• Title/Summary/Keyword: Field demonstration

Search Result 235, Processing Time 0.022 seconds

Performance evaluation of new curvature estimation approaches (Performance Evaluation of New Curvature Estimation Approaches)

  • 손광훈
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.22 no.5
    • /
    • pp.881-888
    • /
    • 1997
  • The existing method s for curvature estimation have a common problem in determining a unique smoothong factor. we previously proposed two approaches to overcome that problem: a constrained regularization approach and a mean field annealing approach. We consistently detected corners from the perprocessed smooth boundary obtained by either the constrained eglarization approach or the mean field annealing approach. Moreover, we defined corner sharpness to increase the robustness of both approaches. We evaluate the performance of those methods proposed in this paper. In addition, we show some matching results using a two-dimensional Hopfield neural network in the presence of occlusion as a demonstration of the power of our proposed methods.

  • PDF

Proposal and Throughput Analysis of a Management Scheme for MTC Device Clustering Service (MTC 장치 클러스터링 서비스 관리 방안 제안 및 성능분석)

  • Kim, Yeon Geun;Min, Sang Won
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.16 no.1
    • /
    • pp.157-165
    • /
    • 2017
  • Intelligent transportation systems are currently being developed for elemental technology development of cooperative intelligent transport systems, which enable vehicles to communicate with each other or reduce the risk of traffic accidents, We have been defining and standardizing services according to the purpose of solving traffic safety problems depending on countries. Therefore, in this study, the developed countries of V2X(vehicle-to-everything) based on USA, Europe, Japan, etc., analyzed the service cases selected in the field demonstration stage after completion of the element technology devanalyzed the service cases selected in the field demonstration stage after completion of the element technology development, and to suggest the direction of futureelopment, and to suggest the direction of future policy direction.

Procedure Development and Qualification of the Phased Array Ultrasonic Testing for the Nuclear Power Plant Piping Weld (원자력발전소 배관 용접부 위상배열 초음파검사 절차서 개발 및 기량검증)

  • Yoon, Byung-Sik;Yang, Seung-Han;Kim, Yong-Sik;Lee, Hee-Jong
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.30 no.4
    • /
    • pp.317-323
    • /
    • 2010
  • The manual ultrasonic examination for the nuclear power plant piping welds has been demonstrated by using KPD(Korean Performance Demonstration) generic procedure. For automated ultrasonic examination, there is no generic procedure and it should be qualified by using applicable automated equipment. Until now, most of qualified procedures used pulse-echo technique and there is no qualified procedure using phased array technique. In this study, data acquisition and analysis software were developed and phased-array transducer and wedge were designed to implement phased array technique for nuclear power plant in-service inspection. The developed procedure are qualified for performance demonstration for the flaw detection, length sizing and depth sizing. The qualified procedure will be applied for the field examination in the nuclear power plant piping weld inspection.

Analysis of Regulatory Sandbox Usage by IT Companies (IT기업의 규제샌드박스 활용 분석)

  • Seokju Song;Daihwan Min;Hanjin Lee
    • Journal of Information Technology Services
    • /
    • v.22 no.5
    • /
    • pp.109-124
    • /
    • 2023
  • This study aims to apply the concept of regulatory stringency to the regulatory sandbox with a fresh perspective. The regulatory sandbox is a system that gives opportunities under certain conditions to new technologies or businesses that have not been launched due to inadequacy or insufficiency in legal systems. Previous research on regulatory sandboxes has mainly focused on discussions about their impact on specific technologies or business domains. This study attention to the results according to the evaluations. Among them, whether special cases for demonstration can evolve into official permission has garnered significant attention. For this study, among the cases that passed the regulatory sandbox evaluation from February, 2019, to December, 2022, 162 cases in the field of ICT convergence were selected. The evaluation results were classified into three groups 'positive interpretation (Fast Track)', 'temporary permission', and 'special case for demonstration.' Each case was assigned to one of the three groups. Through the comparative analysis, the common characteristics and differences were summarized. Then, this study explored improvement measures to pass a less restrictive regulatory sandbox. The analysis of the cases revealed that the differences in each evaluation result were attributed to variations in the technological characteristics and user protection features. Considering these differences, as well as the higher weight and importance of the preparation stage for sandbox application, this study suggested a three-step approach to prepare for temporary permission and positive interpretation rather than special case for demonstration. In addition, this thesis discussed the policy limitations of the regulatory sandbox mechanism in South Korea and the limitations of the current study. Hopefully, the results of this study would be beneficial to individuals and companies, particularly venture companies and startups seeking to develop new technologies or businesses and utilize regulatory sandboxes.

Evaluation of thermal performance for solar cooling and heating system (태양열 냉.난방 및 급탕 시스템 열성능)

  • Kwak, Hee-Youl;Joo, Hong-Jin;Lee, Ho
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.04a
    • /
    • pp.203-208
    • /
    • 2009
  • This paper presents demonstration study results derived through field testing of a solar assisted cooling and heating system for the library of a cultural center building located in Gwangju, Korea. The area of demanded cooling and heating for building was about 350m2. Solar hot water was delivered by means of a 200m2 array of evacuated tubular solar collector (ETSC) to drive a single-effect (LiBr/H2O) absorption chiller of 10RT nominal cooling capacity. From March in 2008 to February in 2009, demonstration test were performed for solar cooling and heating system. After experiments and analysis, this study found that solar thermal system was 84% for the solar hot water supply and 12% for space heating and 4% for space cooling.

