• Title/Summary/Keyword: Field Measured

Search Result 7,155, Processing Time 0.039 seconds

Quantitative Analysis of Digital Radiography Pixel Values to absorbed Energy of Detector based on the X-Ray Energy Spectrum Model (X선 스펙트럼 모델을 이용한 DR 화소값과 디텍터 흡수에너지의 관계에 대한 정량적 분석)

  • Kim Do-Il;Kim Sung-Hyun;Ho Dong-Su;Choe Bo-young;Suh Tae-Suk;Lee Jae-Mun;Lee Hyoung-Koo
    • Progress in Medical Physics
    • /
    • v.15 no.4
    • /
    • pp.202-209
    • /
    • 2004
  • Flat panel based digital radiography (DR) systems have recently become useful and important in the field of diagnostic radiology. For DRs with amorphous silicon photosensors, CsI(TI) is normally used as the scintillator, which produces visible light corresponding to the absorbed radiation energy. The visible light photons are converted into electric signal in the amorphous silicon photodiodes which constitute a two dimensional array. In order to produce good quality images, detailed behaviors of DR detectors to radiation must be studied. The relationship between air exposure and the DR outputs has been investigated in many studies. But this relationship was investigated under the condition of the fixed tube voltage. In this study, we investigated the relationship between the DR outputs and X-ray in terms of the absorbed energy in the detector rather than the air exposure using SPEC-l8, an X-ray energy spectrum model. Measured exposure was compared with calculated exposure for obtaining the inherent filtration that is a important input variable of SPEC-l8. The absorbed energy in the detector was calculated using algorithm of calculating the absorbed energy in the material and pixel values of real images under various conditions was obtained. The characteristic curve was obtained using the relationship of two parameter and the results were verified using phantoms made of water and aluminum. The pixel values of the phantom image were estimated and compared with the characteristic curve under various conditions. It was found that the relationship between the DR outputs and the absorbed energy in the detector was almost linear. In a experiment using the phantoms, the estimated pixel values agreed with the characteristic curve, although the effect of scattered photons introduced some errors. However, effect of a scattered X-ray must be studied because it was not included in the calculation algorithm. The result of this study can provide useful information about a pre-processing of digital radiography.

  • PDF

Report on the External Audits Conducted by Korean Society of Medical Physics (한국의학물리학회 선형가속기 외부 품질관리 실시 현황보고)

  • Huh, Hyun Do;Cho, Kwang Hwan;Cho, Sam Ju;Choi, Sang Hyoun;Kim, Dong Wook;Hwang, Ui-Jung;Kim, Ki Hwan;Min, Chul Kee;Choi, Tae Jin;Oh, Young Kee;Lee, Seoung Jun;Park, Dahl;Park, Sung-Kwang;Ji, Young Hoon
    • Progress in Medical Physics
    • /
    • v.24 no.4
    • /
    • pp.315-322
    • /
    • 2013
  • The aim of this work is to verify the self-quality assurances in medical institutions in Korea through the external audits by the group of experts and have a mutual discussion of the systematic problems. In order to validate the external audits 30 of 80 medical institutions across the nation were picked out considering the regional distribution and the final 25 institutions applied voluntarily to take part in this work. The basic rules were setup that any information of the participants be kept secrete and the measurements be performed with the dosimetry system already verified through intercomparision. The outputs for 2 or more photon beams, the accuracy of gantry rotation and collimator rotation and the poistional accuracy of MLC movement were measured. The findings for the output measurement showed the differences of -0.8%~4.5%, -0.79%~3.01%, and -0.7%~0.07% with respect to that of the verified dosimetry system for the 6MV, 10MV, and 15MV, respectively. For the reference absorbed dose 8 (16%) of 50 photon beams in 25 medical institutions differed 2.0% or greater from the reference value. The coincidences of Field size with x-ray beam and radiation isocenters of Gantry roration and collimator rotation gave the results of within ${\pm}2$ mm for every institute except 2 institutions. The positional accuracy of MLC movement agreed to within ${\pm}1$ mm for every institute. For the beam qualities of 6 MV photon beams kQ values showed the distribution within 0.4% between maximum and minimum. For the protocols 21 institutions (84%) used absorbed dose to water based protocol while 4 insitutions (16%) used air kerma based one. 22 institutions employed the SSD technique while 3 institutions did the SAD one. External audit plays an important role in discovering the systematic problems of self-performing Quality Assurances and having in depth discussion for mutual complementation. Training experts of international level as well as national support system are required so that both the group of experts of medical physicists and government laboratory could perform together periodical and constant external audits.

