• Title/Summary/Keyword: Field effect

Search Result 12,296, Processing Time 0.039 seconds

Effect of an External AC Magnetic field on Dynamic Resistance and Loss Characteristic in a Bi-2223 Tape (외부 교류자장이 Bi-2223테이프의 동저항 및 손실특성에 미치는 영향)

  • Ryu, Kyung-Woo;Choi, Byoung-Ju
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.18 no.5
    • /
    • pp.473-477
    • /
    • 2005
  • A Bi-2223 tape has been developed for power applications such as a fault current limiter, a power cable and a superconducting magnetic energy storage system. In such applications, the Bi-2223 tape carries time varying transport current and in addition experiences time varying external magnetic field. It is well known that the external magnetic field not only causes magnetization loss in the Bi-2223 tape, but also drastically increases transport loss due to a so-called 'dynamic resistance' We developed an evaluation setup, which can measure transport loss in external at magnetic fields. Using this equipment, we measured the dynamic resistances for various amplitudes and frequencies of an external at magnetic field perpendicular to the face in the tape. Simultaneously we investigated the effect of an external ac field on transport loss with different experimental conditions. This paper describes test results ana discussions on correlation between the dynamic resistance and the transport loss for the Bi-2223 tape.

A Study on the Effect of the Contact Electrode Slits in the Vacuum Interrupter with Axial Magnetic Field Type (종자계형 진공 인터럽터에서 접점전극 슬릿의 영향에 관한 연구)

  • 하덕용;강형부;최승길;최경호
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.15 no.9
    • /
    • pp.822-829
    • /
    • 2002
  • This paper deals with the distribution characteristics of the current density and axial magnetic flux density for each slits made on the contact electrode in the vacuum interrupter with axial magnetic field type using 3-dimension finite element analysis. It has been known that the presence of an axial magnetic field parallel to the current flow in the arc plasma can increase the high current breaking capacity of vacuum interrupter by carrying out the arc plasma from constricted mode to diffusion mode. The axial magnetic field is created of itself by current flow in the segments of coil electrode behind the contact electrode. The analyzed results show that if the slits are made in the contact electrode, they can increase the current density and axial magnetic flux density in the contact electrode surface and at the gap distance, which is due to decrease the effect of eddy currents flowing in the contact electrode. The phase shift due to eddy currents, defined 3s time difference between the maximum value of current and axial magnetic field, is decreased still more by increasing the number of slits made in the contact electrode at the center point of gap distance. These results demonstrate that 3-dimension finite element analysis has a great deal of merits in the development and evaluation of new electrode at the design of vacuum interrupter.

Effect of an AI underlayer on the Growth of Carbon Nanotubes and Their Field Emission Characteristics (알루미늄 하부층이 탄소나노튜브의 성장 및 전계방출 특성에 미치는 영향)

  • Lee, Seung-Hwan;Goak, Jeung-Choon;Lee, Han-Sung;Lee, Nae-Sung
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.21 no.2
    • /
    • pp.162-172
    • /
    • 2008
  • We studied the effect of an Al underlayer on the growth of carbon nanotubes (CNTs) and their field emission characteristics, First of all, CNTs were grown on the Invar catalyst layers with different thickness of 1 to 10 nm, showing that the CNT length was saturated for the catalyst 5 nm or thicker. The CNTs grown on the 5-nm-thick catalyst were ${\sim}10{\mu}m$ long and ${\sim}30nm$ in diameter. Second, an Al underlayer was applied between the catalyst layer and the Ti diffusion barrier to reduce the diameters of CNTs for better field emission properties by forming spherical Al oxide particles on which smaller catalyst nanoparticles would occur. The optimal thickness of an Al underlayer underneath the 5-nm-thick catalyst was ${\sim}15nm$, producing the CNTs with the length of ${\sim}15{\mu}m$ and the diameter of ${\sim}15nm$. The field emission measurements, following the tape activation, showed that the thinner and longer CNTs gave rise to better field emission performance with the lower turn-on and threshold electric fields.

Characteristics of DC Corona Discharges Caused at the tip of a Needle-shaped Electrode Placed in the Homogeneous Electric Fields (균등전계 중에 놓인 침상 전극의 끝단에서 발생한 직류 코로나방전 특성)

  • Kim, Tae-Ki;Kim, Seung-Min;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.11
    • /
    • pp.74-81
    • /
    • 2015
  • In the measurement of atmospheric static electric field, it is important to know characteristics of corona discharges caused at the tip of test electrode. This paper presents the fundamental data of DC corona discharges that occurred at the tip of a needle-shaped electrode placed in the homogeneous background electric field which simulates the atmospheric static field under thundercloud. The major characteristics of interest for this purpose are the polarity effect of corona discharges and the magnitudes and time intervals of corona current pulses. The experimental set-up consists of the plate-to-plate configuration with a needle-shaped protrusion, DC power supply, and voltage and current measuring devices. As a result of experiments, the polarity dependence of corona pulses is significantly pronounced. The time intervals between successive corona pulses in the negative polarity is much longer than those in the positive polarity. The time intervals for both polarities is drastically decreased as the applied electric field is increased. Also the magnitudes of the positive corona pulses are slightly changed with an increase in applied electric field, but those of the negative corona pulses are linearly increased with increasing the applied electric fields.

