• Title/Summary/Keyword: Field Reduction Factor

Search Result 231, Processing Time 0.02 seconds

Factor Analysis for Exploratory Research in the Distribution Science Field (유통과학분야에서 탐색적 연구를 위한 요인분석)

  • Yim, Myung-Seong
    • Journal of Distribution Science
    • /
    • v.13 no.9
    • /
    • pp.103-112
    • /
    • 2015
  • Purpose - This paper aims to provide a step-by-step approach to factor analytic procedures, such as principal component analysis (PCA) and exploratory factor analysis (EFA), and to offer a guideline for factor analysis. Authors have argued that the results of PCA and EFA are substantially similar. Additionally, they assert that PCA is a more appropriate technique for factor analysis because PCA produces easily interpreted results that are likely to be the basis of better decisions. For these reasons, many researchers have used PCA as a technique instead of EFA. However, these techniques are clearly different. PCA should be used for data reduction. On the other hand, EFA has been tailored to identify any underlying factor structure, a set of measured variables that cause the manifest variables to covary. Thus, it is needed for a guideline and for procedures to use in factor analysis. To date, however, these two techniques have been indiscriminately misused. Research design, data, and methodology - This research conducted a literature review. For this, we summarized the meaningful and consistent arguments and drew up guidelines and suggested procedures for rigorous EFA. Results - PCA can be used instead of common factor analysis when all measured variables have high communality. However, common factor analysis is recommended for EFA. First, researchers should evaluate the sample size and check for sampling adequacy before conducting factor analysis. If these conditions are not satisfied, then the next steps cannot be followed. Sample size must be at least 100 with communality above 0.5 and a minimum subject to item ratio of at least 5:1, with a minimum of five items in EFA. Next, Bartlett's sphericity test and the Kaiser-Mayer-Olkin (KMO) measure should be assessed for sampling adequacy. The chi-square value for Bartlett's test should be significant. In addition, a KMO of more than 0.8 is recommended. The next step is to conduct a factor analysis. The analysis is composed of three stages. The first stage determines a rotation technique. Generally, ML or PAF will suggest to researchers the best results. Selection of one of the two techniques heavily hinges on data normality. ML requires normally distributed data; on the other hand, PAF does not. The second step is associated with determining the number of factors to retain in the EFA. The best way to determine the number of factors to retain is to apply three methods including eigenvalues greater than 1.0, the scree plot test, and the variance extracted. The last step is to select one of two rotation methods: orthogonal or oblique. If the research suggests some variables that are correlated to each other, then the oblique method should be selected for factor rotation because the method assumes all factors are correlated in the research. If not, the orthogonal method is possible for factor rotation. Conclusions - Recommendations are offered for the best factor analytic practice for empirical research.

Influence of ventilation rate on the aerodynamic interference between two extra-large indirect dry cooling towers by CFD

  • Ke, S.T.;Liang, J.;Zhao, L.;Ge, Y.J.
    • Wind and Structures
    • /
    • v.20 no.3
    • /
    • pp.449-468
    • /
    • 2015
  • Current wind-resistance designs of large-scale indirect dry cooling towers (IDCTs) exclude an important factor: the influence of the ventilation rate for radiator shutter on wind loads on the outer surfaces of the tower shell. More seemingly overlooked aspects are the effects of various ventilation rates on the wind pressure distribution on the tower surfaces of two IDCTs, and the feature of the flow field around them. In order to investigate the effects of the radiator shutter ventilation rates on the aerodynamic interference between IDCTs, this paper established the numerical wind tunnel model based on the Computational Fluid Dynamic (CFD) technology, and analyzed the influences of various radiator shutter ventilation rates on the aerodynamic loads acting upon a single and two extra-large IDCTs during building, installation, and operation stages. Through the comparison with the results of physical wind tunnel test and different design codes, the results indicated that: the influence of the ventilation rate on the flow field and shape coefficients on the outer surface of a single IDCT is weak, and the curve of mean shape coefficients is close to the reference curve provided by the current design code. In a two-tower combination, the ventilation rate significantly affects the downwind surface of the front tower and the upwind surface of the back tower, and the larger positive pressure shifts down along the upwind surface of the back tower as the ventilation rate increases. The ventilation rate significantly influences the drag force coefficient of the back tower in a two-tower combination, the drag force coefficient increases with the ventilation rate and reaches the maximum in a building status of full ventilation, and the maximum drag coefficient is 11% greater than that with complete closure.