Construction and Validation of a Data Synchronization Server supporting OMA DS Standards (OMA DS 표준을 지원하는 자료동기화 서버 구축 및 적합성 검증)

  • Pak, Ju-Geon;Park, Kee-Hyun
    • Journal of the Korea Society of Computer and Information
    • /
    • v.16 no.5
    • /
    • pp.79-91
    • /
    • 2011
  • In this paper, a DS (Data Synchronization) server for mobile communication environments is constructed and the suitability and the performance of its operations are validated. The DS server provides a way to update the newest data and keep data consistency for clients (mobile devices). In addition, the DS server constructed in this paper supports various synchronization types, and detects all changes and conflicts. In case of data conflicts, the DS server resolves the conflicts according to the several policies implemented in this work. The DS server conforms to the OMA(Open Mobile Alliance) DS standard protocol for interoperability with other mobile devices and servers. In addition to the transmission-by record scheme proposed by the OMA DS standard protocol, the DS server constructed in this paper also provides the transmission-by field scheme for the enhancement transmission performance between the server and clients. In order to validate its operations, data synchronization between the DS server and the SCTS (SyncML Conformance Test Suit), the suitability validation tool provided by the OMA, is performed. The validation results show that the DS server constructed in this paper satisfies all of the test cases except the Large Object function. The Large Object function will be implemented later because the function is not needed for the personal information synchronization process which this paper aims for. Also, synchronization times of the DS server are measured while increasing the number of data and clients. The results of the performance evaluations demonstrate that the DS server is scalable, in the sense that it has not suffered from any serious bottlenecks with respect to the number of data and clients. We expect that this work will provide a framework for various studies in the future for improving mobile DS operations.

Root-zone Application of Insecticides in Gelatin Capsules for the Control of Rice Insect Pests (살충제(gelatin capsule 입)의 수도근부처리에 의한 수도해충 방제효과)

  • Choi S. Y.;Heu M. H.;Chung K. Y.;Kang Y. S.;Kim H. K.
    • Korean journal of applied entomology
    • /
    • v.14 no.3 s.24
    • /
    • pp.147-153
    • /
    • 1975
  • During 1973 a field experiment was carried out to evaluate effectiveness of the root zone application of insecticides in medical gelatin capsules for control of several rice insect pests and dwarf virus disease. At three days after transplanting the capsules were pushed by hand about 2.5cm into the soil, near roots of Tongil rice plants. At the given day intervals number of leaf-and plant-hoppers on the hills were recorded by direct count, and dead hearts and white heads by stem borers and dwarf virus infected hills were observed in the experiment plots. Finally grain yields were measured. The percentages of dead hearts and white heads in all the plots were too low for evaluating the effectiveness of insecticides against the striped rice borers. Carbofuran of the insecticides tested was relatively effective against green rice leafhopper (Nephotettixcincticeps) and small brown planthopper (Laodelphax striatellus), although small number of insects on the hills were recorded. Relatively small number of white-backed planthopper (Sogatella furcifera) was occured in the BPMC and Diazinon treated plots. BPMC and Carbofuran were highly effective against the brown planthopper (Nilaparvata lugens) to 80 days after treatment. Incidence of dwarf virus disease was least in the plots of Carbofuran treatment. The highest grain yield was recorded in the plots treated with Carbofuran, and it seemed to be related with good protection from the dwarf virus disease and leaf-and plant-hoppers.

