• Title/Summary/Keyword: Field Measured

Search Result 7,143, Processing Time 0.035 seconds

Variation Analysis of Elevation within a Rice Paddy Field (수도작 포장의 고저차 분석)

  • Sung J.H.;Jang S.W.
    • Journal of Biosystems Engineering
    • /
    • v.31 no.3 s.116
    • /
    • pp.188-193
    • /
    • 2006
  • Elevation differences within a paddy field relate strongly to plant health, crop homogeneity, and pest control. For precision agriculture (PA), the elevation within a field should be precisely controlled. We analyzed variation in elevation within a rice paddy field over one crop cycle. The study took place in a rectangular plot (100 m x 30 m). Elevations within the a plots was measured by a laser-equipped surveying instrument, that could determine elevations to precisions of I mm. The test field was divided into grids with 30 squares; elevation was measured at the center of each 5 x 10-m grid square. This study measured elevation during nine observation periods from pre-plowing to post-harvest. Descriptive statistics showed the highest elevations after plowing due to soil disturbance. One-way analysis of variance (ANOVA) revealed significant elevation differences before and after plowing and transplanting, although elevations were similar over the period of crop growth. Comparison of pre-plowing and post-harvest data showed differences in elevations, indicating that elevation changes occurred during plowing, rice transplanting, plant growth, and harvesting. In summary, the above statistical analysis indicated that elevation changes occurred due to plowing but not during the plant growth season or due to harvesting.

Field Measurements of the New CCTV Tower in Beijing

  • Xu, Y.L.;Zhan, S.;Xia, H.;Xia, Y.;Zhang, N.
    • International Journal of High-Rise Buildings
    • /
    • v.2 no.3
    • /
    • pp.171-178
    • /
    • 2013
  • The emergence of a growing number of tall buildings, often with unusual shapes and innovative structural systems, has led to the realization of the need for and the importance of field measurements. The new China Central Television (CCTV) Tower in Beijing is one of tall buildings with a highly unusual shape and a complex structural system, requiring field measurements to identify its dynamic characteristics for the subsequent dynamic analysis of the tower under wind excitation, seismic-induced ground motion and traffic-induced ground motion. The structural system and the finite element model of the CCTV Tower are first introduced in this paper. The computed natural frequencies and mode shapes are then presented as a reference for the field measurement. After introducing the arrangement of the ambient vibration measurement, the field measured natural frequencies and damping ratios of the CCTV Tower are presented and the measured natural frequencies are finally compared with the computed ones. It was found that the structural damping ratios of the CCTV Tower are small and the computed natural frequencies are smaller than the measured ones by about 12~17%.

Calibrating Electrode Misplacement in Underwater Electric Field Sensor Arrays for the Electric Field-Based Localization of Underwater Vessels (수중 이동체의 전기장 신호 기반 위치추정을 위한 수중 전기장 배열센서의 전극 부설 위치 오차 보정 방법)

  • Kim, Jason;Lee Ingyu;Bae, Ki-Woong;Yu, Son-Cheol
    • Journal of Sensor Science and Technology
    • /
    • v.31 no.5
    • /
    • pp.330-336
    • /
    • 2022
  • This paper proposes a method to calibrate the electrode misplacement in underwater electric field sensor arrays (EFSAs) for accurate measurements of underwater electric field signatures. The electrode misplacement of an EFSA was estimated by measuring the electric field signatures generated by a known electric source and by comparing the measurements with the theoretical calculations under similar measurement conditions. When the EFSA measured the electric field signatures induced by an unknown electric source, the electric properties of the unknown electric source were approximated by considering the optimized estimation of the electrode misplacement of the EFSA. Finally, the measured electric field signatures were calibrated by calculating the theoretical electric field signatures to be measured with an ideally installed EFSA without electrode misplacement; the approximated electric properties of the unknown electric source were also taken into account. Simulations were conducted to test the proposed calibration method. The results showed that the electrode misplacement could be estimated. Further, the electric field measurements and the electric field-based localization of underwater vessels became more accurate after the application of the proposed calibration method. The proposed method will contribute to applications such as the detection and localization of underwater electric sources, which require accurate measurements of underwater electric field signatures.

The Influence of Parallel Magnetic Field on Magnetization Loss in a Bi-2223 Tape (수평자계가 Bi-2223테이프의 자화손실에 미치는 영향)

  • 한형주;류경우;최병주
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2001.02a
    • /
    • pp.185-188
    • /
    • 2001
  • Magnetization loss of a Bi-2223 tape in magnetic fields parallel to the tape surface was measured by a magnetization method. The results indicate that the magnetization loss is hysteretic because the measured loss agrees well with calculated one from a critical state model. In the full field penetration case the magnetization loss increases with the frequency but in the partial field penetration case the influence of the frequency is opposite.

  • PDF

Field-Dependent Characteristics of ER Shock Damper (ER 유체를 이용한 충격절연 댐퍼의 특성 연구)

  • 송현정;최승복;김재환;김경수
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.109-114
    • /
    • 2001
  • This paper presents field-dependent dynamic characteristics of a shock damper featuring an electro-rheological(ER) damper. A cylindrical type of the shock damper is designed and manufactured on the basis of the field-dependent Bingham model. The damping force is then measured with respect to the piston velocity at various electric fields. The measured damping force is incorporated with the 1DOF shock system to analyze the shock isolation performance.