A of Radiation Field with a Developed EPID

  • Y.H. Ji;Lee, D.H.;Lee, D.H.;Y.K. Oh;Kim, Y.J.;C.K. Cho;Kim, M.S.;H.J. Yoo;K.M. Yang
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2003.09a
    • /
    • pp.67-67
    • /
    • 2003
  • It is crucial to minimize setup errors of a cancer treatment machine using a high energy and to perform precise radiation therapy. Usually, port film has been used for verifying errors. The Korea Cancer Center Hospital (KCCH) has manufactured digital electronic portal imaging device (EPID) system to verify treatment machine errors as a Quality Assurance (Q.A) tool. This EPID was consisted of a metal/fluorescent screen, 45$^{\circ}$ mirror, a camera and an image grabber and could display the portal image with near real time KIRAMS has also made the acrylic phantom that has lead line of 1mm width for ligh/radiation field congruence verification and reference points phantom for using as an isocenter on portal image. We acquired portal images of 10$\times$10cm field size with this phantom by EPID and portal film rotating treatment head by 0.3$^{\circ}$, 0.6$^{\circ}$ and 0.9$^{\circ}$. To check field size, we acquired portal images with 18$\times$18cm, 19$\times$19cm and 20$\times$20cm field size with collimator angle 0$^{\circ}$ and 0.5$^{\circ}$ individually. We have performed Flatness comparison by displaying the line intensity from EPID and film images. The 0.6$^{\circ}$ shift of collimator angle was easily observed by edge detection of irradiated field size on EPID image. To the extent of one pixel (0.76mm) difference could be detected. We also have measured field size by finding optimal threshold value, finding isocenter, finding field edge and gauging distance between isocenter and edge. This EPID system could be used as a Q.A tool for checking field size, light/radiation congruence and flatness with a developed video based EPID.

  • PDF

An Experimental Study on the Effect of Electric Field the Ornithine Decarboxylase Activity Change of Myeloid Cells According to Ionizing Radiation Exposure (이온화방사선 피폭에 의한 골수세포의 Ornithine Decarboxylase 활성도의 변화에 대한 전계장의 영향에 관한 실험적 연구)

  • 정문호
    • Journal of Environmental Health Sciences
    • /
    • v.21 no.1
    • /
    • pp.78-85
    • /
    • 1995
  • Ornithine decarboxylase(ODC) is an indicate enzyme in carcinogenesis. We divided Sprague Dawley rats into six groups: control, electric field exposure, X-ray only irradiation, X-ray irradiation with electric field exposure group, Sr-90 injected group and Sr-90 and electric field complex exposure group. The ODC activity was measured in rat's bone marrow cell every week. The results were summarized as follows: The ODC activitied was increased in X-ray irradiated, Sr-90 injected and Sr-90 and electric field complex exposed group as compared with that of control(p<0.05). The ODC activity was increased comparing that of control neither in X-ray and electric field complex exposed group nor electric field only exposed group. This result suggests that the electric field doesn't have myeloid carcinogenicity and myeloid cancer incidence caused by ionized radiation is suppressed by electric field exposure.

  • PDF

A removal characteristics of NOx at the cylinderical plasma reactor with magnetic field (자계가 인가된 원통형 플라즈마 반응기에서 질소산화물(NOx)의 제거특성)

  • Lee, Dong-Hoon;Lee, Tae-Geun;Oh, Jung-Min;Lee, Doo-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.05b
    • /
    • pp.104-108
    • /
    • 2004
  • The effect of magnetic field was measured on NOx removal for cylinder-wire plasma reactor with magnetic field applied to electric field vertically. Power was supplied to plasma reactor using rotating spark gap switch. Consumption power increased with increasing discharge voltage. When magnetic field was applied to electric field vertically, consumption power was less than that without magnetic field because of lorenz's force. NOx removal rate of plasma reactor with magnetic field were higher, 10-15%, than that of plsama reactor without magnetic field. And NOx removal rate decreased with increasing gas flow rate.