  • PDF

The Effects of Self-Congruity and Functional Congruity on e-WOM: The Moderating Role of Self-Construal in Tourism (중국 관광객의 온라인 구전에 대한 자아일치성과 기능일치성의 효과: 자기해석의 조절효과를 중심으로)

  • Yang, Qin;Lee, Young-Chan
    • The Journal of Information Systems
    • /
    • v.25 no.1
    • /
    • pp.1-23
    • /
    • 2016
  • Purpose Self-congruity deals with the effect of symbolic value-expressive attributes on consumer decision and behavior, which is the theoretical foundation of the "non-utilitarian destination positioning". Functional congruity refers to utilitarian evaluation of a product or service by consumers. In addition, recent years, social network services, especially mobile social network services have created many opportunities for e-WOM communication that enables consumers to share personal consumption related information anywhere at any time. Moreover, self-construal is a hot and popular topic that has been discussed in the field of modem psychology as well as in marketing area. This study aims to examine the moderating effect of self-construal on the relationship between self-congruity, functional congruity and tourists' positive electronic word of mouth (e-WOM). Design/methodology/approach In order to verify the hypotheses, we developed a questionnaire with 32 survey items. We measured all the items on a five-point Likert-type scale. We used Sojump.com to collect questionnaire and gathered 218 responses from whom have visited Korea before. After a pilot test, we analyzed the main survey data by using SPSS 20.0 and AMOS 18.0, and employed structural equation modeling to test the hypotheses. We first estimated the measurement model for its overall fit, reliability and validity through a confirmatory factor analysis and used common method bias test to make sure that whether measures are affected by common-method variance. Then we tested the hypotheses through the structural model and used regression analysis to measure moderating effect of self-construal. Findings The results reveal that the effect of self-congruity on tourists' positive e-WOM is stronger for tourists with an independent self-construal compared with those with interdependent self-construal. Moreover, it shows that the effect of functional congruity on tourists' positive e-WOM becomes salient when tourists' self-construal is primed to be interdependent rather than independent. We expect that the results of this study can provide important implications for academic and practical perspective.

Effect of Fluoride Recharging on Fluoride Release and Surface Properties of Orthodontic Bracket Adhesives (불소 적용 후 교정용 브라켓 접착제 종류에 따른 불소 재흡수성과 표면 변화에 관한 연구)

  • Byeon, Seon Mi
    • Journal of dental hygiene science
    • /
    • v.18 no.4
    • /
    • pp.218-226
    • /
    • 2018
  • The aim of this study was to compare fluoride release and surface changes according to different orthodontic bracket adhesives the application of fluoride products. We used non-fluoridated composite resin Transbond fluoridated composite resins Blugloo and LightBond, resin-modified glass ionomer Rely $X^{TM}$ Luting 2, and conventional glass ionomer Fuji $I^{(R)}$. Fluoride release of five orthodontic bracket adhesives and fluoride release ability after application of three fluoride products (1.23% acidulated phosphate fluoride gel, Tooth Mousse $Plus^{(R)}$, Fluor Protector, and a toothbrush with sodium fluoride-containing toothpaste) were measured using a fluoride electrode that was connected to an ion analyzer. After 4 weeks of fluoride application, the surface roughness and surface morphology were examined using a surface roughness tester and field emission scanning electron microscopy. The amounts of fluoride release were observed not only on application of Tooth Mousse $Plus^{(R)}$ and Fluor Protector on resin-modified glass ionomer Rely $X^{TM}$ Luting 2 and Fuji $I^{(R)}$, but also during tooth brushing using fluoride-containing toothpaste. After application of Tooth Mousse $Plus^{(R)}$, except Transbond XT, the surface roughness increased, and all orthodontic adhesives showed a partial drop of micro-particle filler. On application of 1.23% acidulated phosphate fluoride gel on all orthodontic bracket adhesives, their surface roughness increased. To bond the orthodontic bracket, resin-modified glass ionomer Rely $X^{TM}$ Luting 2 and Fuji $I^{(R)}$ adhesives are highly recommended if the amount of fluoride release is considered to confer a preventative effect on dental caries, and among the fluoride products, Tooth Mousse $Plus^{(R)}$ and Fluor Protector are better than 1.23% acidulated phosphate fluoride gel, and these are expected to prevent dental caries even during tooth brushing with fluoride-containing toothpaste.