Evaluation of extruded pellet for growth performance of olive flounder Paralichthys olivaceus in Jeju farm field (제주도 넙치 양식현장에서 배합사료 성장 평가)

  • Kim, Kang-Woong;Kang, Yong-Jin;Kim, Kyoung-Duck;Son, Maeng-Hyun;Choi, Se-Min;Bai, Sung-Chul C.;Lee, Kyeong-Jun
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.42 no.6
    • /
    • pp.604-608
    • /
    • 2009
  • This study was conducted to evaluate extruded pellet (EP) diet compared with a raw fish moist pellet (MP) diet for flounder, Paralichthys olivaceus on field feeding experiments in Jeju area. The experimental EP diet (juvenile, growing and adult) was prepared based on the former studies on nutrient requirements and feed ingredient of flounder. Fish were distributed randomly to each aquarium as a group of 102,300 fish (initial mean weight 97 g) in field experiment I and reared randomly to each aquarium as a group of 40,000 fish (initial mean weight 120 g) in field experiment II. In field feeding experiment I conducted in commercial flounder farm, survival, wt. gain (94-1,090 g), feed efficiency and condition factor of fish fed experimental EP were comparable to those of fish fed MP, but considerably higher protein efficiency ratio were observed in fish fed experimental EP. In field feeding experiment II, no significant difference was observed in final mean weight of fish fed the experimental EP (1,234 g) and MP (1,286 g), and any noticeable problem caused by feeding the experimental EP was not found during the whole period of feeding trial. Survival of fish fed the experimental EP was lower than that of MP, and there was no significant difference in feed efficiency between the fish fed experimental EP and MP. Therefore, these results strongly suggest that diet EP could be developed to replace MP diet for the marketable size (1.3 kg) of production for flounder without adverse effects on growth performance. In particular, abdominal dropsy and reduction of condition factor, which are frequently occurred in commercial EP feeding farms, were not observed in flounder fed experimental EP.

The Learning Motivation Improvement Program in Children with Attention-Deficit Hyperactivity Disorder(ADHD) (주의력결핍 과잉행동장애 아동에서 학습동기증진프로그램)

  • NamKoong, Sun;Ahn, Dong-Hyun;Lee, Yang-Hee
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.18 no.1
    • /
    • pp.58-65
    • /
    • 2007
  • Objectives : Motivational factor is a unique contributor to the typically poor academic performance of children with ADHD. However, few study has directly intervened learning motivation in children with ADHD. We conducted this study to explore the direct effects of the learning motivation improvement program applied to children with ADHD. Method The program was designed in order to increase an interest-inducing educational intervention, an academic skills integration, a basic learning activity (reading, writing, and math), and children's self-esteem. We conducted the program twice a week (total 10 sessions) and assessed learning motivation, teaming attitude, self-esteem, academic performance, and problem behaviors of participating children. Results : After the program, teachers reported improvement in teaming motivation. In addition, parents notified sisnificant reduction of problem behaviors. Children reported improvement in a few domains of teaming motivation and learning attitude. Conclusion : While loaming motivation is regarded as an important factor in education, there have been few studies considering this issue in both educational and psychiatric fields. The teaming motivation improvement would be needed in both field in order to reduce the deficits in academic performance in children with ADHD.

