• Title/Summary/Keyword: Fiber failure

Search Result 1,182, Processing Time 0.026 seconds

Performance and modeling of high-performance steel fiber reinforced concrete under impact loads

  • Perumal, Ramadoss
    • Computers and Concrete
    • /
    • v.13 no.2
    • /
    • pp.255-270
    • /
    • 2014
  • Impact performance of high-performance concrete (HPC) and SFRC at 28-day and 56-day under the action of repeated dynamic loading was studied. Silica fume replacement at 10% and 15% by mass and crimped steel fiber ($V_f$ = 0.5%- 1.5%) with aspect ratios of 80 and 53 were used in the concrete mixes. Results indicated that addition of fibers in HPC can effectively restrain the initiation and propagation of cracks under stress, and enhance the impact strengths and toughness of HPC. Variation of fiber aspect ratio has minor effect on improvement in impact strength. Based on the experimental data, failure resistance prediction models were developed with correlation coefficient (R) = 0.96 and the estimated absolute variation is 1.82% and on validation, the integral absolute error (IAE) determined is 10.49%. On analyzing the data collected, linear relationship for the prediction of failure resistance with R= 0.99 was obtained. IAE value of 10.26% for the model indicates better the reliability of model. Multiple linear regression model was developed to predict the ultimate failure resistance with multiple R= 0.96 and absolute variation obtained is 4.9%.

Evaluation of Failure Strength of Woven CFRP Composite Plate Subject to Axial Load by Tan-Cheng Failure Criterion (Tan-Cheng 파손기준을 이용한 직물 CFRP 적층판의 원거리 하중에 대한 파괴강도 평가)

  • Kim, Sang-Young;Park, Hong-Sun;Kang, Min-Sung;Lee, Woo-Hyung;Choi, Jung-Hun;Koo, Jae-Mean;Seok, Chang-Sung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.33 no.4
    • /
    • pp.360-365
    • /
    • 2009
  • In the manufacture of CFRP(Carbon Fiber Reinforced Polymer Composite) composite structures, various independent components join by bolts and pins. Holes for bolts and pins have an effect on the failure strength of such structures, because those act as notches in structures. The failure characteristic of such structures are different from those of plain plate subject to remote load. In this paper, tensile properties of woven CFRP composite plates with laminates of $0^{\circ}$, $30^{\circ}$ and $45^{\circ}$ were obtained according to ASTM D 3039. By using obtained tensile failure strength and Tan-Cheng failure criterion, tensile failure strength of CFRP laminate with arbitrary fiber angle were evaluated. Also, the degradation of tensile properties by center hole(${\phi}10mm$) with a remote load was evaluated and the failure strengths were applied to Tan's failure criterion, similarly.

Failure detection of composite structures using a fiber Bragg grating sensor (광섬유 브래그 격자 센서를 이용한 복합재 구조물의 파손 검출)

  • 고종인;김천곤;홍창선
    • Composites Research
    • /
    • v.17 no.2
    • /
    • pp.28-33
    • /
    • 2004
  • Failure detection in a cross-ply laminated composite beam under tensile loading were performed using a fiber Bragg grating (FBG) sensor. A Passive Mach-Zehnder interferometric demodulator was proposed to enhance sensitivity and bandwidth. The proposed FBG sensor system without active device such as a phase modulator is very simple in configuration, easy to implement and enables the measurement of high-frequency vibration with low strain amplitude such as impact or failure signal. Failure signals detected by a FBG sensor had offset value corresponding to the strain shift with vibration at a maximum frequency of several hundreds of kilohertz. at the instant of transverse crack propagation in the 90 degree layer of composite beam.

Research on eccentric compression of ultra-high performance fiber reinforced concrete columns

