A Field Study on the Constructability and Performance Evaluation of Waveform Micropile (현장시험을 통한 파형 마이크로파일의 시공성 및 거동 평가)

  • Jang, Young-Eun;Han, Jin-Tae
    • Journal of the Korean Geotechnical Society
    • /
    • v.32 no.10
    • /
    • pp.67-79
    • /
    • 2016
  • Waveform micropile is an advanced construction method that combined the concept of conventional micropile with jet grouting method. This new form of micropile was developed to improve frictional resistance, which consequently leads to achieving higher bearing capacity and cost efficiency. Two field tests were conducted to examine the field applicability as well as to verify the effects of bearing capacity enhancement. In particular, waveform micropile construction using jet grouting method was performed to evaluate the viability of waveform micropile installation. After testing, the surrounding ground was excavated to check the accomplishment on the shape of waveform micropile. The result showed that waveform micropile can be installed by adjusting the grouting time and pressure. In the loading tests, waveform micropile's bearing capacity increased by 1.4 to 2.3 times depending on their shapes when compared with conventional micropile. Overall results clearly demonstrated that waveform micropile is an enhanced construction method that can improve bearing capacity.

The Comparison of Electrical Conductivity for Soil Solutions Extracted in Field Capacity and Saturation-Paste (포장용수량과 포화 반죽 토양용액의 전기전도도 비교)

  • Lee, Ye-Jin;Lee, Jong-Sik;Yang, Jae-E.
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.43 no.6
    • /
    • pp.776-781
    • /
    • 2010
  • Estimating the electrical conductivity of the saturation-paste (SP) is a common method to assess soil salinity. To assess soil salinity realistically, it is important to extract soil solution under field capacity. However, few studies on salinity assessment have been conducted for soil solution extracted under field capacity (-33 kPa; FC) moisture condition due to difficulty in soil solution extraction. This study was conducted to evaluate whether saturation-paste can represent field condition. Soil solutions were extracted from 22 soils in the plastic film house (PFH) and 18 soils in the reclaimed land (RL) at saturation and field capacity moisture conditions. Those were analyzed for pH, EC, cations ($K^+$, $Ca^{2+}$, $Mg^{2+}$, $Na^+$) and anions ($Cl^-$, ${NO_3}^-$, ${PO_4}^{3-}$, ${SO_4}^{2-}$). Both cations and anions of soil solution extracted from FC showed high correlations with ions extracted from SP in the PFH and the RL, except for ${NO_3}^-$, ${PO_4}^{3-}$ in the RL. Results of the t-test, the ECe and $EC_{FC}$ were not significant at significance level 0.05. The slopes of the equations between $EC_{FC}$ and ECe at more than sand 50% soils were higher than less than sand 50% soils, and differences of saturation percentage between SP and FC showed larger as increasing sand percentage. EC was related to soil water retention by soil texture. To determine the EC, soil texture and other soil properties which effect the soil moisture should be considered.

Estimation of Bearing Capacity of SIP Pile Installed by Improved Criteria (개선된 기준으로 시공된 SIP 말뚝의 지지력 평가에 관한 연구)

  • Park, Jong-Bae;Kim, Jung-Soo;Lim, Hae-Sik
    • Journal of the Korean GEO-environmental Society
    • /
    • v.5 no.3
    • /
    • pp.5-15
    • /
    • 2004
  • SIP has been widely used as a low noise and vibration piling method in Korea. But the quality control of SIP was not properly settled down and field workers did not fully understand the principle of SIP method. So not a less troubles were raised at construction site and bearing capacity was not fully mobilized. To settle these problems, Korea National Housing Corporation amended the construction and load test criteria of SIP in 2002. After load tests on the SIPs installed in field according to the new criteria, we found that the bearing capacity in field vs the design load ratio increased and bearing characteristics was enhanced than that installed by the former criteria. To consider the enhanced bearing characteristics in the pile design and determine the adequate design criteria, this paper analyzed the accuracy of design criterion which were commonly used in Korea comparing with the load test results. Analysis result shows that Meyerhof criteria(1976) properly simulates the bearing capacity of SIP installed by the new construction and load test criteria.

  • PDF

Effects of Longitudinal Field in a Multiply-Twisted Superconducting Cable (초전도다중케이블에서의 축방향자계)

  • Cha, Guee-Soo;Sim, Jung-Wook;Park, Jong-Hyeon;Na, Wan-Soo;Lee, Ji-Kwang;Kim, Dong-Hun;Hahn, Song-Yop
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.101-103
    • /
    • 1996
  • Multiply-twist cable is used for a large capacity superconducting cable because it is helpful to reduce AC losses and to increase transport current. In a multiply-twisted cable, the axis of a strand does not coincide with that of cable. Therefore, the longitudinal field is generated by the transport current. The longitudinal field changes the current distribution in the strand and generates additional AC loss. This paper calculates the longitudinal field that is applied to a strand in the multiply-twisted cable. Current distribution of a strand in the cable is also presented. 2nd level superconducting cable is chosen as an analysis model, whose current capacity is 2000A. Calculation result shows the longitudinal field cannot be neglected in low field machines such as superconducting transformer.

