• Title/Summary/Keyword: Field correction

Search Result 743, Processing Time 0.026 seconds

DEVELOPMENT OF ULTRA-LIGHT 2-AXES SUN SENSOR FOR SMALL SATELLITE

  • Kim, Su-Jeoung;Kim, Sun-Ok;Moon, Byoung-Young;Chang, Young-Keun;Oh, Hwa-Suk
    • Journal of Astronomy and Space Sciences
    • /
    • v.22 no.1
    • /
    • pp.47-58
    • /
    • 2005
  • This paper addresses development of the ultra-light analog sun sensors for small satellite applications. The sun sensor is suitable for attitude determination for small satellite because of its small, light, low-cost, and low power consumption characteristics. The sun sensor is designed, manufactured and characteristic-tested with the target requirements of ${\pm}60^{\circ}$ FOV (Field of View) and pointing accuracy of ${\pm}2^{\circ}$. Since the sun sensor has nonlinear characteristics between output measurement voltage and incident angle of sunlight, a higher order calibration equation is required for error correction. The error was calculated by using a polynomial calibration equation that was computed by the least square method obtained from the measured voltages vs. angles characteristics. Finally, the accuracies of 1-axis and 2-axes sun sensors, which consist of 2 detectors, are compared.

VICARIOUS GROUND CALIBRATION OF AIRBORNE MULTISPECTRAL SCANNER (AMS) DATA BASED ON FIELD CAMPAIGN

  • Lee, Kwang-Jae;Kim, Yong-Seung;Han, Jong-Gyu
    • Proceedings of the KSRS Conference
    • /
    • v.1
    • /
    • pp.184-187
    • /
    • 2006
  • The radiometric correction is prerequisite to derive both land and ocean surface properties from optical remote sensing data. Radiometric calibration of remotely sensed data has traditionally been accomplished by means of vicarious ground calibration techniques. The purpose of this study is to calibrate the radiometric characteristic of Airborne Multispectral Scanner (AMS) by field campaign. In order to calibrate the AMS data, four different spectral tarps which are 3.5%, 23%, 35%, and 53% were validated by GER-3700 that is the surface reflectance measurement equipment and were utilized. After validation of the spectral tarps, each reflectance from the spectral tarps was compared with Digital Number (DN) value of AMS. There was very high correlation between tarp reflectance and DN value of AMS so that radiometric calibration of AMS data has been accomplished by those results. The calibrated AMS data were validated with in-situ measured reflectance data from artificial and natural target. Also QuickBird image data were used for verifying the results of AMS radiometric calibration. This presentation discusses the results of the above tests.

  • PDF

A Study on the Adjustment of the Magnetic Compass on the Vessel alongside the Wharf (접안된 선박에 있어서 자기 compass 의 자착수정에 관한 연구)

  • 이상집;노태현
    • Journal of the Korean Institute of Navigation
    • /
    • v.12 no.2
    • /
    • pp.23-32
    • /
    • 1988
  • This paper offers a method of magnetic compass adjustment for the vessel alongside the wharf using newly designed magnetic north former, which makes the same magnetic field-change as the turning vessel does. The characteristics of the magnetic north former was examined by observing the deviation curves of the magnetic compass installed on the compass deviascop at laboratory. The magnetic north former consists of A and B arms which hold the permanent bar magnets at the both ends of each arm. The arm is to rotae in the horizontal plane about the vertical axis fixed at the center boss of the magnetic compass and it is to compensate the horizontal plane about the vertical axis fixed at the center boss of the magnetic compass and it is to compensate the horizontal component of the earth's field. The B arm makes the artificial magnetic north around the magnetic compass for every ship's heading. The results of investigation are summarized as follows ; 1. The observation and correction of magnetic compass deviation can be done without swinging the ship, of the effect of D coefficient is negligible. 2. The residual deviation curve of the magnetic compass depends on the accuracy of deduced value of ship's multplier($\lambda$). 3. The errors due to the inaccuracy of deduced value of ship's multiplier change in the same way as the B and C coefficient do.

  • PDF

On the Implementation of CODEC for the Double-Error Correction Reed-Solomon Codes (2중 오류정정 Reed-Solomon 부호의 부호기 및 복호기 장치화에 관한 연구)

  • Rhee, Man-Young;Kim, Chang-Kyu
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.26 no.2
    • /
    • pp.10-17
    • /
    • 1989
  • The Berlekamp-Massey algorithm, the method of using the Euclid algorithm, and Fourier transforms over a finite field can be used for the decoding of Reed-Solomon codes (called RS codes). RS codes can also be decoded by the algorithm that was developed by Peterson and refined by the Gorenstein and Zierler. However, the decoding of RS codes using the Peterson-Gorenstein-Zieler algorithm offers sometimes computational or implementation advantages. The decoding procedure of the double-error correcting (31,27) Rs code over the symbol field GF ($2^5$) will be analyized in this paper. The complete analysis, gate array design, and implementation for encoder/decoder pair of (31.27)RS code are performed with a strong theoretical justification.

  • PDF

Study for Reducing the Near Field Interference of Belly Sting Model Support with Fairing (페어링을 이용한 벨리 스팅 모형지지부의 직접 간섭효과 감소방안 연구)

  • Kim, Namgyun;Lee, Jaeho;Cha, Kyunghwan;Ko, Sungho
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.48 no.10
    • /
    • pp.753-763
    • /
    • 2020
  • A wind tunnel test of 29.7% scaled model of NASA Common Research Model with belly model support was performed in small low speed wind tunnel. The static aerodynamic forces and moments of CRM were measured with belly sting support configuration. Pitching moments of belly sting with various fairings were compared and small interference fairing shape was found. The belly sting model support interference and reducing effect of fairing shapes with CFD analysis.

