• Title/Summary/Keyword: Field Difference

Search Result 4,714, Processing Time 0.039 seconds

Comparison between Two 450 mm Multi-Electrode Models

  • Park, Gi-Jeong;Lee, Yun-Seong;Yu, Dae-Ho;Lee, Jin-Won;Jang, Hong-Yeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.490-490
    • /
    • 2013
  • In semiconductor industry, it is expected that plasma process which use 450 mm source will be used at next generation. However, main obstacle of the large area plasma source is plasma uniformity from it. When electrode is enlarged, field difference between center area and side area reduces the plasma uniformity [1-3]. Therefore we investigate multi-electrode which diminish this field difference.We designed two multi-electrode models. One has two segments and the other has five segments. Each multi-electrode model is connected with two power generator and two matchers. One generator and one matcher is connected with center electrode part. The other one generator and the other one matcher is connected with side electrode part. The ion density is measured at 29 points by using floating harmonic method [4-6]. After measuring the data of each multi-electrode model, we discuss the difference of profile between two models' data.

  • PDF

Analysis of microstrip patch array antenna characteristics using finite difference time domain algorithm (유한차분시간영역 알고리듬을 이용한 마이크로스트립 패치 배열 안테나 특성해석)

  • 홍용인
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.2 no.2
    • /
    • pp.197-205
    • /
    • 1998
  • The purpose of this paper is to analyze the electromagnetic field characteristics of array antenna with the finite difference-time domain algorithm. Finite difference equations of Maxwell's equations are defined in cylindrical coordinate systems. To simulate the unbounded problem like a free space, the Mur's absorbing boundary condition is also used. After modeling the array antenna with the grid structure, the transient response of the field distribution is depicted in the time domain.

  • PDF

An experimental study on the field sound insulation performance of the light weight concrete panel using bottom ash (저회를 이용한 경량패널의 현장 차음성능에 관한 실험 연구)

  • Chung, J.Y.;Jeong, G.C.;Lee, B.K.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.65-69
    • /
    • 2007
  • Recently, the method of the apartment building design is changing from wall type to moment structure. Because of this reason, dry wall systems are used plentifully. This study examines the sound insulation performance of the light weight concrete panel using bottom ash. There is the difference of airborne sound isolation between laboratory and field test. For the purpose of searching deviation, we use the prediction tool(Insul 6.0). First, we calculated the prediction data and measured the sound isolation in the wall at the lab. Then, we measured it in the field and compared them. At the base of these datum, we measured the difference.

  • PDF

Study on the Effective Calculation Method of Irrigation Water in a Paddy Fields Area (합리적 관개용수량 산정에 관한 연구)

  • Lee, Yong-Jig;Kim, Sun-Joo;Kim, Phil-Shik;Joo, Uk-Jong;Yang, Yong-Seok
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.48 no.3
    • /
    • pp.11-20
    • /
    • 2006
  • In this study, the actual water management were investigated and analyzed on site for effective use of the paddy irrigation water. And this study is tried to analyze the difference between simulated irrigation water according to current design method and actual water supply in experimental reservoirs. The reservoirs in Idong, Yongdeok and Misan, which are managed by Korea Rural Community & Agriculture Corporation, were selected fur field investigation. The purpose of this study is to suggest an improved method for irrigation water calculation through quantitative and periodical analysis considering the difference between design and actual field condition.

Analysis and Visualization of Temperature Field for Wafer Batch in Furnace (반응로 내 웨이퍼 배치의 온도장 분석 및 가시화)

  • Kang, Seung-Hwan;Lee, Seung Ho;Kim, Byeong Hoon;Ko, Han Seo
    • Journal of the Korean Society of Visualization
    • /
    • v.13 no.3
    • /
    • pp.24-28
    • /
    • 2015
  • The temperature of the wafer batch in the furnace was calculated and its visualized temperature field was analyzed. The main heat transfer mechanisms from the heater wall to the wafers were radiation and conduction, and the finite difference method was used to analyze the complex heat transfer including those two mechanisms. The visualized temperature field shows that the direction of the heat flux in the wafer batch varies during the heating process, and the heat in the wafer batch diffuses faster by conduction within the wafer than by radiation between the wafers, in the condition of the constant temperature at the heater wall and cap.

Observation of Electrical Properties in Field-aged Photovoltaic Module (Field aged 태양전지모듈의 노화현상에 따른 전기적 특성 관찰)

  • Kang, Gi-Hwan;Yu, Gwon-Jong;Ahn, Hyung-Keun;Han, Deuk-Young
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07a
    • /
    • pp.28-32
    • /
    • 2004
  • In this paper, degradation in field-aged PV modules including degradation of interconnect, discoloration of encapsulant and hot spot have been observed and analyzed. From the results, photovoltaic module installed for 6 years shows around 16% drop of electrical properties due to the interconnect degradation and PV module passed 18 years has been found to drop of around 20% mainly by the encapsulant discoloration. Furthermore the difference between low and high temperature of PV array at hot spot goes up to $30^{\circ}C$ and it leads to interconnect degradation. On the other hands, the temperature difference was observed to be around $15^{\circ}C$ at the encapsulant discoloration spot of PV array.

