• Title/Summary/Keyword: Field evaluation

Search Result 5,836, Processing Time 0.04 seconds

Accumulation of Selenium and Changes in the Activity of Inulinase and Catalase in the Cells of Kluyveromyces marxianus on Pulsed Electric Field Treatment

  • Pankiewicz, Urszula;Jamroz, Jerzy
    • Journal of Microbiology and Biotechnology
    • /
    • v.20 no.7
    • /
    • pp.1101-1106
    • /
    • 2010
  • Pulsed electric field (PEF) of 1Hz, 1.5 kV, and 1ms increased the activities of catalase and inulinase over the whole range of applied Se concentrations compared with the non-treated cultures. A significant effect of selenium concentration (in the range of 5-14 ${\mu}g/ml$) on both intra- and extracellular enzyme activities was noted. At a Se concentration of 10 ${\mu}g/ml$, the activities of intra- and extracellular inulinases and extracellular catalase in the PEF-treated cultures reached the maximum of 71 U/g d.m., 46 U/g d.m., and approx. 8 U/ml, respectively. The maximum activity of intracellular catalase of approx. 6 U/ml (with and without PEF) was recorded at 5 ${\mu}g$ Se/ml. Further increasing of selenium concentration caused a decrease in the activity of the enzymes.

The Effect of Pulse Electric Field on Accumulation of Selenium in Cells of Saccharomyces cerevisiae

  • Pankiewicz, Urszula;Jamroz, Jerzy
    • Journal of Microbiology and Biotechnology
    • /
    • v.17 no.7
    • /
    • pp.1139-1146
    • /
    • 2007
  • Cultures of Saccharomyces cerevisiae were subjected to the effect of PEF (pulse electric field) and a source of selenium. The culture period after which yeast cells were subjected to PEF treatment was optimized, as was the duration of the exposure. Optimization of the nutrient medium composition in S. cerevisiae cultures resulted in an over 1.8-fold increase in selenium accumulation with relation to cultures on the initial substrate. Optimization of the pH value and of culture duration resulted in selenium accumulation increase by approximately 78%. A significant correlation was found between the accumulation of selenium in yeast cells and its concentration in the culture substrate. The highest accumulation of selenium in the biomass of yeast, approx. $240\;{\mu}g/g$ d.m., was obtained after 15-min exposure to PEF on a 20-h culture. An approx. 50% higher content of selenium in cells was recorded, as compared with the control culture without the application of PEF.

Field Demonstration of the Distribution STATCON-Installation & Evaluation (배전용 STATCON 설치 사례-설치 및 평가)

  • Cha, J.D.;Kim, J.M.;Hong, S.W.;Lee, H.S.;Lee, K.S.;Oh, K.I.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07f
    • /
    • pp.2641-2643
    • /
    • 1999
  • This paper describes the first field demonstration of the distribution STATCON in Korea including installation and its evaluation for improving power quality in distribution system. The purpose of installation is to verify functionally the voltage source inverter based equipment for voltage regulation and harmonic mitigation in distribution line. The operational data resulting from field test and the site figure are included.

  • PDF

Error Evaluation on Flame Measurement in Combustion Field (연소장내 화염계측 오차 평가)

  • Yang, Young Joon;Heo, Tae Young
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.167-169
    • /
    • 2014
  • Spray combustion has been used in many industrial fields, for instance, such as diesel engines, gas turbines and industrial furnaces, and furthermore various measurement techniques have been applied to elucidate the phenomenon of spray combustion. In order to measure simultaneously the droplet velocity and the droplet size of spray, Phase Doppler Anemometry (PDA) was frequently used in spray combustion. However, the measurement error is occurred due to existence of flame, which is considered as influencing the precision of measurement. Therefore, the purpose of this study is experimentally to conduct the systematic evaluation on the measurement error when PDA measurement is applied to combustion field.

  • PDF

Field Applicability of Design Methodologies for Groundwater Quality Monitoring Network

  • Lee, Sang-Il
    • Korean Journal of Hydrosciences
    • /
    • v.10
    • /
    • pp.47-58
    • /
    • 1999
  • Protection of groundwater resources from contamination has been of increasing concern throughout the past decades. In practice, however, groundwater monitoring is performed based on the experience and intuition of experts or on the convenience. In dealing with groundwater contamination, we need to know what contaminants have the potential to threat the water quality and the distribution and concentration of the plumes. Monitoring of the subsurface environment through remote geophysical techniques or direct sampling from wells can provide such information. Once known, the plume can be properly menaged. Evaluation of existing methodologies for groundwater monitoring network design revealed that one should select an appropriate design method based on the purpose of the network and the avaliability of field information. Integer programming approach, one of the general purpose network design tools, and a cost-to-go function evaluation approach for special purpose network design were tested for field applicability. For the same contaminated aquifer, two approaches resulted in different well locations. The amount of information, however, was about the same.

