• Title/Summary/Keyword: Field heat

Search Result 2,036, Processing Time 0.034 seconds

Domestic Efforts for SFCL Application and Hybrid SFCL (국내 초전도 한류기 요구와 하이브리드 초전도 한류기)

  • Hyun, O.B.;Kim, H.R.;Yim, Y.S.;Sim, J.;Park, K.B.;Oh, I.S.
    • Progress in Superconductivity
    • /
    • v.10 no.1
    • /
    • pp.60-67
    • /
    • 2008
  • We present domestic efforts for superconducting fault current limiter (SFCL) application in the Korea Electric Power Corporation (KEPCO) grid and pending points at issue. KEPCO's decision to upgrade the 154 kV/22.9 kV main transformer from 60 MVA to 100 MVA cast a problem of high fault current in the 22.9 kV distribution lines. The grid planners supported adopting an SFCL to control the fault current. This environment friendly to SFCL application must be highly dependent upon the successful development of SFCL having specifications that domestic utility required. The required conditions are (1) small size of not greater than twice of 22.9 kV gas insulated switch-gear (GIS), (2) sustainability of current limitation without the line breaking by circuit breakers (CB) for maximum 1.5 seconds. Also, optionally, recommended is (3) the reclosing capability. Conventional resistive SFCLs do not meet (1) $\sim$ (3) all together. A hybrid SFCL is an excellent solution to meet the conditions. The hybrid SFCL consists of HTS SFCL components for fault detection and line commutation, a fast switch (FS) to break the primary path, and a limiter. This characteristic structure not only enables excellent current limiting performances and the reclosing capability, but also allows drastic reduction of HTS volume and small size of the cryostat, resulting in economic feasibility and compactness of the equipment. External current limiter also enables long term limitation since it is far less sensitive to heat generation than HTS. Semi-active operation is another advantage of the hybrid structure. We will discuss more pending points at issues such as maintenance-free long term operation, small size to accommodate the in-house substation, passive and active control, back-up plans, diagnosis, and so on.

  • PDF

Defect Detection of Carbon Steel Pipe Weld Area using Infrared Thermography Camera (적외선 열화상 카메라를 이용한 탄소강관 용접부 결함검출)

  • Kwon, DaeJu;Jung, NaRa;Kim, JaeYeol
    • Tribology and Lubricants
    • /
    • v.30 no.2
    • /
    • pp.124-129
    • /
    • 2014
  • The piping system accounts for a large portion of the machinery structure of a plant, and is considered as a very important mechanical structure for plant safety. Accordingly, it is used in most energy plants in the nuclear, gas, and heavy chemical industries. In particular, the piping system for a nuclear plant is generally complicated and uses the reactor and its cooling system. The piping equipment is exposed to diverse loads such as weight, temperature, pressure, and seismic load from pipes and fluids, and is used to transfer steam, oil, and gas. In ultrasound infrared thermography, which is an active thermography technology, a 15-100 kHz ultrasound wave is applied to the subject, and the resulting heat from the defective parts is measured using a thermography camera. Because this technique can inspect a large area simultaneously and detect defects such as cracks and delamination in real time, it is used to detect defects in the new and renewable energy, car, and aerospace industries, and recently, in piping defect detection. In this study, ultrasound infrared thermography is used to detect information for the diagnosis of nuclear equipment and structures. Test specimens are prepared with piping materials for nuclear plants, and the optimally designed ultrasound horn and ultrasound vibration system is used to determine damages on nuclear plant piping and detect defects. Additionally, the detected images are used to improve the reliability of the surface and internal defect detection for nuclear piping materials, and their field applicability and reliability is verified.

The Study of poly-Si Eilm Crystallized on a Mo substrate for a thin film device Application (박막소자응용을 위한 Mo 기판 위에 고온결정화된 poly-Si 박막연구)

  • 김도영;서창기;심명석;김치형;이준신
    • Journal of the Korean Vacuum Society
    • /
    • v.12 no.2
    • /
    • pp.130-135
    • /
    • 2003
  • Polycrystalline silicon thin films have been used for low cost thin film device application. However, it was very difficult to fabricate high performance poly-Si at a temperature lower than $600^{\circ}C$ for glass substrate because the crystallization process technologies like conventional solid phase crystallization (SPC) require the number of high temperature (600-$1000^{\circ}C$) process. The objective of this paper is to grow poly-Si on flexible substrate using a rapid thermal crystallization (RTC) of amorphous silicon (a-Si) layer and make the high temperature process possible on molybdenum substrate. For the high temperature poly-Si growth, we deposited the a-Si film on the molybdenum sheet having a thickness of 150 $\mu\textrm{m}$ as flexible and low cost substrate. For crystallization, the heat treatment was performed in a RTA system. The experimental results show the grain size larger than 0.5 $\mu\textrm{m}$ and conductivity of $10^{-5}$ S/cm. The a-Si was crystallized at $1050^{\circ}C$ within 3min and improved crystal volume fraction of 92 % by RTA. We have successfully achieved a field effect mobility over 67 $\textrm{cm}^2$/Vs.

