• Title/Summary/Keyword: Field configuration

Search Result 957, Processing Time 0.029 seconds

Configuration assessment of MR dampers for structural control using performance-based passive control strategies

  • Wani, Zubair R.;Tantray, Manzoor A.;Iqbal, Javed;Farsangi, Ehsan Noroozinejad
    • Structural Monitoring and Maintenance
    • /
    • v.8 no.4
    • /
    • pp.329-344
    • /
    • 2021
  • The use of structural control devices to minimize structural response to seismic/dynamic excitations has attracted increased attention in recent years. The use of magnetorheological (MR) dampers as a control device have captured the attention of researchers in this field due to its flexibility, adaptability, easy control, and low power requirement compared to other control devices. However, little attention has been paid to the effect of configuration and number of dampers installed in a structure on responses reduction. This study assesses the control of a five-story structure using one and two MR dampers at different stories to determine the optimal damper positions and configurations based on performance indices. This paper also addresses the fail-safe current value to be applied to the MR damper at each floor in the event of feedback or control failure. The model is mathematically simulated in SIMULINK/MATLAB environment. Linear control strategies for current at 0 A, 0.5 A, 1 A, 1.5 A, 2 A, and 2.5 A are implemented for MR dampers, and the response of the structure to these control strategies for different configurations of dampers is compared with the uncontrolled structure. Based on the performance indices, it was concluded that the dampers should be positioned starting from the ground floor, then the 2nd floor followed by 1st and rest of the floors sequentially. The failsafe value of current for MR dampers located in lower floors (G+1) should be kept at a higher value compared to dampers at top floors for effective passive control of multi-story structures.

Mechanical behavior of coiled tubing over wellhead and analysis of its effect on downhole buckling

  • Zhao, Le;Gao, Mingzhong;Li, Cunbao;Xian, Linyun
    • Steel and Composite Structures
    • /
    • v.44 no.2
    • /
    • pp.199-210
    • /
    • 2022
  • This study build finite element analysis (FEA) models describing the bending events of coiled tubing (CT) at the wellhead and trips into the hole, accurately provide the state of stress and strain while the CT is in service. The bending moment and axial force history curves are used as loads and boundary conditions in the diametrical growth models to ensure consistency with the actual working conditions in field operations. The simulation diametrical growth results in this study are more accurate and reasonable. Analysis the factors influencing fatigue and diametrical growth shows that the internal pressure has a first-order influence on fatigue, followed by the radius of the guide arch, reel and the CT diameter. As the number of trip cycles increase, fatigue damage, residual stress and strain cumulatively increase, until CT failure occurs. Significant residual stresses remain in the CT cross-section, and the CT exhibits a residual curvature, the initial residual bending configuration of CT under wellbore constraints, after running into the hole, is sinusoidal. The residual stresses and residual bending configuration significantly decrease the buckling load, making the buckling and buckling release of CT in the downhole an elastic-plastic process, exacerbating the helical lockup. The conclusions drawn in this study will improve CT models and contribute to the operational and economic success of CT services.

A CFD ANALYSIS ON THE INFLUENCE OF OPERATING CONDITIONS AND EJECTOR CONFIGURATION ON THE HYDRODYNAMICS AND MASS TRANSFER CHARACTERISTICS OF GAS-LIQUID EJECTOR

  • Utomo, Tony;Jin, Zen-Hua;Yi, Chung-Seub;Jeong, Hyo-Min;Chung, Han-Shik
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2817-2822
    • /
    • 2007
  • The purpose of this paper is to study the influence of operating condition and ejector geometries on the hydrodynamics and on the mass transfer characteristic of ejector. The CFD results were validated with available experimental data. Flow field analyses and predictions of ejector performance were also carried out. Variation on the operating conditions was made by varying the gas-liquid flow rate ratio in the range of 0.2 to 1.2. The ejector configuration was also varied on the length to diameter ratio of mixing tube ($L_M/D_M$) in the range of 4 to 10. CFD studies show that at $L_M/D_M$ 5.5, the volumetric mass transfer coefficient increases with respect to gas flow rates. Meanwhile, at $L_M/D_M$ 4, the plot of volumetric mass transfer coefficient to gas-liquid flow rates ratio reach maximum at gas-liquid flow rates ratio of 0.6. This study also shows that volumetric mass transfer coefficient decrease with respect to the increase of mixing tube length.