  • PDF

The Development of monitoring system for demonstration research of solar hot water heater for dwellings (실증연구를 위한 주택용 태양열 온수기 모니터링 시스템 개발)

  • 양동조;김재열;한재호;송경석;김우진
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2004.10a
    • /
    • pp.156-161
    • /
    • 2004
  • The application of solar energy, in the field of alternative energy, was on the increase tendency. In the case of advanced nations, through continuous R&D, solar hot water heater with high efficiency has been used for the house and the industrial process on business, advanced nations were reached up the experimental stage of solar generation system. But, the actual circumstance of the domestic has been not accomplished the popularization of solar hot water heater and the settlement of it which is the fundamental stage of the solar energy usage. This trouble, the domestic was flooded with small enterprise for producing solar hot water heater, was caused by the popularization and the production without verification of performance. To supply the monitoring program for evaluating solar hot water heater, this research was purpose to improve the technical development of the enterprise for producing solar-heat hot-water-boiler and served as an aid for the enlargement and the popularization on solar energy.

  • PDF

Considerations on the Long-term Reliability of On-line Partial Discharge Ceramic Sensor for Thermal Power Generators and its Demonstration in the Field

  • Sun, Jong-Ho;Youn, Young-Woo;Hwang, Don-Ha;Kang, Dong-Sik
    • Journal of Electrical Engineering and Technology
    • /
    • v.7 no.1
    • /
    • pp.103-108
    • /
    • 2012
  • The present study describes the considerations on the long-term reliability of the on-line partial discharge (PD) ceramic sensor for thermal power generators. Voltage acceleration aging tests were carried out under continuous and impulsive thermal aging at more than $100^{\circ}C$, considering the practical service environment. Experimental results show that the sensors have a life that could last for more than 100 years, excellent dielectric characteristics, and insulation strength. In addition, the ceramic on-line PD sensors were installed in a thermal power generator in Korea for demonstration. The results of the PD calibration and test voltage application prove that the on-line ceramic sensors have satisfactory performances for on-line PD measurement.

Theoretical resistance in cylindrical electrodes with conical tip

  • Hong, Chang-Ho;Kim, Jin-Seop;Chong, Song-Hun
    • Geomechanics and Engineering
    • /
    • v.30 no.4
    • /
    • pp.337-343
    • /
    • 2022
  • The electrical resistivity method is a well-known geophysical method for observing underground conditions, (such as anomalies) and the properties of soil and rock (such as porosity, saturation, and pore fluid characteristics). The shape of electrodes used in an electrical resistivity survey depends on the purpose of the survey and installation conditions. Most electrodes for field applications are cylindrical for sufficient contact with the ground, while some are conically sharpened at their tips for convenient penetration. Previous study only derived theoretical equations for rod-shaped electrodes with spherical tips. In this study, the theoretical resistance for two cylindrical electrodes with conical tips is derived and verified experimentally. The influence of the penetration depth and tip on the measurement is also discussed.

A phenomenological study of paramedic student's experience on simulation (응급구조학과 학생의 시뮬레이션 경험에 관한 현상학적 연구)

  • Baek, Mi-Lye
    • The Korean Journal of Emergency Medical Services
    • /
    • v.16 no.3
    • /
    • pp.63-75
    • /
    • 2012
  • Purpose : This study was attempted to explore the paramedic student's experience on simulation education. Methods : Data were collected through in-depth interviews from 15 paramedic students. The study was analyzed by phenomenological method, specifically Colaizzi's method. From the protocol, significant statements were organized into formulated meanings. Results : The formulated meanings were identified 35 themes, 12 theme clusters, and 6 categories. The 6 categories include burden of demonstration, role experience as a paramedic, confidence in field treatment, sense of disjunction caused by difference from real situation, realization and learning by oneself, and sense of stability from hypothetical situation. Conclusion : This study suggested that, even though some negative perceptions were observed, simulation education will fit as a replacement for the field practice of paramedic's students given that more field-like practice environment and repetitive simulation education are present.

Measurement of Magnetic and Electric Field from Kwachun Power Transmission Lines (과천 송전선로 전자계 측정)

  • Kim, D.W.;Ryu, C.Y.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.11
    • /
    • pp.353-356
    • /
    • 1996
  • Early this year the construction of new high voltage power lines have been forced to stop due to the demonstration of residents in Kwa-chun. According to mutual agreement between the residents and Korea Electric Power Corporation, electromagnetic field(EMF) from present power lines was measured and EMF after completion of new power lines was estimated. The results show that EMF near power lines Is relatively low, and EMFnear electric substation is quite high due to the short distance between the power lines and ground. For 4 conduction 345kV line, magnetic field decreases to 3mG at the distance of 50m from the power line.

  • PDF