  • PDF

Development of Adjustment Factors under Day and Night Conditions for Freeway Capacity to Improve Traffic Safety (교통안전 향상을 위한 주야 변화에 따른 고속도로 용량 보정계수 개발에 관한 연구)

  • Kim, Young Sun;Lee, Sang Soo
    • International Journal of Highway Engineering
    • /
    • v.17 no.4
    • /
    • pp.107-115
    • /
    • 2015
  • PURPOSES: This study analyzes the characteristics of traffic flow on freeway sections under daytime and nighttime conditions to improve traffic safety, and suggests a method to estimate an accurate freeway capacity value that reflects these characteristics. METHODS : The trends and differences in capacity were investigated using comprehensive field data collected under both daytime and nighttime conditions on freeway sections with designated speeds of 80, 100, and 120 kph. RESULTS : The capacity values under nighttime driving conditions were reduced by 3.3%, 6.9%, and 8.8% at 80, 100, and 120 kph, respectively. Several nighttime adjustment factors were deduced for each designated speed category from the analysis results. CONCLUSIONS : It is expected that more accurate capacity values can be estimated for freeway sections under nighttime conditions by applying the resulting adjustment factors. In addition, traffic safety will be improved through the increased efficiency of traffic management on these freeway sections.

A Study on the Characteristics of Bearing Capacity for SIP Piles constructed on Rock Mass (암반에 근입된 SIP 말뚝의 지지력 특성에 관한 연구)

  • Kim, Tae-Hwoon;Park, Jun-Hong;Lee, Song
    • Proceedings of the KSR Conference
    • /
    • 2002.05a
    • /
    • pp.295-300
    • /
    • 2002
  • In this research problems of recent design methods and their improvement for SIP in domestic areas were studied by using the characteristics of load-settlement curves and bearing capacity from field loading tests. Elastic and plastic settlement for total settlement in each loading step conducted domestic areas had a tendency. From these tendency and bearing capacity determined by loading tests we can ascertain that empirical chart can be assistant tool in SIP design. It showes that SIP design using N-value in domestic area with soil condition of grarute type results in very conservative bearing capacity, to be opposed in soil with unprofitable geological condition the design can be insecure. Also, we can ascertain that Meyerhof's bearing capacity used modified N-value on tip part of pile is more applicable than recent design method where tip bearing capacity is 20NAp N-value limited to 50. These results show that modified design method can he more economic than before because of using pile's bearing capacity to tolerable load of pile material.

  • PDF

Study on the Elicitation of Parameter in Designing each Capacity of PV System for Power Industry (전력산업용 PV System의 각 용량별 설계 파라미터 도출에 관한 연구)

  • Kim, ByeongMan;Lee, KilSong;Yang, YeonWon;Shin, HyunWoo;Kim, EuiHwan
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.78.1-78.1
    • /
    • 2010
  • Recently, as much supplied with new-renewable energy, as much invested in PV system. PV system consists of PV module, PCS and Monitering system, and also could be classified into the type and the capacity by installation method and cost etc. When various systems are installed in the field, it is needed to research for applying in the field and establish infrastructure in order to ensure stable efficiency and reliability. In this study, as the basic design of the demonstration test facility, it is designed the basic PV systems for each capacity to test each PCS. In addition, It is drew the climatic conditions such as insolation, temperature and the design parameters such as installation angle, shades for the local demonstration project and expected the generation of each PV system.

  • PDF

Assessment of Reliability and Load Carrying Capacity of Aged Wharf Structure of Pier Type (노후된 잔교식 부두의 신뢰성 및 내하력 평가)

  • 조효남;김성훈;김종규;이승재;최영민
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1994.10a
    • /
    • pp.71-78
    • /
    • 1994
  • The main objectives of the study may be stated as follows : \circled1 the acquisition of fundamental updated data for the assessment of aged wharf structures of pier type based on systematic static/dynamic load testing \circled2 the study of techniques and methods for field testing \circled3 realistic safety and load carrying capacity assessment based on practical reliability analysis. In this study field testing of real structure is performed and the results are compared with those of the 2D and 3D linear structural analysis. It may be seen that the practical reliability methods can be applied for the safety and capacity assessment of aged wharf structures of pier type.

  • PDF

Analysis of Deperming Performance According to Deperming Protocol Transform of Vessel Model (함정모델의 탈자프로토콜 변화에 따른 탈자성능 분석)

  • Kim, Jong-Wang;Kim, Ji-Ho;Park, Hyun-Soo;Jung, Hyun-Ju;Lee, Hyang-Beom
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.9
    • /
    • pp.1693-1699
    • /
    • 2011
  • In this paper, for magnetic silence technology of naval vessel, is to make lab deperm system and to evaluate the deperm capacity of naval vessel regarding deperm protocol. Initial permanent magnetic field of naval vessel is magnetized before deperm, having the magnetic field of the same size, to evaluate the deperm capacity regarding a variety of deperm protocol for experimental reliability growth. Current dead time effect of deperm protocol is measured at the different initial current, which are 8A, 6A and 4A respectively. Furthermore, the experiment under the same condition except changing duty cycle into 50% is carried out. As a result, it is possible to compare the six different experiment outcomes. The result shows that the experiment with dead time improve the deperm capacity more than 48.51 percent comparing to the case without dead time.

Test results confirm the bridge foundation bearing capacity due to construction costs case (교량기초의 지지력확인 시험 결과에 따른 건설비 절감사례)

  • Lee, Soo-Gon;Woo, Jae-Gyung
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.03a
    • /
    • pp.1065-1072
    • /
    • 2010
  • Case studies published in Korea versus the low ground fault is applied on the bridge based on theory or experience in the design of pile bearing capacity by the value of the expression is designed to conduct field tests Disclosure Load bearing capacity value, the result of applying a reasonable construction cost savings of approximately 10 eokyeowon Has, in the design of site investigation was insufficient to require additional efforts. Apply the appropriate value from the extra support in the design of accurate ground survey and air speed to cut the budget and social technology can ensure the reliability was unknown.

  • PDF