  • Ma, Kaize;Ma, Yudong;Liu, Boquan
    • Structural Engineering and Mechanics
    • /
    • v.71 no.3
    • /
    • pp.211-221
    • /
    • 2019
  • To study the eccentric compression behavior of ultra-high performance fiber reinforced concrete (UHPFRC) columns, six UHPFRC columns and one high-strength concrete (HSC) column were tested. Variation parameters include load eccentricity, volume of steel fibers and stirrup ratio. The crack pattern, failure mode, bearing capacity, and deformation of the specimens were studied. The results showed that the UHPFRC columns had different failure modes. The large eccentric compression failure mode was the longitudinal tensile reinforcements yielded and many horizontal cracks appeared in the tension zone. The small eccentric compression failure mode was the longitudinal compressive reinforcements yielded and vertical cracks appeared in the compressive zone. Because of the bridging effect of steel fibers, the number of cracks significantly increased, and the width of cracks decreased. The load-deflection curves of the UHPFRC columns showed gradually descending without sudden dropping, indicating that the specimens had better deformation. The finite element (FE) analysis was performed to stimulate the damage process of the specimens with monotonic loading. The concrete damaged plasticity (CDP) model was adopted to characterize the behaviour of UHPFRC. The contribution of the UHPFRC tensile strength was considered in the bearing capacity, and the theoretical calculation formulas were derived. The theoretical calculation results were consistent with the test results. This research can provide the experimental and theoretical basis for UHPFRC columns in engineering applications.

Cyclic performance of steel fiber-reinforced concrete exterior beam-column joints

  • Oinam, Romanbabu M.;Kumar, P.C. Ashwin;Sahoo, Dipti R.
    • Earthquakes and Structures
    • /
    • v.16 no.5
    • /
    • pp.533-546
    • /
    • 2019
  • This study presents an experimental investigation on six beam-column joint specimens under the lateral cyclic loading. The aim was to explore the effectiveness of steel fiber-reinforced concrete (SFRC) in reducing the transverse shear stirrups in beam-column joints of the reinforced concrete (RC) frames with strong-columns and weak-beams. Two RC and four SFRC specimens with different types of reinforcement detailing and steel fibers of volume fraction in the range of 0.75-1.5% were tested under gradually increasing cyclic displacements. The main parameters investigated were lateral load-resisting capacity, hysteresis response, energy dissipation capacity, stiffness degradation, viscous damping variation, and mode of failure. Test results showed that the diagonally bent configuration of beam longitudinal bars in the beam-column joints resulted in the shear failure at the joint region against the flexural failure of beams having straight bar configurations. However, all SFRC specimens exhibited similar lateral strength, energy dissipation potential and mode of failure even in the absence of transverse steel in the beam-column joints. Finally, a methodology has been proposed to compute the shear strength of SFRC beam-column joints under the lateral loading condition.

Structural Behavior of Pre-loaded RC Beams Strengthened by SP, CFS, and CFL (재하상태에서 보강된 철근 콘크리트보의 보강 재료에 따른 구조적 거동)

  • Chung, Lan;Lee, Young-Jea;Moon, Heui-Jeung;Lee, Kyung-Un;Jung, Sang-Jin
    • Magazine of the Korea Concrete Institute
    • /
    • v.11 no.1
    • /
    • pp.201-208
    • /
    • 1999
  • In recent years, strengthening by steel plate, carbon fiber sheets, and carbon fiber laminate is spotlighted in order to repair and rehabilitation of R/C structures. In this study, 3 methods of rehabilitation technique were analyzed from the test results. Test parameters were the width of cracks, the method of repair and rehabilitation, the magnitude of pre-load. Deflections, failure loads, strains of reinforcing bar, strains of carbon fiber sheet, carbon fiber laminate and steel plate were measured during the tests. The primary purpose of this research was to analyze the failure mode and structural behavior of strengthened RC beams with/without superimposed pre-load. Test results should that no significant difference was observed between with pre-loaded specimens and no-loaded specimens during rehabilitation.

The Strength Characteristics of PVA Fiber Reinforced CSG Materials (PVA섬유 보강 CSG 재료의 강도특성)

  • Jin, Guang-Ri;Kim, Ki-Young;Quan, He-Chun;Kim, Kyu-Won
    • Journal of the Korean Geotechnical Society
    • /
    • v.29 no.12
    • /
    • pp.95-104
    • /
    • 2013
  • Recently, application of CSG is increasing in various design construction projects. At the initial stage of cementation CSG materials show the same mechanical characteristics as soil, however, as the cementation process develops, CSG materials gradually reveal material characteristics of concrete. The hardened CSG manifests elastic behavior such as maximum strength at small strain range and rapid brittle failure. In this research, PVA fiber stiffeners were used in order to: (1) reduce such brittle behavioral characteristics; (2) improve the relatively weak tension performance of CSG materials. The binding strength between the bed materials and fiber prevents rapid brittle failure and increases tensional strength of fiber reinforced CSG materials.Test results show that fiber reinforcement alone could induce the stress-strain characteristics of CSG materials from brittle failure to ductile failure and also increase the residual strength.

