• Title/Summary/Keyword: Field homogeneity

Search Result 196, Processing Time 0.025 seconds

A Study on Proficiency Test Sample Development for Environmental & Reliability Testing Field (환경 및 신뢰성 시험분야를 위한 숙련도시험 시료개발 연구)

  • PARK, Kyunghwan;LEE, Cheolgyu
    • Journal of Korean Society for Quality Management
    • /
    • v.45 no.3
    • /
    • pp.447-462
    • /
    • 2017
  • Purpose: This study aims to develop distributable samples that can be used for proficiency testing to verify the ability of the testing laboratory to perform high temperature and low temperature tests. Method: In this study, the temperature-resistance characteristics of the NTC thermistor were used to develop samples. The homogeneity and stability of samples were examined according to the proficiency testing requirements. Results: Thirty samples with homogeneity and stability were developed and used for the proficiency testing. Thus, it was possible to distinguish between the test laboratories that showed satisfactory results and those that did not. Conclusion: It was the first time to develop samples that can be used for proficiency testing in high temperature and low temperature tests. and it was proved that the proficiency test program can be operated using the characteristics of NTC thermistor.

The Study on the Superconducting MRI Magnet of 68 cm in Room Temperature Bore (68 cm 상온 보아를 갖는 MRI용 초전도마그네트에 관한 연구)

  • Jin, H.B.;Oh, B.H.;Cho, J.W.;Oh, S.S.;Kwon, Y.K.;Ha, D.W.;Lee, E.Y.;Kim, H.J.;Kim, O.K.;Choi, B.J.;Ryu, K.S.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.11
    • /
    • pp.142-146
    • /
    • 1996
  • In this paper, we present the main research results on the 2 Tesla class - superconducting MRI magnet which we have developed. Multi section type superconducting MRI main coil and various superconducting shims were designed and fabricated for obtaining the high field homogeneity, which is requested in the MR imaging. After assembling the magnet with room temperature bore cryostat field homogenity has been measured and analyzed by NMR field mapping system. According to this, field homogeneity of 22 ppm / 30 cm dsv was confirmed.

  • PDF

Evaluation of Soil Compaction Using Gravity Field Interpretation and UAV-based Remote Sensing Information (중력 데이터 해석과 드론원격정보를 이용한 지반의 다짐도 평가)

  • Kim, Sung-Wook;Choi, Sungchan;Choi, Eun-Kyoung;Lee, Yeong-Jae;Go, Daehong;Lee, Kyu-Hwan
    • The Journal of Engineering Geology
    • /
    • v.31 no.3
    • /
    • pp.283-293
    • /
    • 2021
  • The homogeneity of the compacted ground was analyzed using drone-based remote terrain and gravity field data. Among the topographic elements calculated by the hydrological algorithm, the topographic curvature effectively showed the shape of the surface that occurred during the compaction process, and the non-uniformly compacted area could be identified. The appropriate resolution of the digital topography requires a precision of about 10 cm. Gravity field Interpretation was performed to analyze the spatial density change of the compacted ground. In the distribution of residual bouguer gravity anomaly, the non-homogeneously compacted area showed a different magnitude of gravity than the surrounding area, and the difference in compaction was identified through gravity-density modeling. From the results, it is expected that the topographic element and gravitational field analysis method can be used to evaluate the homogeneity of the compacted ground.

The Domestic Development of a Superconducting MRI Magnet (초전도 MRI 마그네트 국산화 개발)

  • 배준한;심기덕;고락길;진홍범;조전욱;하동우;오상수;권영길;류강식
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2001.02a
    • /
    • pp.121-124
    • /
    • 2001
  • The research results on the superconducting magnet for whole body MRI are presented. The magnet consists of main coil with 6 solenoid coils, shielding coil with 2 solenoid coils and 6 sets of cryogenic shim coil. The ferromagnetic shim assembly is installed on the inside wall of the room temperature bore for shimming inhomogeneous field components generated due to manufacturing tolerances, installation misalignments and external ferromagnetic materials near the magnet. Also, the magnet is enclosed with the horizontal type cryostat with 80cm room temperature bore to keep the magnet under the operating temperature. The magnetic field distributions within the imaging volume were measured by the NMR field mapping system. Through the test, the central field of magnet was 1.5 Tesla and the field homogeneity of 9.3 ppm has been obtained on 40cm DSV(the diameter of spherical volume) and using this magnet, comparatively good images for human body, fruits and water phantoms have been achieved.

  • PDF

A Study on Highly Homogeneous Double Helmholtz Superconducting Magnet and Newly Configurated Superconducting Magnet (고균일자계 Double Helmholtz형 및 삼개분리 원통형키전동자석에 관한 연구)

  • 이승원;권용안
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.37 no.8
    • /
    • pp.521-527
    • /
    • 1988
  • At present superconducting magnets have been feasible for many applications which require high field or highly homogeneous field that it is too difficult to be produced by conventional electromagnets. This paper is a stuny on Donble Helmholtz superconducting magnet and newly configurated superconducting magnet that realize highly homogeneous field with the minimum magnet volume. Nonlinear programming method is effectively used for the minimum volume of superconducting magnet that realizes the desired field intensity and high homogeneity. The results on Double Helmholtz and newly configurated superducting magnets that are presented in this paper are largely improved.