  • PDF

Measurement and Analysis for Electric Fields due to Lightning stepped leaders (뇌방전의 리더진전에 따른 전장파형의 측정과 분석)

  • Lee, B.H.;Jeang, K.H.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2164-2166
    • /
    • 1999
  • This paper is describes the measured electric field waveform radiated by lightning discharge. We have performed measurement and analysis of the electric fields associated with stepped leaders. Electric field measurement system was composed of hemisphere electric field sensor, measurement system of a distance from lightning strokes, automatical recording system, A/D board, personal computer etc. A/D board have high sampling time, high speed data processing, 8bit of resolution. Also, measured characteristics of stepped leaders radiated by were analyzed.

  • PDF

Field Measurements of Joint Movements at JPCP (줄눈콘크리트 포장의 줄눈 거동 측정)

  • Yun, Kyong-Ku;Kim, Dong-Ho;Hong, Chang-Woo;Lee, Joo-Hyung
    • Journal of Industrial Technology
    • /
    • v.21 no.B
    • /
    • pp.325-330
    • /
    • 2001
  • In this research, the early-age movements of joint at JPCP(Jointed Plain Concrete Pavement) were measured by field tests. The field tests were carried out for 5 days just after concrete placement, for 1 day after 52 and 72 days on Chung-Ang Expressway construction site in Dan-yang on the 28th and 29th of May 2001. The joint movements were measured by demec gauge and clip gauge. The results of regression analysis for the data measured during early 5 days showed that the joints of No.4, No.5, No.6, No.10, No.13, and No.15 could be considered as a moving joint. From data analysis on july 20, the joints of No.2, No.9, and No.10 showed the significant correlations from the minus value of coefficient of regression. As a result of regression data on August 8, joint movements occurred at all joints. Joint freezing and closure could be judged from the regression analysis using joint opening and total temperature measured at field tests.

  • PDF

Force acting on a high Tc superconductor at 77K

  • Kim, Yong-Kweon;Katsural, Makoto;Fujita, Hiroyuki
    • Proceedings of the KIEE Conference
    • /
    • 1989.11a
    • /
    • pp.87-90
    • /
    • 1989
  • The force acting on high Tc superconductors at 77K is measured and analyzed numerically. Both values are compared, and the difference between them is discussed. The forces, acting on a superconducting disk (thickness:1[mm], diameter:12[mm]) in an axially-symmetric magnetic field produced by a solenoid or a permanent magnet ring, are measured at 77K. The disk is an YBCO high Tc superconductor. The discrete surface current method(DSCM) is formalized for an axially-symmetric magnetic field. The forces of the superconducting disk in the magnetic field are analyzed using the DSCM, assuming that the disk is a perfect diamagnetic body. When the bottom side of the disk is separated 8[mm] from the top side of the solenoid, and the magnetic field applied on the center of the bottom side of the disk is 96[G], the measured value and the calculated value of the force are 96 and 496[mgf], respectively. The difference between them is caused by a non-perfect diamagnetism of the high Tc superconductor at 77K. It is proposed that a real force acting on high Tc superconductors at 77K can be estimated on the basis of a measured magnetic susceptibility of the high Tc superconductor at 77K and a calculated force of a perfect diamagnetic body.

  • PDF

A Study on the Outlet Drain Discharge from Paddy Field (논의 배수물꼬의 유량에 관한 기초연구)

  • 최진규;김현영;손재권
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.39 no.2
    • /
    • pp.134-142
    • /
    • 1997
  • This study was performed to evaluate the drain runoff characteristics from one paddy field, and to provide the basic data required for the determination of flood discharge and unit drainage water for drainage improvement and farmland consolidation. For this purpose, under the assumption that drain discharge from paddy field was similar to outflow of reservoir, runoff model based on storage equation was applied to the experimental field, and simulated results were compared to the measured discharge at weir point. To estimate effective storage volume of paddy field with water depth, 4 regression formula were examined such as linear, exponential, power, and combined. From the observed runoff characteristics, it was shown to be 3.3~16.3${\ell}$/sec in weir discharge, 57.2~98% in runoff ratio, and relative error of simulated result was 3.0~39.4%, 8.5 ~56.0 % for peak flow and runoff ratio, respectively. Curve number by SCS method was calculated as mean value of 96.4 using measured rainfall and runoff data, it was considered relatively high because paddy field has generally flooding depth contrary to the upland watershed area.

  • PDF

Design of Magnetic Field Compensation System Model for AC Magnetic Field Shielding (교류자기장 차폐를 위한 자기장 상쇄장치 모델의 설계)

  • Choi, Hak-Yun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.7
    • /
    • pp.78-82
    • /
    • 2011
  • In this paper, magnetic field compensation system with an open architecture and can be installed indoors is designed and measured by fabricated. To verify the shielding effectiveness, two rectangular helmholtz coils with 3-axis are fabricated to generate magnetic field and measured magnetic field inside compensation coil for 1~60[Hz], According to measurements, AC shielding effectiveness of compensation system is 96[%] of 1[Hz], 95[%] of 30[Hz] and 90[%] of 60[Hz]. The performance of system therefore can be used as the magnetically shielded room for medical and industrial field.