Development of the Near/Far Absolute Gain Measurement System Using an Extrapolation Technique (외삽기법을 이용한 안테나의 원 ${\cdot}$ 근역장 절대이득 측정시스템 개발)

  • Shin, Joon;Kang, Chan-Koo;Kim, Jeong-Hwan;Chung, Nak-Sam
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.27 no.2
    • /
    • pp.31-38
    • /
    • 1990
  • An antenna gain measurement system using an extrapolation technique is described. The technique is similar to the usual two-antenna method for absolute gain measurement system, but involves the measurement of the received signal as a function of seperation in short distances, and the signal-versus-seperation data is processed in a way that allows an extrapolation of the signal to "infinite" seperation. In this technique it is possible to obtain the near field gain as function of distance by combining the far field gain and a proximity correction factor. The results of gain measurements of standard gain horn antennas and OEG (open ended waveguide) antennas are also presented.

  • PDF

Off-axis Two-mirror System with Wide Field of View Based on Diffractive Mirror

  • Meng, Qingyu;Dong, Jihong;Wang, Dong;Liang, Wenjing
    • Journal of the Optical Society of Korea
    • /
    • v.19 no.6
    • /
    • pp.604-613
    • /
    • 2015
  • An unobstructed off-axis two-mirror system is presented in this paper. First a suitable initial configuration is established based on third-order aberration theory. In order to achieve a wide field of view (FOV) with high image quality , the diffractive mirror is adopted in the two-mirror system to increase the optimization freedom and the aberration relationship between diffractive phase coefficients and Zernike coefficients is derived. Furthermore, a complete comparison design example with a focal length of 1200 mm, F-number of 12, and FOV of 40° × 2° is given to verify the aberration correction ability of the diffractive mirror. The system average wavefront error is 0.007 λ (λ=0.6328 μm) developed from 0.061 λ when the system didn’t adopt the diffractive mirror. In this system the phase modulation function of the diffractive mirror is established as an even function of x, so we could obtain a symmetrical imaging quality about the tangential plane, and the symmetric aberration performance also brings considerable convenience to alignment and testing for the system.

Review on Conservative Treatment of Spinal Scoliosis (척추측만증의 보존적 치료에 대한 문헌적 고찰 - 국내 발표 논문을 중심으로 -)

  • Lee, Moon-Kyu;Lee, Gil-Jae;Song, Yun-Kyung;Lim, Hyung-Ho
    • The Journal of Churna Manual Medicine for Spine and Nerves
    • /
    • v.4 no.1
    • /
    • pp.103-117
    • /
    • 2009
  • Objective : The purpose of this study is to research the trend of the theses related to conservative treatment of spinal scoliosis and to establish the direction of futher studies into the spinal scoliosis Methods : We reviewed and analyzed all theses published by Korean research institution. And these theses were classified by field of study, theses type, symptoms and illnesses, evaluation methods, treatment type, clinical outcome. Result and conclusion : 1. Classified by the major field of study, oriental rehabilitation medicine and physical education accounted for 9 papers, followed by 6 in orthopedics medicine. 2. Upon classifying theses according to research method type, clinical trial theses were more than casuistic theses. 3. Upon classifying theses according to symptoms and illnesses in scoliosis, the most was idiopathic scoliosis. 4. Theses used mostly Cobb's angle for evaluating in scoliosis. 5. Some few of theses used chuna therapy for treating in scoliosis. 6. Chuna therapies side by side with correction exercises were the most efficient for treating in scoliosis.

  • PDF

Design of A Reed-Solomon Decoder for UWB Systems (UWB 시스템 용 Reed-Solomon 복호기 설계)

  • Cho, Yong-Suk
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.36 no.4C
    • /
    • pp.191-196
    • /
    • 2011
  • In this paper, we propose a design method of Reed-Solomon (23, 17) decoder for UWB using direct decoding method. The direct decoding algorithm is more efficient for the case of relatively small error correction capability. The proposed decoder requires only 9 $GF(2^m)$ multipliers in obtaining the error-locator polynomial and the error-evaluator polynomial, whereas other decoders need about 20 multipliers. Thus, the attractive feature of this decoder is its remarkable simplicity from the point of view of hardware implementation. Futhermore, the proposed decoder has very simple control circuit and short decoding delay. Therefore this decoder can be implemented by simple hardware and also save buffer memory which stores received sequence.

Development of Real-time Precision Spraying System Using Machine Vision and DGPS (기계시각과 DGPS를 이용한 실시간 정밀방제 시스템 개발)

  • 조성인;정재연;김유용;남기찬;이중용
    • Journal of Biosystems Engineering
    • /
    • v.27 no.2
    • /
    • pp.143-150
    • /
    • 2002
  • Several researches for site-specific weed control have tried to increase accuracy of weed detection with machine vision technique. However, there is a problem which needs substantial time to perform site-specific spraying. Therefore, new technology for real-time precision spraying system is needed. This research was executed to develope the new technology to estimate weed density and size in real time, and to conduct a real-time site-specific spraying. It would effectively reduce herbicide amounts applied for a crop field. The real-time precision spraying system consisted of a Differential Global Positioning System (DGPS) with an error of 2 cm, a machine vision system, a geomagnetic sensor for correction of view point of CCD camera and an automatic sprayer with separately controlled nozzle. The weed density was calculated with comparison between position information and a pre-designed electronic map. The position information was obtained in real time using the DGPS and the machine vision. The electronic map contained a position database of crops automatically constructed when seeding. The developed system was tested on an experimental field of Seoul National University. Success rate of the spraying was about 61%.