  • PDF

Design of Body RF Coil with Multiple Strips for Open MRI System by Pseudo Electric Dipole Radiation

  • 김경락;류승학;류연철;양형진;오창현
    • Proceedings of the KSMRM Conference
    • /
    • 2002.11a
    • /
    • pp.76-76
    • /
    • 2002
  • Purpose: The purpose of this study is to optimize the configuration of body RF coil composed of 4 planar subcoils for low field open MRI. Method: Our low field RE coil is composed of 4 subcoils assumed to be located at both the bottom and top sides of permanent magnet. Each subcoils has 3 main strips. The coil system has mirror inversion symmetry. First, the currents on the strips are obtained by inductance calculation and circuit analysis, Second, all the strips are divided into line strip elements across the strips, the self Inductances of line strip elements and the mutual inductances among the line strip elements are calculated, and current distributions of strip are obtained by circuit analysis, where each strip is considered as parallel combination of line strip elements. Finally all the line strip elements are segmented, magnetic field has been calculated by pseudo electric dipole radiation method, where the current elements are regarded as pseudo electric dipole radiation sources. We have performed above procedures for various configurations of RE coil. The field homogeneity is calculated in the 25 cm DSV.

  • PDF

Design and Implementation of Portable NMR Probe Magnet

  • Junxia, Gao;Yiming, Zhang;Jiashen, Tian
    • Journal of Magnetics
    • /
    • v.22 no.1
    • /
    • pp.14-22
    • /
    • 2017
  • The NMR's probe consists of the static magnetic field generator (magnetic source) and the RF coil. It is very strict for the homogeneity of the static magnetic field intensity of the magnetic source, so the cost of the magnetic source is more expensive in the entire nuclear magnetic resonance instrument. The magnetic source generally consists of electromagnet, permanent magnet and superconducting magnet. The permanent magnet basically needs not to spend on operation and maintenance and its cost of manufacture is much cheaper than the superconducting magnet. Therefore, the permanent magnet may be the only choice for the static magnetic field device if we want to use the magnetic resonance instrument as an analyzer for production by reducing price. A new probe magnet was developed on the basis of the permanent magnet ring in this paper to provide a technological way for reducing the manufacturing cost, weight and volume of the existing nuclear magnetic resonance instrument (including MRI) probe.

Design of Low Field RF Coil for Open MRI System by Electric Dipole Radiation

  • 김경락;양형진;오창현
    • Proceedings of the KSMRM Conference
    • /
    • 2001.11a
    • /
    • pp.174-174
    • /
    • 2001
  • Purpose: Dimensions of body RF coil composed of 4 rectangular loops for low field open MRI hav been optimized. The design result shows the field inhomogeneity of B1 field below 1.5 dB in the 25 cm DSV can be achieved. Method: Our low field RF coil is composed of 4 rectangular strip loops that assumed to b located at both the bottom and top sides of permanent magnet. All the loops have identica dimensions and current amplitude. First, the inductance of a loop is calculated. Second, the current distribution on the coil strip is calculated by using finite difference time doma method (FDTD). It takes as much as 4 days in FDTD simulation for low frequency RF field That's why the electrical dipole radiation method is used for simulation. With the curren distribution obtained using the FDTD simulation, for various dimensional parameters th magnetic field has been calculated by electric dipole radiation method, where the curren elements are regarded as electric dipole radiation sources. The field pattern from electri dipole radiation is almost same as that from FDTD simulation. Also, it is same as that fro the result using the Viot-Savart equation, for far tone radiation term becomes zero and th Bl field amplitude of near one radiation is the same as the B field due to static current The field homogeneity is calculated in the 25 cm BSV.

  • PDF

Field gradient calculation of HTS double-pancake coils considering the slanted turns and the splice

  • Baek, Geonwoo;Kim, Jinsub;Lee, Woo Seung;Song, Seunghyun;Lee, Onyou;Kang, Hyoungku;Ko, Tae Kuk
    • Progress in Superconductivity and Cryogenics
    • /
    • v.19 no.1
    • /
    • pp.51-55
    • /
    • 2017
  • To obtain Nuclear Magnetic Resonance (NMR) measurement of membrane protein, an NMR magnet is required to generate high intensity, homogeneity, and stability of field. A High-Temperature Superconducting (HTS) magnet is a promising alternative to a conventional Low-Temperature Superconducting (LTS) NMR magnet for high field, current density, and stability margin. Conventionally, an HTS coil has been wound by several winding techniques such as Single-Pancake (SP), Double-Pancake (DP), and layer-wound. The DP winding technique has been frequently used for a large magnet because long HTS wire is generally difficult to manufacture, and maintenance of magnet is convenient. However, magnetic field generated by the slanted turns and the splice leads to field inhomogeneity in Diameter of Spherical Volume (DSV). The field inhomogeneity degrades performance of NMR spectrometer and thus effect of the slanted turns and the splice should be analyzed. In this paper, field gradient of HTS double-pancake coils considering the slanted turns and the splice was calculated using Biot-Savart law and numerical integration. The calculation results showed that magnetic field produced by the slanted turns and the splice caused significant inhomogeneity of field.

A Study on the Liquid Encapsulant Czochralski(LEC) Crystal Growth with Magnetic Fields (자기장하에서 액막 초크랄스키 방법에 의한 단결정 성장에 관한 연구)

  • Kim, Mu-Geun;Seo, Jeong-Se
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.12
    • /
    • pp.1667-1675
    • /
    • 2001
  • Numerical simulations are carried out for the liquid encapsulant Czochralski(LEC) by imposing a magnetic field. The use of a magnetic field to the crystal growth is to suppress melt convection and to improve the homogeneity of the crystal. In the present numerical investigation, we focus on the range of 0-0.3Tesla strength for the axial and cusped magnetic field and the effect of the magnetic field on the melt-crystal interface, flow field and temperature distribution which are the major factors to determine the quality of the single crystal are of particular interest. For both axial and cusped magnetic field, increase of the magnetic field strength causes a more convex interface to the crystal. In general, the flow is weakened by the application of magnetic field so that the shape of the melt-crystal interface and the transport phenomena are affected by the change of the flow and temperature field.