Development of Industrial Embedded System Platform (산업용 임베디드 시스템 플랫폼 개발)

  • Kim, Dae-Nam;Kim, Kyo-Sun
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.47 no.5
    • /
    • pp.50-60
    • /
    • 2010
  • For the last half a century, the personal computer and software industries have been prosperous due to the incessant evolution of computer systems. In the 21st century, the embedded system market has greatly increased as the market shifted to the mobile gadget field. While a lot of multimedia gadgets such as mobile phone, navigation system, PMP, etc. are pouring into the market, most industrial control systems still rely on 8-bit micro-controllers and simple application software techniques. Unfortunately, the technological barrier which requires additional investment and higher quality manpower to overcome, and the business risks which come from the uncertainty of the market growth and the competitiveness of the resulting products have prevented the companies in the industry from taking advantage of such fancy technologies. However, high performance, low-power and low-cost hardware and software platforms will enable their high-technology products to be developed and recognized by potential clients in the future. This paper presents such a platform for industrial embedded systems. The platform was designed based on Telechips TCC8300 multimedia processor which embedded a variety of parallel hardware for the implementation of multimedia functions. And open-source Embedded Linux, TinyX and GTK+ are used for implementation of GUI to minimize technology costs. In order to estimate the expected performance and power consumption, the performance improvement and the power consumption due to each of enabled hardware sub-systems including YUV2RGB frame converter are measured. An analytic model was devised to check the feasibility of a new application and trade off its performance and power consumption. The validity of the model has been confirmed by implementing a real target system. The cost can be further mitigated by using the hardware parts which are being used for mass production products mostly in the cell-phone market.

Relationship between S-Phase Fraction and Survival Time in Patients with Primary Squamous Lung Cancer (편평상피성 폐암에 있어서 S-Phase Fraction과 생존기간과의 관계)

  • Jung, Byung-Hak;Kang, Jeong-Seong;Chang, Keun;Jeong, Eun-Taik;Chung, Hun-Taeg;Moon, Hyung-Bae
    • Tuberculosis and Respiratory Diseases
    • /
    • v.40 no.6
    • /
    • pp.669-676
    • /
    • 1993
  • Background: DNA content analysis of human solid tumor is now widely performed by flow cytometric study. One of the most interesting and potentially important observation in this field is that proliferative activity(S-Phase fraction of cell cycle) may profoundly affect prognosis. Method: S-Phase fraction(SPF) have been measured by flow cytometric method using tumor cells isolated from paraffin embedded tissue. To evaluate the prognostic significance, SPF of squamous lung cancer cell was assessed in 21 patients who died without any specific treatment. Results: 1) Mean survival time of squamous lung cancer patients was 225(${\pm}162$) days. Survival time were shortened, when TNM stage and PS scale were advanced. 2) Mean value of SPF of squamous lung cancer patients was 23.4(${\pm}11.3$)%. SPF had nothing to do with advance of TNM stage and PS scale. 3) Mean survival time of high SPF group(more than 20% of cell proliferation cycle) and low SPF group were 153(${\pm}99$) days and 342(${\pm}180$) days(p<0.01). In each identical TNM stage and PS scale, there were also statistic significant differences in mean survival time between high and low SPF group. Conclusion: On multivariate analysis including TNM stage and performance status, SPF was the significant and independent prognostic factor in the primary squamous lung cancer patients group.

  • PDF

Study on the Growth and the Yield of Ecotype of Garlics in Main Producing Districts in Korea (주산단지(主産團地) 마늘의 생태형(生態型)에 따른 생장(生長)과 수량(收量)에 관(關)한 연구(硏究))