  • PDF

Study on the subgrade reaction modulus$(K_{30})$ and strain modulus$(E_v)$ (지반반력계수$(K_{30})$와 변형률계수$(E_v)$에 대한 고찰)

  • Kim, Dae-Sang;Choi, Chan-Yong;Kim, Seong-Jung;Yu, Jin-Young;Yang, Sin-Chu
    • Journal of the Korean Society for Railway
    • /
    • v.10 no.3 s.40
    • /
    • pp.264-270
    • /
    • 2007
  • Two modulus, strain modulus $(E_v)$ and subgrade reaction modulus $(K_{30})$ are being used as a standard for bearing stiffness in Korea Railroad design. The first is used in Europe and the other is used in Japan. The methodologies to obtain the two modulus are similar in using plate. But testing methods are different in loading to plate. Therefore, according to soil strain range, there should be large gap in not only computations of deformation modulus but also the necessary time to test. At first, this paper focuses on the two kinds of test methods to evaluate bearing stiffness. Secondly, based on elastic theory, the theory to obtain the two coefficients are studied thoroughly. Finally, the correlations between the two coefficients were analyzed and evaluated based on the field test results more than 38 places. The matching values for subgrade and ground between $K_{30}$ and $E_{v2}$ are proposed with the consideration of the proposed strain reduction factor (1.5 for subgrade and 3 for ground) and safety factor, respectively.

Hybrid of the fuzzy logic controller with the harmony search algorithm to PWR in-core fuel management optimization

  • Mahmoudi, Sayyed Mostafa;Rad, Milad Mansouri;Ochbelagh, Dariush Rezaei
    • Nuclear Engineering and Technology
    • /
    • v.53 no.11
    • /
    • pp.3665-3674
    • /
    • 2021
  • One of the important parts of the in-core fuel management is loading pattern optimization (LPO). The loading pattern optimization as a reasonable design of the in-core fuel management can improve both economic and safe aspects of the nuclear reactor. This work proposes the hybrid of fuzzy logic controller with harmony search algorithm (HS) for loading pattern optimization in a pressurized water reactor. The music improvisation process to find a pleasing harmony is inspiring the harmony search algorithm. In this work, the adjustment of the harmony search algorithm parameters such as the bandwidth and the pitch adjustment rate are increasing performance of the proposed algorithm which is done through a fuzzy logic controller. Hence, membership functions and fuzzy rules are designed to improve the performance of the HS algorithm and achieve optimal results. The objective of the method is finding an optimum core arrangement according to safety and economic aspects such as reduction of power peaking factor (PPF) and increase of effective multiplication factor (Keff). The proposed approach effectiveness has been tried in two cases, Michalewicz's bivariate function problem and NEACRP LWR core. The results show that by using fuzzy harmony search algorithm the value of the fitness function is improved by 15.35%. Finally, with regard to the new solutions proposed in this research it could be used as a trustworthy method for other optimization issues of engineering field.

A Study on Valuation of Micro-pressure Wave Reduction Technology Using Fuzzy Comprehensive Evaluation (퍼지 기법을 이용한 소음 저감 원천기술의 기술가치 산정에 관한 연구)

  • Won, Yoo-Kyung;Kim, Dong-Jin
    • The Journal of the Korea Contents Association
    • /
    • v.17 no.10
    • /
    • pp.231-240
    • /
    • 2017
  • Although the value of technology is evaluated by various methods, the result of technology valuation is different from evaluator and evaluation methods. Also the uncertainty on the result occurs with respect to the evaluation factors and evaluation model which should be considered. In the case of lack of data or comparison target, the credibility of the technology valuation result could be unsure. To decrease uncertainty of the technology valuation, Fuzzy concept and Fuzzy Comprehensive Evaluation method are applied instead of using existing methods which evaluate technology value(level) by the number. In the research, we firstly devide evaluation criteria into technology value factor and business value factor and evaluate the technology level for micro pressure wave reduction technology which has been developed in Korea. Technology value factor is marked as high level with 46%, and business value factor is very high with 44%, and the overall level of technology is evaluated between very high and high. It helps to compare to other technology in the rivalry by the factors as it can evaluate the value of technology by factors. The technology valuation method which is applied in this research is expected to use on analyzing technology level of new technology or alternative technology in many different field.