An Improvement of Fire Safety Code for Rack-Type Warehouse in Korea (국내 랙크식 창고의 방화관련 규정 개선에 관한 연구)

  • Kim, Woon-Hyung;Lee, Young-Jae
    • Fire Science and Engineering
    • /
    • v.28 no.6
    • /
    • pp.69-75
    • /
    • 2014
  • Recently Amore pacific rack-type warehouse fire broke out and argue an urgent improvement of fire protection design code including automatic sprinkler and detection design. Various type of commodities have their unique fire characteristics from fire spread rate and heat lease rate and fire hazard depends on storage height, rack arrangement, aisle width, fire load etc. With increasing ceiling height for more storage space prevent effective water spray of sprinkler head, also delays detection time causes failure of early suppression. To achieve fire protection code performance of this occupancy, Major code articles relating to a classification of commodity, sprinkler system installation, detection and fire fighting are reviewed and suggested based on fire case analysis, code review between country and field survey.

A Study on Features of Fire and Change of Extinguishing Capacity of Sprinkler Equipment Against Fire at a Traditional Market (재래시장에서의 화재조건에 따른 스프링클러설비의 소화성능변화와 화재특성에 관한 연구)

  • Park, Jin-Woo;Jeon, Gyu-Yeob;Na, Wook-Jung;Hong, Won-Hwa
    • Fire Science and Engineering
    • /
    • v.22 no.1
    • /
    • pp.128-138
    • /
    • 2008
  • Lots of products stocked at a traditional market are made of rubbers, synthetic fibers and plastics which when on fire, emit high heat to easily ignite nearby inflammables. And shops are not divided by fireproof partitions but by combustible curtains, which contributes to a possibility of a conflagration. In this study, danger and weak factors on fire at a traditional market was analyzed. Non-existence of partition between shops and the height of piled inflammables are set as danger factors and change of extinguishing capacity of sprinklers was analyzed using fire dynamics simulator. As a result, it turned out that partitions between shops and high-piled inflammables reduced watering radius of sprinklers and increased the size of fire and distribution of temperature.

A Study on the Improvement of Manual Rice Cutters (인력대취검 개량제작시험연구)

  • 이철주
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.11 no.1
    • /
    • pp.1580-1597
    • /
    • 1969
  • 1. The field test of our experiment comparing the traditional syckle and the new manually pulled cutter showed that the working efficiency of the manually pulled cutter is about two times higher than that of the syckle. The operator can standerect while using the manually pulled cutter, thus reducing fatigue. Because of the reduction in body fatigue, the operator is able to work more total hours, making the manually pulled harvester three times more efficient than the syckle. 2. The optimum angle for the V-shaped cutter blade varies according to the number of the hiller, but in manufacturing the cutter, the range must be controlled between $35^{\circ}{\sim}45^{\circ}$. 3. The radius of curvature of the V-shaped blade is closely related to the blade angle. The best results were obtained when the radii of curvature were r=32cm with $35^{\circ}$ angle, r=153mm with $45^{\circ}$ angle, and r=220mm with $40^{\circ}$ angle. 4. The hardness distribution test of the blade showed great differences between foreign made and domestic made blades. The heat treatment method must be greatly improved for superior hardness distribution. 5. Although the efficiency of the manually pushed cutter is equal to that of the manually pulled cutter, the manually pushed cutter is not only more expensive to produce but also has a much more complicated structure than the manually pulled cutter. Because of our rural economic conditions, the power harvester which is utilized in foreign countries can not yet be introduced here. Thus, the manually pulled cutter should be popularized in our rural areas until economic conditions will allow us to introduce power harvesters. 6. The use of the manually pulled cutter will make it possible for an operator to harvest an area in only one-third of the time that it would take to harvest the same area with a traditional syckle, and it will make it possible for an operator to earn about 8,000 won for harvesting 10 Jung-bo: such benefits will help in increasing farm income and will contribute to farm modernization.