  • PDF

Source Identification in an Interior Sound Field (실내 공간에서의 음원 탐지 방법)

  • 김양한;최영철
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.12 no.7
    • /
    • pp.520-526
    • /
    • 2002
  • Identification of noose sources, their locations and strengths, has been taken great attention. The methods that can identify noise sources normally assume that noise sources are located in a free field. However, the sound in a reverberant field consists of that coming directly from the source plus sound reflected or scattered by the walls or objects in the field. In contrast to the exterior sound field. reflections are added to sound field. Therefore, we haute to consider the reverberation effect on the source identification method. The main objective of this paper is to identify noise source in the reverberant field. At fist, we try to identify noise sources in a rigid wall emc;psire using the beamforming method. In many cases of practical interest, the wall has admittance so that random reflections occur in an enclosure. In this paper, we assumed the complex reverberant field in the enclosure to be the sum of plane caves with random Incidence and magnitude. Then we try to explain effects of reverberant field at interior source identification.

Effect of Porcelain/Polymer Interface on the Microstructure, Insulation Characteristics and Electrical Field Distribution of Hybrid Insulators (자기재/폴리머 계면이 하이브리드 애자의 미세구조, 절연특성과 전계분포에 미치는 영향)

  • Cho, Jun-Young;Kim, Woo-Seok;An, Ho-Sung;An, Hee-Sung;Kim, Tae-wan;Lim, Yun-Seog;Bae, Sung-Hwan;Park, Chan
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.30 no.9
    • /
    • pp.558-565
    • /
    • 2017
  • Hybrid insulators that have the advantages of both porcelain (high mechanical strength and chemical stability) as well as polymer (light weight and high resistance to pollution) insulators, can be used in place of individual porcelain and polymer insulators that are used for both mechanical support as well as electrical insulation of overhead power transmission lines. The most significant feature of hybrid insulators is the presence of porcelain/polymer interfaces where the porcelain and polymer are physically bonded. Individual porcelain and polymer insulators do not have such porcelain/polymer interfaces. Although the interface is expected to affect the mechanical/electrical properties of the hybrid insulator, systematic studies of the adhesion properties at the porcelain/polymer interface and the effect of the interface on the insulation characteristics and electric field distribution of the hybrid insulator have not been reported. In this study, we fabricated small hybrid insulator specimens with various types of interfaces and investigated the effect of the porcelain/polymer interface on the microstructure, insulating characteristics, and electric field distribution of the hybrid insulators. It was observed that the porcelain/polymer interface of the hybrid insulator does not have a significant effect on the insulating characteristics and electric field distribution, and the hybrid insulator can exhibit electrical insulating properties that are similar or superior to those of individual porcelain and polymer insulators.

Field Application of Egg and Larval Parasitic Fungi and Chemicals for Controlling Root-knot Nematodes on Some Medicinal Herb (몇종의 선충천적 진균과 화학약제를 이용한 약용작물 뿌리혹선충 방제효과 검토)

  • 박소득;추연대;정기채;심용구;최영연
    • Korean journal of applied entomology
    • /
    • v.32 no.1
    • /
    • pp.105-114
    • /
    • 1993
  • Series of studies were conducted to establish biological and chemical control method for Meloidogyne spp to medical herbs by applied of nematophagous fungi, Arthrobotrys spp, Fusarium spp, and egg parastic fungi, Paecilomyces lilacinus were applied for root-knot nematodes on medicinal herbs, Paeonia albiflora, Codonopsis lanceolata, Cnidium officinale. The results are as follow. In pot experiments, The no. of root gall and egg mass and larvae of Cnidium officinale. The results are as follow. In pot experiments. The no. of root gall and egg mass and larvae of Cnidium officinale, Codonopsis lanceolata, Paeonia japonica lowered in P. Lilacinus treated plots compare to untreated control plots. But A. thaumasia F. oxysporum treated plots were less effective. Effect of egg parasitic fungi and chemical treatment at divided root of Paeonia japonica after sterilized in pot were increased in the fresh weight, root weight, control effect in P. lilacinus treated plots as chemical, Carbo G treated plots compare to untreted control plots. I field experiment, the number of root gall, egg mass and nematode density of Paeonia were also suppressed in P. lilacinus treated plots. It was very effective continuous 2 years and transplanting time on Paeonia japonica infested soil with the M. hapla in field in both region, Chillgok and Euisung treated P. lilacinus as chemical treated plots. Soaking effect of insecticide for Paeonia japonica at diving shoot before transplating in pot were effective for 12hours immersion into 1,000 ppm of Benlate T + Mep Ec, Benlate T + Fenthion EC in pot and field Experiment. In the Examination of fungi activily on P.japonica field 1 year after soil treatment, Number of spore of P. lilacinus were 1,000~1,300 in 3 region except Euisung.

  • PDF