    • pp.561-565
    • /
    • 2006
  • The paper presents a method of assessing the adequate tapaclty of photovoltaic generation systems for public buildings based on analysis of load variation patterns of customers. When PV systems are installed for supplying power for the customer load, reverse power relay is required by the guideline to be installed at the point of common coupling with the power network. The suggested method analyzes daily, weekly and monthly load demand of the customer that Irishes PV system installation, and determines the appropriate rating of the PV system for preventing PV generation from exceeding the customer demand. This work is expected to support renewable energy dissemination projects of public organizations.

  • PDF

배전급 저압피뢰기 임펄스 특성 연구 (The Study on the Impulse Characteristic of Secondary Arresters in Power Distribution System)

  • 강문호;박상만;박영근;장상옥;이흥호
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2004년도 춘계학술대회 논문집
    • /
    • pp.295-297
    • /
    • 2004
  • The overvoltage generated by the lightning strokes has been doing considerable damage to the distribution network as well as the consumer facility until now. Because most of the lightning strokes are accompanied by a storm, the aftermath of damage to the consumer is so serious. Therefore it is very important to survey the optimal operation plan by the field test of distribution lightning facilities. In this paper we have accomplished the field test to verify the impulse characteristic of Secondary Arrester(SA), and analyzed the effect of the SA in power distribution system.

  • PDF