  • PDF

Evaluation of the Small Field of for the Detector Type Medical Linear Accelerator (의료용 선형가속기의 소조사면에 대한 검출기 종류에 따른 평가)

  • Lee, Dong-Woon;Jung, Kang-Kyo;Shin, Gwi-Soon;Cho, Pyong-Kon
    • Journal of radiological science and technology
    • /
    • v.39 no.2
    • /
    • pp.177-184
    • /
    • 2016
  • Recently linear accelerator of radiation therapy intensity modulated radiation therapy, stereotactic radiation therapy are widely used. Such radiation treatment techniques are generally difficult to exclude the small field by using the inverse treatment plan. It is necessary to dose an accurate measurement of characteristics of the small field. Thus, using different detectors to measure the volume of the effective percentage depth dose, beam profile, and the output factor of the small field was to evaluate the dose characteristics of each detector. Experimental results for the X-ray beam 6 MV energy beam quality($PDD_{20}/PDD_{10}$) is $10{\times}10cm^2$ Diode detector is as high as 2.4% compared to Pinpoint detector. All field size to lesser effective volume of Diode detector shows that it is far better than other detectors by more than 50% of small penumbra, therefore spatial resolution far excellent. In field size $2{\times}2cm^2$ Semiflex detector was measured about 2% less than the other detector. Field size $1{\times}1cm^2$ is that there is no judgment about the validity show the difference between 20%. Field size $1{\times}1cm^2$ from the measured values of the Diode detector and Pinpoint detector showed a 13% difference. Less than field size $3{\times}3cm^2$ the feed to the difference between the output factor of the effective volume of the detector to be used for the effective volume available to the detector.

Application of the Equivalent-Field Method for Output Calculation: Is it safe for elongated x-ray fields\ulcorner (출력인자 계산에 이용되는 등가면법의 타당성 연구 : 장방형 X-선 조사면에 대해서 안전한가\ulcorner)

  • Kim, Chang-Seon;Kim, Chul-Yong;Park, Myung-Sun
    • Progress in Medical Physics
    • /
    • v.9 no.4
    • /
    • pp.195-200
    • /
    • 1998
  • Purpose: When an elongated x-ray field is used for treating a patient, the equivalent- field method is commonly used for the output calculation. This study is intended for investigating potential factors such as, beam quality, field elongation ratio, and depth of measurement, which might effect on the applicability of the equivalent square technique for output calculation. The derivation of a 'rule of thumb' for the application criteria of the equivalent-field method is also aimed. Materials and Methods: Three x-ray beams, 4-, 6- and 10-MV, were employed for this study. Width of the rectangular field was ranged from 5-40 cm and the elongation ratio (length/width) 1:0 to 10:0. An elongation effect was measured in a water phantom at three different depths, dmax, 5-cm, and 10-cm. For an elongated field and its equivalent square field, the output factor was measured and the difference in the output factor were examined between two fields. Results and Discussions: As the elongation ratio increases, a larger discrepancy in outputs is observed between the elongated rectangular field and its corresponding equivalent square field. Output was measured larger for an elongated field than for its corresponding equivalent square field and the maximal difference over 10 % was found. The difference was found larger for the smaller field with the same elongation ratio. The effect of the beam quality and the depth of measurement on the output difference was minimal. Conclusion: Based on the study, there is criteria for the application of the method for output calculation. For the combination of long axis and elongation ratio whose relationship satisfies Elongation ratio < (0.48) (Long axis) - 0.5, the equivalent-field method is valid for output calculation within 2 % for the field whose long axis < 25-cm. For other combinations, instead of using the equivalent-field method, direct output measurement is recommended. This criteria can be applied for 4-10 MV x-ray beams up to 10-cm depth.

  • PDF

Hydraulic Characteristics of Surface Irrigation in Paddy Field of Direct Seeding Culture -With paddy field of ridge direct dry seeding- (직파재배 논의 지표관개 수리특성 -건답휴립직파 논을 중심으로-)

  • 정하우;최진용;김대식;박기욱;배승종
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.39 no.4
    • /
    • pp.64-74
    • /
    • 1997
  • The purpose of this study is to analyze hydraulic characteristics of surface irrigation in a paddy field of direct seeding culture. Field experiment was performed in the paddy field of ridge direct dry seeding. Simulation by a numerical model was also accomplished with the data obtained from the field experiment. The model was developed by one dimensional zero-inertia equation and finite difference method. From the result of the field observation, the furrows of the experimental field were found to have various geometric characteristics. Advance distance and time were measured both in the field and by the model simulation for various furrow lengths and irrigation discharges. Roughness coefficients of each furrow were also estimated by the model.

  • PDF

Design of Electrode Shape with B-Spline Curve Under Specified Field Condition (B-Spline곡선을 이용한 지정된 전계조건하의 전극형상 설계)

  • 김응식;박종근
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.39 no.9
    • /
    • pp.964-975
    • /
    • 1990
  • This paper aims at the design of high voltage electrode contour under specified field condition. Defining the contour with B-Spline curve, the number of contour variables can be reduced and very smooth electrode can be obtained. For the analysis of the electric field, Surface Charge Method which has advantages in practical model has been used. As an initial contour, the rod-plane gap has been used since the difference between maximum and minimum field value is relatively large. Various field conditions including uniform field condition are given to the end of the rod electrode. Under uniform field condition, authors designed an electrode whose field-deviation was under 0.5%. Finally, the relation between the curvature and field of the electrode has been checked, which showed that B-Spline curve is appropriate for the shape function.

  • PDF