  • PDF

A Comparative Study of 2-Dimensional Turbulence Models for Thermal Discharge (2차원 온배수 난류모형의 비교연구)

  • Choi, Hung-Sik
    • Journal of Korea Water Resources Association
    • /
    • v.32 no.3
    • /
    • pp.225-235
    • /
    • 1999
  • For a comparative evaluation of three turbulence models in the analyses of thermal discharge behavior into a crossflow, a 2-dimemsional near-field numerical model is developed. The selected models are k-$\varepsilon$ and k-ι turbulence models as a 2-equation turbulence model and a 4-equation turbulence model in which the transport equations for mean of the temperature fluctuation squared and its dissipation rate for the consideration of buoyancy production and turbulent heat flux terms are added to a k-$\varepsilon$ turbulence model. The developed models are applied to a steady flow in an open channel with simple geometry and the numerical results agree with the existing experimental data. Numerical results of buoyancy induced gravitational lateral spreading by 4-equation turbulence model agree with the experimental data better than those of 2-quation turbulence models. The flow patterns by 4 and 2-equation turbulence models are similar.

  • PDF

A Study on the Fire Characteristics of Palletized Unit-Load Commodities on Racks (랙크 내 파렛트단위 적재물품의 화재특성에 관한 연구)

  • Cho, Gyu-Hwan;Yeo, In-Hwan
    • Fire Science and Engineering
    • /
    • v.30 no.3
    • /
    • pp.23-30
    • /
    • 2016
  • A fire extinguishing system for a rack warehouse was recently designed, which only consider the gross area and number of stories. However, the design of such a system should take into account not only the planar structuree, but also the elevation perspectives due to its vertical structure. Moreover, the fire load of the commodities palletized on the racks should be considered, in order to design a performance-based fire safety system that is appropriate for these environmental conditions. For this reason, this study analyzed the fire characteristics of the commodities palletized on the racks (pallet + the commodities in a box unit + vinyl packing material), taking into consideration the results of a field investigation conducted in Korea, as well as the Hazard Classifications of Commodities used in other countries. Through this analysis, the heat release rate (HRR) and smoke production rate (SPR) were derived.

The Textiles and the Performance Level in Developing the Pesticide Proof Clothing (기능성 농약방제복 개발을 위한 소재 및 성능에 관한 연구)

  • Hwang, Kyoung-Sook;Kim, Kyung-Ran;Lee, Kyung-Suk;Kim, Hyo-Cher;Kim, Kyung-Su;Baek, Yoon-Jeong
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.31 no.11
    • /
    • pp.1611-1620
    • /
    • 2007
  • The precaution to spray with agricultural chemicals is very important, in particular personal protective equipment against pesticide in order to protect farmers# pesticide poisoning. The Ministry of Agriculture and Forestry has proclaimed the announcement of pesticide proof clothing(PPC) in 1983, and revised it in 1987. The announcement had many performance items to achieve the high-quality protective clothing for pesticide including weight, density, force strength, dimensional change(in washing and drying), fastness(dyeing, washing, sweating and rubbing) and water resistance of clothes. Announcement of the PPC has better durability and penetration resistance function than former days, but the plenty of farmers didn#t wear it because of the intolerable heat. To increase wearing rates, the pesticide proof clothing must be estimated the water-vapour resistance. From the results, the developed PPC with polyester treated water-repellent showed the more excellent comfort than an existing PPC with nylon coated polyurethane. But the developed PPC appeared to have the low water-vapour resistance. Therefore, it is suggested that the property of pesticide penetration must be evaluated through the field test in the future study.

Fabrication of a Micro Electromagnetic Flow Sensor for Micro Flow Rate Measurement (미소 유량 측정을 위한 마이크로 전자 유량 센서의 제작)

  • Yoon, Hyeun-Joong;Kim, Soon-Young;Yang, Sang-Sik
    • Journal of Sensor Science and Technology
    • /
    • v.9 no.5
    • /
    • pp.334-340
    • /
    • 2000
  • This paper presents the fabrication of a micro electromagnetic flow sensor for the liquid flow rate measurement. The micro electromagnetic flow sensor has some advantages such as a simple structure, no heat generation, a rapid response and no pressure loss. The principle of the micro electromagnetic flow sensor is based on Faraday's law. If conductive fluid passes through a magnetic field, the electromotive force is generated and detected by two electrodes on the wall of the flow channel. The flow sensor consists of two permanent magnets and a silicon flow channel with two electrodes. The dimension of the flow sensor is $9\;mm\;{\times}\;9\;mm\;{\times}\;1\;mm$. The micro flow channel is mainly fabricated by anisotropic etching of two silicon wafers, and the detection electrodes are fabricated by metal evaporation process. The characteristic of the fabricated flow sensor is obtained experimentally. When the flow rates of water with the conductance of $100-200\;{\mu}S/cm$ are 9.1 ml/min and 62 ml/min, the generated electromotive forces are $261\;{\mu}V$ and 7.3 mV, respectively.

  • PDF