  • PDF

Design and evaluation of a distributed TDR moisture sensor

  • Zhang, Bin;Yu, Xinbao;Yu, Xiong
    • Smart Structures and Systems
    • /
    • v.6 no.9
    • /
    • pp.1007-1023
    • /
    • 2010
  • This paper describes the development and evaluation of an innovative TDR distributed moisture sensor. This sensor features advantages of being responsive to the spatial variations of the soil moisture content. The geometry design of the sensor makes it rugged for field installation. Good linear calibration is obtained between the sensor measured dielectric constant and soil physical properties. Simulations by the finite element method (FEM) are conducted to assist the design of this sensor and to determine the effective sampling range. Compared with conventional types of moisture sensor, which only makes point measurement, this sensor possesses distributed moisture sensing capability. This new sensor is not only easy to install, but also measures moisture distribution with much lower cost. This new sensor holds promise to significantly improve the current field instruments. It will be a useful tool to help study the influence of a variety of moisture-related phenomena on infrastructure performance.

An Evaluation of Fire Resistance Performance for Fiber-Mixed Ultra High Strength Concrete on Field application (현장 적용성을 고려한 섬유혼입 초고강도 콘크리트의 내화성능 평가)

  • Choe, Gyeong-Choel;Kim, Gyu-Yong;Lee, Tae-Gyu;Min, Choong-Siek;Koo, Kyung-Mo;Shin, Kyoung-Su
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2011.05a
    • /
    • pp.33-36
    • /
    • 2011
  • Recently, It has increased to use ultra high strength concrete. It is effective to mix organic fibers for preventing spalling. But if fiber mixed, flowability of concrete is decreases. The aim of this study is to evaluation of fire resistance performance for fiber-mixed ultra high strength concrete on field application. As a result, flowability of nylon fiber mixed concrete is better than polyethylene fiber mixed. In non-fiber and polyethylene fiber mixed concrete, spalling occurred. And strain converged at 0.004. Also, residual strength could not evaluate. Nylon fiber mixed concrete is effective to prevent spalling. And it remians 50% residual strength compare with compressive strength at room temperature.

  • PDF

Introduction of the field - test evaluation system in KEPCO (배전 실증시험장 시스템 현황 소개)

  • Kim, Dong-Myung;Choi, Sun-Kyu;Jang, Sang-Ok;Oh, Jae-Hyoung
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.81-85
    • /
    • 2004
  • This paper describes the testing facility to demonstrate the performance of the distribution class circuit breakers and switchgears and the testing methods. The field-test evaluation system consists of two parts. One is the distribution system for simulation of the condition on interruption mode of switches which are installed in the system and tested by the AFG(Artificial Fault Generator) and the thunderbolt generator just like in the real field. The other is a laboratory for confirmation or the important characteristics regarding to the insulation, gas, environment durability of equipment. For the fatal failure mode, a FMEA(Failure Modes and Effects Analysis) technique which is a kind of a structural analysis to consider a counter-plan was emploved.

  • PDF

An Analysis of Rolling-Stock Information Maintenance System Real-Field Operational Results (전동차 유지보수 정보화체계 관리시스템 실증적 운영결과 분석)

  • Son, Young-Jin;Lee, Kang-Won
    • Journal of the Korean Society for Railway
    • /
    • v.10 no.3 s.40
    • /
    • pp.284-289
    • /
    • 2007
  • We analyze the real-field operational results of the RIMS. Four aspects are considered; 1) economical, 2) managerial, 3) safety and reliability and 4) RIMS user evaluation. In economical aspect we investigate the fields where some economical gains are anticipated. In managerial aspect the efficiency and effectiveness of management through RIMS are investigated. The improvement of safety and reliability are qualitatively discussed. And RIMS user evaluation is performed through survey. We also suggest several conditions for the successful settlement of RIMS and future study area for RIMS to be more reliable and perfect.

Study to Propose the Suitable Reproducing Sound Level of SAFRS (능동형 음장조성시스템 연출음의 적정 소리레벨 제시를 위한 기초적 연구)

  • Jeon, Ji-Hyeon;Shin, Yong-Gyu;Kook, Chan;Jang, Gil-Soo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.515-518
    • /
    • 2007
  • SAFRS(Spontaneous Acoustic Field Reproduction System) is a system to sense changes of surroundings and produce sounds which can go well with environment elements sensed by the system in to the space. The sounds were judged by individual evaluation and, the classification of the preferred sounds according to the mood of the space was suggested in the former study. Effectiveness of SAFRS with field application was validated by prior studies which dealt with researching acoustic environment, evaluating images of sounds, and rating environment with existence and nonexistence of sound resources such as fountains and the system after applied in D university. In this study, for more effective field application of SAFRS, research for the acoustic environment around sound resources and subjective evaluation of the preference of the sounds from the resources were made and it was considered that the results of the experiments should be primary information to propose proper sound level to be offered by the system. The results of the study are as follows; 1) It was considered that the ambience of the center road was dependent upon produced sounds by the system and water sounds of the fountain and that of walk way was mostly dependent upon produced sounds. 2) The results of the subjective evaluation showed that the distance from sound resources was suggestive; the more distant from produced sounds the less full and clear the sounds, the less distant from the sounds of water the more delight and idyllic ambience, and the less distant from the forest the more idyllic ambient and diversity. 3) The results upwards were telling that an average value of six elements for the evaluation was even at the place set back 10.2m from center road and walk way. And harmony of all sounds of the place should be considered to propose suitable sound level of SAFRS.

  • PDF