  • Ra, Woo-Hyun;Park, Kuen-Woo
    • Korean Journal of Environmental Agriculture
    • /
    • v.6 no.1
    • /
    • pp.67-75
    • /
    • 1987
  • The major objectives of this study were to find out the growth and yield of two ecotypes of Korean garlic in main garlic producing districts in Korea. The data were collected by the field survey which had been conducted at 270 township in 58 major garlic production countries throughout the country on 10th, 20th, and 30th day of every month from 1982 to 1984. The results of this study were as follow: 1) Sowing period of garlic of southern and northern ecotype were around September 20 and October 20, respectively. 2) Average number of plants per $3.3m^2$ of the southern and northern ecotype were 123 and 100, respectively. 3) Leaf emergence time of southern ecotype was before the beginning of winter (November) and that of northern ecotype was from early February till April. 4) Stepwise multiple regression analysis showed that the plant heights measured on November 30 for southern ecotype and on June 30 for northern ecotype most adequately predicted the yield of garlic. The relationship between yield and plant height were as follows: Southern ecotype; Y=571.56+5.34X Northern ecotype; Y=251.81+5.45X where Y is yield expressed in Kg/l0a and X is height in cm at the respective date. 5) The number of leaves increased until harvest in both ecotypes. At harvest, the number of leaves in southern and northern ecotype were 10 and 8, respectively. Number of leaves counted on January 20 for southern ecotype and on June 20 for northern ecotype correlated best with the yield of the ecotypes. 6) The highest senescent portion of southern ecotype and northern ecotype were seen on January 30 and May 30, respectively. Stepwise multiple regression analysis showed that the senescent portion of southern ecotype counted on January 30 and that of northern ecotype on June 20 mostly affected the yield. 7) Average yield of southern and northern ecotype at the main garlic producing districts were 771 and 652Kg/10a, respectively.

  • PDF

BASIC STUDIES ON THE PHYSICAL FITNESS OF KOREAN SCHOOL BOYS AND GIRLS (한국(韓國) 어린이 및 청소년(靑少年)의 체력(體力)에 관(關)한 기초연구(基礎硏究))

  • Park, H.K.;Paik, K.S.;Yoo, M.J.;Min, H.S.;Chung, T.S.;Oh, S.B.;Lim, M.J.;Hong, C.K.
    • The Korean Journal of Physiology
    • /
    • v.2 no.2
    • /
    • pp.101-135
    • /
    • 1968
  • As physical fitness measured was muscle strength (hand grips, leg extention, back lift, and arm pull and thrust), skinfold thickness (5 different sites), circulatory function (resting heart rate and blood pressure), speed (kinesiological analysis during 100m sprint, record, maximal and final speed), motor function (50 meter dash, ball throwing, standing broad jump, and pull-ups), maximal aerobic power (maximum oxygen intake by field running method), muscle power (leg and arm by inertia ergometer), and general endurance (maximum endurance running time on the treadmill at the speed of 5 MPH and grade of 15.5%) of 1131 Korean children (boys 572, girls 559) aged of 6 to 17 years, who were randomly sampled from 24 primary, middle and high schools at the two districts of Seoul and KyungKi. The results are summarized as follows: 1) The status (height and weight) of the children was almost same as that of the previously reported Korean and Japanese children of same ages. 2) Muscle strength was a gained linearly with geting age in the boys and girls but there was a little improvement in girls aged of 13 years or more. 3) The mean skin fold thickness was increased linearly with geting ages in both sexes, but the girls from 12 to 17 years of age were increased rapidly, and maximum value was 17mm, while boys was 7.0 mm. 4) In the circulatory function, the resting heart rate was decreased, but the blood pressure was increased with ages in both sexes within the normal limits. 5) The maximum and final speed during 100 meter sprint increases with age in boys but girls who are 12 years old or older, were not improved any mere. The patterns of running were same in both sexes, and maximum speed reached at about 30 meters from starting line. 6) The motor function was increased with age in both sexes, but there was no improvement in 12 years of age or older girls. More over records of all functions except standing broad jump was less than those of Japanese in the same age, respectively. 7) The maximum oxygen intake (MOI) was increased considerably with ages and maximum values were 2.93 L/min (boys) and 2.09 L/min (girls) at the age of 17years. This result was almost same as that of the Japanese and Easter Island population, but the value was lower than that of Europe. The average of the maximum oxygen intake per kg body weight per minute from 9 to 17 years of age were around 53 ml in the boys and 42 ml in the girls. 8) Muscle power was increased linearly with ages in boys while there was relatively a little increment in girls. The maximum values of leg muscle in boys and girls at the 17 years of age were 0.168 and 0.088 horse power, respectively. 9) The maximum endurance running time was increased considerably from the age of 9 in boys, while there was no improvement in girls. The maximum values were 6.0 min and 1.8 min, respectively.

  • PDF