Retentive strength of different intracanal posts in restorations of anterior primary teeth: an in vitro study

  • Memarpour, Mahtab;Shafiei, Fereshteh;Abbaszadeh, Maryam
    • Restorative Dentistry and Endodontics
    • /
    • v.38 no.4
    • /
    • pp.215-221
    • /
    • 2013
  • Objectives: To determine the retentive strength and failure mode of undercut composite post, glass fiber post and polyethylene fiber post luted with flowable composite resin and resin-cement. Materials and Methods: Coronal parts of 120 primary canine teeth were sectioned and specimens were treated endodontically. The teeth were randomly divided into 6 groups (n = 20). Prepared root canals received intracanal retainers with a short composite post, undercut composite post, glass fiber post luted with flowable resin or resin-cement, and polyethylene fiber post luted with flowable resin or resin-cement. After crown reconstruction, samples were tested for retentive strength and failure mode. Statistical analysis was done with one-way ANOVA and Tukey tests (p < 0.05). Results: There were statistically significant differences between groups (p = 0.001). Mean bond strength in the undercut group was significantly greater than in the short composite post (p = 0.030), and the glass fiber post (p = 0.001) and the polyethylene fiber post group luted with resin-cement (p = 0.008). However, the differences between the undercut group and the groups with flowable composite as the luting agent were not significant (p = 0.068, p = 0.557). Adhesive failure was more frequent in the fiber post groups. Conclusions: Although the composite post with undercutting showed the greatest resistance to dislodgement, fiber posts cemented with flowable composite resin provided acceptable results in terms of retentive strength and fracture mode.

Evaluation of Failure Mode in Concrete Beam Restrengthened with GFRP with Various Initial Conditions (GFRP로 보강된 다양한 초기 조건의 콘크리트보의 파괴 거동 평가)

  • Jin-Won Nam;Seung-Jun Kwon
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.11 no.3
    • /
    • pp.177-183
    • /
    • 2023
  • Various failure modes occur in the concrete beams reinforced with GFRP(Glass Fiber Reinforced Plastic) under initial condition and repairing patterns. In this study, the failure behaviors of concrete beams restrengthened with GFRP sheet with slightly higher elastic modulus than concrete were investigated. For the tests, concrete beams with 24 MPa were manufactured, and the effects of initial notch, overlapping, end-strip reinforcement, and fiber anchors were analyzed on failure load. The cases of GFRP overlap around notch and the initial notch showed increasing failure loads similar to those of normal restrengthened case since the epoxy of the saturated GFRP sufficiently repaired the notch area. Compared to the control case without restrengthening of GFRP, the concrete with initial notch showed 0.78 of loading ratio and normal restrengthening showed 4.43~5.61 times of increasing ratio of failure loading, where interface-debonding from flexural crack were mainly observed. The most ideal failure behavior, break of GFRP, was observed when end-strip over 1/3 height from bottom and fiber anchor were installed, which showed increasing failure load over 150 % to normal restrengthening.

Probabilistic Fiber Strength of Composite Pressure Vessel (복합재 압력용기의 확률 섬유 강도)

  • 황태경;홍창선;김천곤
    • Composites Research
    • /
    • v.16 no.6
    • /
    • pp.1-9
    • /
    • 2003
  • In this paper, probabilistic failure analysis based on Weibull distribution function is proposed to predict the fiber strength of composite pressure vessel. And, experimental tests were performed using fiber strand specimens, unidirectional laminate specimens and composite pressure vessels to confirm the volumetric size effect on the fiber strength. As an analytical method, the Weibull weakest link model and the sequential multi-step failure model are considered and mutually compared. The volumetric size effect shows the clearly observed tendency towards fiber strength degradation with increasing stressed volume. Good agreement of fiber strength distribution was shown between test data and predicted results for unidirectional laminate and hoop ply in pressure vessel. The site effect on fiber strength depends on material and processing factors, the reduction of fiber strength due to the stressed volume shows different values according to the variation of material and processing conditions.