  • PDF

Flow Visualization Study on Vortices over a Stealth UCAV Configuration (스텔스 무인전투기 형상의 와류 거동에 대한 흐름가시화 연구)

  • Kang, Seung-Hee;Lee, Do-Kwan;Hyun, Jae-Soo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.35 no.6
    • /
    • pp.467-473
    • /
    • 2007
  • Flow visualization study to qualitatively define the flow field over a stealth UCAV(Uninhabited Combat Air Vehicle) configuration in a water tunnel has been conducted to clarify the basic aerodynamic performance. The test was performed at freestream velocity of 12.7 cm/sec which was corresponding to a Reynolds number of $1.4{\times}10^4$ based on mean aerodynamic chord. The development and breakdown of vortices illuminated by using dye were compared to the previous force and moment data. It was shown that the effect of the vortices generated by the main-body and junction are dominant in the low angle-of-attack region. However, in the high angle-of-attack region, the vortex generated by the fore-body mainly influenced the aerodynamic performance of the model.

Aerodynamic Performance Dependency on the Geometric Shape and Mounting Location of OSRVM (OSRVM의 형상 및 장착 위치가 차량의 공력성능에 미치는 영향)

  • Han, Hyun Wook;Park, Hyun Ho;Kim, Moon Sang;Ha, Jong Paek;Kim, Yong Nyun
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.21 no.3
    • /
    • pp.30-42
    • /
    • 2013
  • This study investigates the effects of OSRVM mounting location and its configurations such as stalk height and housing height on the aerodynamic performance of the passenger car. In order to validate the flow solver, FLUENT which is very well known commercial code, the flow field around an Ahmed Body was analyzed numerically and compared with the experimental data. The predicted aerodynamic performance and flow patterns around a car show good agreements with the experimental data. Mounting location and stalk height should be designed while OSRVM is mounted on the car to evaluate the aerodynamic performance precisely. Housing height, however, may be designed independent of the car because the aerodynamic interference between housing height and car configuration is negligible.

Width-Dependent Transition of Magnetic Domain Configuration in Nanostructured CoFe/Pt Multilayered Nanowires

  • Je, Soong-Geun;Lee, Jae-Chul;Kim, Kab-Jin;Min, Byoung-Chul;Shin, Kyung-Ho;Choe, Sug-Bong
    • Journal of Magnetics
    • /
    • v.17 no.4
    • /
    • pp.242-244
    • /
    • 2012
  • We report on the basis of experiments that magnetic domain structures exhibit a transition between single and dendrite domains with respect to the width of ferromagnetic nanowires. This transition is directly observed in CoFe/Pt multilayered nanowires having a width in the range of 580 nm to 4.2 ${\mu}m$ with a magnetic force microscope. Nanowires wider than 1.5 ${\mu}m$ show typical dendrite domain patterns, whereas the nanowires narrower than 690 nm exhibit single domain patterns. The transition occurs gradually between these widths, which are similar to the typical widths of the dendrite domains. Such a transition affects the strength of the domain wall propagation field; this finding was made by using a time-resolved magneto-optical Kerr effect microscope, and shows that the domain wall dynamics also exhibit a transition in accordance with the domain configuration.