Assessment of Deformation Modulus in Gneiss for Road Tunnel (도로터널에서 편마암 구간의 암반변형계수 산정 연구)

  • Kim, Nag-Young;Kim, Sung-Hwan;Chung, Hyung-Sik
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.3 no.1
    • /
    • pp.27-35
    • /
    • 2001
  • Four road tunnels, which consists of biotite gneiss and granite gneiss and shows a similar geological conditions, were selected in this study. Laboratory and field tests, the rock mass rating for the four tunnels were conducted. A regression analysis was performed to find out the correlations of test results. It was proposed an equation of reduction factor which can assess the deformation modulus for biotite gneiss and granite gneiss. It was also found that there was a close correlation between Q and RQD in four tunnels according to the analysis between RMR and Q, RMR and RQD, Q and RQD and laboratory and field tests.

  • PDF

Fabrication of Novel Metal Field Emitter Arrays(FEAs) Using Isotropic Silicon Etching and Oxidation

  • Oh, Chang-Woo;Lee, Chun-Gyoo;Park, Byung-Gook;Lee, Jong-Duk;Lee, Jong-Ho
    • Journal of Electrical Engineering and information Science
    • /
    • v.2 no.6
    • /
    • pp.212-216
    • /
    • 1997
  • A new metal tip fabrication process for low voltage operation is reported in this paper. The key element of the fabrication process is that isotropic silicon etching and oxidation process used in silicon tip fabrication is utilized for gate hole size reduction and gate oxide layer. A metal FEA with 625 tips was fabricated in order to demonstrate the validity of the new process and submicron gate apertures were successfully obtained from originally 1.7$\mu\textrm{m}$ diameter mask. The emission current above noise level was observed at the gate bias of 50V. The required gate voltage to obtain the anode current of 0.1${\mu}\textrm{A}$/tip was 74V and the emission current was stable above 2${\mu}\textrm{A}$/tip without any disruption. The local field conversion factor and the emitting area were calculated as 7.981${\times}$10\ulcornercm\ulcorner and 3.2${\times}$10\ulcorner$\textrm{cm}^2$/tip, respectively.

  • PDF

Optimal current angle control method of interior permanent magnet Synchronous Motors (매입형 영구자석 동기전동기의 최적 전류각 제어)

  • 김명찬;김종구;홍순찬
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.45 no.3
    • /
    • pp.352-357
    • /
    • 1996
  • Recently, Permanent Magnet Synchronous Motor(PMSM) drives are widely used for industrial applications due to its high efficiency and high power factor control strategy. PMSM generally have two classifications such as the SPMSM(Surface Permanent Magnet Synchronous Motors) and IPMSM(Inter Permanent Magnet Synchronous Motors). IPMSA has economical merits over SPMSM in higher speed range, mechanical robustness, and higher power rate by the geometric difference. The maximum torque operation in IPMSM is realized by the current angle control which is to utilize additional reluctance torque due to a rotor saliency. In traction, spindle and compressor drives, constant power operation with higher speed range are desirable. This is simply achieved in the DC motor drives by the reduction of the field current as the speed is increased. However, in the PMSM, direct control of the magnet flux is not available. The airgap flux can be weakened by the appropriate current angle control to demagnetize. In this paper, the control method of optimal current vector in IPMSM is described in order to obtain the maximum torque or maximum output with the speed and load variations. The applied algorithm is realized by the proto system with torque and speed control Experimental results show this approach is satisfied for the high performance servo applications. (author). 6 refs., 9 figs., 1 tab.

  • PDF