Design Case Study of Geosynthetic Reinforced Segmental Retaining Walls in Tiered Configuration (다단식 보강토 옹벽의 설계 사례 연구)

  • 유충식;허병주
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.6
    • /
    • pp.115-125
    • /
    • 2003
  • This paper presents the results of design case study on soil-reinforced segmental retaining walls in tiered configuration. Six different field walls were examined to investigate the appropriateness of their designs within the context of the current design guidelines based on limit equilibrium. Slope stability analysis against the compound failure mode, which is frequently ignored during design, was additionally performed based on the method recommended by FHWA design guidelines. The results indicate that the as-built designs of some of the walls examined do not meet the minimum factors of safety for the external and Internal stabilities, and for the compound failure mode. The implications of the findings from this study are discussed.

A Study on the Design of Touch Free Eddy-Current Brake (비접촉 와전류 제동기의 설계에 관한 연구)

  • Ha, Gyeong-Ho;Hong, Jeong-Pyo;Kim, Gyu-Tak;Gang, Do-Hyeon
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.49 no.2
    • /
    • pp.77-83
    • /
    • 2000
  • This paper deals with the design of a touch free eddy-current brake for high speed transportation systems by using 2-dimensional Finite Element Method (2-D FEM). The eddy current brake systems have to equipped with maximum braking force and deceleration at the given volume or mass, high braking force at small rate, attraction forces as small as possible and stable construction. The parameters, such as the number of pole, electric ampere-turns and slot width have influence on these braking characteristics. For the magnet to satisfy above-mentioned performance in high speed, the braking performance according to variation of the parameters are analyzed by the 2-D FEM. In addition, the magnet stack width is determined from equivalent stack width that is calculated by solution of the Field with scalar potential. From these results, the magnet of optimized configuration with maximum braking force and minimum attraction force is designed by the process of detail design.

  • PDF

Electrical Properties of a Single ZnO Nanowire in a four-probe Configuration (단일 ZnO 나노선 4단자 소자의 전기적 특성)

  • Kim, Kang-hyun;Kang, Hae-yong;Yim, Chan-young;Jeon, Dae-young;Kim, Hye-young;Kim, Gyu-Tae;Lee, Jong-Soo;Kang, Woun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.18 no.12
    • /
    • pp.1087-1091
    • /
    • 2005
  • Four-probe device of single ZnO nanowire was fabricated by electron beam lithography. Electrical characterizations in a two-probe and a four-probe configuration with a back-gate were carried out to clarify the relative contribution of the contact and the intrinsic part in a ZnO nanowire. I-V characteristic in four-probe measurement showed an ohmic behavior with a high conductivity, 100 S/cm, which was better than those of two-probe measurement by 10 times. At the same values of the current between two-probe and four-probe, the net voltage applied inside the nanowire were extracted with calculated voltages at the contact. Four-probe current-gate voltage characteristics showed bigger tendencies than those of two-probe measurement at low temperatures, indicating the reduced gate dependence in two-Probe measurements by the existence of the contact resistance.

Implementation and Design of Digital Instruments System using FPGA (FPGA를 이용한 디지털 계측 시스템의 설계 및 구현)

  • Choi, Hyun Jun;Jang, Seok Woo
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.9 no.2
    • /
    • pp.55-61
    • /
    • 2013
  • A field-programmable gate array (FPGA) is an integrated circuit designed to be configured by a customer or a designer after manufacturing. The FPGA configuration is generally specified using a hardware description language (HDL), similar to that used for an application-specific integrated circuit (ASIC) (circuit diagrams were previously used to specify the configuration, as they were for ASICs, but this is increasingly rare). Contemporary FPGAs have large resources of logic gates and RAM blocks to implement complex digital computations. In this paper, we implement a system of digital instrumentation using FPGA. This system consists of the trigger part, memory address controller part, control FSM part, Encoder part, LCD controller part. The hardware implement using FPGA and the verification of the operation is done in a PC simulation. The proposed hardware was mapped into Cyclone III EP2C5Q208 from Altera and used 1,700(40%) of Logic Element (LE). The implemented circuit used 24,576-bit memory element with 6-bit input signal. The result from implementing in hardware (FPGA) could operate stably in 140MHz.